941 resultados para Mobile application testing


Relevância:

40.00% 40.00%

Publicador:

Resumo:

We develop a new autoregressive conditional process to capture both the changes and the persistency of the intraday seasonal (U-shape) pattern of volatility in essay 1. Unlike other procedures, this approach allows for the intraday volatility pattern to change over time without the filtering process injecting a spurious pattern of noise into the filtered series. We show that prior deterministic filtering procedures are special cases of the autoregressive conditional filtering process presented here. Lagrange multiplier tests prove that the stochastic seasonal variance component is statistically significant. Specification tests using the correlogram and cross-spectral analyses prove the reliability of the autoregressive conditional filtering process. In essay 2 we develop a new methodology to decompose return variance in order to examine the informativeness embedded in the return series. The variance is decomposed into the information arrival component and the noise factor component. This decomposition methodology differs from previous studies in that both the informational variance and the noise variance are time-varying. Furthermore, the covariance of the informational component and the noisy component is no longer restricted to be zero. The resultant measure of price informativeness is defined as the informational variance divided by the total variance of the returns. The noisy rational expectations model predicts that uninformed traders react to price changes more than informed traders, since uninformed traders cannot distinguish between price changes caused by information arrivals and price changes caused by noise. This hypothesis is tested in essay 3 using intraday data with the intraday seasonal volatility component removed, as based on the procedure in the first essay. The resultant seasonally adjusted variance series is decomposed into components caused by unexpected information arrivals and by noise in order to examine informativeness.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: The management of childhood obesity is challenging. Aims: Thesis, i) reviews the evidence for lifestyle treatment of obesity, ii) explores cardiometabolic burden in childhood obesity, iii) explores whether changes in body composition predicts change in insulin sensitivity (IS), iv) develops and evaluates a lifestyle obesity intervention; v) develops a mobile health application for obesity treatment and vi) tests the application in a clinical trial. Methods: In Study 1, systematic reviews and meta-analyses of the 12‐month effects of lifestyle and mHealth interventions were conducted. In Study 2, the prevalence of cardiometabolic burden was estimated in a consecutive series of 267 children. In Study 3, body composition was estimated with bioelectrical impedance analysis (BIA) and dual x-ray absorptiometry (DXA) and linear regression analyses were used to estimate the extent to which each methods predicted change in IS. Study 4 describes the development of the Temple Street W82GO Healthy Lifestyle intervention for clinical obesity in children and a controlled study of treatment effect in 276 children is reported. Study 5 describes the development and testing of the Reactivate Mobile Obesity Application. Study 6 outlines the development and preliminary report from a clinical effectiveness trial of Reactivate. Results: In Study 1, meta--‐analyses BMI SDS changed by -0.16 (-0.24,‐0.07, p<0.01) and -0.03 (-0.13, 0.06, p=0.48). In study 2, cardiometabolic comorbidities were common (e.g. hypertension in 49%) and prevalence increased as obesity level increased. In Study 3, BC changes significantly predicted changes in IS. In Study 4, BMI SDS was significantly reduced in W82GO compared to controls (p<0.001). In Study 5, the Reactivate application had good usability indices and preliminary 6‐month process report data from Study 6, revealed a promising effect for Reactivate. Conclusions: W82GO and Reactivate are promising forms of treatment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This dissertation studies the context-aware application with its proposed algorithms at client side. The required context-aware infrastructure is discussed in depth to illustrate that such an infrastructure collects the mobile user’s context information, registers service providers, derives mobile user’s current context, distributes user context among context-aware applications, and provides tailored services. The approach proposed tries to strike a balance between the context server and mobile devices. The context acquisition is centralized at the server to ensure the usability of context information among mobile devices, while context reasoning remains at the application level. Hence, a centralized context acquisition and distributed context reasoning are viewed as a better solution overall. The context-aware search application is designed and implemented at the server side. A new algorithm is proposed to take into consideration the user context profiles. By promoting feedback on the dynamics of the system, any prior user selection is now saved for further analysis such that it may contribute to help the results of a subsequent search. On the basis of these developments at the server side, various solutions are consequently provided at the client side. A proxy software-based component is set up for the purpose of data collection. This research endorses the belief that the proxy at the client side should contain the context reasoning component. Implementation of such a component provides credence to this belief in that the context applications are able to derive the user context profiles. Furthermore, a context cache scheme is implemented to manage the cache on the client device in order to minimize processing requirements and other resources (bandwidth, CPU cycle, power). Java and MySQL platforms are used to implement the proposed architecture and to test scenarios derived from user’s daily activities. To meet the practical demands required of a testing environment without the impositions of a heavy cost for establishing such a comprehensive infrastructure, a software simulation using a free Yahoo search API is provided as a means to evaluate the effectiveness of the design approach in a most realistic way. The integration of Yahoo search engine into the context-aware architecture design proves how context aware application can meet user demands for tailored services and products in and around the user’s environment. The test results show that the overall design is highly effective,providing new features and enriching the mobile user’s experience through a broad scope of potential applications.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-08

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Despite their increasing popularity, little is known about how users perceive mobile devices such as smartphones and tablet PCs in medical contexts. Available studies are often restricted to evaluating the success of specific interventions and do not adequately cover the users' basic attitudes, for example, their expectations or concerns toward using mobile devices in medical settings. OBJECTIVE: The objective of the study was to obtain a comprehensive picture, both from the perspective of the patients, as well as the doctors, regarding the use and acceptance of mobile devices within medical contexts in general well as the perceived challenges when introducing the technology. METHODS: Doctors working at Hannover Medical School (206/1151, response 17.90%), as well as patients being admitted to this facility (213/279, utilization 76.3%) were surveyed about their acceptance and use of mobile devices in medical settings. Regarding demographics, both samples were representative of the respective study population. GNU R (version 3.1.1) was used for statistical testing. Fisher's exact test, two-sided, alpha=.05 with Monte Carlo approximation, 2000 replicates, was applied to determine dependencies between two variables. RESULTS: The majority of participants already own mobile devices (doctors, 168/206, 81.6%; patients, 110/213, 51.6%). For doctors, use in a professional context does not depend on age (P=.66), professional experience (P=.80), or function (P=.34); gender was a factor (P=.009), and use was more common among male (61/135, 45.2%) than female doctors (17/67, 25%). A correlation between use of mobile devices and age (P=.001) as well as education (P=.002) was seen for patients. Minor differences regarding how mobile devices are perceived in sensitive medical contexts mostly relate to data security, patients are more critical of the devices being used for storing and processing patient data; every fifth patient opposed this, but nevertheless, 4.8% of doctors (10/206) use their devices for this purpose. Both groups voiced only minor concerns about the credibility of the provided content or the technical reliability of the devices. While 8.3% of the doctors (17/206) avoided use during patient contact because they thought patients might be unfamiliar with the devices, (25/213) 11.7% of patients expressed concerns about the technology being too complicated to be used in a health context. CONCLUSIONS: Differences in how patients and doctors perceive the use of mobile devices can be attributed to age and level of education; these factors are often mentioned as contributors of the problems with (mobile) technologies. To fully realize the potential of mobile technologies in a health care context, the needs of both the elderly as well as those who are educationally disadvantaged need to be carefully addressed in all strategies relating to mobile technology in a health context.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Le laboratoire DOMUS développe des applications pour assister les personnes en perte d'autonomie et les personnes avec des troubles cognitifs. Chaque application est ou a déjà été le sujet de plusieurs études d'utilisabilité qui permettent de les améliorer. Ces études prennent beaucoup de temps à mettre en place, car l'on rencontre souvent des problèmes de logistique (format et sensibilité des données, chercheurs répartis sur une grande aire géographique). C'est pourquoi un outil appelé GEDOPAL a été développé. Il permet de partager entre chercheurs de différents centres les données créées et utilisées lors de la mise en place des études d'utilisabilité. La conception et la réalisation de cet outil ont nécessité une réflexion en amont sur la nature et la sensibilité de ces données. Cette réflexion est l'objet du Chapitre 3. Ces études prennent aussi beaucoup de temps lors de l'analyse des résultats. De plus, certaines données créées lors de ces études, telles que les traces d'utilisation ont des volumétries trop importantes pour être analysées manuellement. C'est pourquoi nous avons créé un processus permettant d'analyser ces traces d'utilisation pour y détecter les erreurs utilisateurs dans l'espoir de les relier à des problèmes d'utilisabilité. Ce processus se compose de deux parties : la première est une analyse formelle de l'application, qui sera présentée au Chapitre 4, et la seconde l'application d'un outil d'apprentissage automatique aux traces d'utilisation pour y détecter les erreurs utilisateurs. Cet outil est présenté au Chapitre 5.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Despite their generally increasing use, the adoption of mobile shopping applications often differs across purchase contexts. In order to advance our understanding of smartphone-based mobile shopping acceptance, this study integrates and extends existing approaches from technology acceptance literature by examining two previously underexplored aspects. Firstly, the study examines the impact of different mobile and personal benefits (instant connectivity, contextual value and hedonic motivation), customer characteristics (habit) and risk facets (financial, performance, and security risk) as antecedents of mobile shopping acceptance. Secondly, it is assumed that several acceptance drivers differ in relevance subject to the perception of three mobile shopping characteristics (location sensitivity, time criticality, and extent of control), while other drivers are assumed to matter independent of the context. Based on a dataset of 410 smartphone shoppers, empirical results demonstrate that several acceptance predictors are associated with ease of use and usefulness, which in turn affect intentional and behavioral outcomes. Furthermore, the extent to which risks and benefits impact ease of use and usefulness is influenced by the three contextual characteristics. From a managerial perspective, results show which factors to consider in the development of mobile shopping applications and in which different application contexts they matter.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Safe collaboration between a robot and human operator forms a critical requirement for deploying a robotic system into a manufacturing and testing environment. In this dissertation, the safety requirement for is developed and implemented for the navigation system of the mobile manipulators. A methodology for human-robot co-existence through a 3d scene analysis is also investigated. The proposed approach exploits the advance in computing capability by relying on graphic processing units (GPU’s) for volumetric predictive human-robot contact checking. Apart from guaranteeing safety of operators, human-robot collaboration is also fundamental when cooperative activities are required, as in appliance test automation floor. To achieve this, a generalized hierarchical task controller scheme for collision avoidance is developed. This allows the robotic arm to safely approach and inspect the interior of the appliance without collision during the testing procedure. The unpredictable presence of the operators also forms dynamic obstacle that changes very fast, thereby requiring a quick reaction from the robot side. In this aspect, a GPU-accelarated distance field is computed to speed up reaction time to avoid collision between human operator and the robot. An automated appliance testing also involves robotized laundry loading and unloading during life cycle testing. This task involves Laundry detection, grasp pose estimation and manipulation in a container, inside the drum and during recovery grasping. A wrinkle and blob detection algorithms for grasp pose estimation are developed and grasp poses are calculated along the wrinkle and blobs to efficiently perform grasping task. By ranking the estimated laundry grasp poses according to a predefined cost function, the robotic arm attempt to grasp poses that are more comfortable from the robot kinematic side as well as collision free on the appliance side. This is achieved through appliance detection and full-model registration and collision free trajectory execution using online collision avoidance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A rapid, sensitive and specific method for quantifying propylthiouracil in human plasma using methylthiouracil as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid-liquid extraction using an organic solvent (ethyl acetate). The extracts were analyzed by high performance liquid chromatography coupled with electrospray tandem mass spectrometry (HPLC-MS/MS) in negative mode (ES-). Chromatography was performed using a Phenomenex Gemini C18 5μm analytical column (4.6mm×150mm i.d.) and a mobile phase consisting of methanol/water/acetonitrile (40/40/20, v/v/v)+0.1% of formic acid. For propylthiouracil and I.S., the optimized parameters of the declustering potential, collision energy and collision exit potential were -60 (V), -26 (eV) and -5 (V), respectively. The method had a chromatographic run time of 2.5min and a linear calibration curve over the range 20-5000ng/mL. The limit of quantification was 20ng/mL. The stability tests indicated no significant degradation. This HPLC-MS/MS procedure was used to assess the bioequivalence of two propylthiouracil 100mg tablet formulations in healthy volunteers of both sexes in fasted and fed state. The geometric mean and 90% confidence interval CI of Test/Reference percent ratios were, without and with food, respectively: 109.28% (103.63-115.25%) and 115.60% (109.03-122.58%) for Cmax, 103.31% (100.74-105.96%) and 103.40% (101.03-105.84) for AUClast. This method offers advantages over those previously reported, in terms of both a simple liquid-liquid extraction without clean-up procedures, as well as a faster run time (2.5min). The LOQ of 20ng/mL is well suited for pharmacokinetic studies. The assay performance results indicate that the method is precise and accurate enough for the routine determination of the propylthiouracil in human plasma. The test formulation with and without food was bioequivalent to reference formulation. Food administration increased the Tmax and decreased the bioavailability (Cmax and AUC).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Instrumented indentation has been used to investigate the mechanical properties of BETAMATE 1496 (R) Epoxy adhesive. The properties of the adhesive were analyzed by measuring its hardness and its Young`s modulus in samples extracted from six different positions of the front door of a commercial passenger vehicle in two phases of processing: after application of the adhesive in the door assembling (""pre-cured"" state) and after final cure in the painting oven (""cured"" state). Special attention was given to setting the optimal parameters (""creep"" time and unloading time step) for the instrumented indentation testing for the present application. Young`s modulus values around 1.1 +/- 0.2 GPa and hardness values around 0.15 +/- 0.05 GPa were obtained for all samples, irrespective of the variation of the indentation parameters in the testing procedure and of the relative position of the adhesive in the door frame in both states. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple, rapid, selective and sensitive analytical method by HPLC with UV detection was developed for the quantification of carbamazepine, phenobarbital and phenytoin in only 0.2 mL of plasma. A C18 column (150 x 3.9 mm, 4 micra) using a binary mobile phase consisting of water and acetonitrile (70:30, v/v) at a flow rate of 0.5 mL/min were proposed. Validation of the analytical method showed a good linearity (0.3 to 20.0 mg/L for CBZ, 0.9 to 60.0 mg/L for PB and 0.6 to 40.0 mg/L for PHT), high sensitivity (LOQ: 0.3, 0.9 and 0.6 mg/L respectively). The method was applied for drug monitoring of antiepileptic drugs (AED) in 27 patients with epilepsy under polytherapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study, a simple, rapid and sensitive HPLC method with UV detection is described for determination of metformin in plasma samples from bioequivalence assays. Sample preparation was accomplished through protein precipitation with acetonitrile and chromatographic separation was performed on a reversed-phase phenyl column at 40 degrees C. Mobile phase consisted of a mixture of phosphate buffer and acetonitrile at flow rate of 1.0 ml/min. Wavelength was set at 236 nm. The method was applied to a bioequivalence study of two drug products containing metformin, and allowed determination of metformin at low concentrations with a higher throughput than previously described methods. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An enantioselective liquid chromatographic method using two-phase hollow fiber liquid-phase microextraction (HF-LPME-HPLC) was developed for the determination of isradipine (ISR) enantiomers and its main metabolite (pyridine derivative of isradipine, PDI) in microsomal fractions isolated from rat liver. The analytes were extracted from 1 mL of microsomal medium using a two-phase HF-LPME procedure with hexyl acetate as the acceptor phase, 30 min of extraction, and sample agitation at 1,500 rpm. For the first time, ISR enantiomers and PDI were resolved. For this separation, a ChiralpakA (R) AD column with hexane/2-propanol/ethanol (94:04:02, v/v/v) as the mobile phase at a flow rate of 1.5 mL min(-1) was used. The column was kept at 23 A +/- 2 A degrees C. The drug and metabolite detection was performed at 325 nm and the internal standard oxybutynin was detected at 225 nm. The recoveries were 23% for PDI and 19% for each ISR enantiomer. The method presented quantification limits (LOQ) of 50 ng mL(-1) and was linear over the concentration range of 50-5,000 and 50-2,500 ng mL(-1) for PDI and each ISR enantiomer, respectively. The validated method was employed to an in vitro biotransformation study of ISR using rat liver microsomal fraction showing that (+)-(S)-ISR is preferentially biotransformed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was the development and validation of an LC-MS-MS method for simultaneous analysis of ibuprofen (IBP), 2-hydroxyibuprofen (2-OH-IBP) enantiomers, and carboxyibuprofen (COOH-IBP) stereoisomers in fungi culture medium, to investigate the ability of some endophytic fungi to biotransform the chiral drug IBP into its metabolites. Resolution of IBP and the stereoisomers of its main metabolites was achieved by use of a Chiralpak AS-H column (150 x 4.6 mm, 5 mu m particle size), column temperature 8 degrees C, and the mobile phase hexane-isopropanol-trifluoroacetic acid (95: 5: 0.1, v/v) at a flow rate of 1.2 mL min(-1). Post-column infusion with 10 mmol L(-1) ammonium acetate in methanol at a flow rate of 0.3 mL min(-1) was performed to enhance MS detection (positive electrospray ionization). Liquid-liquid extraction was used for sample preparation with hexane-ethyl acetate (1:1, v/v) as extraction solvent. Linearity was obtained in the range 0.1-20 mu g mL(-1) for IBP, 0.05-7.5 mu g mL(-1) for each 2-OH-IBP enantiomer, and 0.025-5.0 mu g mL(-1) for each COOH-IBP stereoisomer (r >= 0.99). The coefficients of variation and relative errors obtained in precision and accuracy studies (within-day and between-day) were below 15%. The stability studies showed that the samples were stable (p > 0.05) during freeze and thaw cycles, short-term exposure to room temperature, storage at -20 degrees C, and biotransformation conditions. Among the six fungi studied, only the strains Nigrospora sphaerica (SS67) and Chaetomium globosum (VR10) biotransformed IBP enantioselectively, with greater formation of the metabolite (+)-(S)-2-OH-IBP. Formation of the COOH-IBP stereoisomers, which involves hydroxylation at C3 and further oxidation to form the carboxyl group, was not observed.