816 resultados para Parallel computers - Design and construction


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the recent finding by Muhlhaus et al [1] that bifurcation of crack growth patterns exists for arrays of two-dimensional cracks. This bifurcation is a result of the nonlinear effect due to crack interaction, which is, in the present analysis, approximated by the dipole asymptotic or pseudo-traction method. The nonlinear parameter for the problem is the crack length/ spacing ratio lambda = a/h. For parallel and edge crack arrays under far field tension, uniform crack growth patterns (all cracks having same size) yield to nonuniform crack growth patterns (i.e. bifurcation) if lambda is larger than a critical value lambda(cr) (note that such bifurcation is not found for collinear crack arrays). For parallel and edge crack arrays respectively, the value of lambda(cr) decreases monotonically from (2/9)(1/2) and (2/15.096)(1/2) for arrays of 2 cracks, to (2/3)(1/2)/pi and (2/5.032)(1/2)/pi for infinite arrays of cracks. The critical parameter lambda(cr) is calculated numerically for arrays of up to 100 cracks, whilst discrete Fourier transform is used to obtain the exact solution of lambda(cr) for infinite crack arrays. For geomaterials, bifurcation can also occurs when array of sliding cracks are under compression.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Inhibitors of proteolytic enzymes (proteases) are emerging as prospective treatments for diseases such as AIDS and viral infections, cancers, inflammatory disorders, and Alzheimer's disease. Generic approaches to the design of protease inhibitors are limited by the unpredictability of interactions between, and structural changes to, inhibitor and protease during binding. A computer analysis of superimposed crystal structures for 266 small molecule inhibitors bound to 48 proteases (16 aspartic, 17 serine, 8 cysteine, and 7 metallo) provides the first conclusive proof that inhibitors, including substrate analogues, commonly bind in an extended beta-strand conformation at the active sites of all these proteases. Representative superimposed structures are shown for (a) multiple inhibitors bound to a protease of each class, (b) single inhibitors each bound to multiple proteases, and (c) conformationally constrained inhibitors bound to proteases. Thus inhibitor/substrate conformation, rather than sequence/composition alone, influences protease recognition, and this has profound implications for inhibitor design. This conclusion is supported by NMR, CD, and binding studies for HIV-1 protease inhibitors/ substrates which, when preorganized in an extended conformation, have significantly higher protease affinity. Recognition is dependent upon conformational equilibria since helical and turn peptide conformations are not processed by proteases. Conformational selection explains the resistance of folded/structured regions of proteins to proteolytic degradation, the susceptibility of denatured proteins to processing, and the higher affinity of conformationally constrained 'extended' inhibitors/substrates for proteases. Other approaches to extended inhibitor conformations should similarly lead to high-affinity binding to a protease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many species of stomatopod crustaceans have multiple spectral classes of photoreceptors in their retinas. Behavioral evidence also indicates that stomatopods are capable of discriminating objects by their spectral differences alone, Most animals use only two to four different types of photoreceptors in their color vision systems, typically with broad sensitivity functions, but the stomatopods apparently include eight or more narrowband photoreceptor classes for color recognition. It is also known that stomatopods use several colored body regions in social interactions. To examine why stomatopods may be so 'concerned' with color, we measured the absorption spectra of visual pigments and intrarhabdomal filters, and the reflectance spectra from different parts of the bodies of several individuals of the gonodactyloid stomatopod species, Gonodactylus smithii. We then applied a model of multiple dichromatic channels for color encoding to examine whether the finely tuned color vision was specifically co-evolved with their complex color signals. Although the eye design of stomatopods seems suitable for detecting color signals of their own, the detection of color signals from other animals, such as reef fishes, can be enhanced as well. Color vision in G. smithii is therefore not exclusively adapted to detect its own color signals, but the spectral tuning of some photoreceptors (e.g. midband Rows 2 and 3) enhances the contrast of certain color signals to a large enough degree to make co-evolution between color vision and these rather specific color signals likely. Copyright (C) 2000 S. Karger AG, Basel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background The protease-activated receptor 1 (PAR-1), the main platelet receptor for thrombin, represents a novel target for treatment of arterial thrombosis, and SCH 530348 is an orally active, selective, competitive PAR-1 antagonist. We designed TRA.CER to evaluate the efficacy and safety of SCH 530348 compared with placebo in addition to standard of care in patients with non-ST-segment elevation (NSTE) acute coronary syndromes (ACS) and high-risk features. Trial design TRA.CER is a prospective, randomized, double-blind, multicenter, phase III trial with an original estimated sample size of 10,000 subjects. Our primary objective is to demonstrate that SCH 530348 in addition to standard of care will reduce the incidence of the composite of cardiovascular death, myocardial infarction (MI), stroke, recurrent ischemia with rehospitalization, and urgent coronary revascularization compared with standard of care alone. Our key secondary objective is to determine whether SCH 530348 will reduce the composite of cardiovascular death, MI, or stroke compared with standard of care alone. Secondary objectives related to safety are the composite of moderate and severe GUSTO bleeding and clinically significant TIMI bleeding. The trial will continue until a predetermined minimum number of centrally adjudicated primary and key secondary end point events have occurred and all subjects have participated in the study for at least I year. The TRA.CER trial is part of the large phase III SCH 530348 development program that includes a concomitant evaluation in secondary prevention. Conclusion TRA.CER will define efficacy and safety of the novel platelet PAR-1 inhibitor SCH 530348 in the treatment of high-risk patients with NSTE ACS in the setting of current treatment strategies. (Am Heart J 2009; 158:327-34.)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. The formation and measurement of self-concept were the foci of this research. Aims. The study aimed to investigate the influence of achievement on academic self-concept and to compare the Perception of Ability Scale for Students (PASS, Boersma & Chapman, 1992) with the Self-Description Questionnaire-1 (SDQ-1, Marsh, 1988). Sample. The participants were 479 grade 5 (mean age 126.6 months) coeducational Australian students, located in 18 schools. Method. An intra-class research design was used to investigate the influence of frame-of-reference on self-concept development. Results. As students' academic scores rose above their class mean their self-concepts increased and as students' academic scores fell below their class mean their self-concepts decreased. Students' difference from class mean predicted their self-concept scores. This finding was consistently shown across the reading, spelling, and mathematics domains using test and teaching rating data. A comparison between the PASS and the SDQ-1 demonstrated concurrent validity across self-concept domains. Conclusion. The findings support the notions that the social environment is a significant agent that influences self-concept, and that teacher ratings and standardised tests of achievement and the PASS and the SDQ-1 are valid measures for self-concept research.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To describe and analyse the study design and manuscript deficiencies in original research articles submitted to Emergency Medicine. Methods: This was a retrospective, analytical study. Articles were enrolled if the reports of the Section Editor and two reviewers were available. Data were extracted from these reports only. Outcome measures were the mean number and nature of the deficiencies and the mean reviewers’ assessment score. Results: Fifty-seven articles were evaluated (28 accepted for publication, 19 rejected, 10 pending revision). The mean (± SD) number of deficiencies was 18.1 ± 6.9, 16.4 ± 6.5 and 18.4 ± 6.7 for all articles, articles accepted for publication and articles rejected, respectively (P = 0.31 between accepted and rejected articles). The mean assessment scores (0–10) were 5.5 ± 1.5, 5.9 ± 1.5 and 4.7 ± 1.4 for all articles, articles accepted for publication and articles rejected, respectively. Accepted articles had a significantly higher assessment score than rejected articles (P = 0.006). For each group, there was a negative correlation between the number of deficiencies and the mean assessment score (P > 0.05). Significantly more rejected articles ‘… did not further our knowledge’ (P = 0.0014) and ‘… did not describe background information adequately’ (P = 0.049). Many rejected articles had ‘… findings that were not clinically or socially significant’ (P = 0.07). Common deficiencies among all articles included ambiguity of the methods (77%) and results (68%), conclusions not warranted by the data (72%), poor referencing (56%), inadequate study design description (51%), unclear tables (49%), an overly long discussion (49%), limitations of the study not described (51%), inadequate definition of terms (49%) and subject selection bias (40%). Conclusions: Researchers should undertake studies that are likely to further our knowledge and be clinically or socially significant. Deficiencies in manuscript preparation are more frequent than mistakes in study design and execution. Specific training or assistance in manuscript preparation is indicated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The complex design and development of a planar multilayer phased array antenna in microstrip technology can be simplified using two commercially available design tools 1) Ansoft Ensemble and 2) HP-EEsof Touchstone. In the approach presented here, Touchstone is used to design RF switches and phase shifters whose scattering parameters are incorporated in Ensemble simulations using its black box tool. Using this approach, Ensemble is able to fully analyze the performance of radiating and beamforming layers of a phased array prior to its manufacturing. This strategy is demonstrated in a design example of a 12-element linearly-polarized circular phased array operating at L band. A comparison between theoretical and experimental results of the array is demonstrated.