992 resultados para LIVE-ANIMAL ULTRASOUND


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação (mestrado)—Universidade de Brasília, Instituto de Ciências Biológicas, Departamento de Ciências Fisiológicas, Programa de Pós Graduação em Biologia Animal, 2016.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pectus excavatum is the most common congenital deformity of the anterior thoracic wall. The surgical correction of such deformity, using Nuss procedure, consists in the placement of a personalized convex prosthesis into sub-sternal position to correct the deformity. The aim of this work is the CT-scan substitution by ultrasound imaging for the pre-operative diagnosis and pre-modeling of the prosthesis, in order to avoid patient radiation exposure. To accomplish this, ultrasound images are acquired along an axial plane, followed by a rigid registration method to obtain the spatial transformation between subsequent images. These images are overlapped to reconstruct an axial plane equivalent to a CT-slice. A phantom was used to conduct preliminary experiments and the achieved results were compared with the corresponding CT-data, showing that the proposed methodology can be capable to create a valid approximation of the anterior thoracic wall, which can be used to model/bend the prosthesis

Relevância:

20.00% 20.00%

Publicador:

Resumo:

While fluoroscopy is still the most widely used imaging modality to guide cardiac interventions, the fusion of pre-operative Magnetic Resonance Imaging (MRI) with real-time intra-operative ultrasound (US) is rapidly gaining clinical acceptance as a viable, radiation-free alternative. In order to improve the detection of the left ventricular (LV) surface in 4D ultrasound, we propose to take advantage of the pre-operative MRI scans to extract a realistic geometrical model representing the patients cardiac anatomy. This could serve as prior information in the interventional setting, allowing to increase the accuracy of the anatomy extraction step in US data. We have made use of a real-time 3D segmentation framework used in the recent past to solve the LV segmentation problem in MR and US data independently and we take advantage of this common link to introduce the prior information as a soft penalty term in the ultrasound segmentation algorithm. We tested the proposed algorithm in a clinical dataset of 38 patients undergoing both MR and US scans. The introduction of the personalized shape prior improves the accuracy and robustness of the LV segmentation, as supported by the error reduction when compared to core lab manual segmentation of the same US sequences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Kidney stone is a major universal health problem, affecting 10% of the population worldwide. Percutaneous nephrolithotomy is a first-line and established procedure for disintegration and removal of renal stones. Its surgical success depends on the precise needle puncture of renal calyces, which remains the most challenging task for surgeons. This work describes and tests a new ultrasound based system to alert the surgeon when undesirable anatomical structures are in between the puncture path defined through a tracked needle. Methods: Two circular ultrasound transducers were built with a single 3.3-MHz piezoelectric ceramic PZT SN8, 25.4 mm of radius and resin-epoxy matching and backing layers. One matching layer was designed with a concave curvature to work as an acoustic lens with long focusing. The A-scan signals were filtered and processed to automatically detect reflected echoes. Results: The transducers were mapped in water tank and tested in a study involving 45 phantoms. Each phantom mimics different needle insertion trajectories with a percutaneous path length between 80 and 150 mm. Results showed that the beam cross-sectional area oscillates around the ceramics radius and it was possible to automatically detect echo signals in phantoms with length higher than 80 mm. Conclusions: This new solution may alert the surgeon about anatomical tissues changes during needle insertion, which may decrease the need of X-Ray radiation exposure and ultrasound image evaluation during percutaneous puncture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: An accurate percutaneous puncture is essential for disintegration and removal of renal stones. Although this procedure has proven to be safe, some organs surrounding the renal target might be accidentally perforated. This work describes a new intraoperative framework where tracked surgical tools are superimposed within 4D ultrasound imaging for security assessment of the percutaneous puncture trajectory (PPT). Methods: A PPT is first generated from the skin puncture site towards an anatomical target, using the information retrieved by electromagnetic motion tracking sensors coupled to surgical tools. Then, 2D ultrasound images acquired with a tracked probe are used to reconstruct a 4D ultrasound around the PPT under GPU processing. Volume hole-filling was performed in different processing time intervals by a tri-linear interpolation method. At spaced time intervals, the volume of the anatomical structures was segmented to ascertain if any vital structure is in between PPT and might compromise the surgical success. To enhance the volume visualization of the reconstructed structures, different render transfer functions were used. Results: Real-time US volume reconstruction and rendering with more than 25 frames/s was only possible when rendering only three orthogonal slice views. When using the whole reconstructed volume one achieved 8-15 frames/s. 3 frames/s were reached when one introduce the segmentation and detection if some structure intersected the PPT. Conclusions: The proposed framework creates a virtual and intuitive platform that can be used to identify and validate a PPT to safely and accurately perform the puncture in percutaneous nephrolithotomy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foi realizado estudo sobre adequação de consumo de proteínas de alto valor biológico e seu relacionamento com preço e com renda familiar, em diferentes épocas. A diminuição de consumo de origem animal observada, foi causada, por uma modificação na distribuição orçamentária, na qual, a fração destinada à aquisição de carne, leite e ovos, em 1975, foi menor do que em 1969. O ''índice de Consumo de Proteínas de Origem Animal - ICPA", avaliado através da razão entre renda familiar e custo dos alimentos de origem animal recomendados para a família, é indicador eficiente do consumo desses alimentos e indiretamente do estado nutricional. Para sua utilização é necessária a fixação de um ICPA crítico, que permita identificar as famílias quanto à capacidade econômica, uma vez que a fração destinada a compra de alimentos de origem animal varia no decorrer do tempo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To identify risk factors for low birth weight (LBW) among live births by vaginal delivery and to determine if the disappearance of the association between LBW and socioeconomic factors was due to confounding by cesarean section. METHODS: Data were obtained from two population-based cohorts of singleton live births in Ribeirão Preto, Southeastern Brazil. The first one comprised 4,698 newborns from June 1978 to May 1979 and the second included 1,399 infants born from May to August 1994. The risks for LBW were tested in a logistic model, including the interaction of the year of survey and all independent variables under analysis. RESULTS: The incidence of LBW among vaginal deliveries increased from 7.8% in 1978--79 to 10% in 1994. The risk was higher for: female or preterm infants; newborns of non-cohabiting mothers; newborns whose mothers had fewer prenatal visits or few years of education; first-born infants; and those who had smoking mothers. The interaction of the year of survey with gestational age indicated that the risk of LBW among preterm infants fell from 17.75 to 8.71 in 15 years. The mean birth weight decreased more significantly among newborns from qualified families, who also had the highest increase in preterm birth and non-cohabitation. CONCLUSIONS: LBW among vaginal deliveries increased mainly due to a rise in the proportion of preterm births and non-cohabiting mothers. The association between cesarean section and LBW tended to cover up socioeconomic differences in the likelihood of LBW. When vaginal deliveries were analyzed independently, these socioeconomic differences come up again.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rapid growth in genetics and molecular biology combined with the development of techniques for genetically engineering small animals has led to increased interest in in vivo small animal imaging. Small animal imaging has been applied frequently to the imaging of small animals (mice and rats), which are ubiquitous in modeling human diseases and testing treatments. The use of PET in small animals allows the use of subjects as their own control, reducing the interanimal variability. This allows performing longitudinal studies on the same animal and improves the accuracy of biological models. However, small animal PET still suffers from several limitations. The amounts of radiotracers needed, limited scanner sensitivity, image resolution and image quantification issues, all could clearly benefit from additional research. Because nuclear medicine imaging deals with radioactive decay, the emission of radiation energy through photons and particles alongside with the detection of these quanta and particles in different materials make Monte Carlo method an important simulation tool in both nuclear medicine research and clinical practice. In order to optimize the quantitative use of PET in clinical practice, data- and image-processing methods are also a field of intense interest and development. The evaluation of such methods often relies on the use of simulated data and images since these offer control of the ground truth. Monte Carlo simulations are widely used for PET simulation since they take into account all the random processes involved in PET imaging, from the emission of the positron to the detection of the photons by the detectors. Simulation techniques have become an importance and indispensable complement to a wide range of problems that could not be addressed by experimental or analytical approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A descriptive study was developed in order to assess air contamination caused by fungi and particles in seven poultry units. Twenty seven air samples of 25 litters were collected through impaction method. Air sampling and particle concentration measurement were performed in the pavilions’ interior and also outside premises, since this was the place regarded as reference. Simultaneously, temperature and relative humidity were also registered. Regarding fungal load in the air from the seven poultry farms, the highest value obtained was 24040 CFU/m3 and the lowest was 320 CFU/m3. Twenty eight species/genera of fungi were identified, being Scopulariopsis brevicaulis (39.0%) the most commonly isolated species and Rhizopus sp. (30.0%) the most commonly isolated genus. From the Aspergillus genus, Aspergillus flavus (74.5%) was the most frequently detected species. There was a significant correlation (r=0.487; p=0.014) between temperature and the level of fungal contamination (CFU/m3). Considering contamination caused by particles, in this study, particles with larger dimensions (PM5.0 and PM10) have higher concentrations. There was also a significant correlation between relative humidity and concentration of smaller particles namely, PM0.5 (r=0.438; p=0.025) and PM1.0 (r=0.537; p=0.005). Characterizing typical exposure levels to these contaminants in this specific occupational setting is required to allow a more detailed risk assessment analysis and to set exposure limits to protect workers’ health.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada à Escola Superior de Comunicação Social para obtenção de grau de mestre em Publicidade e Marketing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Faz-se nesta dissertação a análise do movimento humano utilizando sinais de ultrassons refletidos pelos diversos membros do corpo humano, designados por assinaturas de ultrassons. Estas assinaturas são confrontadas com os sinais gerados pelo contato dos membros inferiores do ser humano com o chão, recolhidos de forma passiva. O método seguido teve por base o estudo das assinaturas de Doppler e micro-Doppler. Estas assinaturas são obtidas através do processamento dos ecos de ultrassons recolhidos, com recurso à Short-Time Fourier Transform e apresentadas sobre a forma de espectrograma, onde se podem identificar os desvios de frequência causados pelo movimento das diferentes partes do corpo humano. É proposto um algoritmo inovador que, embora possua algumas limitações, é capaz de isolar e extrair de forma automática algumas das curvas e parâmetros característicos dos membros envolvidos no movimento humano. O algoritmo desenvolvido consegue analisar as assinaturas de micro-Doppler do movimento humano, estimando diversos parâmetros tais como o número de passadas realizadas, a cadência da passada, o comprimento da passada, a velocidade a que o ser humano se desloca e a distância percorrida. Por forma a desenvolver, no futuro, um classificador capaz de distinguir entre humanos e outros animais, são também recolhidas e analisadas assinaturas de ultrassons refletidas por dois animais quadrúpedes, um canino e um equídeo. São ainda estudadas as principais características que permitem classificar o tipo de animal que originou a assinatura de ultrassons. Com este estudo mostra-se ser possível a análise de movimento humano por ultrassons, havendo características nas assinaturas recolhidas que permitem a classificação do movimento como humano ou não humano. Do trabalho desenvolvido resultou ainda uma base de dados de assinaturas de ultrassons de humanos e animais que permitirá suportar trabalho de investigação e desenvolvimento futuro.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Copyright © 2013 Springer Netherlands.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Liver steatosis is a common disease usually associated with social and genetic factors. Early detection and quantification is important since it can evolve to cirrhosis. In this paper, a new computer-aided diagnosis (CAD) system for steatosis classification, in a local and global basis, is presented. Bayes factor is computed from objective ultrasound textural features extracted from the liver parenchyma. The goal is to develop a CAD screening tool, to help in the steatosis detection. Results showed an accuracy of 93.33%, with a sensitivity of 94.59% and specificity of 92.11%, using the Bayes classifier. The proposed CAD system is a suitable graphical display for steatosis classification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Liver steatosis is a common disease usually associated with social and genetic factors. Early detection and quantification is important since it can evolve to cirrhosis. Steatosis is usually a diffuse liver disease, since it is globally affected. However, steatosis can also be focal affecting only some foci difficult to discriminate. In both cases, steatosis is detected by laboratorial analysis and visual inspection of ultrasound images of the hepatic parenchyma. Liver biopsy is the most accurate diagnostic method but its invasive nature suggest the use of other non-invasive methods, while visual inspection of the ultrasound images is subjective and prone to error. In this paper a new Computer Aided Diagnosis (CAD) system for steatosis classification and analysis is presented, where the Bayes Factor, obatined from objective intensity and textural features extracted from US images of the liver, is computed in a local or global basis. The main goal is to provide the physician with an application to make it faster and accurate the diagnosis and quantification of steatosis, namely in a screening approach. The results showed an overall accuracy of 93.54% with a sensibility of 95.83% and 85.71% for normal and steatosis class, respectively. The proposed CAD system seemed suitable as a graphical display for steatosis classification and comparison with some of the most recent works in the literature is also presented.