967 resultados para MESENTERIC-ARTERY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE. The purpose of this study was to evaluate the prevalence of mesenteric venous thrombosis (MVT) in the Swiss Inflammatory Bowel Disease Cohort Study and to correlate MVT with clinical outcome. MATERIALS AND METHODS. Abdominal portal phase CT was used to examine patients with inflammatory bowel disease (IBD). Two experienced abdominal radiologists retrospectively analyzed the images, focusing on the superior and inferior mesenteric vein branches and looking for signs of acute or chronic thrombosis. The location of abnormalities was registered. The presence of MVT was correlated with IBD-related radiologic signs and complications. RESULTS. The cases of 160 patients with IBD (89 women, 71 men; Crohn disease [CD], 121 patients; ulcerative colitis [UC], 39 patients; median age at diagnosis, 27 years for patients with CD, 32 years for patients with UC) were analyzed. MVT was detected in 43 patients with IBD (26.8%). One of these patients had acute MVT; 38, chronic MVT; and four, both. The prevalence of MVT did not differ between CD (35/121 [28.9%]) and UC (8/39 [20.5%]) (p = 0.303). The location of thrombosis was different between CD and UC (CD, jejunal or ileal veins only [p = 0.005]; UC, rectocolic veins only [p = 0.001]). Almost all (41/43) cases of thrombosis were peripheral. MVT in CD patients was more frequently associated with bowel wall thickening (p = 0.013), mesenteric fat hypertrophy (p = 0.005), ascites (p = 0.002), and mesenteric lymph node enlargement (p = 0.036) and was associated with higher rate of bowel stenosis (p < 0.001) and more intestinal IBD-related surgery (p = 0.016) in the outcome. Statistical analyses for patients with UC were not relevant because of the limited population (n = 8). CONCLUSION. MVT is frequently found in patients with IBD. Among patients with CD, MVT is associated with bowel stenosis and CD-related intestinal surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a case of a 71-year-old man with a long coronary artery disease history and two sets of coronary artery bypass grafts. He developed large aortocoronary saphenous vein graft aneurysms in the two grafts from the first set of aortocoronary saphenous venous 20 years later. During the previous 3 years, the aneurysms grew in diameter from 22 to 50 mm. Because of severe renal insufficiency, and in order to avoid jeopardizing the late normal coronary artery bypass grafts by further thoracic surgery, we excluded successfully these altered grafts percutaneously by using 13 coils during the same procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: Estimates of the left ventricular ejection fraction (LVEF) in patients with life-threatening ventricular arrhythmias related to coronary artery disease (CAD) have rarely been reported despite it has become the basis for determining patient's eligibility for prophylactic defibrillator. We aimed to determine the extent and distribution of reduced LVEF in patients with sustained ventricular tachycardia or ventricular fibrillation. METHODS AND RESULTS: 252 patients admitted for ventricular arrhythmia related to CAD were included: 149 had acute myocardial infarction (MI) (Group I, 59%), 54 had significant chronic obstructive CAD suggestive of an ischaemic arrhythmic trigger (Group II, 21%) and 49 patients had an old MI without residual ischaemia (Group III, 19%). 34% of the patients with scar-related arrhythmias had an LVEF > or =40%. Based on pre-event LVEF evaluation, it can be estimated that less than one quarter of the whole study population had a known chronic MI with severely reduced LVEF. In Group III, the proportion of inferior MI was significantly higher than anterior MI (81 vs. 19%; absolute difference, -62; 95% confidence interval, -45 to -79; P < or = 0.0001), though median LVEF was higher in inferior MI (0.37 +/- 10 vs. 0.29 +/- 10; P = 0.0499). CONCLUSION: Patients included in defibrillator trials represent only a minority of the patients at risk of sudden cardiac death. By applying the current risk stratification strategy based on LVEF, more than one third of the patients with old MI would not have qualified for a prophylactic defibrillator. Our study also suggests that inferior scars may be more prone to ventricular arrhythmia compared to anterior scars.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to evaluate the prevalence of mesenteric venous thrombosis (MVT) in the Swiss Inflammatory Bowel Disease Cohort Study and to correlate MVT with clinical outcome. MATERIALS AND METHODS: Abdominal portal phase CT was used to examine patients with inflammatory bowel disease (IBD). Two experienced abdominal radiologists retrospectively analyzed the images, focusing on the superior and inferior mesenteric vein branches and looking for signs of acute or chronic thrombosis. The location of abnormalities was registered. The presence of MVT was correlated with IBD-related radiologic signs and complications. RESULTS: The cases of 160 patients with IBD (89 women, 71 men; Crohn disease [CD], 121 patients; ulcerative colitis [UC], 39 patients; median age at diagnosis, 27 years for patients with CD, 32 years for patients with UC) were analyzed. MVT was detected in 43 patients with IBD (26.8%). One of these patients had acute MVT; 38, chronic MVT; and four, both. The prevalence of MVT did not differ between CD (35/121 [28.9%]) and UC (8/39 [20.5%]) (p = 0.303). The location of thrombosis was different between CD and UC (CD, jejunal or ileal veins only [p = 0.005]; UC, rectocolic veins only [p = 0.001]). Almost all (41/43) cases of thrombosis were peripheral. MVT in CD patients was more frequently associated with bowel wall thickening (p = 0.013), mesenteric fat hypertrophy (p = 0.005), ascites (p = 0.002), and mesenteric lymph node enlargement (p = 0.036) and was associated with higher rate of bowel stenosis (p < 0.001) and more intestinal IBD-related surgery (p = 0.016) in the outcome. Statistical analyses for patients with UC were not relevant because of the limited population (n = 8). CONCLUSION: MVT is frequently found in patients with IBD. Among patients with CD, MVT is associated with bowel stenosis and CD-related intestinal surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A cardiac-triggered free-breathing three-dimensional (3D) balanced fast field-echo projection renal magnetic resonance (MR) angiographic sequence was investigated for in-stent lumen visualization of a dedicated metallic renal artery stent. Fourteen prototype stents were deployed in the renal arteries of six pigs (in two pigs, three stents were deployed). Projection renal MR angiography was compared with standard contrast material-enhanced 3D breath-hold MR angiography. Artifact-free in-stent lumen visualization was achieved with both projection MR angiography and contrast-enhanced MR angiography. These promising results warrant further studies for visualization of in-stent restenosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report an unusual case of congenital giant coronary aneurysm. A 23 year-old male with a history of acute myocardial infarction presented an abnormal shadow in the left cardiac border on routine X-ray. Electrocardiogram and physical examination were normal without any clinical signs of inflammation, but computed tomography (CT) scan and cardiac magnetic resonance imaging (MRI) revealed a giant (>50mm) coronary aneurysm. Coronary artery bypass grafting (CABG) with coronary artery aneurysm (CAA) resection resolved the CAA. Coronary artery aneurysms are entities of localised dilation and can be common events in chronic infectious disease as a result of the systemic inflammatory state; however, giant coronary aneurysms (measuring more than 50mm) are rare. This is especially true where the pathological aetiology was not clearly defined or was believed to be of congenital origin. To date only a few published case reports exist for this type of pathological entity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: According to recent guidelines, patients with coronary artery disease (CAD) should undergo revascularization if significant myocardial ischemia is present. Both, cardiovascular magnetic resonance (CMR) and fractional flow reserve (FFR) allow for a reliable ischemia assessment and in combination with anatomical information provided by invasive coronary angiography (CXA), such a work-up sets the basis for a decision to revascularize or not. The cost-effectiveness ratio of these two strategies is compared. METHODS: Strategy 1) CMR to assess ischemia followed by CXA in ischemia-positive patients (CMR + CXA), Strategy 2) CXA followed by FFR in angiographically positive stenoses (CXA + FFR). The costs, evaluated from the third party payer perspective in Switzerland, Germany, the United Kingdom (UK), and the United States (US), included public prices of the different outpatient procedures and costs induced by procedural complications and by diagnostic errors. The effectiveness criterion was the correct identification of hemodynamically significant coronary lesion(s) (= significant CAD) complemented by full anatomical information. Test performances were derived from the published literature. Cost-effectiveness ratios for both strategies were compared for hypothetical cohorts with different pretest likelihood of significant CAD. RESULTS: CMR + CXA and CXA + FFR were equally cost-effective at a pretest likelihood of CAD of 62% in Switzerland, 65% in Germany, 83% in the UK, and 82% in the US with costs of CHF 5'794, euro 1'517, £ 2'680, and $ 2'179 per patient correctly diagnosed. Below these thresholds, CMR + CXA showed lower costs per patient correctly diagnosed than CXA + FFR. CONCLUSIONS: The CMR + CXA strategy is more cost-effective than CXA + FFR below a CAD prevalence of 62%, 65%, 83%, and 82% for the Swiss, the German, the UK, and the US health care systems, respectively. These findings may help to optimize resource utilization in the diagnosis of CAD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional ultrasonography highly contributes to a non invasive diagnosis of HS schistosomiasis (Cerri et al., 1984). The introduction of Dopple allowed new advances in the knowledge of the portal dinamics of this disease (Taylor et al., 1985; Moriyasu et al., 1986). The aim of this paper was to analize the hemodinamic behavior of the portal vessels, considering caliper, maximum flow speed, direction of flow and preferential disposition of the collateral vessels. Thirty two patients with schistosomiasis mansoni with confirmed hepatosplenic form (HSSM), were analyzed. Fourteen patients with the intestinal form, have been analyzed as a control group. The results demonstrated that the maximum speed of the portal vein in the two groups has not been significantly diferent. Nevertheless, the diameter of the PV in the hepatosplenic group has been larger. The splenic vein presented speed and caliper larger than the superior mesenteric vein. The hepatic artery has been detectly in only 40% of the cases. The hepatic veins presented normal caliper and spectral pattern. The duplex proved to be an useful technich complementar and non-invasive, in the study of the HSSM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 35-year-old drug addict was found dead in a public toilet with a ruptured groin, which was later diagnosed to be a leaking pseudo-aneurysm. Investigation at the scene revealed impressive external hemorrhage related to a groin wound. Post-mortem computed tomography angiography demonstrated an aneurysm of the right femoral artery with leak of contrast liquid. Signs of blood loss were evident at autopsy, and histological examination revealed necrosis and rupture of the pseudo-aneurysm. Toxicological analyses were positive for methadone, cocaine, citalopram, and benzodiazepines. This is the first case report in the literature of a ruptured femoral pseudo-aneurysm with a post-mortem radiological diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The presence of intravascular foreign bodies is underreported in the literature and is more commonly encountered in clinical practice. We report on a case where an attempt to position a carotid stent resulted in misdeployment of the stent in the femoral artery and its surgical removal. METHODS: A 63-year-old patient admitted to hospital for cerebral stroke underwent thrombolysis for occlusive dissection of right carotid artery and was transferred to our hospital for additional thrombo-aspiration and carotid stenting. RESULTS: The carotid stent was misdeployed incompletely in the femoral artery and had to be removed surgically. CONCLUSIONS: Appropriate knowledge of intravascular migration and deployment failure management should be considered as important as the optimal device deployment.