950 resultados para LIGHT-INDUCED AUTOFLUORESCENCE


Relevância:

40.00% 40.00%

Publicador:

Resumo:

A combined detection system of simultaneous contactless conductometric and fluorescent detection for capillary electrophoresis (CE) has been designed and evaluated. The two processes share a common detection cell. A blue light-emitting diode (LED) was used as the excitation source and an optical fiber was used to collect the emitting fluorescence for fluorescent detection (FD). Inorganic ions, fluorescein isothiocyanate (FITC)-labeled amino acids and small molecule peptides were separated and detected by the combined detector, and the detection limits (LODs) of sub-μ M level were achieved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The classic, non-photochemical blue bottle experiment involves the reaction of methylene blue (MB) with deprotonated glucose, to form a bleached form of the dye, leuco-methylene blue (LMB), and subsequent colour recovery by shaking with air. This reaction is a popular demonstrator of key principles in kinetics and reaction mechanisms. Here it is modified so as to highlight features of homogenous and heterogeneous photoinduced electron transfer (PET) (Pure Appl. Chem., 2007, 79, 293-465) reactions, i.e. blue bottle light experiments. The homogeneous blue bottle light experiment uses methylene blue, MB, as the photo-sensitizer and triethanolamine as the sacrificial electron donor. Visible light irradiation of this system leads to its rapid bleaching, followed by the ready restoration of its original colour upon shaking away from the light source. The heterogeneous blue bottle light experiment uses titania as the photo-sensitizer, MB as a redox indicator and glucose as the sacrificial electron donor. UVA light irradiation of this system leads to the rapid bleaching of the MB and the gradual restoration of its original colour with shaking and standing. The latter 'dark' step can be made facile and more demonstrator-friendly by using platinised titania particles. These two photochemical versions of the blue bottle experiment are used to explore the factors which underpin homogeneous and heterogeneous PET reactions and provide useful demonstrations of homogeneous and heterogeneous photochemistry.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Catasetum fimbriatum plants cultivated in the absence of light exhibit continuous shoot growth leading to the formation of nodes and internodes. On the other hand, when these plants are incubated in the presence of light, shoot longitudinal growth is inhibited and pseudobulbs develop just below the shoot apical meristem. These facts provide evidence of a possible influence of light on mitotic cell division in the shoot apex as well as on pseudobulb initiation. The effects of light and dark on the interruption and/or maintenance of shoot apex mitotic activity and the subsequent formation of pseudobulbs in the sub-meristematic regions were investigated by means of histological and hormonal studies. The interruption of shoot apex development occurred around the 150th d of light incubation and seems to have resulted from the establishment of a strong storage sink in the region of the future pseudobulb, in detriment to the continuous activity of the shoot apical meristem. The reduced total cytokinins/IAA ratio in the apex, mainly due to high levels of IAA, could be a key factor in the interruption of cell divisions. Transfer to the dark brings about the resumption of shoot apex development of plants through the re-entrance of cells in the cell cycle which coincides with a significant increase in the total cytokinins/IAA ratio. (C) 2009 Elsevier GmbH. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background and Objectives: There are some indications that low-level laser therapy (LLLT) may delay the development of skeletal muscle fatigue during high-intensity exercise. There have also been claims that LED cluster probes may be effective for this application however there are differences between LED and laser sources like spot size, spectral width, power output, etc. In this study we wanted to test if light emitting diode therapy (LEDT) can alter muscle performance, fatigue development and biochemical markers for skeletal muscle recovery in an experimental model of biceps humeri muscle contractions. Study Design/Materials and Methods: Ten male professional volleyball players (23.6 [SD +/- 5.6] years old) entered a randomized double-blinded placebo-controlled crossover trial. Active cluster LEDT (69 LEDs with wavelengths 660/850 nm, 10/30 mW, 30 seconds total irradiation time, 41.7J of total energy irradiated) or an identical placebo LEDT was delivered under double-blinded conditions to the middle of biceps humeri muscle immediately before exercise. All subjects performed voluntary biceps humeri contractions with a workload of 75% of their maximal voluntary contraction force (MVC) until exhaustion. Results: Active LEDT increased the number of biceps humeri contractions by 12.9% (38.60 [SD +/- 9.03] vs. 34.20 [SD +/- 8.68], P = 0.021) and extended the elapsed time to perform contractions by 11.6% (P = 0.036) versus placebo. In addition, post-exercise levels of biochemical markers decreased significantly with active LEDT: Blood Lactate (P = 0.042), Creatine Kinase (P = 0.035), and C-Reative Protein levels (P = 0.030), when compared to placebo LEDT. Conclusion: We conclude that this particular procedure and dose of LEDT immediately before exhaustive biceps humeri contractions, causes a slight delay in the development of skeletal muscle fatigue, decreases post-exercise blood lactate levels and inhibits the release of Creatine Kinase and C-Reative Protein. Lasers Surg. Med. 41:572-577, 2009. (C) 2009 Wiley-Liss, Inc.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this research was to evaluate the severity of renal ischemia/reperfusion injury as determined by histology and by laser-induced fluorescence (LIF) with excitation wavelengths of 442 nm and 532 nm. Wistar rats (four groups of six animals) were subjected to left renal warm ischemia for 20, 40, 60 and 80 min followed by 10 min of reperfusion. Autofluorescence was determined before ischemia (control) and then every 5-10 min thereafter. Tissue samples for histology were harvested from the right kidney (control) and from the left kidney after reperfusion. LIF and ischemia time showed a significant correlation (p < 0.0001 and r (2)=0.47, and p=0.006 and r (2)=0.25, respectively, for the excitation wavelengths of 442 nm and 532 nm). Histological scores showed a good correlation with ischemia time (p < 0.0001). The correlations between optical spectroscopy values and histological damage were: LIF at 442 nm p < 0.0001, LIF at 532 nm p=0.001; IFF (peak of back scattered light/LIF) at 442 nm p > 0.05, and IFF at 532 nm p > 0.05. After reperfusion LIF tended to return to preischemic basal levels which occurred in the presence of histological damage. This suggests that factors other than morphological alterations may have a more relevant effect on changes observed in LIF. In conclusion, renal ischemia/reperfusion changed tissue fluorescence induced by laser. The excitation light of 442 nm showed a better correlation with the ischemia time and with the severity of tissue injury.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background and Objective: Mucositis is the most common oral complication of cancer chemotherapy, which causes pain on mastication and swallowing, impairs patients` ability to eat and take oral drugs and may determine interruption of the treatment. The aim of this study was to evaluate the effect of light-emitting diode (LED) therapy on chemotherapy-induced mucositis in hamsters. Study Design/Materials and Methods: Animals of both experimental (Group 1; n = 32) and positive control (Group II; n = 32) groups received intraperitoneal injections of 5-fluorouracil on days 0 and 2. All animals had their right and left cheek pouch irritated by superficial scratching on days 3 and 4. In Group I, LED irradiation (630 nm +/- 10 nm, 160 mW, 12 J/cm(2)) was applied during 37.5 seconds at days 3, 4, 6, 8, 10, 12, and 14. In Group II, mucositis was induced, but LED therapy was not performed. The oral mucosa was photographed from day 4 to 14 at 2-day intervals. Photographs were randomly scored according to the severity of induced mucositis (0 to 5). In the negative control group (Group III; n = 6), no mucositis was induced. Biopsies of the cheek pouches of 8 animals (Group I and Group II) were surgically obtained on days 5, 9, 13 and 15 and processed for histological examination. Results: The statistical analysis showed significant differences between irradiated and non-irradiated groups (P < 0.05). However, muscular degeneration was observed in 18% of the samples of Group I. Conclusion: It may be concluded that the LED therapy protocol established for this in vivo study was effective in reducing the severity of oral mucositis, although the oral lesions were not completely prevented. Lasers Surg. Med. 40:625-633, 2008. (c) 2008Wiley-Liss, Inc.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background The clinical efficacy of intense pulsed light (IPL) in the treatment of poikiloderma of Civatte (PC) is well documented, but little is known about microscopic changes. Objective To analyze histopathologic findings on the necks of individuals with PC after IPL therapy. Materials and Methods Fourteen patients with PC on the neck underwent three monthly sessions of IPL. Biopsies and clinical photographs were taken before and 60 similar to days after treatment. A dermatopathologist analyzed histopathologic slides stained with hematoxylin and eosin, Masson's trichrome, Verhoeff-van Gieson and Fontana-Masson or processed for CD-34 immunohistochemistry. The slides also underwent digital image analysis. Clinical results were based on the analysis of the pictures by three dermatologists and on patient satisfaction. Results Intense pulsed light treatment resulted in more-homogeneous melanin distribution; a greater number of fibroblasts and nonfragmented elastic fibers; and greater density (p similar to=similar to.01), color intensity (p similar to=similar to.02), number and thickness of the collagen bundles. No significant changes in vessels number or diameters were observed. Clinical results were positive in 92.9% of the cases. Conclusion IPL treatment of PC induced a more-homogeneous distribution of melanin and increased nonfragmented elastic fibers, collagen density, and intensity. These changes were related to clinical improvement.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Doping tin dioxide (SnO2) with pentavalent Sb5+ ions leads to an enhancement in the electrical conductivity of this material, because Sb5+ substitutes Sn4+ in the matrix, promoting an electronic density increase in the conduction band, due to the donor-like nature of the doping atom. Results of computational simulation, based on the Density Functional Theory (DFT), of SnO2:4%Sb and SnO2:8%Sb show that the bandgap magnitude is strongly affected by the doping concentration, because the energy value found for 4 at%Sb and 8 at%Sb was 3.27 eV and 3.13 eV, respectively, whereas the well known value for undoped SnO2 is about 3.6 eV. Sb-doped SnO2 thin films were obtained by the sol-gel-dip-coating technique. The samples were submitted to excitation with below theoretical bandgap light (450 nm), as well as above bandgap light (266 nm) at low temperature, and a temperature-dependent increase in the conductivity is observed. Besides, an unusual temperature and time dependent decay when the illumination is removed is also observed, where the decay time is slower for higher temperatures. This decay is modeled by considering thermally activated cross section of trapping centers, and the hypothesis of grain boundary scattering as the dominant mechanism for electronic mobility. © 2012 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE To observe changes in fundus autofluorescence 2 years after implantation of blue light-filtering (yellow-tinted) and ultraviolet light-filtering (colorless) intraocular lenses (IOLs). SETTING Department of Ophthalmology and Visual Science, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan, and the Department of Ophthalmology, University of Bern, Bern, Switzerland. DESIGN Prospective comparative observational study. METHODS Patients were enrolled who had cataract surgery with implantation of a yellow-tinted or colorless IOL and for whom images were obtained on which the fundus autofluorescence was measurable using the Heidelberg Retina Angiogram 2 postoperatively. The fundus autofluorescence in the images was classified into 8 abnormal patterns based on the classification of the International Fundus Autofluorescence Classification Group, The presence of normal fundus autofluorescence, geographic atrophy, and wet age-related macular degeneration (AMD) also was recorded. The fundus findings at baseline and 2 years postoperatively were compared. RESULTS Fifty-two eyes with a yellow-tinted IOL and 79 eyes with a colorless IOL were included. Abnormal fundus autofluorescence did not develop or increase in the yellow-tinted IOL group; however, progressive abnormal fundus autofluorescence developed or increased in 12 eyes (15.2%) in the colorless IOL group (P = .0016). New drusen, geographic atrophy, and choroidal neovascularization were observed mainly in the colorless IOL group. The incidence of AMD was statistically significantly higher in the colorless IOL group (P = .042). CONCLUSIONS Two years after cataract surgery, significant differences were seen in the progression of abnormal fundus autofluorescence between the 2 groups. The incidence of AMD was lower in eyes with a yellow-tinted IOL. FINANCIAL DISCLOSURE No author has a financial or proprietary interest in any material or method mentioned.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

CPV receivers are made of materials with very different lineal expansion coefficients. Strong variations in DNI due to the passage of clouds can cause sudden temperature changes that creates mechanical stress. For common solder and metal filled polymers the plastic limit could be reached causing substantial fatigue. The best forecast of receiver reliability is therefore achieved by applying an intermittent light source with nominal irradiance level and a number of cycles equal to the expected cloud passages for a given site. The UPM has developed specialized equipment, dubbed the LYSS (Light cYcling Stressing Source), for carrying out such experiments. The small thermal capacity of receivers allows simulating more than 25000 cycles per week. The number of deep transients expected for Madrid in 30 years operation, based on available data, is about 45000. We are currently using the system to cycle a ?Ge/Ag Epoxy/aluminum? receiver, which shows no degradation after 20000 cycles. The equipment can cast up to 200 and 70 W/cm2 on 0.1 and 1 cm2 cells, respectively.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Chloroplast movement was induced by partial cell illumination using a high-fluence blue microbeam in light-grown and dark-adapted prothallial cells of the fern Adiantum capillus-veneris. Chloroplasts inside the illuminated area moved out (high-fluence response [HFR]), whereas those outside moved toward the irradiated area (low-fluence response [LFR]), although they stopped moving when they reached the border. These results indicate that both HFR and LFR signals are generated by high-fluence blue light of the same area, and that an LFR signal can be transferred long-distance from the beam spot, although an HFR signal cannot. The lifetime of the HFR signal was calculated from the traces of chloroplast movement induced by a brief pulse from a high-fluence blue microbeam to be about 6 min. This is very short compared with that of the LFR (30–40 min; T. Kagawa, M. Wada [1994] J Plant Res 107: 389–398). These data indicate that the signal transduction pathways of the HFR and the LFR must be distinct.