935 resultados para Ossos pelvians -- Fractures
Resumo:
This in vitro study evaluated the influence of the type of miniplate and the number of screws installed in the proximal and distal segments on the stability and resistance of Champy's osteosynthesis in mandibular angle fractures. Sixty polyurethane hemimandibles with bone-like consistency were randomly assigned to four groups (n = 15) and sectioned in the mandibular angle region to simulate fracture. The bone segments were fixed by different osteosynthesis methods using 2.0 mm miniplates and 2.0 mm x 6 mm rnonocortical screws. In groups 1 and 2, two conventional (G1) or locking (G2) screws were installed in each bone segment using a conventional (G1) or a locking (02) straight miniplate; in groups 3 and 4, three conventional (03) or locking (04) screws were installed in the proximal segment and four conventional (G3) or locking (04) screws were installed in the distal segment using a conventional (G3) or a locking (G4) seven-hole straight miniplate. The hemimandibles were loaded in compressive strength until a 4 mm displacement occurred between the segments, vertically or horizontally. Locking plate/screw systems provided significantly greater resistance to displacement than conventional ones (p < .01). Locking miniplates offered more resistance than conventional miniplates. Long locking miniplates provided greater stability than short ones.
Resumo:
The aim of the present study was to evaluate the postoperative complications of bicoronal flaps used to treat facial fractures. One hundred and thirty two patients that received bicoronal flaps for the treatment of upper and middle third facial fractures were called for clinical and radiographic examination. Minimum follow-up was 1 year and all patients had charts with adequate information about their perioperative care pertinent to the study. Results showed as complications hypoesthesia (17%), partial unilateral frontal motor deficit (11%), infection (3%), hypertrophic scars (3%), varying degrees of alopecia (18%), seroma or hematoma in the immediate postoperative period (5%). The flap provided wide surgical access to the upper and middle facial thirds with very few serious complications, most frequently allowing good aesthetic results. (C) 2011 European Association for Cranio-Maxillo-Facial Surgery.
Resumo:
Purpose: the purpose of this study was to evaluate complications occurring after immediate reconstruction of severe frontal sinus fractures, including cases where the fracture was not limited to the anterior wall and also involved the posterior wall and/or sinus floor.Patients and Methods: the records of twenty-six patients presently undergoing follow-up for frontal sinus fracture reconstruction were reviewed. Information regarding demographics, fracture characteristics and causes, associated facial fractures, use of grafts or implants, type of fixation used, nasofrontal duct management, use of antibiotics, and complications were noted. Patients were asked to return for clinical and radiographic follow-up to access late complications.Results: the average age of patients with frontal fractures was 29.1 years and 92.3% were male. Mean follow-up was 3.6 years. The most common causes of fracture were motor vehicle accidents and physical aggression. All patients presented with comminuted and dislocated anterior wall fractures, 34.6% presented with posterior wall fractures, and 46% had sinus floor fractures. Complications occurred in 7 patients (26.92%) and included pneumoencephalus, frontal cutaneous fistula, frontal bone irregularity, and sinusitis.Conclusions: Frontal sinus reconstruction is a good procedure for immediate fracture treatment if there is not excessive comminution, dislocation, or instability of the posterior wall and if the frontonasal duct area is intact or can be repaired. Most complications result from incorrect indication for reconstruction. (C) 2004 American Association of Oral and Maxillofacial Surgeons.
Resumo:
A face lateral do corpo da mandíbula de ratos foi irradiada pelo laser CO2 com disparos contínuos de 10watts de potência. Após três meses, o sulco formado pela irradiação apresentou, em uma grande extensão, material fundido com diversas fraturas. Após sete meses, o periósteo neoformado recobriu amplas áreas da incisão, que apresentou ainda material carbonizado. Um ano após a incisão, o periósteo neoformado estava composto por fibras colágenas, que formaram feixes espessos, transversais à incisão, ou malhas regulares, que recobriram a incisão. Ainda nessa fase, resquícios de material carbonizado foram verificados, caracterizando um retardo na regeneração óssea
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The purpose of this study was to analyze crown fractures and crown-root fractures due to dentoalveolar trauma, treated in the Integrated Clinic comprehensive dental care at Aracatuba School of Dentistry (UNESP), from January 1992 to July 2002. The data were obtained from files of trauma cases. on the analysis period, 293 patients had crown fractures or crown-root fractures, in 605 teeth. Sixty-nine percent were males and 31% were females. Adolescents between 11 and 18 years old were the most prevalent group (41.6%) and the maxillary arch was the most commonly traumatized (83%). The most commonly affected tooth was the maxillary central incisor (58.3%). The most frequent causes were falls from bicycles (30.8%). It was concluded that the reality of the local service is similar to the published data.
Resumo:
When a crown fracture involving pulpal exposure is produced, the therapeutic treatment to be applied depends to a great extent on the general histopathological condition of the exposed pulp. Hence, the objective of this study was to evaluate histopathological and bacteriological changes occurring in dental tissue and periradicular tissue of crown-fractured teeth with pulpal exposure. Twenty-four anterior teeth (central and lateral incisors) from the maxillary teeth of four young, adult Mongrel dogs were used. At 48 and 72 h after performing the crown fractures, the animals were sacrificed and the results evaluated. Both observation periods revealed the existence of an area of superficial inflammation with the formation of hyperplastic tissue towards the external surface. Intense neutrophilic infiltrate was observed below it. Mean depth of inflammation was greater at 48 h (4633.33 mum) than at 72 h (3933.33 mum), perhaps coinciding with the bigger pulp chamber opening (x1332.14 mum at 48 h vs. x479.52 mum at 72 h). Upon approaching the cervical portion, the inflammation became less. Bacterial contamination was constant in all the cases evaluated, worsening the histopathological findings with exposure time. This study demonstrates that when a crown fracture with pulpal exposure is produced, the success in treating it depends partly on how quickly therapeutic treatment is administered.
Resumo:
A giant anteater (Myrmecophaga tridactyla) was found with closed comminuted fractures on the fight radius and ulna and left humerus he duration of which was unknown. The animal was unable to use either of he thoracic limbs. The fractures were stabilized with 3.5-mm titanium plates and a commercially available mixture of micro lyophilized bovine cortical osseous and bovine BMP (Gen-tech(R), Baumer, Brazil) was implanted into the fractures sites. Postoperative radiographic evaluations were performed every 30 days and after four months. Bone healing was observed in all of he fractures. The animal was able to be reintroduced into its natural habitat. From his case we conclude that despite he low metabolic fate of the giant anteater, which is an inherent characteristic of this species, he treatment of radius, ulna and humerus fractures by means of plates and screws, associated with BMP on the Myrmecophaga tridactyla, was a success.
Resumo:
The aim of this study was to gather data on trauma etiology and mandibular fracture localization in patients who presented at the General Hospital of Nova Iguacu, Rio de Janeiro, Brazil. From March 2007 to December 2008, 95 patients with mandibular fracture were registered in a medical form, at the Bucomax-illofacial Surgery Department of the General Hospital of Nova Iguacu, Rio de Janeiro, Brazil. Concerning mandibular fracture etiology, 21.05% were caused by motorcycle accidents, followed by interpersonal violence without use of weapons (punches, kicks, bumps with the head, blows with the elbow, etc) (16.84%) and interpersonal violence with firearm (14.73%). It was found that 52.63% of the patients had a single fracture line. The most affected fracture area was the parasymphysis (26.02%), followed by the condyle (22.60%) and mandibular angle (18.49%). Concerning the injury area, 24.21% were directed to the mandibular symphysis, 22.17% of the patients did not remember the injury area, and 18.94% had multiple injuries. When the injury was directed to the symphysis, the result was more condyle fractures (11.64%), and injuries at the mandibular angle resulted in fractures at the angle itself (8.90%). The most common fracture cause was traffic accidents, mainly motorcycle accidents, and the most affected areas were the parasymphysis and the condyle. The mandible isolated fractures occurred in half of the cases. Motorcycle accidents resulted in more fractures in the parasymphysis area, and when the symphysis area is affected by injuries, the result is a higher percentage in condyle fractures.
Resumo:
A Brazilian orthopaedic company designed a stainless steel plate called Synthesis Pengo System (S.P.S.), which has one fixed and one changeable extremity. According to the assembly of the changeable extremity, it is possible to obtain dynamization or neutralization of the fracture site. Since the S.P.S. plate was developed for use in human patients, the aim of this study was to evaluate this system in long-bone diaphyseal fractures in dogs. Eight dogs with closed diaphyseal fractures of the femur (n = 1), radius and ulna (n = 5), and tibia (n = 2) were used. Patients were aged seven months to three years and weighed 18 to 31.2 kg. The S.P.S. plate was assembled with one fixed extremity and one changeable extremity in dynamization mode. The trail bar was positioned for synthesis modules with holes for cortical screws. The modules were positioned close to one another in two fractures and for away from the fracture site in the others. The bone healing occurred by external callus. Since motion at the fracture site determines the amount of callus required, the secondary bone healing that was observed in all of the cases indicated less rigid fixation of this system. A potential benefit of this system was a lesser interface contact with the bone since it was only done by trail bar. The major disadvantage was the prominence of the implant. It was possible to conclude that the S.P.S. plate appears to be a suitable method for the treatment of diaphyseal fractures in dogs.
Resumo:
A case report of the treatment of permanent incisors with crown and root fractures is presented. A radiolucent lesion at the fracture lines was treated with calcium hydroxide in the coronal fragments for 18 months. Clinically, the teeth became firm and the radiographic results after 2 years showed healing of the lesion and hard tissue filling in the space at the fracture lines. © Munksgaard, 2001.
Resumo:
OBJECTIVE: The aim of this study was to evaluate the resistance to fracture of intact and restored human maxillary premolars. METHOD AND MATERIALS: Thirty noncarious human maxillary premolars, divided into three groups of 10, were submitted to mechanical tests to evaluate their resistance to fracture. Group 1 consisted of intact teeth. Teeth in group 2 received mesio-occlusodistal cavity preparations and were restored with direct resin composite restorations. Teeth in group 3 received mesio-occlusodistal cavity preparations and were restored with ceromer inlays placed with the indirect technique. After restoration, teeth were stored at 37 degrees C for 24 hours and then thermocycled for 500 cycles at temperatures of 5 degrees C and 55 degrees C. RESULTS: Statistical analysis revealed that group 3 (178.765 kgf) had a significantly greater maximum rupture load than did group 1 (120.040 kgf). There was no statistically significant difference between groups 1 and 2 or between groups 2 and 3. CONCLUSION: Class II cavity preparations restored with indirect ceromer inlays offered greater resistance to fracture than did intact teeth. The fracture resistance of teeth restored with resin composite was not significantly different from that of either the ceromer or intact teeth.
Resumo:
The purpose of this study was to compare by qualitative histology the efficacy of rigid internal fixation with titanium system and the Lacto Sorb® system in mandibular fractures in rabbits. Thirty male adult rabbits Oryctolagus cuniculus were used. Unilateral mandibular osteotomies were performed between the canine and first premolar. The animals were divided into two groups: for Group I - rigid internal fixation was performed with titanium system 1.5 mm (Synthes, Oberdorf, Switzerland), with two screws of 6 mm (bicortical) on each side of the osteotomy. For Group II-rigid internal fixation was performed with PLLA/PGA system 1.5 mm (Lacto Sorb®, WLorenz, Jacksonville, FL, USA). The histological analysis evaluated the presence of inflammatory reaction, degree of bone healing and degree of resorption of the Lacto Sorb® screws. The results of both fixation systems were similar, only with a small difference after 15 and 30 days. In Group I a faster bony healing was noted. But after 60 days, bony healing was similar in both groups. It is concluded that both PLLA/PGA and titanium plates and screws provide sufficient strength to permit mandibular bone healing. The resorption process of PLLA/PGA osteosynthesis material did not cause acute or chronic inflammatory reaction or foreign body reaction during the studied period. © 2004 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.