976 resultados para Peri-implant bone fenestration


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To assess the bleeding on probing (BOP) tendency and periodontal probe penetration when applying various probing forces at implant sites in patients with a high standard of oral hygiene with well-maintained peri-implant tissues. MATERIAL AND METHODS: Seventeen healthy patients with excellent oral hygiene in a maintenance program after having been treated for periodontitis or gingivitis were recruited. Missing teeth had been replaced using oral implants. The BOP and probing depth (PPD) were assessed at the mid-buccal, mid-oral, mesial and distal aspects of the buccal surfaces of each implant. Moreover, contralateral teeth were designated and assessed for BOP and PPD in the same locations and at the same observation visits. At each visit, implants and contralateral teeth were randomly assigned to one of the standardized probing forces (0.15 or 0.25 N). The second probing force was applied at the repetition of the examination 7 days later. RESULTS: Increasing the probing pressure by 0.1 N from 0.15 N resulted in an increase of BOP percentage by 13.7% and 6.6% for implants and contralateral teeth, respectively. There appeared to be a significant difference of the mean BOP percentage at implant and tooth sites when a probing pressure of 0.25 N was applied. A significantly deeper mean PPD at implant sites compared with tooth sites was found irrespective of the probing pressure applied. CONCLUSIONS: The results of the present study demonstrated that 0.15 N might represent the threshold pressure to be applied to avoid false positive BOP readings around oral implants. Hence, probing around implants demonstrated a higher sensitivity compared with probing around teeth.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To systematically review the current literature on the maxillary midline frenum and associated conditions and complications, as well as the recommended treatment options. METHOD AND MATERIALS A detailed MEDLINE database search was carried out to provide evidence about the epidemiology, associated pathologies, and treatment options regarding the maxillary frenum. Of the 206 initially identified articles, 48 met the inclusion criteria. RESULTS The maxillary frenum is highly associated with a number of syndromes and developmental abnormalities. A hypertrophic frenum may be involved in the etiology of the midline diastema. There is also a tendency by orthodontists to suggest posttreatment removal of the frenum (frenectomy). Studies on the cause of gingival recession due to the maxillary frenum are inconclusive. An injured frenum in combination with other traumas and doubtful history might point to child abuse. The involvement of hyperplastic frena in the pathogenesis of peri-implant diseases remains uncertain. There seems to be a clinical interest regarding lasers for surgery for treatment of maxillary frena. The superiority of laser treatment in relation to conventional surgical methods has not yet been demonstrated in the literature. CONCLUSION A maxillary frenum is a clinical symptom in numerous syndromic conditions and plays a role in the development of the median midline diastema. Nevertheless, the contribution to gingival recession and peri-implant diseases in the region of the maxillary incisors is rather controversial. Laser techniques are reported as the method of choice for the surgical removal of frena; however, this needs to be substantiated by appropriate prospective controlled studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Study Design. An experimental animal study. Objective. To investigate histomorphometric and radiographical changes in the BB.4S rat model after PEEK (polyetheretherketone) nonfusion interspinous device implantation. Summary of Background Data. Clinical effectiveness of the PEEK nonfusion spine implant Wallis (Abbott, Bordeaux, France; now Zimmer, Warsaw, IN) is well documented. However, there is a lack of evidence on the long-term effects of this implant on bone, in particular its influence on structural changes of bone elements of the lumbar spine. Methods. Twenty-four male BB.4S rats aged 11 weeks underwent surgery for implantation of a PEEK nonfusion interspinous device or for a sham procedure in 3 groups of 8 animals each: 1) implantation at level L4–L5; 2) implantation at level L5–L6; and 3) sham surgery. Eleven weeks postoperatively osteolyses at the implant-bone interface were measured via radiograph, bone mineral density of vertebral bodies was analyzed using osteodensitometry, and bone mineral content as well as resorption of the spinous processes were examined by histomorphometry. Results. Resorption of the spinous processes at the site of the interspinous implant was found in all treated segments. There was no significant difference in either bone density of vertebral bodies or histomorphometric structure of the spinous processes between adjacent vertebral bodies, between treated and untreated segments and between groups. Conclusion. These findings indicate that resorption of spinous processes because of a result of implant loosening, inhibit the targeted load redistribution through the PEEK nonfusion interspinous device in the lumbar spinal segment of the rat. This leads to reduced long-term stability of the implant in the animal model. These results suggest that PEEK nonfusion interspinous devices like the Wallis implants may have time-limited effects and should only be used for specified indications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM To provide an overview on the biology and soft tissue wound healing around teeth and dental implants. MATERIAL AND METHODS This narrative review focuses on cell biology and histology of soft tissue wounds around natural teeth and dental implants. RESULTS AND CONCLUSIONS The available data indicate that: (a) Oral wounds follow a similar pattern. (b) The tissue specificities of the gingival, alveolar and palatal mucosa appear to be innately and not necessarily functionally determined. (c) The granulation tissue originating from the periodontal ligament or from connective tissue originally covered by keratinized epithelium has the potential to induce keratinization. However, it also appears that deep palatal connective tissue may not have the same potential to induce keratinization as the palatal connective tissue originating from an immediately subepithelial area. (d) Epithelial healing following non-surgical and surgical periodontal therapy appears to be completed after a period of 7–14 days. Structural integrity of a maturing wound between a denuded root surface and a soft tissue flap is achieved at approximately 14-days post-surgery. (e) The formation of the biological width and maturation of the barrier function around transmucosal implants requires 6–8 weeks of healing. (f) The established peri-implant soft connective tissue resembles a scar tissue in composition, fibre orientation, and vasculature. (g) The peri-implant junctional epithelium may reach a greater final length under certain conditions such as implants placed into fresh extraction sockets versus conventional implant procedures in healed sites.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Scientific data and clinical observations appear to indicate that an adequate width of attached mucosa may facilitate oral hygiene procedures thus preventing peri-implant inflammation and tissue breakdown (eg, biologic complications). Consequently, in order to avoid biologic complications and improve long-term prognosis, soft tissue conditions should be carefully evaluated when implant therapy is planned. At present the necessity and time-point for soft tissue grafting (eg, prior to or during implant placement or after healing) is still controversially discussed while clinical recommendations are vague. OBJECTIVES To provide a review of the literature on the role of attached mucosa to maintain periimplant health, and to propose a decision tree which may help the clinician to select the appropriate surgical technique for increasing the width of attached mucosa. RESULTS The available data indicate that ideally, soft tissue conditions should be optimized by various grafting procedures either before or during implant placement or as part of stage-two surgery. In cases, where, despite insufficient peri-implant soft tissue condition (ie, lack of attached mucosa or movements caused by buccal frena), implants have been uncovered and/or loaded, or in cases where biologic complications are already present (eg, mucositis, peri-implantitis), the treatment appears to be more difficult and less predictable. CONCLUSION Soft tissue grafting may be important to prevent peri-implant tissue breakdown and should be considered when dental implants are placed. The presented decision tree may help the clinician to select the appropriate grafting technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE To compare the initial stability and stability after fatigue of three different locking systems (Synthes(®), Stryker(®) and Medartis(®)) for mandibular fixation and reconstruction. METHOD Standard mandible locking plates with identical profile height (1,5 mm), comparable length and screws with identical diameter (2,0 mm) were used. Plates were fixed with six screws according a preparation protocol. Four point bending tests were then performed using artificial bone material to compare their initial stability and failure limit under realistic loading conditions. Loading of the plates was performed using of a servo hydraulic driven testing machine. The stiffness of the implant/bone construct was calculated using a linear regression on the experimental data included in a range of applied moment between 2 Nm and 6 Nm. RESULTS No statistical difference in the elastic stiffness was visible between the three types of plate. However, differences were observed between the systems concerning the maximal load supported. The Stryker and Synthes systems were able to support a significantly higher moment. CONCLUSION For clinical application all systems show good and reliable results. Practical aspects such as handling, possible angulation of screw fixation, possibility of screw/plate removal, etc. may favour one or the other plating system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To determine the microbiota at implants and adjacent teeth 10 years after placement of implants with a sandblasted and acid-etched surface. MATERIAL AND METHODS Plaque samples obtained from the deepest sites of 504 implants and of 493 adjacent teeth were analyzed for certain bacterial species associated with periodontitis, for staphylococci, for aerobic gram-negative rods, and for yeasts using nucleic acid-based methods. RESULTS Species known to be associated with periodontitis were detectable at 6.2-78.4% of the implants. Significantly higher counts at implants in comparison with teeth were assessed for Tannerella forsythia, Parvimonas micra, Fusobacterium nucleatum/necrophorum, and Campylobacter rectus. Higher counts of periodontopathogenic species were detectable at implants of current smokers than at those of non-smokers. In addition, those species were found in higher quantities at implants of subjects with periodontitis. The prevalence of Prevotella intermedia, Treponema denticola, C. rectus, and moreover of Staphylococcus warneri might be associated with peri-implant inflammation. Selected staphylococcal species (not Staphylococcus aureus), aerobic gram-negative rods, and yeasts were frequently detected, but with the exception of S. warneri, they did not show any association with periodontal or peri-implant diseases. CONCLUSIONS Smoking and periodontal disease are risk factors for colonization of periodontopathic bacteria at implants. Those bacterial species may play a potential role in peri-implant inflammation. The role of S. warneri needs further validation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES To assess a selection of host-derived biomarkers in peri-implant sulcus fluid (PISF) and gingival crevicular fluid (GCF) from adjacent teeth 10 years following implant placement. MATERIAL AND METHODS Peri-implant sulcus fluid and GCF samples obtained from the deepest sites of 504 implants and 493 adjacent teeth were analysed for levels of interleukin (IL)-1β, matrix metalloproteinase (MMP)-3, MMP-8, MMP-1, and MMP-1 bound to tissue inhibitor of MMP (TIMP)-1 (MMP-1/TIMP-1) by enzyme-linked immunosorbent assay (ELISA) technique. RESULTS Overall, MMP-8 was detected in 90% of the sites. In more than 50% of the sites, IL-1β was identified while in 30% of the sites MMP-1, MMP-1/TIMP-1 and MMP-3 were found over the detection level. Increased biomarkers levels from PISF and GCF were positively correlated (r = 0.375-0.702; P < 0.001). However, no qualitative and quantitative differences were found between PISF and GCF. The levels of MMP-1 were negatively correlated with those of MMP-1/TIMP-1 at implants (r = -0.644; P < 0.001). Median MMP-1 levels at implants were high (5.17 pg/site) in subjects with severe chronic periodontitis and low in patients with mild-to-moderate chronic periodontitis (0 pg/site; P = 0.026) or gingivitis (0 pg/site; P = 0.034). Levels of IL-1β were found to be different in GCF according to the periodontal conditions (P = 0.001) with the highest level found in mild-to-moderate periodontitis (6.2 pg/site). Clinical attachment levels at implants demonstrated an inverse correlation with MMP-1/TIMP-1 (r = -0.147; P = 0.001). CONCLUSIONS Increased levels of MMP-8 and IL-1β in PISF or GCF may be associated with inflammation around teeth and implants while lower levels of MMP-1/TIMP-1 may be an indicator of disease progression around implants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Infiltration of organic fluids and microorganisms at the abutment/implant interface may result in bacterial infection of peri-implant tissues. Internal colonization of periodontal pathogens may be caused by bacteria trapped during installation or penetration of abutment/implant leakage. The aim of this study was to detect periodontal pathogens in the internal area of dental implants before loading. Materials and Methods: Seventy-eight implants in 32 partially edentulous subjects were selected for this evaluation. A bacterial biofilm sample of the internal surface of each implant was taken and analyzed for the presence of 40 microorganisms by checkerboard DNA-DNA hybridization, prior to installation of healing or any other prosthetic abutment. Discussion: Bacteria were detected in 20 patients (62.5%), distributed in 41 implants (52.6%). Forty-seven percent of implants showed no bacterial detection. Spontaneous early implant exposure to oral cavity during the healing period was not significant (P >0.05) to increase bacterial prevalence, but implants placed at mandible had higher bacterial prevalence than maxillary ones. Conclusion: The internal surface of dental implants can serve as a reservoir of periodontal pathogens for future implant/abutment interface.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Os tratamentos odontológicos com implantes dentários, têm sido bem documentados nos últimos 40 anos e com grandes sucessos. O implante dentário instalado no local de dentes perdidos deve envolver sempre um correto planejamento pelo médico dentista. Nesta área é muito importante o conhecimento do microbioma que envolve o implante dentário, desde seu planejamento até a reabilitação final. O tempo exato com que o microbioma se forma, assim como, os microrganismos presentes são fundamentais para a correta execução e êxito do implante. Contudo a contaminação interna dos implantes reabilitados, os componentes extracelulares de microrganismos, como as endotoxinas, têm uma enorme influência no sucesso dos implantes. Além disso, o conhecimento das superfícies dos implantes e a relação com a presença microbiana também muito importante. O presente estudo realizou uma revisão bibliográfica sobre o microbioma oral e sua relação com a infecção periimplantar, discutindo diversos estudos, tanto clássicos como atuais. Embora se possa concluir que o microbioma periimplantar é caracterizado pelo microbioma anterior à instalação dos implantes dentários, podemos referir a necessidade de mais estudos de modo a elucidar melhor o planejamento e a longevidade dos tratamentos com implantes dentários.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Objectives: The maintenance and stability of peri-implantar soft tissue seem to be related to the crestal bone around the implant platform and different implant designs connections might affect this phenomenon. The aim of this study was to evaluate by photoelastic analysis the stress distribution in the cervical and apical site of implant-abutment interface of conventional implant joints (external hex, internal hex and cone morse) and compare to the novel platform switching design. Materials and methods: It was fabricated photoelastic models using five different implant-abutment connection, one set of external hex (Alvim Ti, Neodent, Curitiba, Brazil), one set of internal hex (Full Osseotite, Biomet 3i, Florida, USA), one cone morse set (Alvim CM, Neodent, Curitiba, Brazil), and two sets of internal hex plus platform switching concept (Alvim II Plus, Neodent, Curitiba, Brazil) (Certain Prevail, Biomet 3i, Florida, USA). These models were submitted to two compressive loads, axial from 20 kgf (load I) and another (load II), inclined 45° from 10 kgf. During the qualitative analysis, digital pictures were taken from a polariscope, for each load situation. For the quantitative analyses in both situations of load, the medium, minimum and maximum in MPa values of shear strain were determined in the cervical and apical site. The Kruskal-Wallis test was used to compare the results between the different systems and between cervical and apical site were compared using Mann-Whitney U test. Results: The results from qualitative analysis showed less concentration of strain in the cervical area to the internal hex plus platform switching (Certain Prevail), in both situation of load. The same results were get in the quantitative analysis, showing less stress concentrations around the implant Certain Prevail with internal hex plus the novel design (17.9 MPa to load I and 29.5 MPa to load II), however, without statistical significant difference between the systems. Conclusion: The minor stress concentration strongly suggest the use of platform switching design as a manner to prevent bone loss around the implant-abutment platform. Clinical Significance: From the result of this study its possible to make clinical decision for implant system which provides implant components with platform switching characteristics.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

BACKGROUND: Although considerable bone fill may occur following treatment of peri-implantitis, re-osseointegration appears to be limited and unpredictable. Objectives: To evaluate the effects of various decontamination techniques and implant surface configurations on re-osseointegration of contaminated dental implants. MATERIAL AND METHODS: Three months after tooth extraction, implants consisting of a basal part and an exchangeable intraosseous implant cylinder (EIIC) were placed in the mandibles of dogs. The EIIC was machined (M), sandblasted and acid-etched (SLA), or titanium plasma sprayed (TPS). Ligature-induced peri-implantitis was initiated 8 weeks post-implantation and lasted until bone loss reached the junction of the two implant parts. Three treatment modalities were applied: (T1) the EIIC was exchanged for a pristine EIIC; (T2) the EIIC was sprayed in situ with saline; and (T3) the EIIC was removed, cleansed outside the mouth by spraying with saline, steam-sterilized, and remounted. A collagen barrier was placed over each fixture, and 3 months later, samples were processed for histology and histomorphometry. RESULTS: T2 revealed the highest bone-to-implant contact (BIC) level (significantly better than T1 and T3). T2 also yielded the highest bone crest level (significantly better than T1), followed by T3 (significantly better than T1). SLA showed the highest BIC level (significantly better than M), followed by TPS. There were no statistically significant differences in bone crest height between implant types. CONCLUSIONS: Both SLA implants and in situ cleansing resulted in the best re-osseointegration and bone fill of previously contaminated implants.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The objective was to evaluate the influence of dental metallic artefacts on implant sites using multislice and cone-beam computed tomography techniques. Ten dried human mandibles were scanned twice by each technique, with and without dental metallic artefacts. Metallic restorations were placed at the top of the alveolar ridge adjacent to the mental foramen region for the second scanning. Linear measurements (thickness and height) for each cross-section were performed by a single examiner using computer software. All mandibles were analysed at both the right and the left mental foramen regions. For the multislice technique, dental metallic artefact produced an increase of 5% in bone thickness and a reduction of 6% in bone height; no significant differences (p > 0.05) were detected when comparing measurements performed with and without metallic artefacts. With respect to the cone-beam technique, dental metallic artefact produced an increase of 6% in bone thickness and a reduction of 0.68% in bone height. No significant differences (p > 0.05) were observed when comparing measurements performed with and without metallic artefacts. The presence of dental metallic artefacts did not alter the linear measurements obtained with both techniques, although its presence made the location of the alveolar bone crest more difficult.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Reconstruction of defects in the craniomaxillofacial (CMF) area has mainly been based on bone grafts or metallic fixing plates and screws. Particularly in the case of large calvarial and/or craniofacial defects caused by trauma, tumours or congenital malformations, there is a need for reliable reconstruction biomaterials, because bone grafts or metallic fixing systems do not completely fulfill the criteria for the best possible reconstruction methods in these complicated cases. In this series of studies, the usability of fibre-reinforced composite (FRC) was studied as a biostable, nonmetallic alternative material for reconstructing artificially created bone defects in frontal and calvarial areas of rabbits. The experimental part of this work describes the different stages of the product development process from the first in vitro tests with resin-impregnated fibrereinforced composites to the in vivo animal studies, in which this FRC was tested as an implant material for reconstructing different size bone defects in rabbit frontal and calvarial areas. In the first in vitro study, the FRC was polymerised in contact with bone or blood in the laboratory. The polymerised FRC samples were then incubated in water, which was analysed for residual monomer content by using high performance liquid chromatography (HPLC). It was found that this in vitro polymerisation in contact with bone and blood did not markedly increase the residual monomer leaching from the FRC. In the second in vitro study, different adhesive systems were tested in fixing the implant to bone surface. This was done to find an alternative implant fixing system to screws and pins. On the basis of this study, it was found that the surface of the calvarial bone needed both mechanical and chemical treatments before the resinimpregnated FRC could be properly fixed onto it. In three animal studies performed with rabbit frontal bone defects and critical size calvarial bone defect models, biological responses to the FRC implants were evaluated. On the basis of theseevaluations, it can be concluded that the FRC, based on E-glass (electrical glass) fibres forming a porous fibre veil enables the ingrowth of connective tissues to the inner structures of the material, as well as the bone formation and mineralization inside the fibre veil. Bone formation could be enhanced by using bioactive glass granules fixed to the FRC implants. FRC-implanted bone defects healed partly; no total healing of defects was achieved. Biological responses during the follow-up time, at a maximum of 12 weeks, to resin-impregnated composite implant seemed to depend on the polymerization time of the resin matrix of the FRC. Both of the studied resin systems used in the FRC were photopolymerised and the heat-induced postpolymerisation was used additionally.