913 resultados para Physiochemical measurements


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Most studies assess the prevalence of hypertension in pediatric populations based on blood pressure (BP) readings taken on a single visit. We determined the prevalence of hypertension measured on up to three visits in a Swiss pediatric population and examined the association between hypertension and overweight and selected other factors. METHODS: Anthropometric data and BP were measured in all children of the sixth school grade of the Vaud canton (Switzerland) in 2005-2006. 'Elevated BP' was defined according to sex-specific, age-specific and height-specific US reference data. BP was measured on up to two additional visits in children with elevated BP. 'Hypertension' was defined as 'elevated BP' on all three visits. RESULTS: Out of 6873 children, 5207 (76%) participated [2621 boys, 2586 girls; mean (SD) age, 12.3 (0.5) years]. The prevalence of elevated BP was 11.4, 3.8 and 2.2% on first, second and thirds visits, respectively; hence 2.2% had hypertension. Among hypertensive children, 81% had isolated systolic hypertension. Hypertension was associated with excess body weight, elevated heart rate and parents' history of hypertension. Of the children, 16.1% of boys and 12.4% of girls were overweight or obese (CDC criteria, body mass index >or= 85th percentile). Thirty-seven percent of cases of hypertension could be attributed to overweight or obesity. CONCLUSIONS: The proportion of children with elevated BP based on one visit was five times higher than based on three measurements taken at few-week intervals. Our data re-emphasize the need for prevention and control of overweight in children to curb the global hypertension burden.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes the use of an autonomous assistant mobile robot in order to monitor the environmental conditions of a large indoor area and develop an ambient intelligence application. The mobile robot uses single high performance embedded sensors in order to collect and geo-reference environmental information such as ambient temperature, air velocity and orientation and gas concentration. The data collected with the assistant mobile robot is analyzed in order to detect unusual measurements or discrepancies and develop focused corrective ambient actions. This paper shows an example of the measurements performed in a research facility which have enabled the detection and location of an uncomfortable temperature profile inside an office of the research facility. The ambient intelligent application has been developed by performing some localized ambient measurements that have been analyzed in order to propose some ambient actuations to correct the uncomfortable temperature profile.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tässä työssä on esitetty väsyttävän kuormituksen mittaamiseen ja mittausdatan jälkikäsittelyyn sekä väsymismitoitukseen liittyviä menetelmiä. Menetelmien sovelluskohteena oli metsäkoneen kuormain, joka on väsyttävästi kuormitettu hitsattu rakenne. Teoriaosassa on kuvattu väsymisilmiötä ja väsymismitoitusmenetelmiä sekä kuormitusten tunnistamiseen ja mittausten jälkikäsittelyyn liittyviä menetelmiä. Yleisimmin käytettyjen väsymismitoitusmenetelmien rinnalle on esitetty luotettavuuteen perustuvaa väsymismitoitusmenetelmää. Kuormainten suunnittelussa on keveys- j a kestoikävaatimusten takia erityisen suuri merkitys väsymisen huomioimisella. Rakenteille on ominaista tietyt toiminnan kannalta välttämättömät hitsatut yksityiskohdat, jotka usein määräävät koko rakenteen kestoiän. Koska nämä ongelmakohdat pystytään useimmiten tunnistamaan jo suunnitteluvaiheessa, voidaan yksityiskohtien muotoilulla usein parantaa huomattavasti koko rakenteen kestoikää. Näiden yksityiskohtien optimointi on osittain mahdollista toteuttaa ilman kuormituskertymätietoa, mutta useimmiten kuormitusten tunnistaminen on edellytys parhaan ratkaisun löytymiselle. Tällöin toistaiseksi paras keino todellisen väsyttävän kuormituksen tunnistamiseksi on pitkäaikaiset kenttämittaukset. Kenttämittauksilla selvitetään rakenteeseen kohdistuvat kuormitukset venymäliuskojen avulla. Kuormitusten tunnistamisella on erityisen suuri merkitys kun halutaan määrittää rakenteen kestoikä. Väsyminen ja väsyttävä kuormitus ovat kuitenkin tilastollisia muuttujia j a yksittäiselle rakenteelle ei ole mahdollista määrittää tarkkaa k estoikää. Tilastollisia menetelmiä käyttäen on kuitenkin mahdollista määrittää rakenteen vaurioitumisriski. Laskettaessa vaurioitumisriskiä suurelle määrälle yksittäisiä rakenteita voidaan muodostaa tarkkojakin ennusteita mahdollisten vaurioiden lukumäärästä. Tällöin kuormituskertymätiedosta voi olla tavanomaisen suunnittelun lisäksi laajempaa hyötyä esimerkiksi takuukäsittelyssä. Tässä työssä on sovellettu esitettyjä teorioita käytännössä metsäkoneen harvesterin puomiston väsymistarkasteluun. Kyseisen rakenteen kuormituksia mitattiin kahden viikon aikana yhteensä 35 tuntia, jonka perusteella laskettiin väsyttävän kuormituksen tilastollinen jakauma esimerkkitapaukselle. Mittauksen perusteella ei voitu tehdä kuitenkaan johtopäätöksiä tuotteen koko elinkaaren kuormituksista eikä muiden samanlaisten tuotteiden kuormituksista, koska mitattu otos oli suhteellisen lyhyt ja rajoittui vain yhteen käyttäjään ja muutamaan käyttökohteeseen. Menetelmien testaamiseksi kyseinen otos oli kuitenkin riittävä. Kuormituskertymätietoa käytettiin hyväksi myös laatumääritysten muodostamisessaesimerkkitapaukselle. Murtumismekaniikkaan perustuvalla menetelmällä arvioitiinharvesteripilarin valun mahdollisten valuvirheiden suurin sallittu koko. Luotettavuuteen pohjautuvan mitoitusmenettelyn tarve näyttää olevanlisääntymässä, joten pitkäaikaisten kenttämittausten tehokas hyödyntäminen tulee olemaan keskeinen osa väsymismitoitusta lähitulevaisuudessa. Menetelmiä olisi mahdollista tehostaa yhdistämällä kuormituskertymään erilaisia kuormitusten suhteen riippuvia tunnettuja suureita kuten käsiteltävän puun halkaisija. Todellisettuotekohtaiset tilastolliset jakaumat kuormituksista voitaisiin muodostaa mahdollisesti tehokkaammin, jos esimerkiksi kuormitusten riippuvuus metsätyypistä pystyttäisiin ensin määrittämään.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the evaluation results of the methods submitted to Challenge US: Biometric Measurements from Fetal Ultrasound Images, a segmentation challenge held at the IEEE International Symposium on Biomedical Imaging 2012. The challenge was set to compare and evaluate current fetal ultrasound image segmentation methods. It consisted of automatically segmenting fetal anatomical structures to measure standard obstetric biometric parameters, from 2D fetal ultrasound images taken on fetuses at different gestational ages (21 weeks, 28 weeks, and 33 weeks) and with varying image quality to reflect data encountered in real clinical environments. Four independent sub-challenges were proposed, according to the objects of interest measured in clinical practice: abdomen, head, femur, and whole fetus. Five teams participated in the head sub-challenge and two teams in the femur sub-challenge, including one team who tackled both. Nobody attempted the abdomen and whole fetus sub-challenges. The challenge goals were two-fold and the participants were asked to submit the segmentation results as well as the measurements derived from the segmented objects. Extensive quantitative (region-based, distance-based, and Bland-Altman measurements) and qualitative evaluation was performed to compare the results from a representative selection of current methods submitted to the challenge. Several experts (three for the head sub-challenge and two for the femur sub-challenge), with different degrees of expertise, manually delineated the objects of interest to define the ground truth used within the evaluation framework. For the head sub-challenge, several groups produced results that could be potentially used in clinical settings, with comparable performance to manual delineations. The femur sub-challenge had inferior performance to the head sub-challenge due to the fact that it is a harder segmentation problem and that the techniques presented relied more on the femur's appearance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PAH (N-(4-aminobenzoyl)glycin) clearance measurements have been used for 50 years in clinical research for the determination of renal plasma flow. The quantitation of PAH in plasma or urine is generally performed by colorimetric method after diazotation reaction but the measurements must be corrected for the unspecific residual response observed in blank plasma. We have developed a HPLC method to specifically determine PAH and its metabolite NAc-PAH using a gradient elution ion-pair reversed-phase chromatography with UV detection at 273 and 265 nm, respectively. The separations were performed at room temperature on a ChromCart (125 mmx4 mm I.D.) Nucleosil 100-5 microm C18AB cartridge column, using a gradient elution of MeOH-buffer pH 3.9 1:99-->15:85 over 15 min. The pH 3.9 buffered aqueous solution consisted in a mixture of 375 ml sodium citrate-citric acid solution (21.01 g citric acid and 8.0 g NaOH per liter), added up with 2.7 ml H3PO4 85%, 1.0 g of sodium heptanesulfonate and completed ad 1000 ml with ultrapure water. The N-acetyltransferase activity does not seem to notably affect PAH clearances, although NAc-PAH represents 10.2+/-2.7% of PAH excreted unchanged in 12 healthy subjects. The performance of the HPLC and the colorimetric method have been compared using urine and plasma samples collected from healthy volunteers. Good correlations (r=0.94 and 0.97, for plasma and urine, respectively) are found between the results obtained with both techniques. However, the colorimetric method gives higher concentrations of PAH in urine and lower concentrations in plasma than those determined by HPLC. Hence, both renal (ClR) and systemic (Cls) clearances are systematically higher (35.1 and 17.8%, respectively) with the colorimetric method. The fraction of PAH excreted by the kidney ClR/ClS calculated from HPLC data (n=143) is, as expected, always <1 (mean=0.73+/-0.11), whereas the colorimetric method gives a mean extraction ratio of 0.87+/-0.13 implying some unphysiological values (>1). In conclusion, HPLC not only enables the simultaneous quantitation of PAH and NAc-PAH, but may also provide more accurate and precise PAH clearance measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Regression equations predicting dissectable muscle weight in rabbits from external measurements were presented. Bone weight and weight of muscle groups were also carcass predicted. Predictive capacity of external measurements, retail cuts and muscle groups on total muscle, percent muscle, total bone and muscle to bone ratio were studied separately. Measurements on dissected retail cuts should be included in ordcr to obtain good equations for prediction of percent muscle in the carcass. Equations for predicting the muscle to bone ratio using external mcasurcments and data from the dissection of one hind leg were suggested. The equations had generally high coefficients of determination. The coefficient of determination for prediction of dissectable muscle was 0.91, and for percent muscle in the carcass 0.79.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tässä diplomityössä tavoitteena on selvittää käytännöt ja menetelmät, joilla UPM-Kymmenen sellu-, paperi- ja vaneritehtaat ympäri maailman mittaavat ja laskevat ilmapäästönsä. Tämä tehdään kyselylomakkeella, joka lähetetään tehtaiden ympäristöpäälliköille. Kaikki tärkeimmät seikat ilmapäästöihin liittyen, kuten vaaditut jatkuvatoimiset mittaukset, jaksottaiset mittaukset, raportointikäytäntö, kalibrointi jne. kysytään lomakkeessa. Kyselylomakkeessa painotetaan mittauskäytäntöä sellutehtaissa sekä energiantuotannossa. Saatujen tulosten perusteella annetaan ehdotuksia sekä ohjeita tulevaisuutta varten, jotta mittaustulosten kokoaminen helpottuisi ja vertailukelpoisuus paranisi. Työn kirjallisuusosuudessa selvitetään yleisimmät päästölähteet sekä päästökomponentit paperi –ja selluteollisuudessa. Näiden ei toivottujen yhdisteiden syntymekanismit sekä menetelmät niiden poistamiseksi savukaasuista on myös lyhyesti kuvailtu. Myös erilaiset analysointi- ja näytteenottomenetelmät on kerrottu. Erot tehtaiden ympäristöluvissa käydään läpi, jakaen tehtaat kolmeen maantieteelliseen ryhmään. Lupakäytäntöjen osalta Suomen osuutta on painotettu, sillä UPM-Kymmene on varsin Suomikeskeinen yhtiö tehtaiden lukumääriin ja sijainteihin katsottuna. Viranomaismääräykset sekä päästörajat muutamista tehtaista on esitetty havainnollistaakseen alueellisia eroja.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The avidity of the T-cell receptor (TCR) for antigenic peptides presented by the peptide-MHC (pMHC) on cells is a key parameter for cell-mediated immunity. Yet a fundamental feature of most tumor antigen-specific CD8(+) T cells is that this avidity is low. In this study, we addressed the need to identify and select tumor-specific CD8(+) T cells of highest avidity, which are of the greatest interest for adoptive cell therapy in patients with cancer. To identify these rare cells, we developed a peptide-MHC multimer technology, which uses reversible Ni(2+)-nitrilotriacetic acid histidine tags (NTAmers). NTAmers are highly stable but upon imidazole addition, they decay rapidly to pMHC monomers, allowing flow-cytometric-based measurements of monomeric TCR-pMHC dissociation rates of living CD8(+) T cells on a wide avidity spectrum. We documented strong correlations between NTAmer kinetic results and those obtained by surface plasmon resonance. Using NTAmers that were deficient for CD8 binding to pMHC, we found that CD8 itself stabilized the TCR-pMHC complex, prolonging the dissociation half-life several fold. Notably, our NTAmer technology accurately predicted the function of large panels of tumor-specific T cells that were isolated prospectively from patients with cancer. Overall, our results demonstrated that NTAmers are effective tools to isolate rare high-avidity cytotoxic T cells from patients for use in adoptive therapies for cancer treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT Dual-trap optical tweezers are often used in high-resolution measurements in single-molecule biophysics. Such measurements can be hindered by the presence of extraneous noise sources, the most prominent of which is the coupling of fluctuations along different spatial directions, which may affect any optical tweezers setup. In this article, we analyze, both from the theoretical and the experimental points of view, the most common source for these couplings in dual-trap optical-tweezers setups: the misalignment of traps and tether. We give criteria to distinguish different kinds of misalignment, to estimate their quantitative relevance and to include them in the data analysis. The experimental data is obtained in a, to our knowledge, novel dual-trap optical-tweezers setup that directly measures forces. In the case in which misalignment is negligible, we provide a method to measure the stiffness of traps and tether based on variance analysis. This method can be seen as a calibration technique valid beyond the linear trap region. Our analysis is then employed to measure the persistence length of dsDNA tethers of three different lengths spanning two orders of magnitude. The effective persistence length of such tethers is shown to decrease with the contour length, in accordance with previous studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Mitogen activated protein kinases (MAPK) play an essential role in integrating extra-cellular signals and intra-cellular cues to allow cells to grow, adapt to stresses, or undergo apoptosis. Budding yeast serves as a powerful system to understand the fundamental regulatory mechanisms that allow these pathways to combine multiple signals and deliver an appropriate response. To fully comprehend the variability and dynamics of these signaling cascades, dynamic and quantitative single cell measurements are required. Microscopy is an ideal technique to obtain these data; however, novel assays have to be developed to measure the activity of these cascades. RESULTS: We have generated fluorescent biosensors that allow the real-time measurement of kinase activity at the single cell level. Here, synthetic MAPK substrates were engineered to undergo nuclear-to-cytoplasmic relocation upon phosphorylation of a nuclear localization sequence. Combination of fluorescence microscopy and automated image analysis allows the quantification of the dynamics of kinase activity in hundreds of single cells. A large heterogeneity in the dynamics of MAPK activity between individual cells was measured. The variability in the mating pathway can be accounted for by differences in cell cycle stage, while, in the cell wall integrity pathway, the response to cell wall stress is independent of cell cycle stage. CONCLUSIONS: These synthetic kinase activity relocation sensors allow the quantification of kinase activity in live single cells. The modularity of the architecture of these reporters will allow their application in many other signaling cascades. These measurements will allow to uncover new dynamic behaviour that previously could not be observed in population level measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This editorial discusses the role of serial measurements of fecal calprotectin or fecal lactoferrin for the early detection of pouchitis in patients with ulcerative colitis having undergone procto-colectomy with ileo-pouch-anal anastomosis. Furthermore, the role of fecal calprotectin and fecal lactoferrin for the monitoring of pouchitis is highlighted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

STUDY DESIGN: Clinical measurement. PURPOSE: The test-retest reliability of maximal grip strength measurements (MGSM) is examined in subjects for 12 weeks post-stroke together with maximal grip strength recovery and the maximal-grip and upper-extremity strength measurements' relationship with capacity and performance test scores. METHODS: A Jamar dynamometer and the Motricity Index (MI) were used for strength measurements. The Chedoke Arm and Hand Activity Inventory and ABILHAND questionnaire for evaluating capacities and performances. RESULTS: MGSM were reliable (Intraclass Correlation Coefficients = 0.97-0.99, Minimal Detectable Differences = 2.73-4.68 kg). Among the 34 participants, 47% did not have a measurable grip strength one week post-stroke but 50% of these recovered some strength within the first eight weeks. The MGSM and MI scores were correlated with scores of tests of capacity and performance (Spearman's Rank Correlation Coefficients = 0.69-0.94). CONCLUSIONS: MGSM are reliable in the first weeks after a stroke. LEVEL OF EVIDENCE: N/A.