999 resultados para Optimal Code
Resumo:
Code of Practice on Fluoridation of Drinking Water 2007 Fluoridation of drinking water, the main aim of which is the prevention and control of dental caries (dental decay), commenced in Ireland in 1964 after the introduction of the Health (Fluoridation of Water Supplies) Act 1960. The Act provides that health authorities shall arrange for the fluoridation of public piped water supplies. The Act also provides that sanitary (local) authorities may act as the agents of health authorities in fluoridating public piped water supplies. Currently approximately 73% of the population receives fluoridated water from public water supplies. Click here to download PDF 195kb
Resumo:
(Résumé de l'ouvrage) Das Deuteronomium nimmt sowohl in der Literaturgeschichte der alttestamentlichen Geschichtsbücher Josua bis Könige eine Schlüsselstellung ein als auch für die Entstehung des Pentateuchs. Wie lassen sich diese beiden Funktionen vereinbaren? Mit der Verhältnisbestimmung haben sich namhafte Wissenschafter der Arbeitsgruppe »Biblical and Ancient Near Eastern Law« im Rahmen der Internationalen Treffen der Society of Biblical Literature in Berlin (2002) und Cambridge (2003) befasst. Der Band präsentiert die neuesten Forschungsergebnisse. Er enthält Vorträge von E. Otto, K. Schmid, H.-C. Schmitt, T. Römer, W.M. Schniedewind, G.N. Knoppers, R. Achenbach, M.M. Zahn und C. Nihan.
Resumo:
Introduction: Coronary magnetic resonance angiography (MRA) is a medical imaging technique that involves collecting data from consecutive heartbeats, always at the same time in the cardiac cycle, in order to minimize heart motion artifacts. This technique relies on the assumption that coronary arteries always follow the same trajectory from heartbeat to heartbeat. Until now, choosing the acquisition window in the cardiac cycle was based exclusively on the position of minimal coronary motion. The goal of this study was to test the hypothesis that there are time intervals during the cardiac cycle when coronary beat-to-beat repositioning is optimal. The repositioning uncertainty values in these time intervals were then compared with the intervals of low coronary motion in order to propose an optimal acquisition window for coronary MRA. Methods: Cine breath-hold x-ray angiograms with synchronous ECG were collected from 11 patients who underwent elective routine diagnostic coronarography. Twenty-three bifurcations of the left coronary artery were selected as markers to evaluate repositioning uncertainty and velocity during cardiac cycle. Each bifurcation was tracked by two observers, with the help of a user-assisted algorithm implemented in Matlab (The Mathworks, Natick, MA, USA) that compared the trajectories of the markers coming from consecutive heartbeats and computed the coronary repositioning uncertainty with steps of 50ms until 650ms after the R-wave. Repositioning uncertainty was defined as the diameter of the smallest circle encompassing the points to be compared at the same time after the R-wave. Student's t-tests with a false discovery rate (FDR, q=0.1) correction for multiple comparison were applied to see whether coronary repositioning and velocity vary statistically during cardiac cycle. Bland-Altman plots and linear regression were used to assess intra- and inter-observer agreement. Results: The analysis of left coronary artery beat-to-beat repositioning uncertainty shows a tendency to have better repositioning in mid systole (less than 0.84±0.58mm) and mid diastole (less than 0.89±0.6mm) than in the rest of the cardiac cycle (highest value at 50ms=1.35±0.64mm). According to Student's t-tests with FDR correction for multiple comparison (q=0.1), two intervals, in mid systole (150-200ms) and mid diastole (550-600ms), provide statistically better repositioning in comparison with the early systole and the early diastole. Coronary velocity analysis reveals that left coronary artery moves more slowly in end systole (14.35±11.35mm/s at 225ms) and mid diastole (11.78±11.62mm/s at 625ms) than in the rest of the cardiac cycle (highest value at 25ms: 55.96±22.34mm/s). This was confirmed by Student's t-tests with FDR correction for multiple comparison (q=0.1, FDR-corrected p-value=0.054): coronary velocity values at 225, 575 and 625ms are not much different between them but they are statistically inferior to all others. Bland-Altman plots and linear regression show that intra-observer agreement (y=0.97x+0.02 with R²=0.93 at 150ms) is better than inter-observer (y=0.8x+0.11 with R²=0.67 at 150ms). Discussion: The present study has demonstrated that there are two time intervals in the cardiac cycle, one in mid systole and one in mid diastole, where left coronary artery repositioning uncertainty reaches points of local minima. It has also been calculated that the velocity is the lowest in end systole and mid diastole. Since systole is less influenced by heart rate variability than diastole, it was finally proposed to test an acquisition window between 150 and 200ms after the R-wave.
Resumo:
In eusocial Hymenoptera, queens and workers are in conflict over optimal sex allocation. Sex ratio theory, while generating predictions on the extent of this conflict under a wide range of conditions, has largely neglected the fact that worker control of investment almost certainly requires the manipulation of brood sex ratio. This manipulation is likely to incur costs, for example, if workers eliminate male larvae or rear more females as sexuals rather than workers. In this article, we present a model of sex ratio evolution under worker control that incorporates costs of brood manipulation. We assume cost to be a continuous, increasing function of the magnitude of sex ratio manipulation. We demonstrate that costs counterselect sex ratio biasing, which leads to less female-biased population sex ratios than expected on the basis of relatedness asymmetry. Furthermore, differently shaped cost functions lead to different equilibria of manipulation at the colony level. While linear and accelerating cost functions generate monomorphic equilibria, decelerating costs lead to a process of evolutionary branching and hence split sex ratios.
Resumo:
Influenza surveillance networks must detect early the viruses that will cause the forthcoming annual epidemics and isolate the strains for further characterization. We obtained the highest sensitivity (95.4%) with a diagnostic tool that combined a shell-vial assay and reverse transcription-PCR on cell culture supernatants at 48 h, and indeed, recovered the strain
Resumo:
Most network operators have considered reducing Label Switched Routers (LSR) label spaces (i.e. the number of labels that can be used) as a means of simplifying management of underlaying Virtual Private Networks (VPNs) and, hence, reducing operational expenditure (OPEX). This letter discusses the problem of reducing the label spaces in Multiprotocol Label Switched (MPLS) networks using label merging - better known as MultiPoint-to-Point (MP2P) connections. Because of its origins in IP, MP2P connections have been considered to have tree- shapes with Label Switched Paths (LSP) as branches. Due to this fact, previous works by many authors affirm that the problem of minimizing the label space using MP2P in MPLS - the Merging Problem - cannot be solved optimally with a polynomial algorithm (NP-complete), since it involves a hard- decision problem. However, in this letter, the Merging Problem is analyzed, from the perspective of MPLS, and it is deduced that tree-shapes in MP2P connections are irrelevant. By overriding this tree-shape consideration, it is possible to perform label merging in polynomial time. Based on how MPLS signaling works, this letter proposes an algorithm to compute the minimum number of labels using label merging: the Full Label Merging algorithm. As conclusion, we reclassify the Merging Problem as Polynomial-solvable, instead of NP-complete. In addition, simulation experiments confirm that without the tree-branch selection problem, more labels can be reduced
Resumo:
Collection : Collection des lois civiles et criminelles des Etats modernes ; 1ère livraison