859 resultados para Point-of-care systems


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rigid lenses, which were originally made from glass (between 1888 and 1940) and later from polymethyl methacrylate or silicone acrylate materials, are uncomfortable to wear and are now seldom fitted to new patients. Contact lenses became a popular mode of ophthalmic refractive error correction following the discovery of the first hydrogel material – hydroxyethyl methacrylate – by Czech chemist Otto Wichterle in 1960. To satisfy the requirements for ocular biocompatibility, contact lenses must be transparent and optically stable (for clear vision), have a low elastic modulus (for good comfort), have a hydrophilic surface (for good wettability), and be permeable to certain metabolites, especially oxygen, to allow for normal corneal metabolism and respiration during lens wear. A major breakthrough in respect of the last of these requirements was the development of silicone hydrogel soft lenses in 1999 and techniques for making the surface hydrophilic. The vast majority of contact lenses distributed worldwide are mass-produced using cast molding, although spin casting is also used. These advanced mass-production techniques have facilitated the frequent disposal of contact lenses, leading to improvements in ocular health and fewer complications. More than one-third of all soft contact lenses sold today are designed to be discarded daily (i.e., ‘daily disposable’ lenses).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of the Sengstaken–Blakemore tube as a life-saving treatment for bleeding oesophageal varices is slowly becoming the least preferred method possibly due to the potential complications associated with its placement. Nursing practice pertaining to the care of this patient group appears ad hoc and reliant on local knowledge and experience as opposed to recognised evidence of best practice. Therefore, this paper focuses on the application of Lewin's transitional change theory used to introduce a change in nursing practice with the application of a guideline to enhance the care of patients with a Sengstaken–Blakemore tube in situ within a general intensive care unit. This method identified some of the complexities surrounding the change process including the driving and restraining forces that must be harnessed and minimised in order for the adoption of change to be successful.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Specialist palliative care, within hospices in particular, has historically led and set the standard for caring for patients at end of life. The focus of this care has been mostly for patients with cancer. More recently, health and social care services have been developing equality of care for all patients approaching end of life. This has mostly been done in the context of a service delivery approach to care whereby services have become increasingly expert in identifying health and social care need and meeting this need with professional services. This model of patient centred care, with the impeccable assessment and treatment of physical, social, psychological and spiritual need, predominantly worked very well for the latter part of the 20th century. Over the last 13 years, however, there have been several international examples of community development approaches to end of life care. The patient centred model of care has limitations when there is a fundamental lack of integrated community policy, development and resourcing. Within this article, we propose a model of care which identifies a person with an illness at the centre of a network which includes inner and outer networks, communities and service delivery organisations. All of these are underpinned by policy development, supporting the overall structure. Adoption of this model would allow individuals, communities, service delivery organisations and policy makers to work together to provide end of life care that enhances value and meaning for people at end of life, both patients and communities alike.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

“Hybrid” hydrogen storage, where hydrogen is stored in both the solid material and as a high pressure gas in the void volume of the tank can improve overall system efficiency by up to 50% compared to either compressed hydrogen or solid materials alone. Thermodynamically, high equilibrium hydrogen pressures in metal–hydrogen systems correspond to low enthalpies of hydrogen absorption–desorption. This decreases the calorimetric effects of the hydride formation–decomposition processes which can assist in achieving high rates of heat exchange during hydrogen loading—removing the bottleneck in achieving low charging times and improving overall hydrogen storage efficiency of large hydrogen stores. Two systems with hydrogenation enthalpies close to −20 kJ/mol H2 were studied to investigate the hydrogenation mechanism and kinetics: CeNi5–D2 and ZrFe2−xAlx (x = 0.02; 0.04; 0.20)–D2. The structure of the intermetallics and their hydrides were studied by in situ neutron powder diffraction at pressures up to 1000 bar and complementary X-ray diffraction. The deuteration of the hexagonal CeNi5 intermetallic resulted in CeNi5D6.3 with a volume expansion of 30.1%. Deuterium absorption filled three different types of interstices, Ce2Ni2 and Ni4 tetrahedra, and Ce2Ni3 half-octahedra and was accompanied by a valence change for Ce. Significant hysteresis was observed between deuterium absorption and desorption which profoundly decreased on a second absorption cycle. For the Al-modified Laves-type C15 ZrFe2−xAlx intermetallics, deuteration showed very fast kinetics of H/D exchange and resulted in a volume increase of the FCC unit cells of 23.5% for ZrFe1.98Al0.02D2.9(1). Deuterium content, hysteresis of H/D uptake and release, unit cell expansion and stability of the hydrides systematically change with the amount of Al content. In the deuteride D atoms exclusively occupy the Zr2(Fe,Al)2 tetrahedra. Observed interatomic distances are Zr–D = 1.98–2.11; (Fe, Al)–D = 1.70–1.75A˚ . Hydrogenation slightly increases the magnetic moment of the Fe atoms in ZrFe1.98Al0.02 and ZrFe1.96Al0.04 from 1.9 �B at room temperature for the alloy to 2.2 �B for its deuteride.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Musculoskeletal health can be compromised by breast cancer treatment. In particular, bone loss and arthralgias are prevalent side effects experienced by women treated with chemotherapy and/or adjuvant endocrine therapy. Bone loss leads to osteoporosis and related fractures, while arthralgias threaten quality of life and compliance to treatment. Because the processes that lead to these musculoskeletal problems are initiated when treatment begins, early identification of women who may be at higher risk of developing problems, routine monitoring of bone density and pain at certain stages of treatment, and prudent application of therapeutic interventions are key to preventing and/or minimizing musculoskeletal sequelae. Exercise may be a particularly suitable intervention strategy because of its potential to address a number of impairments; it may slow bone loss, appears to reduce joint pain in noncancer conditions, and improves other breast cancer outcomes. Research efforts continue in the areas of etiology, measurement, and treatment of bone loss and arthralgias. The purpose of this review is to provide an overview of the current knowledge on the management and treatment of bone loss and arthralgias in breast cancer survivors and to present a framework for rehabilitation care to preserve musculoskeletal health in women treated for breast cancer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims To provide the best available evidence to determine the impact of nurse practitioner services on cost, quality of care, satisfaction and waiting times in the emergency department for adult patients. Background The delivery of quality care in the emergency department is one of the most important service indicators in health delivery. Increasing service pressures in the emergency department have resulted in the adoption of service innovation models: the most common and rapidly expanding of these is emergency nurse practitioner services. The rapid uptake of emergency nurse practitioner service in Australia has outpaced the capacity to evaluate this service model in terms of outcomes related to safety and quality of patient care. Previous research is now outdated and not commensurate with the changing domain of delivering emergency care with nurse practitioner services. Data A comprehensive search of four electronic databases from 2006-­‐2013 was conducted to identify research evaluating nurse practitioner service impact in the emergency department. English language articles were sought using MEDLINE, CINAHL, Embase and Cochrane and included two previous systematic reviews completed five and seven years ago. Methods A three step approach was used. Following a comprehensive search, two reviewers assessed identified studies against the inclusion criteria. From the original 1013 studies, 14 papers were retained for critical appraisal on methodological quality by two independent reviewers and data extracted using standardised tools. Results Narrative synthesis was conducted to summarise and report the findings as insufficient data was available for meta-­‐analysis of results. This systematic review has shown that emergency nurse practitioner service has a positive impact on quality of care, patient satisfaction and waiting times. There was insufficient evidence to draw conclusions regarding impact on costs. Conclusion Synthesis of the available research attempts to provide an evidence base for emergency nurse practitioner service to guide healthcare leaders, policy makers and clinicians in reforming emergency department service provision. The findings suggest that further quality research is required for comparative measures of clinical and service effectiveness of emergency nurse practitioner service. In the context of increased health service demand and the need to provide timely and effective care to patients, such measures will assist in delivering quality patient care.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

These lecture notes highlight some of the recent applications of multi-objective and multidisciplinary design optimisation in aeronautical design using the framework and methodology described in References 8, 23, 24 and in Part 1 and 2 of the notes. A summary of the methodology is described and the treatment of uncertainties in flight conditions parameters by the HAPEAs software and game strategies is introduced. Several test cases dealing with detailed design and computed with the software are presented and results discussed in section 4 of these notes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Malaria rapid diagnostic tests (RDTs) are increasingly used by remote health personnel with minimal training in laboratory techniques. RDTs must, therefore, be as simple, safe and reliable as possible. Transfer of blood from the patient to the RDT is critical to safety and accuracy, and poses a significant challenge to many users. Blood transfer devices were evaluated for accuracy and precision of volume transferred, safety and ease of use, to identify the most appropriate devices for use with RDTs in routine clinical care. Methods: Five devices, a loop, straw-pipette, calibrated pipette, glass capillary tube, and a new inverted cup device, were evaluated in Nigeria, the Philippines and Uganda. The 227 participating health workers used each device to transfer blood from a simulated finger-prick site to filter paper. For each transfer, the number of attempts required to collect and deposit blood and any spilling of blood during transfer were recorded. Perceptions of ease of use and safety of each device were recorded for each participant. Blood volume transferred was calculated from the area of blood spots deposited on filter paper. Results: The overall mean volumes transferred by devices differed significantly from the target volume of 5 microliters (p < 0.001). The inverted cup (4.6 microliters) most closely approximated the target volume. The glass capillary was excluded from volume analysis as the estimation method used is not compatible with this device. The calibrated pipette accounted for the largest proportion of blood exposures (23/225, 10%); exposures ranged from 2% to 6% for the other four devices. The inverted cup was considered easiest to use in blood collection (206/ 226, 91%); the straw-pipette and calibrated pipette were rated lowest (143/225 [64%] and 135/225 [60%] respectively). Overall, the inverted cup was the most preferred device (72%, 163/227), followed by the loop (61%, 138/227). Conclusions: The performance of blood transfer devices varied in this evaluation of accuracy, blood safety, ease of use, and user preference. The inverted cup design achieved the highest overall performance, while the loop also performed well. These findings have relevance for any point-of-care diagnostics that require blood sampling.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although many studies have discussed Enterprise Resource Planning (ERP) use at the organizational level, no study according to our knowledge, has identified the factors influencing innovative use of ERP by the end users (Sudzina, 2010). This research-in-progress paper describes the preliminary findings of a survey, which is designed to recognize the factors which can influence the end user innovative use of ERP systems. Moreover, this study argues that the innovative use on individual levels could impact the productivity of organizations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Legacy information systems evolved incrementally in response to changes in business strategy and information technology. Organizations are now being forced to change much more radically and quickly than previously and this change places new demands on information systems. Legacy information systems are usually considered from a technical perspective, addressing issues such as age, complexity, maintainability, design and technology. We wish to demonstrate that the business dimension to legacy information systems, represented by the organisation structure, business processes and procedures that are bound up in the design and operation of the existing IT systems, is also significant. This paper identifies the important role of legacy information systems in the formation of new strategies. We show that the move away from a stable to an unstable business environment accelerates the rate of change. Furthermore, the gap between what the legacy information systems can deliver and the strategic vision of the organization widens when the legacy information systems are unable to adapt to meet the new requirements. An analysis of fifteen case studies provides evidence that legacy information systems include business and technical dimensions and that the systems can present problems when there is a misalignment between the strategic vision of the business, the IT legacy and the old business model embodied in the legacy.