259 resultados para JNI(JavaNativeInterface)
Resumo:
BACKGROUND Cardiac troponin detected by new-generation, highly sensitive assays predicts clinical outcomes among patients with stable coronary artery disease (SCAD) treated medically. The prognostic value of baseline high-sensitivity cardiac troponin T (hs-cTnT) elevation in SCAD patients undergoing elective percutaneous coronary interventions is not well established. This study assessed the association of preprocedural levels of hs-cTnT with 1-year clinical outcomes among SCAD patients undergoing percutaneous coronary intervention. METHODS AND RESULTS Between 2010 and 2014, 6974 consecutive patients were prospectively enrolled in the Bern Percutaneous Coronary Interventions Registry. Among patients with SCAD (n=2029), 527 (26%) had elevated preprocedural hs-cTnT above the upper reference limit of 14 ng/L. The primary end point, mortality within 1 year, occurred in 20 patients (1.4%) with normal hs-cTnT versus 39 patients (7.7%) with elevated baseline hs-cTnT (P<0.001). Patients with elevated hs-cTnT had increased risks of all-cause (hazard ratio 5.73; 95% confidence intervals 3.34-9.83; P<0.001) and cardiac mortality (hazard ratio 4.68; 95% confidence interval 2.12-10.31; P<0.001). Preprocedural hs-TnT elevation remained an independent predictor of 1-year mortality after adjustment for relevant risk factors, including age, sex, and renal failure (adjusted hazard ratio 2.08; 95% confidence interval 1.10-3.92; P=0.024). A graded mortality risk was observed across higher tertiles of elevated preprocedural hs-cTnT, but not among patients with hs-cTnT below the upper reference limit. CONCLUSIONS Preprocedural elevation of hs-cTnT is observed in one fourth of SCAD patients undergoing elective percutaneous coronary intervention. Increased levels of preprocedural hs-cTnT are proportionally related to the risk of death and emerged as independent predictors of all-cause mortality within 1 year. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT02241291.
Resumo:
This paper concerns the application of recent information technologies for creating a software system for numerical simulations in the domain of plasma physics and in particular metal vapor lasers. The presented work is connected with performing modernization of legacy physics software for reuse on the web and inside a Service-Oriented Architecture environment. Applied and described is the creation of Java front-ends of legacy C++ and FORTRAN codes. Then the transformation of some of the scientific components into web services, as well as the creation of a web interface to the legacy application, is presented. The use of the BPEL language for managing scientific workflows is also considered.
Resumo:
The present work aims to allow developers to implement small features on a certain Android application in a fast and easy manner, as well as provide their users to install them ondemand, i.e., they can install the ones they are interested in. These small packages of features are called plugins, and the chosen development language to develop these in was JavaScript. In order to achieve that, an Android framework was developed that enables the host application to install, manage and run these plugins at runtime. This framework was designed to have a very clean and almost readable API, which allowed for better code organization and maintainability. The implementation used the Google’s engine “V8” to interpret the JavaScript code and through a set of JNI calls made that code call certain Android methods previously registered in the runtime. In order to test the framework, it was integrated with the client’s communication application RCS+ using two plugins developed alongside the framework. Although these plugins had only the more common requirements, they were proven to work successfully as intended. Concluding, the framework although successful made it clear that this kind of development through a non-native API has its set of difficulties especially regarding the implementation of complex features.
Resumo:
Antecedentes: El trasplante renal es la mejor alternativa terapéutica para la enfermedad renal crónica terminal. Los medicamentos inmunosupresores previenen el rechazo. El rechazo mediado por anticuerpos es frecuente y disminuye la función y duración del injerto. Objetivo: Evaluar sistemáticamente la evidencia disponible relacionada con la eficacia y seguridad del tratamiento para el rechazo mediado por anticuerpos en pacientes trasplantados renales. Metodologia: Revisión sistemática en bases de datos MEDLINE, EMBASE, Scopus y Biblioteca virtual de la salud. Literatura gris google scholar, google academico, www.clinicaltrialsregister.eu, and https://clinicaltrials.gov/. Búsqueda manual referencias artículos pre-seleccionados así como de revisiones previamente publicadas. Se siguieron las recomendacioes guia PRISMA para la identificacion de artículos potenciales, tamizaje y selección teniendo en cuenta los criterios de inclusion. Extracción datos de acuerdo a las variables, revisión calidad de los artículos elegidos utilizando evaluación riesgo de segos de Cochrane. Resultados: Se seleccionaron 9 ensayos clínicos publicados entre 1980 y 2016, incluyeron 222 pacientes (113 brazo de intervención y 109 en el control), seguimiento promedio 16 meses. Intervenciones evaluadas plasmaféresis, inmunoadsorción y rituximab. Hubo una amplia heterogeneidad en la definición de criterios de inclusión, criterios diagnósticos de rechazo y medidas de evaluación de eficacia de las intervenciones. Tres estudios encontraron diferencias estadísticamente significativas entre los grupos de tratamiento. Conclusiones: La evidencia sobre la eficacia de los tratamientos del rechazo mediado por anticuerpos en injertos renales es de baja calidad. Son necesarios ensayos clínicos controlados para poder definir el tratamiento óptimo de estos pacientes.