417 resultados para MONITORS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Physiologic data display is essential to decision making in critical care. Current displays echo first-generation hemodynamic monitors dating to the 1970s and have not kept pace with new insights into physiology or the needs of clinicians who must make progressively more complex decisions about their patients. The effectiveness of any redesign must be tested before deployment. Tools that compare current displays with novel presentations of processed physiologic data are required. Regenerating conventional physiologic displays from archived physiologic data is an essential first step. OBJECTIVES: The purposes of the study were to (1) describe the SSSI (single sensor single indicator) paradigm that is currently used for physiologic signal displays, (2) identify and discuss possible extensions and enhancements of the SSSI paradigm, and (3) develop a general approach and a software prototype to construct such "extended SSSI displays" from raw data. RESULTS: We present Multi Wave Animator (MWA) framework-a set of open source MATLAB (MathWorks, Inc., Natick, MA, USA) scripts aimed to create dynamic visualizations (eg, video files in AVI format) of patient vital signs recorded from bedside (intensive care unit or operating room) monitors. Multi Wave Animator creates animations in which vital signs are displayed to mimic their appearance on current bedside monitors. The source code of MWA is freely available online together with a detailed tutorial and sample data sets.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper aims at the development and evaluation of a personalized insulin infusion advisory system (IIAS), able to provide real-time estimations of the appropriate insulin infusion rate for type 1 diabetes mellitus (T1DM) patients using continuous glucose monitors and insulin pumps. The system is based on a nonlinear model-predictive controller (NMPC) that uses a personalized glucose-insulin metabolism model, consisting of two compartmental models and a recurrent neural network. The model takes as input patient's information regarding meal intake, glucose measurements, and insulin infusion rates, and provides glucose predictions. The predictions are fed to the NMPC, in order for the latter to estimate the optimum insulin infusion rates. An algorithm based on fuzzy logic has been developed for the on-line adaptation of the NMPC control parameters. The IIAS has been in silico evaluated using an appropriate simulation environment (UVa T1DM simulator). The IIAS was able to handle various meal profiles, fasting conditions, interpatient variability, intraday variation in physiological parameters, and errors in meal amount estimations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study validated the accuracy of data from a self-reported questionnaire on smoking behaviour with the use of exhaled carbon monoxide (CO) level measurements in two groups of patients. Group 1 included patients referred to an oral medicine unit, whereas group 2 was recruited from the daily outpatient service. All patients filled in a standardized questionnaire regarding their current and former smoking habits. Additionally, exhaled CO levels were measured using a monitor. A total of 121 patients were included in group 1, and 116 patients were included in group 2. The mean value of exhaled CO was 7.6 ppm in the first group and 9.2 ppm in the second group. The mean CO values did not statistically significantly differ between the two groups. The two exhaled CO level measurements taken for each patient exhibited very good correlation (Spearman's coefficient of 0.9857). Smokers had a mean difference of exhaled CO values of 13.95 ppm (p < 0.001) compared to non-smokers adjusted for the first or second group. The consumption of one additional pack year resulted in an increase in CO values of 0.16 ppm (p = 0.003). The consumption of one additional cigarette per day elevated the CO measurements by 0.88 ppm (p < 0.001). Based on these results, the correlations between the self-reported smoking habits and exhaled CO values are robust and highly reproducible. CO monitors may offer a non-invasive method to objectively assess current smoking behaviour and to monitor tobacco use cessation attempts in the dental setting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Hypnotic depth but not haemodynamic response to painful stimulation can be measured with various EEG-based anaesthesia monitors. We evaluated the variation of pulse plethysmography amplitude induced by an electrical tetanic stimulus (PPG variation) as a potential measure for analgesia and predictor of haemodynamic responsiveness during general anaesthesia. METHODS: Ninety-five patients, ASA I or II, were randomly assigned to five groups [Group 1: bispectral index (BIS) (range) 40-50, effect site remifentanil concentration 1 ng ml(-1);Group 2: BIS 40-50, remifentanil 2 ng ml(-1); Group 3: BIS 40-50, remifentanil 4 ng ml(-1); Group 4: BIS 25-35, remifentanil 2 ng ml(-1); Group 5: BIS 55-65, remifentanil 2 ng ml(-1)]. A 60 mA tetanic stimulus was applied for 5 s on the ulnar nerve. From the digitized pulse oximeter wave recorded on a laptop computer, linear and non-linear parameters of PPG variation during the 60 s period after stimulation were computed. The haemodynamic response to subsequent orotracheal intubation was recorded. The PPG variation was compared between groups and between responders and non-responders to intubation (anova). Variables independently predicting the response were determined by logistic regression. RESULTS: The probability of a response to tracheal intubation was 0.77, 0.47, 0.05, 0.18 and 0.52 in Groups 1-5, respectively (P<0.03). The PPG variability was significantly higher in responders than in non-responders but it did not improve the prediction of the response to tracheal intubation based on BIS level and effect site remifentanil concentration. CONCLUSION: Tetanic stimulation induced PPG variation does not reflect the analgesic state in a wide clinical range of surgical anaesthesia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The Bispectral Index (BIS) reportedly reflects anesthetic depth. It is recommended that anesthetic agents should be titrated to maintain the BIS between 40 and 60 arbitrary BIS units during anesthesia. For anesthesia providers to follow this recommendation, the monitor should be predictably affected by different anesthetic agents and have good interpatient and intrapatient reproducibility. The authors hypothesized that when two BISxp devices (Aspect Medical Systems, Newton, MA) are placed concurrently on the same patient, their readings are concordant throughout the anesthetic period. METHODS: Simultaneous BIS recordings from two BISxp monitors were obtained during anesthesia at 5-s intervals from 12 participants. RESULTS: In total 22,860 concurrent paired BIS readings were obtained. For 10.7% of the time, there were sustained periods of 30 s or greater where the readings suggested a different depth of anesthesia. For 6% of the time, there were sustained periods of 30 s or greater where the readings differed by 10 or more arbitrary BIS units. The regression coefficient (R) for the two devices was 0.65 (range, 0.35-0.92). There was zero bias between the devices, and the 95% limits of agreement ranged between -18 and +17. CONCLUSION: A conflicting anesthetic management was suggested by the simultaneous BIS readings 10.7% of the time. These results suggest that BISxp does not always provide a reproducible single number. Anesthesia providers should not rely exclusively on the BIS reading when assessing depth of anesthesia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The last two decades have seen intense scientific and regulatory interest in the health effects of particulate matter (PM). Influential epidemiological studies that characterize chronic exposure of individuals rely on monitoring data that are sparse in space and time, so they often assign the same exposure to participants in large geographic areas and across time. We estimate monthly PM during 1988-2002 in a large spatial domain for use in studying health effects in the Nurses' Health Study. We develop a conceptually simple spatio-temporal model that uses a rich set of covariates. The model is used to estimate concentrations of PM10 for the full time period and PM2.5 for a subset of the period. For the earlier part of the period, 1988-1998, few PM2.5 monitors were operating, so we develop a simple extension to the model that represents PM2.5 conditionally on PM10 model predictions. In the epidemiological analysis, model predictions of PM10 are more strongly associated with health effects than when using simpler approaches to estimate exposure. Our modeling approach supports the application in estimating both fine-scale and large-scale spatial heterogeneity and capturing space-time interaction through the use of monthly-varying spatial surfaces. At the same time, the model is computationally feasible, implementable with standard software, and readily understandable to the scientific audience. Despite simplifying assumptions, the model has good predictive performance and uncertainty characterization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Hypnotic depth but not haemodynamic responsiveness is measured with EEG-based monitors. In this study we compared heart rate variability (HRV) in unstimulated patients and stimulation-induced HRV at different levels of anaesthesia. METHODS: A total of 95 ASA I or II patients were randomly assigned to five groups (Group 1: BIS 45(5), remifentanil 1 ng ml(-1); Group 2: BIS 45(5), remifentanil 2 ng ml(-1); Group 3: BIS 45(5), remifentanil 4 ng ml(-1); Group 4: BIS 30(5), remifentanil 2 ng ml(-1); Group 5: BIS 60(5), remifentanil 2 ng ml(-1)). A time- and frequency-domain analysis of the RR interval (RRI) from the electrocardiogram was performed. HRV before induction, before and after a 5 s tetanic stimulus of the ulnar nerve, and before and after tracheal intubation was compared between groups, between stimuli, and between responders to intubation [systolic arterial pressure (SAP) increase >20 mm Hg, a maximal heart rate (HR) after intubation >90 min(-1) or both] and non-responders (anova). RESULTS: Induction of anaesthesia significantly lowered HR and HRV. Mean RRI before stimulation was higher in G3 than in G1, G2, and G4 (P < 0.001), whereas the other HRV parameters were similar. Intubation induced a greater HRV response than tetanic stimulation. The mean RRI after intubation was lower in G3 compared with the other groups and the sd of the RRI after tetanic stimulation was lower in G3 compared with G5. Otherwise, unstimulated HRV and stimulation-induced HRV were similar in responders and non-responders. CONCLUSION: HRV parameters discriminate between awake and general anaesthesia, are different after tracheal intubation and a 5 s ulnar nerve stimulation, but do not discriminate between different levels of haemodynamic responsiveness during surgical anaesthesia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The water spider Argyroneta aquatica (Clerck) is the only spider that spends its whole life under water. Water spiders keep an air bubble around their body for breathing and build under-water air bells, which they use for shelter and raising offspring, digesting and consuming prey, moulting, depositing eggs and sperm, and copulating. It is unclear whether these bells are an important oxygen reservoir for breathing under water, or whether they serve mainly to create water-free space for feeding and reproduction. In this study, we manipulated the composition of the gas inside the bell of female water spiders to test whether they monitor the quality of this gas, and replenish oxygen if required. We exchanged the entire gas in the bell either with pure O(2), pure CO(2), or with ambient air as control, and monitored behavioural responses. The test spiders surfaced and replenished air more often in the CO(2) treatment than in the O(2) treatment, and they increased bell building behaviour. In addition to active oxygen regulation, they monitored and adjusted the bells by adding silk. These results show that water spiders use the air bell as an oxygen reservoir, and that it functions as an external lung, which renders it essential for living under water permanently. A. aquatica is the only animal that collects, transports, and stores air, and monitors its property for breathing, which is an adaptive response of a terrestrial animal to the colonization of an aquatic habitat. J. Exp. Zool. 307A:549-555, 2007. (c) 2007 Wiley-Liss, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fluid optimization is a major contributor to improved outcome in patients. Unfortunately, anesthesiologists are often in doubt whether an additional fluid bolus will improve the hemodynamics of the patient or not as excess fluid may even jeopardize the condition. This article discusses physiological concepts of liberal versus restrictive fluid management followed by a discussion on the respective capabilities of various monitors to predict fluid responsiveness. The parameter difference in pulse pressure (dPP), derived from heart-lung interaction in mechanically ventilated patients is discussed in detail. The dPP cutoff value of 13% to predict fluid responsiveness is presented together with several assessment techniques of dPP. Finally, confounding variables on dPP measurements, such as ventilation parameters, pneumoperitoneum and use of norepinephrine are also mentioned.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: We studied intra-individual and inter-individual variability of two online sedation monitors, BIS and Entropy, in volunteers under sedation. METHODS: Ten healthy volunteers were sedated in a stepwise manner with doses of either midazolam and remifentanil or dexmedetomidine and remifentanil. One week later the procedure was repeated with the remaining drug combination. The doses were adjusted to achieve three different sedation levels (Ramsay Scores 2, 3 and 4) and controlled by a computer-driven drug-delivery system to maintain stable plasma concentrations of the drugs. At each level of sedation, BIS and Entropy (response entropy and state entropy) values were recorded for 20 minutes. Baseline recordings were obtained before the sedative medications were administered. RESULTS: Both inter-individual and intra-individual variability increased as the sedation level deepened. Entropy values showed greater variability than BIS(R) values, and the variability was greater during dexmedetomidine/remifentanil sedation than during midazolam/remifentanil sedation. CONCLUSIONS: The large intra-individual and inter-individual variability of BIS and Entropy values in sedated volunteers makes the determination of sedation levels by processed electroencephalogram (EEG) variables impossible. Reports in the literature which draw conclusions based on processed EEG variables obtained from sedated intensive care unit (ICU) patients may be inaccurate due to this variability. TRIAL REGISTRATION: clinicaltrials.gov Nr. NCT00641563.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to compare the validity and output of the biaxial ActiGraph GT1M and the triaxial GT3X (ActiGraph, LLC, Pensacola, FL, USA)accelerometer in 5- to 9-year-old children. Thirty-two children wore the two monitors while their energy expenditure was measured with indirect calorimetry. They performed four locomotor and four play activities in an exercise laboratory and were further measured during 12 minutes of a sports lesson. Validity evidence in relation to indirect calorimetry was examined with linear regression equations applied to the laboratory data. During the sports lessons predicted energy expenditure according to the regression equations was compared to measured energy expenditure with the Wilcoxon-signed rank test and the Spearman correlation. To compare the output, agreement between counts of the two monitors during the laboratory activities was assessed with Bland-Altman plots. The evidence of validity was similar for both monitors. Agreement between the output of the two monitors was good for vertical counts (mean bias = −14 ± 22 counts) but not for horizontal counts (−17 ± 32 counts). The current results indicate that the two accelerometer models are able to estimate energy expenditure of a range of physical activities equally well in young children. However, they show output differences for movement in the horizontal direction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With an increasing number of institutions offering proton therapy, the number of multi-institutional clinical trials involving proton therapy will also increase in the coming years. The Radiological Physics Center monitors sites involved in clinical trials through the use of site visits and remote auditing with thermoluminescent dosimeters (TLD) and mailable anthropomorphic phantoms. Currently, there are no heterogeneous phantoms that have been commissioned to evaluate proton therapy. It was hypothesized that an anthropomorphic pelvis phantom can be designed to audit treatment procedures (patient simulation, treatment planning and treatment delivery) at proton facilities to confirm agreement between the measured dose and calculated dose within 5%/3mm with a reproducibility of 3%. A pelvis phantom originally designed for use with photon treatments was retrofitted for use in proton therapy. The relative stopping power (SP) of each phantom material was measured. Hounsfield Units (HU) for each phantom material were measured with a CT scanner and compared to the relative stopping power calibration curve. The tissue equivalency for each material was calculated. Two proton treatment plans were created; one which did not correct for material SP differences (Plan 1) and one plan which did correct for SP differences (Plan 2). Film and TLD were loaded into the phantom and the phantom was irradiated 3 times per plan. The measured values were compared to the HU-SP calibration curve and it was found that the stopping powers for the materials could be underestimated by 5-10%. Plan 1 passed the criteria for the TLD and film margins with reproducibility under 3% between the 3 trials. Plan 2 failed because the right-left film dose profile average displacement was -9.0 mm on the left side and 6.0 mm on the right side. Plan 2 was intended to improve the agreements and instead introduced large displacements along the path of the beam. Plan 2 more closely represented the actual phantom composition with corrected stopping powers and should have shown an agreement between the measured and calculated dose within 5%/3mm. The hypothesis was rejected and the pelvis phantom was found to be not suitable to evaluate proton therapy treatment procedures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Increasingly, families referred for Intensive Family Preservation Services have not experienced a crisis of maltreatment, focused on the parent; rather these families have children with chronic behavioral difficulties for which their parents lack the skills to cope. These are the same families whose children were formerly placed in residential programs. This paper presents The Family Partners Credit Card System, incorporating behavioral techniques developed to treat children in out-of-home placements into a family preservation model. Two case examples illustrate how the system has been modified to train biological or adoptive parents in parenting skills, enable them to teach their children pro-family behaviors, and reinforce new behaviors through a credit card that monitors an ongoing balance of credits and fines.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The clinical demand for a device to monitor Blood Pressure (BP) in ambulatory scenarios with minimal use of inflation cuffs is increasing. Based on the so-called Pulse Wave Velocity (PWV) principle, this paper introduces and evaluates a novel concept of BP monitor that can be fully integrated within a chest sensor. After a preliminary calibration, the sensor provides non-occlusive beat-by-beat estimations of Mean Arterial Pressure (MAP) by measuring the Pulse Transit Time (PTT) of arterial pressure pulses travelling from the ascending aorta towards the subcutaneous vasculature of the chest. In a cohort of 15 healthy male subjects, a total of 462 simultaneous readings consisting of reference MAP and chest PTT were acquired. Each subject was recorded at three different days: D, D+3 and D+14. Overall, the implemented protocol induced MAP values to range from 80 ± 6 mmHg in baseline, to 107 ± 9 mmHg during isometric handgrip maneuvers. Agreement between reference and chest-sensor MAP values was tested by using intraclass correlation coefficient (ICC = 0.78) and Bland-Altman analysis (mean error = 0.7 mmHg, standard deviation = 5.1 mmHg). The cumulative percentage of MAP values provided by the chest sensor falling within a range of ±5 mmHg compared to reference MAP readings was of 70%, within ±10 mmHg was of 91%, and within ±15mmHg was of 98%. These results point at the fact that the chest sensor complies with the British Hypertension Society (BHS) requirements of Grade A BP monitors, when applied to MAP readings. Grade A performance was maintained even two weeks after having performed the initial subject-dependent calibration. In conclusion, this paper introduces a sensor and a calibration strategy to perform MAP measurements at the chest. The encouraging performance of the presented technique paves the way towards an ambulatory-compliant, continuous and non-occlusive BP monitoring system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cerebral electrical activity is highly nonstationary because the brain reacts to ever changing external stimuli and continuously monitors internal control circuits. However, a large amount of energy is spent to maintain remarkably stationary activity patterns and functional inter-relations between different brain regions. Here we examine linear EEG correlations in the peri-ictal transition of focal onset seizures, which are typically understood to be manifestations of dramatically changing inter-relations. Contrary to expectations we find stable correlation patterns with a high similarity across different patients and different frequency bands. This skeleton of spatial correlations may be interpreted as a signature of standing waves of electrical brain activity constituting a dynamical ground state. Such a state could promote the formation of spatiotemporal neuronal assemblies and may be important for the integration of information stemming from different local circuits of the functional brain network.