938 resultados para Percutaneous Ethanol Injection


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dependability is a critical factor in computer systems, requiring high quality validation & verification procedures in the development stage. At the same time, digital devices are getting smaller and access to their internal signals and registers is increasingly complex, requiring innovative debugging methodologies. To address this issue, most recent microprocessors include an on-chip debug (OCD) infrastructure to facilitate common debugging operations. This paper proposes an enhanced OCD infrastructure with the objective of supporting the verification of fault-tolerant mechanisms through fault injection campaigns. This upgraded on-chip debug and fault injection (OCD-FI) infrastructure provides an efficient fault injection mechanism with improved capabilities and dynamic behavior. Preliminary results show that this solution provides flexibility in terms of fault triggering and allows high speed real-time fault injection in memory elements

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fault injection is frequently used for the verification and validation of dependable systems. When targeting real time microprocessor based systems the process becomes significantly more complex. This paper proposes two complementary solutions to improve real time fault injection campaign execution, both in terms of performance and capabilities. The methodology is based on the use of the on-chip debug mechanisms present in modern electronic devices. The main objective is the injection of faults in microprocessor memory elements with minimum delay and intrusiveness. Different configurations were implemented and compared in terms of performance gain and logic overhead.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As electronic devices get smaller and more complex, dependability assurance is becoming fundamental for many mission critical computer based systems. This paper presents a case study on the possibility of using the on-chip debug infrastructures present in most current microprocessors to execute real time fault injection campaigns. The proposed methodology is based on a debugger customized for fault injection and designed for maximum flexibility, and consists of injecting bit-flip type faults on memory elements without modifying or halting the target application. The debugger design is easily portable and applicable to different architectures, providing a flexible and efficient mechanism for verifying and validating fault tolerant components.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rapid increase in the use of microprocessor-based systems in critical areas, where failures imply risks to human lives, to the environment or to expensive equipment, significantly increased the need for dependable systems, able to detect, tolerate and eventually correct faults. The verification and validation of such systems is frequently performed via fault injection, using various forms and techniques. However, as electronic devices get smaller and more complex, controllability and observability issues, and sometimes real time constraints, make it harder to apply most conventional fault injection techniques. This paper proposes a fault injection environment and a scalable methodology to assist the execution of real-time fault injection campaigns, providing enhanced performance and capabilities. Our proposed solutions are based on the use of common and customized on-chip debug (OCD) mechanisms, present in many modern electronic devices, with the main objective of enabling the insertion of faults in microprocessor memory elements with minimum delay and intrusiveness. Different configurations were implemented starting from basic Components Off-The-Shelf (COTS) microprocessors, equipped with real-time OCD infrastructures, to improved solutions based on modified interfaces, and dedicated OCD circuitry that enhance fault injection capabilities and performance. All methodologies and configurations were evaluated and compared concerning performance gain and silicon overhead.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experiments were carried out with Sw albino mice and it was concluded that the percutaneous route via abdominal skin was significatively more efficient than tail immersion method and subcutaneous infection; the subcutaneous injection was significatively more efficient than the percutaneous infection through the tail; this latter and the intraperitoneal injection, resulted in similar infections, but were significatively less efficient than the others. Significative difference was also observed in the comparison between the subcutaneous route and percutaneous infection through ear pinna. The influence of the site of skin infection by percutaneous route was also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fault injection is frequently used for the verification and validation of the fault tolerant features of microprocessors. This paper proposes the modification of a common on-chip debugging (OCD) infrastructure to add fault injection capabilities and improve performance. The proposed solution imposes a very low logic overhead and provides a flexible and efficient mechanism for the execution of fault injection campaigns, being applicable to different target system architectures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We studied the role of ethanol on the modulation of liver granulomata around Schistosoma mansoni eggs in mice. Albino mice, receiving 7% ethanol as the sole drinking liquid, at 60 and 90 days post-infection, presented smaller granulomata than controls did, when sacrificed at 120 days post-infection. No differences in diameters could be observed, when ethanol was given 4 months before up to 120 days after infection. The results suggested that modulation of schistosome granulomata by ethanol ingestion varies with time and duration of drug consumption.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sulfadiazine is an antibiotic of the sulfonamide group and is used as a veterinary drug in fish farming. Monitoring it in the tanks is fundamental to control the applied doses and avoid environmental dissemination. Pursuing this goal, we included a novel potentiometric design in a flow-injection assembly. The electrode body was a stainless steel needle veterinary syringe of 0.8-mm inner diameter. A selective membrane of PVC acted as a sensory surface. Its composition, the length of the electrode, and other flow variables were optimized. The best performance was obtained for sensors of 1.5-cm length and a membrane composition of 33% PVC, 66% onitrophenyloctyl ether, 1% ion exchanger, and a small amount of a cationic additive. It exhibited Nernstian slopes of 61.0 mV decade-1 down to 1.0×10-5 mol L-1, with a limit of detection of 3.1×10-6 mol L-1 in flowing media. All necessary pH/ionic strength adjustments were performed online by merging the sample plug with a buffer carrier of 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, pH 4.9. The sensor exhibited the advantages of a fast response time (less than 15 s), long operational lifetime (60 days), and good selectivity for chloride, nitrite, acetate, tartrate, citrate, and ascorbate. The flow setup was successfully applied to the analysis of aquaculture waters. The analytical results were validated against those obtained with liquid chromatography–tandem mass spectrometry procedures. The sampling rate was about 84 samples per hour and recoveries ranged from 95.9 to 106.9%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The manifestations caused by Africanized bee stings depend on the sensitivity of the victim and the toxicity of the venom. Previous studies in our laboratory have demonstrated cardiac changes and acute tubular necrosis (ATN) in the kidney of rats inoculated with Africanized bee venom (ABV). The aim of the present study was to evaluate the changes in mean arterial pressure (MAP) and heart rate (HR) over a period of 24 h after intravenous injection of ABV in awake rats. A significant reduction in basal HR as well as in basal MAP occurred immediately after ABV injection in the experimental animals. HR was back to basal level 2 min after ABV injection and remained normal during the time course of the experiment, while MAP returned to basal level 10 min later and remained at this level for the next 5 h. However, MAP presented again a significant reduction by the 7th and 8th h and returned to the basal level by the 24th h. The fall in MAP may contribute to the pathogenesis of ATN observed. The fall in MAP probably is due to several factors, in addition to the cardiac changes already demonstrated, it is possible that the components of the venom themselves or even substances released in the organism play some role in vascular beds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cryptococcosis is a worldwide disease caused by the etiological agent Cryptococcus neoformans. It affects mainly immunocompromised humans. It is relatively rare in animals only affecting those that have received prolonged antibiotic therapy. The propolis is a resin that can present several biological properties, including antibacterial, antifungal and antiviral activities. The standard strain C. neoformans ATTC 90112 was used to the antifungal evaluation. The tests were realized with propolis ethanol extract (PEE) G12 in concentrations from 0.1 to 1.6 mg mL-1. The evaluation of MIC and MFC were done according to DUARTE (2002)5. The inhibitory effect of PEE G12 on the fungal growing was seen at the concentration of 0.2 mg mL-1 and 1.6 mg mL-1 was considered a fungicidal one.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: We describe our center's initial experience with alcohol septal ablation (ASA) for the treatment of obstructive hypertrophic cardiomyopathy. The procedure, its indications, results and clinical outcomes will be addressed, as will its current position compared to surgical myectomy. OBJECTIVE: To assess the results of ASA in all patients treated in the first four years of activity at our center. METHODS: We retrospectively studied all consecutive and unselected patients treated by ASA between January 2009 and February 2013. RESULTS: In the first four years of experience 40 patients were treated in our center. In three patients (7.5%) the intervention was repeated. Procedural success was 84%. Minor complications occurred in 7.5%. Two patients received a permanent pacemaker for atrioventricular block (6% of those without previous pacemaker). The major complication rate was 5%. There were no in-hospital deaths; during clinical follow-up (22 ± 14 months) cardiovascular mortality was 2.5% and overall mortality was 5%. DISCUSSION AND CONCLUSION: The results presented reflect the initial experience of our center with ASA. The success rate was high and in line with published results, but with room to improve with better patient selection. ASA was shown to be safe, with a low complication rate and no procedure-related mortality. Our experience confirms ASA as a percutaneous alternative to myectomy for the treatment of symptomatic patients with obstructive hypertrophic cardiomyopathy refractory to medical treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We examined the longitudinal changes of VEGF levels after percutaneous coronary intervention for predicting major adverse cardiac events (MACE) in coronary artery disease (CAD) patients. VEGF was measured in 94 CAD patients' serum before revascularization, 1-month and 1-year after. Independently of clinical presentation, patients had lower VEGF concentration than a cohort of healthy subjects (median, IQ: 15.9, 9.0-264 pg/mL versus 419, 212-758 pg/mL; P < 0.001) at baseline. VEGF increased to 1-month (median, IQ: 276, 167-498 pg/mL; P < 0.001) and remained steady to 1-year (median, IQ: 320, 173-497 pg/mL; P < 0.001) approaching control levels. Drug eluting stent apposition and previous medication intake produced a less steep VEGF evolution after intervention (P < 0.05). Baseline VEGF concentration <40.8 pg/mL conveyed increased risk for MACE in a 5-year follow-up. Results reflect a positive role of VEGF in recovery and support its importance in CAD prognosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Mitral regurgitation (MR) is the most common valvular disease and has recently become the target of a number of percutaneous approaches. The MitraClip is virtually the only device for which there is considerable experience, with more than 20,000 procedures performed worldwide. OBJECTIVE: To describe our initial experience of the percutaneous treatment of MR with the MitraClip device. METHODS: We describe the first six MitraClip cases performed in this institution (mean age 58.5 ± 13.1 years), with functional MR grade 4+ and New York Heart Association (NYHA) heart failure class III or IV (n=3), with a mean follow-up of 290 ± 145 days. RESULTS: Procedural success (MR ≤ 2+) was 100%. Total procedure time was 115.8 ± 23.7 min, with no in-hospital adverse events and discharge between the fourth and eighth day, and consistent improvement in the six-minute walk test (329.8 ± 98.42 vs. 385.33 ± 106.95 m) and in NYHA class (three patients improved by two NYHA classes). During follow-up there were two deaths, in two of the four patients who had been initially considered for heart transplantation. CONCLUSION: In patients with functional MR the MitraClip procedure is safe, with both a high implantation and immediate in-hospital success rate. A longer follow-up suggests that the clinical benefit decreases or disappears completely in patients with more advanced heart disease, namely those denied transplantation or on the heart transplant waiting list.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: New scores have been developed and validated in the US for in-hospital mortality risk stratification in patients undergoing coronary angioplasty: the National Cardiovascular Data Registry (NCDR) risk score and the Mayo Clinic Risk Score (MCRS). We sought to validate these scores in a European population with acute coronary syndrome (ACS) and to compare their predictive accuracy with that of the GRACE risk score. METHODS: In a single-center ACS registry of patients undergoing coronary angioplasty, we used the area under the receiver operating characteristic curve (AUC), a graphical representation of observed vs. expected mortality, and net reclassification improvement (NRI)/integrated discrimination improvement (IDI) analysis to compare the scores. RESULTS: A total of 2148 consecutive patients were included, mean age 63 years (SD 13), 74% male and 71% with ST-segment elevation ACS. In-hospital mortality was 4.5%. The GRACE score showed the best AUC (0.94, 95% CI 0.91-0.96) compared with NCDR (0.87, 95% CI 0.83-0.91, p=0.0003) and MCRS (0.85, 95% CI 0.81-0.90, p=0.0003). In model calibration analysis, GRACE showed the best predictive power. With GRACE, patients were more often correctly classified than with MCRS (NRI 78.7, 95% CI 59.6-97.7; IDI 0.136, 95% CI 0.073-0.199) or NCDR (NRI 79.2, 95% CI 60.2-98.2; IDI 0.148, 95% CI 0.087-0.209). CONCLUSION: The NCDR and Mayo Clinic risk scores are useful for risk stratification of in-hospital mortality in a European population of patients with ACS undergoing coronary angioplasty. However, the GRACE score is still to be preferred.