1000 resultados para Quantitative electroencephalography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

利用Nd:YAG激光器输出的532nm激光束对位于空气中的标准变形铝合金样品进行烧蚀产生了激光诱导等离子体.对测量的230—440nm波长范围的光谱进行了谱线标定,同时基于自由定标方法对样品成分进行了定量分析,确定了样品中的元素含量.分析结果与标准值具有较好的一致性.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laser-induced breakdown plasma is produced by using Q-switched Nd: YAG laser operating at 532 nm, which interacts with the Al alloy sample target in air. The spectral lines in the 230-440 nm wavelength range have been identified, and based on the calibration-free method, the mass concentration of Al alloy are obtained, which is in good agreement with the standard value of the sample.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the capabilities of laser-induced break down spectroscopy (LIBS) for rapid analysis to multi-component plant are illustrated using a 1064 nm laser focused onto the surface of folium lycii. Based on homogeneous plasma assumption, nine of essential micronutrients in folium lycii are identified. Using Saha equation and Boltzmann plot method electron density and plasma temperature are obtained, and the irrelative concentration (Ca, Mg, Al, Si, Ti, Na, K, Li, and Sr) are obtained employing a semi-quantitative method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laser-induced breakdown spectroscopy (LIBS) as a powerful analytical technique is applied to analyze trace-elements in fresh plant samples. We investigate the LIBS spectra of fresh holly leaves and observe more than 430 lines emitted from 25 elements and molecules in the region 230-438 nm. The influence of laser wavelength on LIBS applied to semi-quantitative analysis of trace-element contents in plant samples is studied. The results show that the UV laser has lower relative standard deviations and better repeatability for semi-quantitative analysis of trace-element contents in plant samples. This work may be helpful for improving the quantitative analysis power of LIBS applied to plant samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An apparatus including a rotary-type injector was designed for quantitative sample injection in capillary electrophoresis (CE), in which both pressurized flow and electroosmotic flow were used to drive the background electrolyte solution. A relative standard deviation of peak area of lower than 1% was achieved by using this apparatus. The effects of back-pressure regulator, restrictor, and applied voltage on separation efficiency and resolution were investigated. The utility of this apparatus in both micro-HPLC and pressurized capillary electrochromatography (pCEC) was also demonstrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Capillary zone electrophoresis (CZE) was used to study the interaction between pUC19DNA (pUC19) and ovalbumin (Ova). Samples containing pUC19 and Ova at various ratios were incubated at room temperature and were then separated by CZE with tris-acetate buffer at pH 7.2. Reduction in ultraviolet (UV) absorbance of pUC19 was due to the decrease of free pUC19 after binding to Ova. The binding constant of the interaction calculated from the Scatchard plot was (1.46+/-0.15) x 10(5) M-1. The use of polyacrylamide-coated capillary showed better effects than that of uncoated capillary. The results show that it is important to keep a constant ionic strength in the samples in order to obtain accurate quantitative data in binding assays by CZE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, source apportionment techniques are employed to identify and quantify the major particle pollution source classes affecting a monitoring site in metropolitan Boston, MA. A Principal Component Analysis (PCA) of paniculate elemental data allows the estimation of mass contributions for five fine mass panicle source classes (soil, motor vehicle, coal related, oil and salt aerosols), and six coarse panicle source classes (soil, motor vehicle, refuse incineration, residual oil, salt and sulfate aerosols). Also derived are the elemental characteristics of those source aerosols and their contributions to the total recorded elemental concentrations (i.e. an elemental mass balance). These are estimated by applying a new approach to apportioning mass among various PCA source components: the calculation of Absolute Principal Component Scores, and the subsequent regression of daily mass and elemental concentrations on these scores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative electrochemilumineseence (ECL) detection of a model protein, bovine serum albumin (BSA) was achieved via biotin-avidin interaction using an avidin-based sensor and a well-developed ECL system of tris(2,2'-bipyridine) ruthenium(II) derivative as label and tri-n-propylamine (TPA) as coreactant. To detect the protein, avidin was linked to the glassy carbon electrode through passive adsorptions and covalent interaction with carboxylate-terminated carbon nanotubes that was used as binder to immobilize avidin onto the electrode. Then, biotinylated BSA tagged with tris(2,2'-bipyridine) ruthenium(II) label was attached to the prepared avidin surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A practical solution of qualitatively analyzing quaternary alkaloids in coptis-scute herb couple by electrospray ionization mass spectrometry(ESI-MS) was developed. Without the complicated pretreatment of sample, the active ingredients including berberine, palmatine, coptisine, jatrorrhizine, epiberberine, and columbamine were identified and some relative content changing rules of alkaloids in coptis-scute couple were summarized in this article. The overall profiles of the complex extracts were obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mass spectrometry is not able to differentiate NOx and N2 from other interferences (e.g. CO and C2H4) in the deNOx reactions. In the present study, a quantitative method for analysis of NOx and N2 simultaneously in these reactions with an assisted converter operated at higher temperature under O2-rich condition, which eliminates the interferences, is developed. The NOx conversion from this method is comparable to the one from an Automotive Emission Analyser equipped with NOx electrochemical sensor. Two types of deNOx reactions are tested in terms of selectivity of N2 production. The application of this method is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method for quantitative analysis of lactide has been developed by applying chemical kinetics to a HPLC system. The most important advance is its practical approach to the quantification of analytes that are unstable in the HPLC mobile phase. In HPLC analysis, anhydrous mobile phases cannot separate lactide from impurities, and only mixtures of water and organic solvent can achieve effective separation. By selecting conditions for testing and studying the kinetics of lactide hydrolysis, extensive experiments revealed that lactide degradation can be treated as a pseudo-first-order reaction under the given HPLC conditions, and lactide content or purity can be quantitatively determined. This method is practical for measuring the purity of the intermediate lactide in polylactic acid (PLA) production and the lactide content in PLA.