977 resultados para MEAN MAGNETIC-FIELD
Resumo:
Various Green functions of the Dirac equation with a magnetic-solenoid field (the superposition of the Aharonov-Bohm field and a collinear uniform magnetic field) are constructed and studied. The problem is considered in 2+1 and 3+1 dimensions for the natural extension of the Dirac operator (the extension obtained from the solenoid regularization). Representations of the Green functions as proper time integrals are derived. The nonrelativistic limit is considered. For the sake of completeness the Green functions of the Klein-Gordon particles are constructed as well. (C) 2004 American Institute of Physics.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
We report new archeointensity data obtained from the analyses of baked clay elements (architectural and kiln brick fragments) sampled in Southeast Brazil and historically and/or archeologically dated between the end of the XVIth century and the beginning of the XXth century AD. The results were determined using the classical Thellier and Thellier protocol as modified by Coe, including partial thermoremanent magnetization (pTRM) and pTRM-tail checks, and the Triaxe protocol, which involves continuous high-temperature magnetization measurements. In both protocols, TRM anisotropy and cooling rate TRM dependence effects were taken into account for intensity determinations which were successfully performed for 150 specimens from 43 fragments, with a good agreement between intensity results obtained from the two procedures. Nine site-mean intensity values were derived from three to eight fragments and defined with standard deviations of less than 8%. The site-mean values vary from similar to 25 mu T to similar to 42 mu T and describe in Southeast Brazil a continuous decreasing trend by similar to 5 mu T per century between similar to 1600 AD and similar to 1900 AD. Their comparison with recent archeointensity results obtained from Northeast Brazil and reduced at a same latitude shows that: (1) the geocentric axial dipole approximation is not valid between these southeastern and northeastern regions of Brazil, whose latitudes differ by similar to 10 degrees, and (2) the available global geomagnetic field models (gufm1 models, their recalibrated versions and the CALSK3 models) are not sufficiently precise to reliably reproduce the non-dipole field effects which prevailed in Brazil for at least the 1600-1750 period. The large non-dipole contribution thus highlighted is most probably linked to the evolution of the South Atlantic Magnetic Anomaly (SAMA) during that period. Furthermore, although our dataset is limited, the Brazilian archeointensity data appear to support the view of a rather oscillatory behavior of the axial dipole moment during the past three centuries that would have been marked in particular by a moderate increase between the end of the XVIIIth century and the middle of the XIXth century followed by the well-known decrease from 1840 AD attested by direct measurements. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
We find the first nonlinear correction to the field produced by a static charge at rest in a background constant magnetic field. It is quadratic in the charge and purely magnetic. The third-rank polarization tensor-the nonlinear response function-is written within the local approximation of the effective action in an otherwise model-and approximation-independent way within any P-invariant nonlinear electrodynamics, QED included. DOI: 10.1103/PhysRevD.86.125028
Resumo:
This paper completes our study of coherent states in the so-called magnetic-solenoid field (a collinear combination of a constant uniform magnetic field and Aharonov-Bohm solenoid field) presented in Bagrov et al (2010 J. Phys. A: Math. Theor. 43 354016, 2011 J. Phys. A: Math. Theor. 44 055301). Here, we succeeded in proving nontrivial completeness relations for non-relativistic and relativistic coherent states in such a field. In addition, we solve here the relevant Stieltjes moment problem and present a comparative analysis of our coherent states and the well-known, in the case of pure uniform magnetic field, Malkin-Man'ko coherent states.
Resumo:
Further advances in magnetic hyperthermia might be limited by biological constraints, such as using sufficiently low frequencies and low field amplitudes to inhibit harmful eddy currents inside the patient's body. These incite the need to optimize the heating efficiency of the nanoparticles, referred to as the specific absorption rate (SAR). Among the several properties currently under research, one of particular importance is the transition from the linear to the non-linear regime that takes place as the field amplitude is increased, an aspect where the magnetic anisotropy is expected to play a fundamental role. In this paper we investigate the heating properties of cobalt ferrite and maghemite nanoparticles under the influence of a 500 kHz sinusoidal magnetic field with varying amplitude, up to 134 Oe. The particles were characterized by TEM, XRD, FMR and VSM, from which most relevant morphological, structural and magnetic properties were inferred. Both materials have similar size distributions and saturation magnetization, but strikingly different magnetic anisotropies. From magnetic hyperthermia experiments we found that, while at low fields maghemite is the best nanomaterial for hyperthermia applications, above a critical field, close to the transition from the linear to the non-linear regime, cobalt ferrite becomes more efficient. The results were also analyzed with respect to the energy conversion efficiency and compared with dynamic hysteresis simulations. Additional analysis with nickel, zinc and copper-ferrite nanoparticles of similar sizes confirmed the importance of the magnetic anisotropy and the damping factor. Further, the analysis of the characterization parameters suggested core-shell nanostructures, probably due to a surface passivation process during the nanoparticle synthesis. Finally, we discussed the effect of particle-particle interactions and its consequences, in particular regarding discrepancies between estimated parameters and expected theoretical predictions. Copyright 2012 Author(s). This article is distributed under a Creative Commons Attribution 3.0 Unported License. [http://dx.doi. org/10.1063/1.4739533]
Resumo:
AIMS: The objective of the present study was to investigate the relationship between extremely low-frequency magnetic field (ELF-MF) exposure and mortality from several neurodegenerative conditions in Swiss railway employees. METHODS: We studied a cohort of 20,141 Swiss railway employees with 464,129 person-years of follow-up between 1972 and 2002. For each individual, cumulative exposure was calculated from on-site measurements and modelling of past exposure. We compared cause-specific mortality in highly exposed train drivers (mean exposure: 21 microT) with less exposed occupational groups (for example station masters: 1 microT). RESULTS: The hazard ratio for train drivers compared to station masters was 1.96 [95% confidence interval (CI) = 0.98-3.92] for senile dementia and 3.15 (95% CI = 0.90-11.04) for Alzheimer's disease. For every 10 microT years of cumulative exposure senile dementia mortality increased by 5.7% (95% CI = 1.3-10.4), Alzheimer's disease by 9.4% (95% CI = 2.7-16.4) and amyotrophic lateral sclerosis by 2.1% (95% CI = -6.8 to 11.7). There was no evidence for an increase in mortality from Parkinson's disease and multiple sclerosis. CONCLUSIONS: This study suggests a link between exposure to ELF-MF and Alzheimer's disease and indicates that ELF-MF might act in later stages of the disease process.
Resumo:
The goal of this work is to develop a magnetic-based passive and wireless pressure sensor for use in biomedical applications. Structurally, the pressure sensor, referred to as the magneto-harmonic pressure sensor, is composed of two magnetic elements: a magnetically-soft material acts as a sensing element, and a magnetically hard material acts as a biasing element. Both elements are embedded within a rigid sensor body and sealed with an elastomer pressure membrane. Upon excitation of an externally applied AC magnetic field, the sensing element is capable of producing higher-order magnetic signature that is able to be remotely detected with an external receiving coil. When exposed to environment with changing ambient pressure, the elastomer pressure membrane of pressure sensor is deflected depending on the surrounding pressure. The deflection of elastomer membrane changes the separation distance between the sensing and biasing elements. As a result, the higher-order harmonic signal emitted by the magnetically-soft sensing element is shifted, allowing detection of pressure change by determining the extent of the harmonic shifting. The passive and wireless nature of the sensor is enabled with an external excitation and receiving system consisting of an excitation coil and a receiving coil. These unique characteristics made the sensor suitable to be used for continuous and long-term pressure monitoring, particularly useful for biomedical applications which often require frequent surveillance. In this work, abdominal aortic aneurysm is selected as the disease model for evaluation the performance of pressure sensor and system. Animal model, with subcutaneous sensor implantation in mice, was conducted to demonstrate the efficacy and feasibility of pressure sensor in biological environment.
Resumo:
The basalts recovered at Holes 651A and 655B appear to carry a single component remanent magnetization, which is generally of reversed polarity. These magnetizations are consistent with eruption during the Matuyama (651A) and Gilbert (655B) polarity epochs. The blocking temperature spectra and the Js/T curves indicate that titanomaghemite is the principal remanence carrier. The lower mean destructive field (MDF) and higher susceptibility at 651A probably indicates a lower mean oxidation state at this hole relative to 655B, which may simply reflect the age difference between the two basalt sequences. At both holes, a decreasing downcore trend both in natural remanent magnetization (NRM) and susceptibility probably indicates that maghemitization (from primary titanomagnetite) increases downcore. An interval of high coercivity at hole 655B (119.80-151.45 mbsf) appears to define a magnetically distinct unit within the basalt sequence.
Resumo:
During the first section of the "Meteor" cruise No. 2 a profile was run from the Azores to the south across the flanks of the Mid-Atlantic Ridge with a chain of seamounts. The profile extended between the Cruiser (living) and the Hyeres seamounts, which, according to our soundings, form a connected massif, and across the centre of the Grosse Meteor Bank (30°N, 28.5 °W). These seamounts rise from a depth of more than 4000 m up till close to the surface of the sea forming there a large almost flat plateau. In the case of the Grosse Meteor Bank, this plateau has a N-S extension of approx. 30 nautical miles and an E-W extension of approx. 20 nautical miles and reaches a height of 275 m in water depth. The gravity measurements yielded a density of the topographic masses of 2.6 g/cm**3 for the Grosse Meteor Bank. Magnitude and shape of the measured free-air anomaly are very well shown in a model computation with this density. The theoretical gravity effects of the seismically detected swell of cristalline rock and of the Moho depression (mountain root) are not indicated by the observational data. It can, therefore, be assumed that the latter two neutralize each other. It seems, accordingly, that there is no local isostatic compensation of the topographic masses. Hence, the density of 2.6 g/cm**3 obtained would be about the true density of rock. In connection with the mean velocity of P waves (Aric et al., 1968) obtained by seismic refraction methods it must be concluded that the material of the 1200-4000 m thick surface layer of the Grosse Meteor Bank consists of consolidated sediments. This finding is supported by the total intensity of the Earth's magnetic field over the Grosse Meteor Bank. On the assumption of a homogeneous magnetization in the direction of the present Earth's field, the computed anomaly of the massif deviates considerably from the measured anomaly while the magnetic field of the seismically detected crystalline body is capable of interpreting the observed data. Deviating from the prevailing interpretation of the seamounts' plateau as a volcanic cone with submarine abrasion, the Grosse Meteor Bank and the seamounts in the vicinity are assumed to be of continental origin. The questions whether these seamounts submerged later on or whether the sealevel has risen subsequently are, therefore, largely nonexistent.
Resumo:
Intraoral devices for bite-force sensing have several applications in odontology and maxillofacial surgery, as bite-force measurements provide additional information to help understand the characteristics of bruxism disorders and can also be of help for the evaluation of post-surgical evolution and for comparison of alternative treatments. A new system for measuring human bite forces is proposed in this work. This system has future applications for the monitoring of bruxism events and as a complement for its conventional diagnosis. Bruxism is a pathology consisting of grinding or tight clenching of the upper and lower teeth, which leads to several problems such as lesions to the teeth, headaches, orofacial pain and important disorders of the temporomandibular joint. The prototype uses a magnetic field communication scheme similar to low-frequency radio frequency identification (RFID) technology (NFC). The reader generates a low-frequency magnetic field that is used as the information carrier and powers the sensor. The system is notable because it uses an intra-mouth passive sensor and an external interrogator, which remotely records and processes information regarding a patient?s dental activity. This permits a quantitative assessment of bite-force, without requiring intra-mouth batteries, and can provide supplementary information to polysomnographic recordings, current most adequate early diagnostic method, so as to initiate corrective actions before irreversible dental wear appears. In addition to describing the system?s operational principles and the manufacture of personalized prototypes, this report will also demonstrate the feasibility of the system and results from the first in vitro and in vivo trials.
Resumo:
It was recently suggested that the magnetic field created by the current of a bare tether strongly reduces its own electron-collection capability when a magnetic separatrix disconnecting ambient magnetized plasma from tether extends beyond its electric sheath. It is here shown that current reduction by the self-field depends on the ratio meterizing bias and current profiles along the tether (Lt tether length, characteristic length gauging ohmic effects) and on a new dimensionless number Ks involving ambient and tether parameters. Current reduction is weaker the lower Ks and L*/ Lt, which depend critically on the type of cross section: Ks varies as R5/3, h2/3R, and h2/3 1/4 width for wires, round tethers conductive only in a thin layer, and thin tapes, respectively; L* varies as R2/3 for wires and as h2/3 for tapes and round tethers conductive in a layer (R radius, h thickness). Self-field effects are fully negligible for the last two types of cross sections whatever the mode of operation. In practical efficient tether systems having L*/Lt low, maximum current reduction in case of wires is again negligible for power generation; for deorbiting, reduction is <1% for a 10 km tether and 15% for a 20 km tether. In the reboost mode there are no effects for Ks below some threshold; moderate effects may occur in practical but heavy reboost-wire systems that need no dedicated solar power.
Resumo:
It has been recently suggested that the magnetic field created by the current in a bare tether could sensibly reduce its electron collection capability in the magnetised ionosphere, a region of closed magnetic surfaces disconnecting the cylinder from infinity. In this paper, the ohmic voltage drop along the tether is taken into account in considering self-field effects. Separate analyses are carried out for the thrust and power generation and drag modes of operation, which are affected in different ways. In the power generation and drag modes, bias decreases as current increases along the tether, starting at the anodic, positively-biased end (upper end in the usual, eastward-flying spacecraft); in the thrust mode of operation, bias increases as current increases along the tether, starting at the lower end. When the ohmic voltage drop is considered, self-field effects are shown to be weak, in all cases, for tape tethers, and for circular cross-section tethers just conductive in a thin outer layer. Self-field effects might become important, in the drag case only, for tethers with fully conductive cross sections that are unrealistically heavy.
Resumo:
In electric vehicles, passengers sit very close to an electric system of significant power. The high currents achieved in these vehicles mean that the passengers could be exposed to significant magnetic fields. One of the electric devices present in the power train are the batteries. In this paper, a methodology to evaluate the magnetic field created by these batteries is presented. First, the magnetic field generated by a single battery is analyzed using finite elements simulations. Results are compared to laboratory measurements, taken from a real battery, in order to validate the model. After this, the magnetic field created by a complete battery pack is estimated and results are discussed.
Resumo:
Application of a perpendicular magnetic field to charge neutral graphene is expected to result in a variety of broken symmetry phases, including antiferromagnetic, canted, and ferromagnetic. All these phases open a gap in bulk but have very different edge states and noncollinear spin order, recently confirmed experimentally. Here we provide an integrated description of both edge and bulk for the various magnetic phases of graphene Hall bars making use of a noncollinear mean field Hubbard model. Our calculations show that, at the edges, the three types of magnetic order are either enhanced (zigzag) or suppressed (armchair). Interestingly, we find that preformed local moments in zigzag edges interact with the quantum spin Hall like edge states of the ferromagnetic phase and can induce backscattering.