855 resultados para Measurement in Bacteriology
Resumo:
The objective of this study was to compare a GnRH-based to an estrogen/progesterone (E2/P4)-based protocol for estrous cycle synchronization and fixed timed artificial insemination (TAI), both designed for synchronization of ovulation and to reduce the period from follicular emergence until ovulation in cows with a synchronized follicular wave. A total of 1,190 lactating Holstein cows (primiparous: n = 685 and multiparous: n = 505) yielding 26.5 ± 0.30 kg of milk/d at 177 ± 5.02 d in milk were randomly assigned to receive one of the following programs: 5-d Cosynch protocol [d -8: controlled internal drug release (CIDR) + GnRH; d -3: CIDR removal + PGF2α; d -2: PGF2α; d 0: TAI + GnRH] or E2/P4 protocol (d -10: CIDR + estradiol benzoate; d -3: PGF2α; d -2: CIDR removal + estradiol cypionate; d 0: TAI). Rectal temperature and circulating progesterone (P4) were measured on d -3, -2, 0 (TAI), and 7. The estrous cycle was considered to be synchronized when P4 was ≥1.0 ng/mL on d 7 in cows that had luteolysis (P4 ≤0.4 ng/mL on d 0). To evaluate the effects of heat stress, cows were classified by number of heat stress events: 0, 1, and 2-or-more measurements of elevated body temperature (≥39.1°C). Pregnancy success (pregnancy per artificial insemination, P/AI) was determined at d 32 and 60 after TAI. The cows in the 5-d Cosynch protocol had increased circulating P4 at the time of PGF2α injection (2.66 ± 0.13 vs. 1.66 ± 0.13 ng/mL). The cows in the E2/P4 protocol were more likely to be detected in estrus (62.8 vs. 43.4%) compared with the cows in the 5-d Cosynch protocol, and expression of estrus improved P/AI in both treatments. The cows in the 5-d Cosynch protocol had greater percentage of synchronized estrous cycle (78.2%), compared with cows in the E2/P4 protocol (70.7%). On d 60, the E2/P4 protocol tended to improve P/AI (20.7 vs. 16.7%) and reduced pregnancy loss from 32 to 60 d (11.0 vs. 19.6%), compared with the 5-d Cosynch protocol. In cows with their estrous cycle synchronized, the E2/P4 protocol had greater P/AI (25.6 vs. 17.7%) on d 60 and lower pregnancy loss from 32 to 60 d (6.7 vs. 21.7%) compared with cows in the 5-d Cosynch protocol. Follicle diameter affected pregnancy loss from 32 to 60 d only in the cows in the 5-d Cosynch protocol, with smaller follicles resulting in greater pregnancy loss. Pregnancy per AI at d 60 was different between protocols in the cows with 2 or more measurements of heat stress (5-d Cosynch = 12.2% vs. E2/P4 = 22.8%), but not in the cows without or with 1 heat stress measurement. In conclusion, the 5-d Cosynch protocol apparently produced better estrous cycle synchronization than the E2/P4 protocol but did not improve P/AI. The potential explanation for these results is that increased E2 concentrations during the periovulatory period can improve pregnancy success and pregnancy maintenance, and this effect appears to be greatest in heat-stressed cows when circulating E2 may be reduced. © 2013 American Dairy Science Association.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
OBJETIVO:Revisar a literatura sobre estudos que estimaram a prevalência de pressão arterial elevada (PAE) ou hipertensão arterial sistêmica (HAS) em adolescentes brasileiros, considerando os procedimentos metodológicos empregados.MÉTODOS:Pesquisa bibliográfica de estudos de prevalência de PAE/HAS em adolescentes de 1995 a 2010. A busca foi realizada nas bases de dados eletrônicos PubMed/Medline, Lilacs, SciELO, Isi e Adolec. Foram utilizados os descritores: hipertensão, pressão arterial, adolescente, estudantes, estudos transversais, prevalência e Brasil, nas línguas portuguesa e inglesa. Além disso, foi elaborado um escore, baseado nas Recommendations for Blood Pressure Measurement in Humans and Experimental Animals e nas VI Diretrizes Brasileiras de Hipertensão, para a análise dos procedimentos utilizados para medida da PA nos estudos variando de 0 a 18.RESULTADOS:Foram identificados 21 artigos, a maioria publicada nos últimos 10 anos, sendo 90,5% realizados em base escolar e nas regiões sudeste, nordeste e sul do país. As prevalências de PAE/HAS variaram de 2,5 a 30,9%. A pontuação dos estudos variou de 0 a 16. Foi observada uma correlação negativa significante (rho = -0,504; p = 0,020) entre a prevalência de PAE/HAS e o escore da qualidade da medida da PA.CONCLUSÃO:A grande variabilidade das estimativas da PAE/HAS parece ser influenciada pelos procedimentos metodológicos utilizados nos estudos.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Background The paucity of studies regarding cognitive function in patients with chronic pain, and growing evidence regarding the cognitive effects of pain and opioids on cognitive function prompted us to assess cognition via neuropsychological measurement in patients with chronic non-cancer pain treated with opioids. Methods In this cross-sectional study, 49 patients were assessed by Continuous Reaction Time, Finger Tapping, Digit Span, Trail Making Test-B and Mini-mental State Examination tests. Linear regressions were applied. Results Patients scored poorly in the Trail Making Test-B (mean?=?107.6?s, SD?=?61.0, cut-off?=?91?s); and adequately on all other tests. Several associations among independent variables and cognitive tests were observed. In the multiple regression analyses, the variables associated with statistically significant poor cognitive performance were female sex, higher age, lower annual income, lower schooling, anxiety, depression, tiredness, lower opioid dose, and more than 5?h of sleep the night before assessment (P?<?0.05). Conclusions Patients with chronic pain may have cognitive dysfunction related to some reversible factors, which can be optimized by therapeutic interventions.
Resumo:
This new and general method here called overflow current switching allows a fast, continuous, and smooth transition between scales in wide-range current measurement systems, like electrometers. This is achieved, using a hydraulic analogy, by diverting only the overflow current, such that no slow element is forced to change its state during the switching. As a result, this approach practically eliminates the long dead time in low-current (picoamperes) switching. Similar to a logarithmic scale, a composition of n adjacent linear scales, like a segmented ruler, measures the current. The use of a linear wide-range system based on this technique assures fast and continuous measurement in the entire range, without blind regions during transitions and still holding suitable accuracy for many applications. A full mathematical development of the method is given. Several computer realistic simulations demonstrated the viability of the technique.
Resumo:
Objectives: To compare, in vivo, the accuracy of conventional and digital radiographic methods in determining root canal working length. Material and Methods: Twenty-five maxillary incisor or canine teeth from 22 patients were used in this study. Considering the preoperative radiographs as the baseline, a 25 K file was inserted into the root canal to the point where the Root ZX electronic apex locator indicated the APEX measurement in the screen. From this measurement, 1 mm was subtracted for positioning the file. The radiographic measurements were made using a digital sensor (Digora 1.51) or conventional type-E films, size 2, following the paralleling technique, to determine the distance of the file tip and the radiographic apex. Results: The Student "t" test indicated mean distances of 1.11 mm to conventional and 1.20 mm for the digital method and indicated a significant statistical difference (p<0.05). Conclusions: The conventional radiographic method was found to be superior to the digital one in determining the working length of the root canal.
Resumo:
Objective Genetic sonography following first-trimester combined screening appears to increase substantially detection rates for Down syndrome but it relies on the unproved assumption of independence between these tests. In this study we aimed to investigate the relationship between first-trimester nuchal translucency (NT) and a series of second-trimester soft markers and structural defects in unaffected pregnancies. Methods NT measurement in the first trimester was followed by second-trimester scan (18 to 23 + 6 weeks) including examination for three categorical markers (intracardiac echogenic foci, hyperechogenic bowel and structural defects) and measurement of nasal bone length, nuchal-fold thickness, femur length, humerus length, renal pelvis diameter and prenasal thickness. All continuous variables were expressed in multiples of the median (MoM) for gestation and correlation coefficients between log-transformed NT and second-trimester variables were calculated. In addition, frequencies of soft markers and structural defects in cases with increased NT were compared to those with normal NT, using MoM cut-offs. Results In a dataset of 1970 cases, NT was significantly correlated (P < 0.05) with all second-trimester continuous variables, the correlation being strongest for nuchal-fold thickness (r = 0.10). There was a higher frequency of cases with second-trimester nuchal-fold thickness above the 97.5th centile (10.7 vs. 2.2%) and hyperechogenic bowel (2.4 vs. 0.1%) in cases with increased NT. Conclusions Straightforward reassessment of risk using likelihood ratios derived from the second-trimester genetic sonogram might lead to inaccurate estimates. Multivariate models using continuous second-trimester variables might be preferable in sequential screening strategies. Copyright. 2012 ISUOG. Published by John Wiley & Sons, Ltd.
Resumo:
The escape response to electrical or chemical stimulation of the dorsal periaqueductal gray matter (DPAG) has been associated with panic attacks. In order to explore the validity of the DPAG stimulation model for the study of panic disorder, we determined if the aversive consequences of the electrical or chemical stimulation of this midbrain area can be detected subsequently in the elevated T-maze. This animal model, derived from the elevated plus-maze, permits the measurement in the same rat of a generalized anxiety- and a panic-related defensive response, i.e., inhibitory avoidance and escape, respectively. Facilitation of inhibitory avoidance, suggesting an anxiogenic effect, was detected in male Wistar rats (200-220 g) tested in the elevated T-maze 30 min after DPAG electrical stimulation (current generated by a sine-wave stimulator, frequency at 60 Hz) or after local microinjection of the GABA A receptor antagonist bicuculline (5 pmol). Previous electrical (5, 15, 30 min, or 24 h before testing) or chemical stimulation of this midbrain area did not affect escape performance in the elevated T-maze or locomotion in an open-field. No change in the two behavioral tasks measured by the elevated T-maze was observed after repetitive (3 trials) electrical stimulation of the DPAG. The results indicate that activation of the DPAG caused a short-lived, but selective, increase in defensive behaviors associated with generalized anxiety.
Resumo:
In the context of “testing laboratory” one of the most important aspect to deal with is the measurement result. Whenever decisions are based on measurement results, it is important to have some indication of the quality of the results. In every area concerning with noise measurement many standards are available but without an expression of uncertainty, it is impossible to judge whether two results are in compliance or not. ISO/IEC 17025 is an international standard related with the competence of calibration and testing laboratories. It contains the requirements that testing and calibration laboratories have to meet if they wish to demonstrate that they operate to a quality system, are technically competent and are able to generate technically valid results. ISO/IEC 17025 deals specifically with the requirements for the competence of laboratories performing testing and calibration and for the reporting of the results, which may or may not contain opinions and interpretations of the results. The standard requires appropriate methods of analysis to be used for estimating uncertainty of measurement. In this point of view, for a testing laboratory performing sound power measurement according to specific ISO standards and European Directives, the measurement of uncertainties is the most important factor to deal with. Sound power level measurement, according to ISO 3744:1994 , performed with a limited number of microphones distributed over a surface enveloping a source is affected by a certain systematic error and a related standard deviation. Making a comparison of measurement carried out with different microphone arrays is difficult because results are affected by systematic errors and standard deviation that are peculiarities of the number of microphones disposed on the surface, their spatial position and the complexity of the sound field. A statistical approach could give an overview of the difference between sound power level evaluated with different microphone arrays and an evaluation of errors that afflict this kind of measurement. Despite the classical approach that tend to follow the ISO GUM this thesis present a different point of view of the problem related to the comparison of result obtained from different microphone arrays.
Resumo:
Im Rahmen der vorliegenden Arbeit wurden zum ersten Mal kalorimetrische Tieftemperatur-Detektoren in der Beschleuniger-Massenspektrometrie (Accelerator Mass Spectrometry AMS), einer Standard-Methode zur Bestimmung kleinster Isotopenverhältnisse, eingesetzt, um das Isotopenverhältnis von 236U zu 238U zu bestimmen. Das Uran-Isotop 236U entsteht in der Neutroneneinfang-Reaktion 235U(n,gamma)236U und kann daher als Monitor-Nuklid für Neutronenflüsse verwendet werden. Die Detektoren bestehen aus einem Saphir-Absorber, auf den ein supraleitender Aluminium-Film aufgedampft ist, der als Thermistor dient. Ein energetisches Schwerion deponiert seine kinetische Energie als Wärme im Absorber, dessen Temperaturänderung durch die Widerstandsänderung des Supraleiters nachgewiesen wird. Mit solchen Detektoren konnte in vorhergehenden Experimenten bei GSI in einem Energiebereich von E = 5 - 300 MeV/amu für eine Vielzahl von Ionen von Neon bis Uran eine relative Energieauflösung von (1 - 4) E-3 erreicht werden. Der für die Beschleuniger-Massenspektrometrie typische Energiebereich liegt bei E = 0.1 - 1 MeV/amu. Im ersten Schritt wurde daher die systematische Untersuchung der Detektoreigenschaften auf diesen Energiebereich ausgedehnt. Diese Untersuchungen sowie die AMS-Messungen wurden am Tandem-Beschleuniger VERA des Instituts für Isotopenforschung und Kernphysik der Universität Wien durchgeführt. In einem Energiebereich von 10 - 60 MeV konnte für verschiedene Ionen (13C, 197Au, 238U) zunächst eine relative Energieauflösung von DeltaE/E = 7 E-3 erreicht werden. Dies übertrifft die Auflösung konventioneller Ionisations-Detektoren um ca. eine Größenordnung. Durch eine Verbesserung thermischer und elektronischer Rauschbeiträge konnte in einem zweiten Experiment für Uran der Energie 17 MeV die Auflösung auf DeltaE/E = 4.6 E-3 verbessert werden. Die Energie-Response des Detektors war linear über den gesamten beobachteten Energiebereich und unabhängig von der Ionenmasse; bis auf ein Niveau von 0.1 % wurde kein Pulshöhendefekt beobachtet. Diese Ergebnisse zeigen, daß solche Detektoren ein wertvolles Werkzeug in der Schwerionenphysik im Bereich relativ niedriger Ionenenergien darstellen. Mit der erreichten Energieauflösung war es möglich, für mehrere Proben aus natürlichem Uran das Isotopenverhältnis 236U/238U zu bestimmen: Um einen Material-Standard für Uran in der AMS zu etablieren, wurde das Isotopenverhältnis 236U/238U für zwei Proben aus der Mine ''K.u.K. Joachimsthal'' möglichst präzise bestimmt. Die Ergebnisse in der vorliegenden Arbeit stimmen gut mit früheren Messungen überein, die mit einem konventionellen Detektorsystem durchgeführt wurden. Sowohl der statistische als auch der systematische Fehler konnten deutlich reduziert werden. Für eine weitere Probe, extrahiert aus dem Wasser einer Uran-haltigen Quelle in Bad Gastein, wurde ein Isotopenverhältnis von 6.1 E-12 gemessen. Dies stellt das kleinste bislang für 236U/238U gemessene Isotopenverhältnis dar und bedeutet eine Steigerung der Sensitivität um eine Größenordnung. Die erreichte Energieauflösung ermöglicht es außerdem, die Detektoren zur direkten Massenidentifikation von schweren Ionen mittels einer kombinierten Energie-Flugzeit-Messung einzusetzen. In ersten Test-Messungen im Rahmen der vorliegenden Arbeit wurde eine Massenauflösung von DeltaM/M = (8.5 - 11.0) E-3 erreicht. In einem ersten Test für den Einsatz dieser Detektoren zum Nachweis sog. ''superschwerer Elemente (Z >= 112)'' erlaubte der große dynamische Bereich, die Reaktionsprodukte und ihre nachfolgenden Alpha-Zerfälle mit hoher Energieauflösung simultan und zeitaufgelöst nachzuweisen.
Resumo:
It has been demonstrated that iodine does have an important influence on atmospheric chemistry, especially the formation of new particles and the enrichment of iodine in marine aerosols. It was pointed out that the most probable chemical species involved in the production or growth of these particles are iodine oxides, produced photochemically from biogenic halocarbon emissions and/or iodine emission from the sea surface. However, the iodine chemistry from gaseous to particulate phase in the coastal atmosphere and the chemical nature of the condensing iodine species are still not understood. A Tenax / Carbotrap adsorption sampling technique and a thermo-desorption / cryo-trap / GC-MS system has been further developed and improved for the volatile organic iodine species in the gas phase. Several iodo-hydrocarbons such as CH3I, C2H5I, CH2ICl, CH2IBr and CH2I2 etc., have been measured in samples from a calibration test gas source (standards), real air samples and samples from seaweeds / macro-algae emission experiments. A denuder sampling technique has been developed to characterise potential precursor compounds of coastal particle formation processes, such as molecular iodine in the gas phase. Starch, TMAH (TetraMethylAmmonium Hydroxide) and TBAH (TetraButylAmmonium Hydroxide) coated denuders were tested for their efficiencies to collect I2 at the inner surface, followed by a TMAH extraction and ICP/MS determination, adding tellurium as an internal standard. The developed method has been proved to be an effective, accurate and suitable process for I2 measurement in the field, with the estimated detection limit of ~0.10 ng∙L-1 for a sampling volume of 15 L. An H2O/TMAH-Extraction-ICP/MS method has been developed for the accurate and sensitive determination of iodine species in tropospheric aerosol particles. The particle samples were collected on cellulose-nitrate filters using conventional filter holders or on cellulose nitrate/tedlar-foils using a 5-stage Berner impactor for size-segregated particle analysis. The water soluble species as IO3- and I- were separated by anion exchanging process after water extraction. Non-water soluble species including iodine oxide and organic iodine were digested and extracted by TMAH. Afterwards the triple samples were analysed by ICP/MS. The detection limit for particulate iodine was determined to be 0.10~0.20 ng•m-3 for sampling volumes of 40~100 m3. The developed methods have been used in two field measurements in May 2002 and September 2003, at and around the Mace Head Atmospheric Research Station (MHARS) located at the west coast of Ireland. Elemental iodine as a precursor of the iodine chemistry in the coastal atmosphere, was determined in the gas phase at a seaweed hot-spot around the MHARS, showing I2 concentrations were in the range of 0~1.6 ng∙L-1 and indicating a positive correlation with the ozone concentration. A seaweed-chamber experiment performed at the field measurement station showed that the I2 emission rate from macro-algae was in the range of 0.019~0.022 ng•min-1•kg-1. During these experiments, nanometer-particle concentrations were obtained from the Scanning Mobility Particle Sizer (SMPS) measurements. Particle number concentrations were found to have a linear correlation with elemental iodine in the gas phase of the seaweeds chamber, showing that gaseous I2 is one of the important precursors of the new particle formation in the coastal atmosphere. Iodine contents in the particle phase were measured in both field campaigns at and around the field measurement station. Total iodine concentrations were found to be in the range of 1.0 ~ 21.0 ng∙m-3 in the PM2.5 samples. A significant correlation between the total iodine concentrations and the nanometer-particle number concentrations was observed. The particulate iodine species analysis indicated that iodide contents are usually higher than those of iodate in all samples, with ratios in the range of 2~5:1. It is possible that those water soluble iodine species are transferred through the sea-air interface into the particle phase. The ratio of water soluble (iodate + iodide) and non-water soluble species (probably iodine oxide and organic iodine compounds) was observed to be in the range of 1:1 to 1:2. It appears that higher concentrated non-water soluble species, as the products of the photolysis from the gas phase into the particle phase, can be obtained in those samples while the nucleation events occur. That supports the idea that iodine chemistry in the coastal boundary layer is linked with new particle formation events. Furthermore, artificial aerosol particles were formed from gaseous iodine sources (e.g. CH2I2) using a laboratory reaction-chamber experiment, in which the reaction constant of the CH2I2 photolysis was calculated to be based upon the first order reaction kinetic. The end products of iodine chemistry in the particle phase were identified and quantified.
Resumo:
In this thesis we describe in detail the Monte Carlo simulation (LVDG4) built to interpret the experimental data collected by LVD and to measure the muon-induced neutron yield in iron and liquid scintillator. A full Monte Carlo simulation, based on the Geant4 (v 9.3) toolkit, has been developed and validation tests have been performed. We used the LVDG4 to determine the active vetoing and the shielding power of LVD. The idea was to evaluate the feasibility to host a dark matter detector in the most internal part, called Core Facility (LVD-CF). The first conclusion is that LVD is a good moderator, but the iron supporting structure produce a great number of neutrons near the core. The second conclusions is that if LVD is used as an active veto for muons, the neutron flux in the LVD-CF is reduced by a factor 50, of the same order of magnitude of the neutron flux in the deepest laboratory of the world, Sudbury. Finally, the muon-induced neutron yield has been measured. In liquid scintillator we found $(3.2 \pm 0.2) \times 10^{-4}$ n/g/cm$^2$, in agreement with previous measurements performed at different depths and with the general trend predicted by theoretical calculations and Monte Carlo simulations. Moreover we present the first measurement, in our knowledge, of the neutron yield in iron: $(1.9 \pm 0.1) \times 10^{-3}$ n/g/cm$^2$. That measurement provides an important check for the MC of neutron production in heavy materials that are often used as shield in low background experiments.
Resumo:
Die chronisch obstruktive Lungenerkrankung (engl. chronic obstructive pulmonary disease, COPD) ist ein Überbegriff für Erkrankungen, die zu Husten, Auswurf und Dyspnoe (Atemnot) in Ruhe oder Belastung führen - zu diesen werden die chronische Bronchitis und das Lungenemphysem gezählt. Das Fortschreiten der COPD ist eng verknüpft mit der Zunahme des Volumens der Wände kleiner Luftwege (Bronchien). Die hochauflösende Computertomographie (CT) gilt bei der Untersuchung der Morphologie der Lunge als Goldstandard (beste und zuverlässigste Methode in der Diagnostik). Möchte man Bronchien, eine in Annäherung tubuläre Struktur, in CT-Bildern vermessen, so stellt die geringe Größe der Bronchien im Vergleich zum Auflösungsvermögen eines klinischen Computertomographen ein großes Problem dar. In dieser Arbeit wird gezeigt wie aus konventionellen Röntgenaufnahmen CT-Bilder berechnet werden, wo die mathematischen und physikalischen Fehlerquellen im Bildentstehungsprozess liegen und wie man ein CT-System mittels Interpretation als lineares verschiebungsinvariantes System (engl. linear shift invariant systems, LSI System) mathematisch greifbar macht. Basierend auf der linearen Systemtheorie werden Möglichkeiten zur Beschreibung des Auflösungsvermögens bildgebender Verfahren hergeleitet. Es wird gezeigt wie man den Tracheobronchialbaum aus einem CT-Datensatz stabil segmentiert und mittels eines topologieerhaltenden 3-dimensionalen Skelettierungsalgorithmus in eine Skelettdarstellung und anschließend in einen kreisfreien Graphen überführt. Basierend auf der linearen System Theorie wird eine neue, vielversprechende, integral-basierte Methodik (IBM) zum Vermessen kleiner Strukturen in CT-Bildern vorgestellt. Zum Validieren der IBM-Resultate wurden verschiedene Messungen an einem Phantom, bestehend aus 10 unterschiedlichen Silikon Schläuchen, durchgeführt. Mit Hilfe der Skelett- und Graphendarstellung ist ein Vermessen des kompletten segmentierten Tracheobronchialbaums im 3-dimensionalen Raum möglich. Für 8 zweifach gescannte Schweine konnte eine gute Reproduzierbarkeit der IBM-Resultate nachgewiesen werden. In einer weiteren, mit IBM durchgeführten Studie konnte gezeigt werden, dass die durchschnittliche prozentuale Bronchialwandstärke in CT-Datensätzen von 16 Rauchern signifikant höher ist, als in Datensätzen von 15 Nichtrauchern. IBM läßt sich möglicherweise auch für Wanddickenbestimmungen bei Problemstellungen aus anderen Arbeitsgebieten benutzen - kann zumindest als Ideengeber dienen. Ein Artikel mit der Beschreibung der entwickelten Methodik und der damit erzielten Studienergebnisse wurde zur Publikation im Journal IEEE Transactions on Medical Imaging angenommen.