935 resultados para Pollutant Removal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper develops the basis for a self-consistent, operationally useful, reactive pollutant dispersion model, for application in urban environments. The model addresses the multi-scale nature of the physical and chemical processes and the interaction between the different scales. The methodology builds on existing techniques of source apportionment in pollutant dispersion and on reduction techniques of detailed chemical mechanisms. © 2005 Published by Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thin film transistors (TFTs) utilizing an hydrogenated amorphous silicon (a-Si:H) channel layer exhibit a shift in the threshold voltage with time under the application of a gate bias voltage due to the creation of metastable defects. These defects are removed by annealing the device with zero gate bias applied. The defect removal process can be characterized by a thermalization energy which is, in turn, dependent upon an attempt-to-escape frequency for defect removal. The threshold voltage of both hydrogenated and deuterated amorphous silicon (a-Si:D) TFTs has been measured as a function of annealing time and temperature. Using a molecular dynamics simulation of hydrogen and deuterium in a silicon network in the H2 * configuration, it is shown that the experimental results are consistent with an attempt-to-escape frequency of (4.4 ± 0.3) × 1013 Hz and (5.7 ± 0.3) × 1013 Hz for a-Si:H and a-Si:D respectively which is attributed to the oscillation of the Si-H and Si-D bonds. Using this approach, it becomes possible to describe defect removal in hydrogenated and deuterated material by the thermalization energies of (1.552 ± 0.003) eV and (1.559 ± 0.003) eV respectively. This correlates with the energy per atom of the Si-H and Si-D bonds. © 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article explores the possibility of using a laser to remove toner-print from office paper. Removal of print would allow paper to be re-used instead of being recycled or disposed into a landfill. This might reduce climate change gas emissions per tonne of office paper by between 45% and 95%. Although there is little previous research on the area, a number of related articles on paper conservation methods using laser radiation can be found in literature. Different authors have studied the effects of laser energy on blank paper and its application for cleaning soiled paper. However, this study examines toner-print removal from paper by laser ablation. In this article a laser in the visible range is applied to a single toner-paper combination with a range of energy fluences. Results are evaluated by means of colour measurements under the L*a*b* colour space and SEM images. Analysis of the samples reveals that there are parameters under which it is possible to remove toner from paper without causing significant discolouration or damage to the substrate. This means that it is technically possible to remove toner-print for paper re-use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and effective method is described for converting dry fish products infested with fungus and red halophilic bacteria to acceptable ones. Washing, drying and then smearing with a mixture of 3% sodium propionate in dry, refined salt in a ratio of 1 part mixture: 10 parts dry fish resulted in the fish having a shelf life of 5 months.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chitosan from prawn waste was used for the removal of mercury from solutions. Mercuric chloride solutions containing 250, 500, 1000, 10000 and 100000 ng of Hg super(+2)/ml were treated with chitosan samples of different particle size for different periods. The effect of initial concentration of mercury in the solution, particle size of chitosan and time of treatment on the adsorption of Hg super(+2) was studied. The residual mercury content after treatment for ten min. with chitosan of 40 mesh size from a solution of initial concentration 10000 ng/ml was 10 ng/ml whereas it was 50 ng/ml for chitosan of larger particle size (10-20 mesh). From solutions of lower concentrations complete removal of mercury was possible by chitosan treatment. Though the particle size and time of treatment have significant effect, the concentration of mercury in solution is more influential on the removal of mercury from solution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Linear alkylbenzene sulfonate (LAS) are widely used in detergent industry. Due to contaminants entering the water, and the effects of their accumulation in fish, LAS, has a great importance in environmental pollution. In the present study, accumulation of LAS and its histological effects on gill tissue, liver and kidney of Caspian kutum (Rutilus frisii kutum) were studied. Caspian kutum is the most important and most valuable teleosts of the Caspian Sea. Due to releasing Caspian Kutum in rivers and Anzali Lagoon and unlimited entry of wastewater to the aquatic ecosystem, research on the impact of LAS on Caspian kutum is important. In the present study, fish exposed to sublethal concentrations of LAS (0.58, 1.16 and 2.32 mg/l) for 192 hours. Control treatments with three replicates at 0, 24, 48, 72, 96 and 192 hours were done. For assessments of the histological effects of LAS, tissue sections prepared and by using Hematoxylin - Eosin were stained, then the prepared sections, examined by light microscopy. For determination of the bio accumulation of LAS, the soxhlet extraction and solid phase extraction was performed to determine the amount of LAS using HPLC with fluorescence detector. According to results average of bioconcentration factor and LAS concentrations in fish had reached stable levels after approximately 72 h and thus represented steady state BCF values in this species. The value of steady-state bio-concentration factor of total LAS was 33.96 L.Kg- 1 and for each of the homologous C10-n-LAS, C11-n-LAS, C12-n-LAS and C13-n- LAS were 3.84, 6.15, 8.58 and 15.57 L.Kg-1 respectively. According to the results obtained in gills exposed to LAS, histopathological alteration include hypertrophy, lifting of lamella epithelium, edema, clubbing of lamellae hyperplasia, lamellar fusion and aneurysm were seen. In liver tissue exposed to three concentrations of LAS, congestion and dilation of sinusoids, irregular-shaped nuclei and degeneration in the hepatocyte, vacuolar degeneration and necrosis were observed. In kidney exposed to three concentrations of LAS, reduction of the interstitial haematopoietic tissue, degeneration in the epithelial cells of renal tubule, tubular degeneration, necrosis, shrinkage and luminal occlusion were observed. According to the results the most alteration due to exposure to LAS was seen in the gill tissue. None of the control samples showed histological effects of LAS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The three effectiveness measures based on the ability of a flow to flush buoyancy from a ventilated space proposed by Coffey and Hunt [Ventilation effectiveness measures based on heat removal-part 1. Definitions. Building and Environment, in press, doi:10.1016/j.buildenv.2006.03.016.] are applied to assess and compare two fundamental natural ventilation flows. We focus on the limiting cases of passive displacement and passive mixing ventilation flows during transient conditions. These transient flows occur when, for example, heat is purged from a building at night. Whilst it is widely recognised that mixing flows are less efficient at purging heat than displacement flows, our results indicate that, when a particular zone of a room is considered, displacement ventilation can result in lower effectiveness than mixing ventilation. When a room is considered as a whole, displacement ventilation yields higher effectiveness than mixing ventilation and we quantify these differences in terms of the geometry of the space and opening area. The proposed theoretical predictions are compared with effectiveness deduced from measurements made during laboratory experiments and show good agreement. © 2006 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effectiveness of ventilation flows is considered from the perspective of buoyancy (or heat) removal from a space. This perspective is distinct from the standard in which the effectiveness is based on the concentrations of a neutrally buoyant contaminant/passive tracer. Three new measures of effectiveness are proposed based on the ability of a flow to flush buoyancy from a ventilated space. These measures provide estimates of instantaneous and time-averaged effectiveness for the entire space, and local effectiveness at any height of interest. From a generalisation of the latter, a vertical profile of effectiveness is defined. These measures enable quantitative comparisons to be made between different flows and they are applicable when there is a difference in density (as is typical due to temperature differences) between the interior environment and the replacement air. Applications, therefore, include natural ventilation, hybrid ventilation and a range of forced ventilation flows. Finally, we demonstrate how the ventilation effectiveness of a room may be assessed from simple traces of temperature versus time. © 2006 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New measures for estimating the efficiency of transient ventilation flows are proposed. These measures are developed by considering how effectively a ventilation system removes buoyancy from a space. This approach is distinct from standard efficiency measures which are, in general, based on the removal of a neutrally-buoyant passive tracer. Our new measures, based on (active) buoyancy removal, allow both the instantaneous and time-averaged efficiency of the entire space, or of any region within it, to be determined. In addition, expressions for determining vertical profiles of efficiency are proposed. These new measures enable the effectiveness of different flows to be compared directly and are applicable providing density (temperature) differences exist between the interior environment and the replacement air. Thus, they may be used to contrast the effectiveness of a broad range of building ventilation flows including natural, hybrid and forced ventilation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We examine the time taken to flush pollutants from a naturally ventilated room. A simple theoretical model is developed to predict the time taken for neutrally-buoyant pollutants to be removed from a room by a flow driven by localised heat inputs; both line and point heat sources are considered. We show that the rate of flushing is a function of the room volume, vent areas ( A) and the distribution, number (n) and strength (B) of the heat sources. We also show that the entire problem can be reduced to a single parameter ( μ) that is a measure of the vent areas, and a dimensionless time ( τ) that is a function of B, V and μ. Small-scale salt-bath experiments were conducted to measure the flushing rates in order to validate our modelling assumptions and predictions. The predicted flushing times show good agreement with the experiments over a wide range of μ. We apply our model to a typical open plan office and lecture theatre and discuss some of the implications of our results. © 2005 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surface states in semiconductor nanowires (NWs) are detrimental to the NW optical and electronic properties and to their light emission-based applications, due to the large surface-to-volume ratio of NWs and the congregation of defects states near surfaces. In this paper, we demonstrated an effective approach to eliminate surface states in InAs NWs of zinc-blende (ZB) and wurtzite (WZ) structures and a dramatic recovery of band edge emission through surface passivation with organic sulfide octadecylthiol (ODT). Microphotoluminescence (PL) measurements were carried out before and after passivation to study the dominant recombination mechanisms and surface state densities of the NWs. For WZ-NWs, we show that the passivation removed the surface states and recovered the band-edge emission, leading to a factor of ∼19 reduction of PL linewidth. For ZB-NWs, the deep surface states were removed and the PL peaks width became as narrow as ∼250 nm with some remaining emission of near band-edge surface states. The passivated NWs showed excellent stability in atmosphere, water, and heat environments. In particular, no observable changes occurred in the PL features from the passivated NWs exposed in air for more than five months.