448 resultados para OECT PEDPT:PSS Biosensoristica elettrochimica
Resumo:
In order to investigate the effect on the aqueous solubility and release rate of sulfamerazine (SMR) as model drug, inclusion complexes with beta-cyclodextrin (beta CD), methyl-beta-cyclodextrin (M beta CD) and hydroxypropyl-beta-cyclodextrin (HP beta CD) and a binary system with meglumine (MEG) were developed. The formation of 1: 1 inclusion complexes of SMR with the CDs and a SMR: MEG binary system in solution and in solid state was revealed by phase solubility studies (PSS), nuclear magnetic resonance (NMR), Fourier-transform infrared spectroscopy (FT-IR), thermal analysis and X-Ray diffractometry (XRD) studies. The CDs solubilization of SMR could be improved by ionization of the drug molecule through pH adjustments. The higher apparent stability constants of SMR:CDs complexes were obtained in pH 2.00, demonstrating that CDs present more affinity for the unionized drug. The best approach for SMR solubility enhancement results from the combination of MEG and pH adjustment, with a 34-fold increment and a S-max of 54.8 mg/ml. The permeability of the drug was reduced due to the presence of beta CD, M beta CD, HP beta CD and MEG when used as solubilizers. The study then suggests interesting applications of CD or MEG complexes for modulating the release rate of SMR through semipermeable membranes.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The long-term efficacy and safety of intravenous abatacept in patients (pts) with juvenile idiopathic arthritis (JIA) have been reported previously from the Phase III AWAKEN trial ([1, 2]). Here, we report efficacy, safety and pt-reported outcomes from the open-label, long-term extension (LTE) of AWAKEN, with up to 7 years of follow-up. Pts entered the LTE if they were JIA ACR 30 non-responders (NR) at the end of the 4-month lead-in period (abatacept only), or if they received abatacept or placebo (pbo) in the 6-month double-blind (DB) period. The Child Health Questionnaire was used to evaluate health-related quality of life (HRQoL); physical (PhS) and psychosocial (PsS) summary and pain scores were analyzed. Pain was assessed by parent global assessment using a 100 mm visual analog scale. Efficacy and HRQoL evaluations are reported up to Day 1765 (~ Year 5.5). Safety is presented for the cumulative period (lead-in, DB and LTE), for all pts who received abatacept during the LTE. Of the 153 pts entering the LTE (58 from DB abatacept group, 59 from DB pbo group, 36 NR), 69 completed the trial (29 abatacept, 27 pbo, 13 NR). For pts treated in the LTE, mean (range) exposure to abatacept was 53.6 (5.6–85.6) months. During the LTE, incidence rates of AEs and serious AEs per 100 pt-years were 209.1 and 5.6. Thirty pts (19.6%) had serious AEs; most were unrelated and were musculoskeletal (8.5%) or infectious events (6.5%). No malignancy was reported. There was one death (accidental; unrelated). At Day 169, JIA ACR 50 and 70 response rates were 79.3% and 55.2% in the abatacept group, and 52.5% and 30.5% in the pbo group; 31.0% and 10.2% of pts in the abatacept and pbo groups, respectively, had inactive disease. By Day 1765, JIA ACR 50 and 70 response rates were 93.9% and 78.8% in the abatacept group, and 80.0% and 63.3% in the pbo group; 51.5% and 33.3% had inactive disease. In the NR group, 69.2% and 53.8% of pts achieved JIA ACR 50 and 70 responses at Day 1765, and 30.8% had inactive disease. In pts who entered the LTE, mean baseline PhS scores were below the range for healthy children (abatacept 30.2, pbo 31.0, NR 29.5). At Day 169, 38.3% of pts had reached a PhS score >50 ((1). By the end of the LTE, 43.5% of pts had reached a PhS score >50. At baseline, mean PsS scores for those who entered the LTE were slightly lower than the mean for healthy children (abatacept 43.5, pbo 44.2, NR 47.0). At Day 169, 54.9% of pts had a PsS score >50 (1). By Day 1765, 58.1% of pts had reached a PsS score >50. At baseline, the mean pain score was 42.9. By Day 169, 13.9% of pts were considered pain free (pain score = 0); this was maintained over the LTE (1).
Resumo:
Fabrication of optoelectronic devices requires the employment of at least one transparent electrode. Usually, commercially transparent electrodes have been made by deposition of indium tin oxide (ITO) films by RF-Sputtering technique. These commercial electrodes have sheet resistance of about 100 Ω/sq and optical transmittance of 77% at the wavelength of 550 nm. The poly(3,4-ethylenedioxythiophene):polystyrene-sulfonate (PEDOT:PSS) is an alternative material to fabricate transparent electrodes due to its high conductivity (about 600 S/cm) and solubility in water. Soluble conductive materials exhibits advantages for processing of electrode layers, however there is a disadvantage during devices fabrication once materials with the same solvent of the electrode material cannot be coated one over the other. Alternatively, organic/Silica hybrid materials prepared by sol-gel process allow producing bulks and films with high chemical durability. In order to obtain transparent electrodes with high chemical durability, we introduced a blended material comprising the high UV-VIS transparency of organic/Silica sol-gel material and a high conductivity polymer PEDOT:PSS. The organic/Silica sol was obtained using two different molar concentrations (1:1 and 4:1), of tetraethylorthosilicate (TEOS) and 3-glycidoxypropyltrimethoxysilane (GPTS). Amounts of PEDOT:PSS solutions were added to the sol material, resulting in different weight fractions of sol and polymer. G:T/P:P were deposit onto glass substrates by spray-coating. In order to perform electrical characterization of the blended material, gold electrodes were thermally evaporated onto the films. The electrical characterization was performed using a Keithley 2410 source/meter unity and the optical characterization, using a Cary50 UV-Vis spectrophotometer. The absorption coefficient and electric conductivity of the different compositions blends, as function of the PEDOT:PSS concentration, were...
Resumo:
Pós-graduação em Ciência e Tecnologia de Materiais - FC
Resumo:
This study investigates the structures of layers of amphiphilic diblock copolymers of poly(t-butyl styrene)-poly- (styrene sulfonate) (PtBS-PSS) adsorbed on both the bare mica surface (hydrophilic) and an octadecyltriethoxysilane (OTE)-modified mica surface (hydrophobic). When the surface is rendered hydrophobic, the nonsoluble block exhibits stronger interaction with the surface and higher adsorbed masses are achieved. Interaction forces between two such adsorbed layers on both substrates were measured using the surface forces apparatus. The effect of salt concentration (Cs) and molecular weight (N) on the height of the self-assembled layers (L0) was examined in each case. The resulting scaling relationship is in good agreement with predictions of the brush model, L0 ∞ N1.0 in the low-salt limit and L0N-1 ∞ (Cs/σ)-0.32 in the salted regime, when adsorption takes place onto the hydrophobized mica surface. For adsorption on the bare mica surface, L0N-0.7 ∞ Cs -0.17 agrees with the scaling prediction of the sparse tethering model. The results suggest that, on the hydrophilic bare mica surface, the adsorbed amount is not high enough to form a brush structure and only very little intermolecular stretching of the tethered chains occurs; in contrast, the presence of the hydrophobic OTE layer increases the tethering density such that the polyelectrolyte chains adopt a brush conformation.
Resumo:
The development of new electroluminescence polymers for specific colour tuning in Polymer Light Emitting Devices (PLEDs) is currently one of the most important fields for organic electronics. This work reports a synthesis of a new electroluminescent polymer and the concomitant test as PLED emissive layer. The polymer, synthesised from fluorene, is poly(9,9`-n-dihexil-2,7-fluorenodiilvinylene-alt-2,5thiophene) or PFT The luminescence shows large bands with maxima around 480 nm in absorption and 560 nm in emission. The device was made in a three layer structure, with PEDOT:PSS as hole transport layer, PFT as emissive layer and butyl-PBD as electron transport layer. The electroluminescence spectrum shows a strong band peaked at 540 nm. For an applied voltage of 12 Volt, the brightness at normal angle of viewing is near 10 cd/m(2) and the luminous efficiency is of 0.01 lm/W. A discussion about carrier transport and the electroluminescence properties is made.
Resumo:
Antiphospholipid antibodies (aPL) and antiphospholipid syndrome (APS) have been described in primary Sjogren's syndrome (pSS) with controversial findings regarding aPL prevalence and their association with thrombotic events. We evaluated 100 consecutive pSS patients (American-European criteria) and 89 age-gender-ethnicity-matched healthy controls for IgG/IgM anticardiolipin (aCL), IgG/IgM anti-beta2-glycoprotein-I (a beta 2GPI), and lupus anticoagulant (LA) (positivity according to APS Sydney's criteria). Clinical analysis followed standardized interview and physical examination assessing thrombotic and nonthrombotic APS manifestations and thrombosis risk factors. aPLs were detected in 16 % patients and 5.6 % controls (p = 0.035). LA was the most common aPL in patients (9 %), followed by a beta 2GPI (5 %) and aCL (4 %). Thrombotic events occurred in five patients [stroke in two, myocardial infarction in one and deep-vein thrombosis (DVT) in four], but in none of controls (p = 0.061). Mean age at time of stroke was 35 years. Three patients with thrombotic events (including the two with stroke) had APS (Sydney's criteria) and were positive exclusively for LA. Comparison of patients with (n = 16) and without (n = 84) aPL revealed similar mean age, female predominance, and ethnicity (p > =0.387). Frequencies of livedo reticularis (25 vs. 4.8 %, p = 0.021), stroke (12.5 vs. 0 %, p = 0.024), and DVT (18.8 vs. 1.2 %, p = 0.013) were significantly higher in APL + patients. Conversely, frequencies of hypertension, dyslipidemia, diabetes, obesity, smoking, sedentarism, and hormonal contraception were similar in patients with or without aPL (p a parts per thousand yenaEuro parts per thousand 0.253). Our study identified LA as an important marker for APS in pSS, particularly for stroke in young patients, warranting routine evaluation of these antibodies and rigorous intervention in modifiable risk factors.
Resumo:
We measured the mixing ratios of NO, NO2, O-3, and volatile organic carbon as well as the aerosol light-scattering coefficient on a boat platform cruising on rivers downwind of the city of Manaus (Amazonas State, Brazil) in July 2001 (Large-Scale Biosphere-Atmosphere Experiment in Amazonia-Cooperative LBA Airborne Regional Experiment-2001). The dispersion and impact of the Manaus plume was investigated by a combined analysis of ground-based (boat platform) and airborne trace gas and aerosol measurements as well as by meteorological measurements complemented by dispersion calculations (Hybrid Single-Particle Lagrangian Integrated Trajectory model). For the cases with the least anthropogenic influence (including a location in a so far unexplored region similar to 150 km west of Manaus on the Rio Manacapuru), the aerosol scattering coefficient, sigma(s), was below 11 Mm(-1), NOx mixing ratios remained below 0.6 ppb, daytime O-3 mixing ratios were mostly below 20 ppb and maximal isoprene mixing ratios were about 3 ppb in the afternoon. The photostationary state (PSS) was not established for these cases, as indicated by values of the Leighton ratio, Phi, well above unity. Due to the influence of river breeze systems and other thermally driven mesoscale circulations, a change of the synoptic wind direction from east-northeast to south-southeast in the afternoon often caused a substantial increase of ss and trace gas mixing ratios (about threefold for sigma(s), fivefold for NOx, and twofold for O-3), which was associated with the arrival of the Manaus pollution plume at the boat location. The ratio F reached unity within its uncertainty range at NOx mixing ratios of about 3 ppb, indicating "steady-state" conditions in cases when radiation variations, dry deposition, emissions, and reactions mostly involving peroxy radicals (XO2) played a minor role. The median midday/afternoon XO2 mixing ratios estimated using the PSS method range from 90 to 120 parts per trillion (ppt) for the remote cases (sigma(s) < 11 Mm(-1) and NOx < 0.6 ppb), while for the polluted cases our estimates are 15 to 60 ppt. These values are within the range of XO2 estimated by an atmospheric chemistry box model (Chemistry As A Box model Application-Module Efficiently Calculating the Chemistry of the Atmosphere (CAABA/MECCA)-3.0).
Resumo:
This work proposes a computational tool to assist power system engineers in the field tuning of power system stabilizers (PSSs) and Automatic Voltage Regulators (AVRs). The outcome of this tool is a range of gain values for theses controllers within which there is a theoretical guarantee of stability for the closed-loop system. This range is given as a set of limit values for the static gains of the controllers of interest, in such a way that the engineer responsible for the field tuning of PSSs and/or AVRs can be confident with respect to system stability when adjusting the corresponding static gains within this range. This feature of the proposed tool is highly desirable from a practical viewpoint, since the PSS and AVR commissioning stage always involve some readjustment of the controller gains to account for the differences between the nominal model and the actual behavior of the system. By capturing these differences as uncertainties in the model, this computational tool is able to guarantee stability for the whole uncertain model using an approach based on linear matrix inequalities. It is also important to remark that the tool proposed in this paper can also be applied to other types of parameters of either PSSs or Power Oscillation Dampers, as well as other types of controllers (such as speed governors, for example). To show its effectiveness, applications of the proposed tool to two benchmarks for small signal stability studies are presented at the end of this paper.
Resumo:
Ultra-thin (thicknesses of 50-90 nm) nanocomposite films of cobalt ferrite nanoparticles (np-CoFe2O4, 18 nm in diameter) and polyelectrolytes (doped polyaniline-PANI, poly-3,4-ethylenedioxy thiophene: polystyrene sulfonic acid-PEDOT:PSS, and sulfonated lignin-SL) are assembled layer-by-layer onto interdigitated microelectrodes aiming at to create novel nanostructured sensoactive materials for liquid media chemical sensors. The nanocomposites display a distinctive globular morphology with nanoparticles densely-packed while surrounded by polyelectrolytes. Due to the presence of np-CoFe2O4 the nanocomposites display low electrical conductivity according to impedance data. On the other hand, this apparent shortcoming turns such nanocomposites much more sensitive to the presence of ions in solution than films made exclusively of conducting polyelectrolytes. For example, the electrical resistance of np-CoFe2O4/PEDOT:PSS and PANI/SL/np-CoFe2O4/SL architectures has a 10-fold decrease when they are immersed in 20 mmol. L-1 NaCl solution. Impedance spectra fitted with the response of an equivalent circuit model suggest that the interface created between nanoparticles and polyelectrolytes plays a major role on the nanocomposites electrical/dielectrical behavior. Since charge transport is sensitive to nanoparticle-polyelectrolyte interfaces as well as to the physicochemical conditions of the environment, the np-CoFe2O4-based nanocomposites can be used as sensing elements in chemical sensors operated under ac regime and room temperature.