851 resultados para Power Distribution
Resumo:
Pós-graduação em História - FCLAS
Resumo:
This paper presents the development and the main results for an interleaved boost rectifier operating as a special input power stage for a trolleybus type vehicle, allowing its feeding by alternate current (AC) or direct current (DC) distribution power systems. When feeding with two wires (single phase) alternate current distribution system, the converter accomplish active power factor correction, providing a relatively sinusoidal current with low total harmonic distortion (THD) and fully complying with IEC 61000-3-4 standards. In addition, a management control system promotes the required automatic operation changes for the proposed rectifier when the vehicle is changing from the DC distribution power system to the AC distribution power system and vice-versa, keeping its original electrical DC system characteristics for the adjustable speed driver sub-system. The main experimental results for a prototype rated at 150kW are presented, considering its application for a trolleybus with DC adjustable speed driver, demonstrating the proposed converter benefits and the possibility of AC feeding system for trolleybus type vehicle.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
The first approach in this work is the concept of the electric power transmission and distribution system, as well as the survey of the current condition of substations chosen to thus identify the importance of having a suitable design with respect to security due to the need to obtain the approval for the operation of the substation according to the standards valid in the country. Present the guidelines and present needs when designing improvements, thus ensuring the company for more safety and reliability. From the company's point of view is an opportunity to reduce the cost of maintenance, and the professional point of view is an opportunity that allows a comprehensive study of legal requirements for the operation of substations
Resumo:
The public consultation n° 018/2014, for review the Module 8 of Procedures of Electricity Distribution (PRODIST), conducted by National Agency of Electric Energy (ANEEL), aims to improve the regulation of power quality, considering the phenomena harmonic distortion, voltage unbalance, voltage fluctuation and short term voltage variation. These regulatory changes impact in the way of analysis and treatment, of power quality disruption, by the electricity distribution. The developed work makes a study about the applications of these new regulatory requests and hopes to contribute with a better understanding. Through power quality measurements, in distribution substations, with different load profiles (industrial, urban and rural), was obtained a real view of the system, under the aspect of power quality, to evaluate the regulation adherence to the current version and proposed. In this case study, although being in accordance with the current methodology, happened a transgression of propose. With a comparative analysis, was possible to identify some phenomena that were more flexible in the proposed revision and others with more severe monitoring
Resumo:
The objective of this work is to conduct a comparative study between the fuse key and the single-phase seccionalizador, which are protective equipment used in an electricity distribution networks. This study has also the purpose to reduce the number of electrical power breakdown. Distribution networks are not free from faults, disturbances and failures, then the occurrence of adversities on the network, which may be transient or permanent faults, results in the interruption of electric power. Thus, there are protective systems of distribution networks, which aims to ensure that the electric system continues to function. The incidence of transient faults in the distribution network of this electricity company was used to generate immediate shutdown of customers due to the bad use of fuses as protective equipment by the reclosers. With the use of the fuse switch in the distribution network, there was the immediate shutdown of customers, however, using the single-phase seccionalizador as protective equipment by the reclosers, there are three attempts to restart the electricity power. As the attempts to restart the electricity power are able to eliminate a transient fault, not causing shutdown of any costumer, with the implementation of single-phase sectionalizers to replace the fuses, the number of company shutdowns due to transient faults was reduced by 47.6%
Resumo:
The first approach in this work is the concept of the electric power transmission and distribution system, as well as the survey of the current condition of substations chosen to thus identify the importance of having a suitable design with respect to security due to the need to obtain the approval for the operation of the substation according to the standards valid in the country. Present the guidelines and present needs when designing improvements, thus ensuring the company for more safety and reliability. From the company's point of view is an opportunity to reduce the cost of maintenance, and the professional point of view is an opportunity that allows a comprehensive study of legal requirements for the operation of substations
Resumo:
The public consultation n° 018/2014, for review the Module 8 of Procedures of Electricity Distribution (PRODIST), conducted by National Agency of Electric Energy (ANEEL), aims to improve the regulation of power quality, considering the phenomena harmonic distortion, voltage unbalance, voltage fluctuation and short term voltage variation. These regulatory changes impact in the way of analysis and treatment, of power quality disruption, by the electricity distribution. The developed work makes a study about the applications of these new regulatory requests and hopes to contribute with a better understanding. Through power quality measurements, in distribution substations, with different load profiles (industrial, urban and rural), was obtained a real view of the system, under the aspect of power quality, to evaluate the regulation adherence to the current version and proposed. In this case study, although being in accordance with the current methodology, happened a transgression of propose. With a comparative analysis, was possible to identify some phenomena that were more flexible in the proposed revision and others with more severe monitoring
Resumo:
The objective of this work is to conduct a comparative study between the fuse key and the single-phase seccionalizador, which are protective equipment used in an electricity distribution networks. This study has also the purpose to reduce the number of electrical power breakdown. Distribution networks are not free from faults, disturbances and failures, then the occurrence of adversities on the network, which may be transient or permanent faults, results in the interruption of electric power. Thus, there are protective systems of distribution networks, which aims to ensure that the electric system continues to function. The incidence of transient faults in the distribution network of this electricity company was used to generate immediate shutdown of customers due to the bad use of fuses as protective equipment by the reclosers. With the use of the fuse switch in the distribution network, there was the immediate shutdown of customers, however, using the single-phase seccionalizador as protective equipment by the reclosers, there are three attempts to restart the electricity power. As the attempts to restart the electricity power are able to eliminate a transient fault, not causing shutdown of any costumer, with the implementation of single-phase sectionalizers to replace the fuses, the number of company shutdowns due to transient faults was reduced by 47.6%
Resumo:
Máster Universitario en Eficiencia Energética (SIANI)
Resumo:
In this report a new automated optical test for next generation of photonic integrated circuits (PICs) is provided by the test-bed design and assessment. After a briefly analysis of critical problems of actual optical tests, the main test features are defined: automation and flexibility, relaxed alignment procedure, speed up of entire test and data reliability. After studying varied solutions, the test-bed components are defined to be lens array, photo-detector array, and software controller. Each device is studied and calibrated, the spatial resolution, and reliability against interference at the photo-detector array are studied. The software is programmed in order to manage both PIC input, and photo-detector array output as well as data analysis. The test is validated by analysing state-of-art 16 ports PIC: the waveguide location, current versus power, and time-spatial power distribution are measured as well as the optical continuity of an entire path of PIC. Complexity, alignment tolerance, time of measurement are also discussed.
Resumo:
La corretta modellizzazione della zona del riflettore dei sistemi GEN III+ è un passaggio fondamentale per un’accurata predizione dei parametri di cella il cui valore influenza direttamente la distribuzione di potenza su tutto il nocciolo. Tale esigenza si è resa ancora più stringente dopo la constatazione che il fenomeno del “tilt power” risulta essere più amplificato nei noccioli nucleari equipaggiati con un riflettore pesante. Per tali ragioni, nel presente lavoro di tesi si è dedicata particolare attenzione alle metodiche di modellizzazione ed alla generazione delle sezioni d’urto efficaci omogenee ed agli assembly discontinuity factors (ADF) nella zona di riflessione. Il codice deterministico utilizzato per il calcolo è SCALE 6.1.3. La notevole differenza nelle proprietà neutroniche associata ad un’elevata eterogeneità geometrica tra un nocciolo ed un riflettore hanno suggerito di effettuare un’analisi preliminare sul sistema riflettente GEN II proposto nel benchmark NEA-NSC-DOC (2013) per testare la capacità di SCALE 6.1.3 di effettuare un corretto calcolo di cella adottando una modellizzazione monodimensionale assembly/riflettore. I risultati ottenuti sono confrontati con quelli presentati nel benchmark e e con quelli valutati attraverso il codice Monte Carlo SERPENT 2.0 confermando la capacità di calcolo di SCALE 6.1.3. L’analisi sulla modellizzazione dei sistemi riflettenti GEN III+ è stata effettuata ricavando il valore dei parametri di cella per configurazioni omogenee ed una serie di configurazioni geometriche esatte che comprendono tutte le modellizzazioni del sistema riflettente lungo la direzione angolare del riflettore. Si è inoltre effettuata un’analisi di sensitività su parametri operativi e sui parametri di codice. Si è infine effettuato un calcolo in color-set per indagare l’influenza degli effetti 2-D sui parametri di cella. I risultati prodotti rappresentano un contributo migliorativo nella conoscenza dei parametri di cella di riflettore e potranno essere utilizzati per una più precisa valutazione del fenomeno del tilt nei sistemi GEN III+.
Resumo:
The early detection of subjects with probable Alzheimer's disease (AD) is crucial for effective appliance of treatment strategies. Here we explored the ability of a multitude of linear and non-linear classification algorithms to discriminate between the electroencephalograms (EEGs) of patients with varying degree of AD and their age-matched control subjects. Absolute and relative spectral power, distribution of spectral power, and measures of spatial synchronization were calculated from recordings of resting eyes-closed continuous EEGs of 45 healthy controls, 116 patients with mild AD and 81 patients with moderate AD, recruited in two different centers (Stockholm, New York). The applied classification algorithms were: principal component linear discriminant analysis (PC LDA), partial least squares LDA (PLS LDA), principal component logistic regression (PC LR), partial least squares logistic regression (PLS LR), bagging, random forest, support vector machines (SVM) and feed-forward neural network. Based on 10-fold cross-validation runs it could be demonstrated that even tough modern computer-intensive classification algorithms such as random forests, SVM and neural networks show a slight superiority, more classical classification algorithms performed nearly equally well. Using random forests classification a considerable sensitivity of up to 85% and a specificity of 78%, respectively for the test of even only mild AD patients has been reached, whereas for the comparison of moderate AD vs. controls, using SVM and neural networks, values of 89% and 88% for sensitivity and specificity were achieved. Such a remarkable performance proves the value of these classification algorithms for clinical diagnostics.
Resumo:
Studies are suggesting that hurricane hazard patterns (e.g. intensity and frequency) may change as a consequence of the changing global climate. As hurricane patterns change, it can be expected that hurricane damage risks and costs may change as a result. This indicates the necessity to develop hurricane risk assessment models that are capable of accounting for changing hurricane hazard patterns, and develop hurricane mitigation and climatic adaptation strategies. This thesis proposes a comprehensive hurricane risk assessment and mitigation strategies that account for a changing global climate and that has the ability of being adapted to various types of infrastructure including residential buildings and power distribution poles. The framework includes hurricane wind field models, hurricane surge height models and hurricane vulnerability models to estimate damage risks due to hurricane wind speed, hurricane frequency, and hurricane-induced storm surge and accounts for the timedependant properties of these parameters as a result of climate change. The research then implements median insured house values, discount rates, housing inventory, etc. to estimate hurricane damage costs to residential construction. The framework was also adapted to timber distribution poles to assess the impacts climate change may have on timber distribution pole failure. This research finds that climate change may have a significant impact on the hurricane damage risks and damage costs of residential construction and timber distribution poles. In an effort to reduce damage costs, this research develops mitigation/adaptation strategies for residential construction and timber distribution poles. The costeffectiveness of these adaptation/mitigation strategies are evaluated through the use of a Life-Cycle Cost (LCC) analysis. In addition, a scenario-based analysis of mitigation strategies for timber distribution poles is included. For both residential construction and timber distribution poles, adaptation/mitigation measures were found to reduce damage costs. Finally, the research develops the Coastal Community Social Vulnerability Index (CCSVI) to include the social vulnerability of a region to hurricane hazards within this hurricane risk assessment. This index quantifies the social vulnerability of a region, by combining various social characteristics of a region with time-dependant parameters of hurricanes (i.e. hurricane wind and hurricane-induced storm surge). Climate change was found to have an impact on the CCSVI (i.e. climate change may have an impact on the social vulnerability of hurricane-prone regions).