930 resultados para Mamary ultrasound


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The sonochemical oxidation efficiency (eta(ox)) of a commercial titanium alloy ultrasound horn has been measured using potassium iodide as a dosimeter at its main resonance frequency (20 kHz) and two higher resonance frequencies (41 and 62 kHz). Narrow power and frequency ranges have been chosen to minimise secondary effects such as changing bubble stability, and time available for radical diffusion from the bubble to the liquid. The oxidation efficiency, eta(ox), is proportional to the frequency and to the power transmitted to the liquid (275 mL) in the applied power range (1-6 W) under argon. Luminol radical visualisation measurements show that the radical generation rate increases and a redistribution of radical producing zones is achieved at increasing frequency. Argon, helium, air, nitrogen, oxygen, and carbon dioxide have been used as saturation gases in potassium iodide oxidation experiments. The highest eta(ox) has been observed at 5 W under air at 62 kHz. The presence of carbon dioxide in air gives enhanced nucleation at 41 and 62 kHz and has a strong influence on eta(ox). This is supported by the luminol images, the measured dependence of eta(ox). on input power, and bubble images recorded under carbon dioxide. The results give insight into the interplay between saturation gas and frequency, nucleation, and their effect on eta(ox). (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Scission of a supramolecular polymer-metal complex can be carried out using collapsing cavitation bubbles created by ultrasound. Although the most plausible scission mechanism of the coordinative bonds is through mechanical force, the influence of radicals and high hot-spot temperatures on scission has to be considered. A silver(I)-N-heterocyclic carbene complex was exposed to 20 kHz ultrasound in argon, nitrogen, methane, and isobutane saturated toluene. Scission percentages were almost equal under argon, nitrogen, and methane. Radical production differs by a factor of 10 under these gases, indicating that radical production is not a significant contributor to the scission process. A model to describe the displacement of the bubble wall, strain rates, and temperature in the gas shows that critical strain rates for coil-to-stretch transition, needed for scission, are achieved at reactor temperatures of 298 K, an acoustic pressure of 1.2 x 10(5) Pa, and an acoustic frequency of 20 kHz. Lower scission percentages were measured under isobutane, which also shows lower strain rates in model simulations. The activation of the polymer-metal complexes in toluene under the influence of ultrasound occurs through mechanical force.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The initial rate of oxidation of octan-2-ol and other secondary alcohols to their ketones with NaBrO3, mediated by RuO4 in an aqueous-CCl4 biphasic system, is greater with ultrasonic irradiation than by stirring alone. Under ultrasonic irradiation the initial rate of oxidation of octan-2-ol increases with increasing % duty cycle, [RuO4] and [NaBrO3]. The kinetics of alcohol oxidation appear to be closely linked with the oxidative dissolution of RuO2 to RuO4 by NaBrO3. The observed enhancement in rate with ultrasonic irradiation appear to be association, at least in part, with the increase in interfacial surface area via the formation of an emulsion of aqueous microdroplets containing NaBrO3 in the CCl4 layer containing the non-water-soluble secondary alcohol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasound promotes the reduction of hexacyanoferrate(III) by thiosulfate ions mediated by RuO2 . xH(2)O under diffusion-controlled conditions. There is a strong correlation between the measured first-order rate constant and the absorbance of the dispersion, which, in turn, is closely related to the specific surface area of the catalyst. The enhancement in rate with ultrasonic irradiation appears to be largely associated with the dispersive action of the ultrasound on the aggregated particles of RuO2 . xH(2)O. The rate of reaction increases with increasing %duty cycle and ultrasonic intensity. The measured overall activation energies for the reaction with and without ultrasound, i.e. 18 +/- 1 and 20 +/- 1 kJ mol(-1), respectively, are very similar to those expected for a diffusion-controlled reaction. The homogeneous reaction is not promoted by ultrasound.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of continuous sonication and presonication on the kinetics of oxidative dissolution of ruthenium dioxide hydrate by bromate ions under acidic conditions are reported. Compared with unsonicated and presonicated dispersions the overall rate of dissolution of continuously sonicated dispersions is significantly greater due to a reduction in the average particle size and, hence, an increase in the specific surface area. Powder dispersions subjected to continuous ultrasound and presonication exhibit an initial induction period in their corrosion kinetics; the length of this induction period increases with increasing presonication. This corrosion feature is retained in the dissolution kinetics of powder samples which have been subjected to pre-ultrasound, but which are then stirred during the dissolution process. It is believed that this apparent permanent change in the nature of the powder particles is due to the ultrasound induced formation of a very thin layer of a largely unreactive form of ruthenium dioxide (possibly due to partial dehydration) on the surface of the powder particles. A kinetic scheme, based on this model, is used to account for the observed kinetics of dissolution of RuO2 . xH2O which have been subjected to both continuous sonication and presonication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of ultrasound on the percutaneous absorption of three nicotinate esters was investigated in 10 healthy volunteers in a double-blind placebo controlled crossover clinical trial. Using a specially designed experimental protocol, the effect of continuous output ultrasound (at frequency 3.0 MHz and intensity 1.0 W/cm2 for 5 min) on the percutaneous absorption of methyl, ethyl, and hexyl nicotinates, from gel bases, was investigated. A placebo control, involving massage with each of the gels, without ultrasound for 5 min, was also incorporated. The pharmacodynamic parameter of vasodilation caused by the nicotinates was used to monitor the percutaneous absorption of the drugs. Laser Doppler velocimetry, a noninvasive optical technique, was used to measure vasodilation of the cutaneous vessels within the treatment site. Ultrasound treatment led to enhanced vasodilator response to the nicotinates, therefore indicating an enhancement of their percutaneous absorption. These agents may prove to be useful compounds in examination of the mechanism of action of phonophoresis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Routine intravenous cholangiography using the safer contrast medium, meglumine iotroxate, may be a useful investigation prior to laparoscopic cholecystectomy for the detection of suspected common bile duct stones. We compared this with endoscopic cholangiography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the association between different neonatal ultrasonographic classifications and adolescent cognitive, educational, and behavioral outcomes following very preterm birth. Participants included a group of 120 adolescents who were born very preterm (33 weeks of gestation), subdivided into three groups according to their neonatal cerebral ultrasound (US) classifications: (a) normal (N = 69), (b) periventricular hemorrhage (PVH, N = 37), and (c) PVH with ventricular dilatation (PVH + DIL, N = 14), and 50 controls. The cognitive functions assessed were full-scale IQ, phonological and semantic verbal fluency, and visual-motor integration. Educational outcomes included reading and spelling; behavioral outcomes were assessed with the Rutter Parents' Scale and the Premorbid Adjustment Scale (PAS). Adolescent outcome scores were compared among the four groups. A main effect for group was observed for full-scale IQ, Rutter Parents' Scale total scores, and PAS total scores, after controlling for gestational age, socioeconomic status and gender, with the PVH + DIL group showing the most impaired scores compared to the other groups. The current results demonstrate that routine neonatal ultrasound classifications are associated with later cognitive and behavioral outcome. Neonatal ultrasounds could aid in the identification of subgroups of children who are at increased risk of neurodevelopmental problems. These at risk subgroups could then be referred to appropriate early intervention services.