912 resultados para Pensée technique
Resumo:
Arteriovenous malformations (AVMs) may be cured by injecting liquid embolic agents such as Onyx. Reflux, however, can sometimes be difficult to control and may jeopardize a complete embolization. The pressure cooker technique (PCT) was designed to create an anti-reflux plug by trapping the detachable part of an Onyx-compatible microcatheter with coils and glue in order to obtain wedge-flow conditions, thereby enabling a better understanding of macrofistulous AVMs and a more comprehensive, forceful and controlled Onyx embolization. The PCT might enlarge the range of AVMs amenable to endovascular cure. Three illustrative cases are presented.
Resumo:
Au cours des deux dernières décennies, la technique d'imagerie arthro-scanner a bénéficié de nombreux progrès technologiques et représente aujourd'hui une excellente alternative à l'imagerie par résonance magnétique (IRM) et / ou arthro-IRM dans l'évaluation des pathologies de la hanche. Cependant, elle reste limitée par l'exposition aux rayonnements ionisants importante. Les techniques de reconstruction itérative (IR) ont récemment été mis en oeuvre avec succès en imagerie ; la littérature montre que l'utilisation ces dernières contribue à réduire la dose d'environ 40 à 55%, comparativement aux protocoles courants utilisant la rétroprojection filtrée (FBP), en scanner de rachis. A notre connaissance, l'utilisation de techniques IR en arthro-scanner de hanche n'a pas été évaluée jusqu'à présent. Le but de notre étude était d'évaluer l'impact de la technique ASIR (GE Healthcare) sur la qualité de l'image objective et subjective en arthro-scanner de hanche, et d'évaluer son potentiel en terme de réduction de dose. Pour cela, trente sept patients examinés par arthro-scanner de hanche ont été randomisés en trois groupes : dose standard (CTDIvol = 38,4 mGy) et deux groupes de dose réduite (CTDIvol = 24,6 ou 15,4 mGy). Les images ont été reconstruites en rétroprojection filtrée (FBP) puis en appliquant différents pourcentages croissants d'ASIR (30, 50, 70 et 90%). Le bruit et le rapport contraste sur bruit (CNR) ont été mesurés. Deux radiologues spécialisés en imagerie musculo-squelettique ont évalué de manière indépendante la qualité de l'image au niveau de plusieurs structures anatomiques en utilisant une échelle de quatre grades. Ils ont également évalué les lésions labrales et du cartilage articulaire. Les résultats révèlent que le bruit augmente (p = 0,0009) et le CNR diminue (p = 0,001) de manière significative lorsque la dose diminue. A l'inverse, le bruit diminue (p = 0,0001) et le contraste sur bruit augmente (p < 0,003) de manière significative lorsque le pourcentage d'ASIR augmente ; on trouve également une augmentation significative des scores de la qualité de l'image pour le labrum, le cartilage, l'os sous-chondral, la qualité de l'image globale (au delà de ASIR 50%), ainsi que le bruit (p < 0,04), et une réduction significative pour l'os trabuculaire et les muscles (p < 0,03). Indépendamment du niveau de dose, il n'y a pas de différence significative pour la détection et la caractérisation des lésions labrales (n=24, p = 1) et des lésions cartilagineuses (n=40, p > 0,89) en fonction du pourcentage d'ASIR. Notre travail a permis de montrer que l'utilisation de plus de 50% d'ASIR permet de reduire de manière significative la dose d'irradiation reçue par le patient lors d'un arthro-scanner de hanche tout en maintenant une qualité d'image diagnostique comparable par rapport à un protocole de dose standard utilisant la rétroprojection filtrée.
Resumo:
There is controversy over the use of the Ross procedure with regard to the sub-coronary and root replacement technique and its long-term durability. A systematic review of the literature may provide insight into the outcomes of these two surgical subvariants. A systematic review of reports between 1967 and February 2013 on sub-coronary and root replacement Ross procedures was undertaken. Twenty-four articles were included and divided into (i) sub-coronary technique and (ii) root replacement technique. The 10-year survival rate for a mixed-patient population in the sub-coronary procedure was 87.3% with a 95% confidence interval (CI) of 79.7-93.4 and 89.1% (95% CI, 85.3-92.1) in the root replacement technique category. For adults, it was 94 vs 95.3% (CI, 88.9-98.1) and in the paediatric series it was 90 vs 92.7% (CI, 86.9-96.0), respectively. Freedom from reoperation at 10 years was, in the mixed population, 83.3% (95% CI, 69.9-93.4) and 93.3% (95% CI, 89.4-95.9) for sub-coronary versus root replacement technique, respectively. In adults, it was 98 vs 91.2% (95% CI, 82.4-295.8), and in the paediatric series 93.3 vs 92.0% (95% CI, 86.1-96.5) for sub-coronary versus root replacement technique, respectively. The Ross procedure arguably has satisfactory results over 5 and 10 years for both adults and children. The results do not support the advantages of the sub-coronary technique over the root replacement technique. Root replacement was of benefit to patients undergoing reoperations on neoaorta and for long-term survival in mixed series.
Resumo:
An 88 years old woman was admitted for muscular pain and weakness. She was under a treatment of simvastatin and was recently prescribed clarithromycin for a lung infection. The diagnosis of statin induced rhabdomyolysis by drug interaction was made. The evolution is good with eviction of the statin and aggressive hydratation. This case shows how important it is to know the risks factors and drug interactions predisposing to statin-induced myopathy.
Resumo:
In the present work, microstructure improvement using FSP (Friction Stir Processing) is studied. In the first part of the work, the microstructure improvement of as-cast A356 is demonstrated. Some tensile tests were applied to check the increase in ductility. However, the expected results couldn’t be achieved. In the second part, the microstructure improvement of a fusion weld in 1050 aluminium alloy is presented. Hardness tests were carried out to prove the mechanical propertyimprovements. In the third and last part, the microstructure improvement of 1050 aluminium alloy is achieved. A discussion of the mechanical property improvements induced by FSP is made. The influence of tool traverse speed on microstructure and mechanical properties is also discussed. Hardness tests and recrystallization theory enabled us to find out such influence
Resumo:
OBJECTIVE.: Injection of opioids to the superior cervical ganglion (SCG) has been reported to provide pain relief in patients suffering from different kinds of neuropathic facial pain conditions, such as trigeminal neuralgia, postherpetic neuralgia, and atypical facial pain. The classic approach to the SCG is a transoral technique using a so-called "stopper" to prevent accidental carotid artery puncture. The main disadvantage of this technique is that the needle tip is positioned distant from the actual target, possibly impeding successful block of the SCG. A further limitation is that injection of local anesthetics due to potential carotid artery puncture is contraindicated. We hypothesized that the SCG can be identified and blocked using ultrasound imaging, potentially increasing precision of this technique. INTERVENTIONS.: In this pilot study, 20 US-guided simulated blocks of the SCG were performed in 10 human cadavers in order to determine the accuracy of this novel block technique. After injection of 0.1 mL of dye, the cadavers were dissected to evaluate the needle position and coloring of the SCG. RESULTS.: Nineteen of the 20 needle tips were located in or next to the SCG. This corresponded to a simulated block success rate of 95% (95% confidence interval 85-100%). In 17 cases, the SCG was completely colored, and in two cases, the caudal half of the SCG was colored with dye. CONCLUSIONS.: The anatomical dissections confirmed that our ultrasound-guided approach to the SCG is accurate. Ultrasound could become an attractive alternative to the "blind" transoral technique of SCG blocks.
Resumo:
Background : Port-related bloodstream infection (PRBSI) is a common complication associated with long-term use of ports systems. Systemic antimicrobial therapy (ST) and removal of the device is the standard management of PRBSI. However, a conservative management combining ST with antibiotic lock therapy (ALT) without port removal has been suggested as an alternative management option for infections due to gram-positive skin colonizers with low virulence.¦Objectives : i) to assess the frequency of management of PRBSI in onco-hematological patients by combining the ALT with ST, without catheter removal and ii) to analyze the efficacy of such an approach.¦Methods : Retrospective observational study over a 6-year period between 2005 and 2010, including patients who where diagnosed with PRBSI and who were treated with ST and ALT. PRBSI diagnosis consisted in clinical signs of bacteremia with blood cultures positive for gram-positive skin colonizers. The primary endpoint was failure to cure the PRBSI.¦Results : 61 port infections were analysed, of which 23 PRBSI met the inclusion criteria. All the patients were suffering from haematological conditions and 75% were neutropenic at the time of PRBSI diagnosis. S. epidermidis was responsible for 91% of PRBSI (21/23). The median duration of ST was 14 days (range 7-35) and the median duration of ALT was 15 days (range 8-41). Failure to cure the PRBSI requiring port removal was observed in 4 patients, but was not associated with severe infectious complications. Kaplan-Meier analysis showed a success rate in port salvage at day 180 (6 months) of 78% (95%CI 59-97%).¦Conclusion : The success rate observed in the present study suggests that combining ST and ALT is an effective option to conservatively treat PRBSI caused by pathogens of low virulence such as S. epidermidis.
Adenovirus-mediated gene transfer into selected liver segments using a vascular exclusion technique.
Resumo:
Adenovirus-mediated gene therapy is hampered by severe virus-related toxicity, especially to the liver. The aim of the present study was to test the ability of a vascular exclusion technique to achieve transgene expression within selected liver segments, thus minimizing both viral and transgene product toxicity to the liver. An E1-E3-deleted replication-deficient adenovirus expressing a green fluorescent protein (GFP) reporter gene was injected into the portal vein of BDIX rats, with simultaneous clamping of the portal vein tributaries to liver segments II, III, IV, V, and VIII. GFP expression and inflammatory infiltrate were measured in the different segments of the liver and compared with those of the livers of animals receiving the viral vector in the portal vein without clamping. The GFP expression was significantly higher in the selectively perfused segments of the liver as compared with the non-perfused segments (p < 0.0001) and with the livers of animals that received the vector in the portal vein without clamping (p < 0.0001). Accordingly, the inflammatory infiltrate was more intense in the selectively perfused liver segments as compared with all other groups (p < 0.0001). Fluorescence was absent in lungs and kidneys and minimal in spleen. The clinical usefulness of adenovirus-mediated gene transfer to the liver largely depends on the reduction of its liver toxicity. Clamping of selected portal vein branches during injection allows for delivery of genes of interest to targeted liver segments. Transgene expression confined to selected liver segments may be useful in the treatment of focal liver diseases, including metastases.
Resumo:
Réalisée dans le cadre du projet de recherche initié à la section d'histoire et esthétique du cinéma de l'Université de Lausanne autour du concept « d'Épistémè 1900 », cette thèse cherche à mettre en rapport dialogique deux « ensembles » formés par l'histoire du cinéma et l'histoire des sciences du psychisme dans une période circonscrite entre 1880 et 1910. Il s'agit de repenser les liens entre cinéma et sciences du psychisme, chacun de ces ensembles discursifs étant traités au même niveau en tant qu'objets historiques de savoir qui ont des choses à nous apprendre sur le cinéma en tant que phénomène culturel, anthropologique et social. Au passage du siècle, cinéma et sciences du psychisme se rencontrent au coeur d'une nouvelle problématisation du sujet définie par des savoirs scientifiques et parascientifiques alors confrontés aux phénomènes intriguants de l'hystérie et de l'hypnose. L'hystérie et l'hypnose provoquent des états nerveux lesquels constituent un terrain propice au développement de sujets divisés, hallucinés et intrancés, conduisant les médecins et psychologues à remettre en question l'idée d'un moi homogène et contrôlé. L'expansion d'une culture névrotique fabriquant à la chaîne des corps automatiques voués à leur inconscient cérébral permet de rapprocher le cinéma et les théories du psychisme sur une base qui a été rarement explorée jusqu'ici, en particulier relativement à la construction (théorique) du spectateur de cinéma. Si le dispositif cinématographique en tant que technique, représentation et modèle de pensée reprend à son compte l'imaginaire médical de cette époque, il contribue également en retour à façonner une conception de la subjectivité étroitement tributaire des technologies contemporaines et des fantasmes qu'elles génèrent. Aux côtés des personnages hystériques filmés par les premiers opérateurs, les spectateurs tels que décrits dans les textes-sources participent, d'une part à attester de la persistance du modèle neuro-pathologique dans la culture visuelle du début du XXe siècle, et d'autre part à transformer la vision savante du sujet dans ses rapports perceptifs et affectifs avec le monde environnant. C'est donc dans une logique d'interactions réciproques qu'il faut envisager les rapports entre le cinéma (conçu ici essentiellement comme comme un dispositif réunissant un appareillage, une image et un spectateur) et les connaissances relatives à l'intériorité psychique qui s'élaborent dans le domaine des sciences médico-psychologiques. Pour étudier ces rapports, j'ai choisi la figure du spectateur puisque les théories du psychisme s'intéressent prioritairement à l'humain et à sa subjectivité. À partir de cette figure-clé, j'ai tenté de montrer comment le spectacle cinématographique et les sciences du psychisme participent à des réflexions sur l'avènement d'une nouvelle forme de subjectivité consonante avec la modernité, une modernité qui bouleverse la manière d'envisager le fonctionnement de l'appareil psychique, donc les rapports de l'individu à soi-même et à ses images, mais aussi aux autres et au monde en général. Les croisements entre le sujet du cinéma et le sujet des sciences du psychisme s'effectuent autour de quatre paradigmes selon moi définitoires de la subjectivité autour de 1900 et structurant l'ensemble de cette recherche : la fatigue, le choc, l'hallucination et l'hypnose. En parcourant les sources, on s'aperçoit en effet qu'elles envisagent le corps humain tantôt comme une machine (un corps thermodynamique et électrophysiologique), tantôt comme hystérique ou neurasthénique (un corps traumatique et dysfonctionnel), tantôt comme rêveur (un corps producteur d'images et de sons perçus sur un mode hallucinatoire), tantôt comme hypermnésique (un corps de « clichés-souvenirs » emmagasinés à l'infini), tantôt comme hypnotisé (un corps suggestionné et contagieux). Tous ces corps, au final, ne forment qu'un seul corps générique, c'est-à-dire construisent et qualifient le corps nerveux des sciences du psychisme qui se manifeste sous différentes facettes en fonction des pathologies et des situations. À la fois unique et multiple, ce corps nerveux subsume le corpsmachine, le corps traumatisé, le corps halluciné et le corps hypnotisé qui font l'objet d'analyse détaillées dans les différentes parties de la thèse. Ces quatre grands « corps » retenus comme autant de déclinaisons possibles du corps nerveux sont directement mis en rapport avec quatre concepts : la fatigue, le choc, l'hallucination et l'hypnose - ce choix s'imposant face au constat de leur récurrence suite au dépouillement de nombreuses sources. J'ai tenté, au cours de ce travail, de défendre plusieurs hypothèses (ou séries d'hypothèses) relatives à l'avènement du spectateur cinématographique autour de 1900. Corrélées les unes aux autres, elles gagnent à être comprises ensemble. 1) Les sciences du psychisme et les discours sur les spectacles et dispositifs audiovisuels contribuent, dans leurs échanges, à la construction du sujet moderne, un sujet né de la révolution industrielle et s'épanouissant grâce à la culture de masse. La culture de masse met en scène des corps nerveux (automatiques, traumatisés, hallucinés et hypnotisés) dont la démultiplication sous différentes formes et en différents lieux fait émerger un nouveau modèle de subjectivité. Si le cinéma constitue un laboratoire expérimental du corps nerveux, il participe également à la transformation du corps nerveux en sujet nerveux, c'est-à-dire en un sujet moderne jouissant d'un nervosisme mué en modèle culturel. 2) Le cinématographe devient autour de 1900 un dispositif modélisateur pour les sciences du psychisme qui conceptualisent le fonctionnement de l'appareil psychique sous les espèces d'une machine projetant des sons et des images. En tant qu'opérateur de pensée, le cinéma offre une pluralité de modèles épistémologiques possibles, suivant que l'on s'intéresse à son fonctionnement général, ses détails techniques, ses effets sur les spectateurs, sa dimension spectaculaire et populaire. Par conséquent, le cinéma peut étayer une variété d'objets dans le champ des sciences médicales : le corps, l'esprit, la pensée, l'imagination, le rêve, l'hallucination, l'hypnose, la psychose ; mais aussi le corps individuel ou social, qu'ils soient sains ou malades. C'est sur cette base, j'en viens à penser que le spectateur de cinéma sert de modèle au sujet nerveux des sciences médicales. 3) Le rôle modélisateur du cinéma provoque en effet des modifications dans la manière de théoriser le corps nerveux puisqu'il fait transiter le corps nerveux de la psychopathologie vers le sujet nerveux de la culture spectaculaire moderne. Le spectateur du cinéma des premiers temps apparaît comme le prototype du sujet sidéré par le spectacle du monde moderne, prenant plaisir à être surstimulé et se prêtant volontiers au jeu de l'illusion de réalité. Actualisant un modèle de spectatorialité ambivalent, balançant entre hystérie et hypnose, le spectateur cinématographique intègre les codes de la maladie nerveuse pour leur donner une nouvelle dimension (esthétique, artistique) sur la scène sociale. 4) Les trois premières séries d'hypothèses ne peuvent être validées que si l'on examine comment les discours sur le cinéma pré-institutionnel se sont appropriés la culture du corps nerveux, de sorte à façonner un modèle de spectatorialité étayé sur les valeurs féminines d'impressionnabilité, d'excitabilité et de sentimentalité (des valeurs culturellement construites). Partant, j'ai voulu montrer que si durant la première phase de son histoire, le spectacle cinématographique fait l'objet d'une hystéricisation de la part des discours qui l'annexent à la sphère féminine de la culture de masse, dans sa phase d'institutionnalisation, on assiste à un processus de masculinisation du modèle spectatoriel (mais également, des lieux d'exibition, du mode de production, du mode de représentation, etc.).
Resumo:
The interfacial micromotion is closely associated to the long-term success of cementless hip prostheses. Various techniques have been proposed to measure them, but only a few number of points over the stem surface can be measured simultaneously. In this paper, we propose a new technique based on micro-Computer Tomography (μCT) to measure locally the relative interfacial micromotions between the metallic stem and the surrounding femoral bone. Tantalum beads were stuck at the stem surface and spread at the endosteal surface. Relative micromotions between the stem and the endosteal bone surfaces were measured at different loading amplitudes. The estimated error was 10μm and the maximal micromotion was 60μm, in the loading direction, at 1400N. This pilot study provided a local measurement of the micromotions in the 3 direction and at 8 locations on the stem surface simultaneously. This technique could be easily extended to higher loads and a much larger number of points, covering the entire stem surface and providing a quasi-continuous distribution of the 3D interfacial micromotions around the stem. The new measurement method would be very useful to compare the induced micromotions of different stem designs and to optimize the primary stability of cementless total hip arthroplasty.