750 resultados para Intrasubject repeatability
Resumo:
A fast analytical method for determination of hydroquinone in pharmaceutical formulations employing batch injection analysis (BIA) with amperometric detection using a boron-doped diamond electrode is described. The supporting electrolyte was a 0.1 mol L-1 H2SO4 solution (the single reagent used for analysis). The method showed good repeatability (RSD of 0.45%, n=20), wide linear range (from 10 to 2000 µmol L-1, R=0.9999), low detection limit (0.016 µmol L-1) and satisfactory recovery values (91-96%). Accuracy of the method was evaluated by comparative analyses using high-performance liquid-chromatography. The ability to replace the electronic pipette by disposable syringes (injection procedure) in BIA systems was also shown.
Resumo:
The use and characterization of the first Certified Reference Material (CRM) of Brazilian coal for analytical quality control are presented. All results were determined within the limits of repeatability and reproducibility allowed under the standards. Notable among the characterization parameters was the mineral matter content (45.39%) obtained by an alternative procedure showing a low relative error (-2.1%) compared to the standard technique (low ashing temperature). The possible expanded application of this CRM application in national laboratories, beyond the certificated and reference parameters, has advantages such as lower cost and easy availability, but round robin tests must be performed.
Resumo:
The aim of this work was to develop and validate an analytical method for the quantification of tioconazole in polymeric nanocapsule suspensions by high performance liquid chromatography with UV detection. The analysis was performed with a mobile phase composed of methanol:water (80:20) and 0.18% ammonium hydroxide; RP-18 column and UV detection at 219 nm. The method proved to be linear in the concentration range of 5-50 µg mL-1 (r = 0.9999), specific, precise (repeatability RSD = 1.42%, intermediate precision RSD = 1.17%), accurate (98 - 102%) and robust (RSD < 2.0%). In conclusion, a simple and rapid method was validated proving suitable for quantification of tioconazole in polymeric nanocapsules.
Resumo:
17α-methyltestosterone (17α-MT) is a hormone used in medicine and aquaculture which can be found in natural waters. It is considered an emerging organic pollutant and its accurate and precise analysis is required. Therefore, this study presents the in-house validation of a new voltammetric methodology for 17α-MT analysis in natural waters. A hanging mercury drop electrode and NaOH 5.0×10-3 mol L-1 solution as the electrolyte were employed in the voltammetric determinations. To confirm the presence of 17α-MT in water samples quantitative analysis was performed by ESI-MS/MS. The methodology exhibited good selectivity, linearity, accuracy (recovery of between 100.4 and 108.8%) and precision (RSDs for repeatability of 2.85% and for intermediate precision of 14.10%, with n = 5, respectively). LOD and LOQ were 3.07 µg L-1 and 10.78 µg L-1, respectively. The methodology was suitable for determination of 17α-MT in natural waters due to low-cost, good performance and no sample pre-treatment required.
Resumo:
An evaluation of the pesticides extracted from the soil matrix was conducted using a citrate-buffered solid phase dispersion sample preparation method (QuEChERS). The identification and quantitation of pesticide compounds was performed using gas chromatography-mass spectrometry. Because of the occurrence of the matrix effect in 87% of the analyzed pesticides, the quantification was performed using matrix-matched calibration. The method's quantification limits were between 0.01 and 0.5 mg kg-1. Repeatability and intermediate precision, expressed as a relative standard deviation percentage, were less than 20%. The recoveries in general ranged between 62% and 99%, with a relative standard deviation < 20%. All the responses were linear, with a correlation coefficient (r) ≥0.99.
Resumo:
The chemical treatment evaluation in the field to control post-harvest fruit anthracnose (Colletotrichum gloeosporioides) requires a suitable disease incidence assessment on harvested papaya (Carica papaya) fruits. The minimum number of papaya fruit harvests was determined for valid treatment comparison in field trials for anthracnose chemical control. Repeatability analysis was done using previously published data. The coefficient determination (R²) estimate range, using four methods, and based on means of 12 assessment times, was 92.58 < R² < 94.45%. The number of assessment times required for R²=90% varied from seven to nine. The R² values of 85.1 < R² < 91.3% estimated by ANOVA suggested that any seven successive assessment times were sufficient for treatment comparison.
Resumo:
The goal of this work was to develop a simple and rapid preparation method for patulin analysis in apple juice without previous clean-up. This method combined sonication and liquid extraction techniques and was used for determination of patulin in 37 commercial apple juices available on the market in the South of Brazil. The method performance characteristics were determined using a sample obtained in a local market fortified at five concentration levels of patulin and done in triplicates. The coefficient of variation for repeatability at the fortification level of 20.70µg.L-1 was 3.53 % and the recovery 94.63 %, respectively. The correlation coefficient was 0.9996 and agrees with the requirements for a linear analytical method value. The detection limit was 0.21µg.L-1 and the quantification limit 0.70 µg.L-1. Only three of the analyzed samples were upper the allowed level of 50.00 µg.L-1 recommended for the World Health Organization.
Resumo:
An optode based on thymol blue (TB), an acid-based indicator, has been constructed and evaluated as a detector in FIA system for CO2 determination. The dye was chemically immobilised on the surface of a bifurcated glass optical fibre bundle, using silanisation in organic media. In FIA system, hydrogen carbonate or carbonate samples are injected in a buffer carrier solution, and then are mixed with phosphoric acid solution to generate CO2, which diffuses through a PTFE membrane, in order to be collected in an acceptor carrier fluid, pumped towards to detection cell, in which the optode was adapted. The proposed system presents two linear response ranges, from 1.0 x 10-3 to 1.0 x 10-2 mol l-1, and from 2.0 x 10-2 to 0.10 mol l-1. The sampling frequency was 11 sample h-1, with good repeatability (R.S.D < 4 %, n = 10). In flow conditions the optode lifetime was 170 h. The system was applied in the analysis of commercial mineral water and the results obtained in the hydrogen carbonate determination did not differ significantly from those obtained by potentiometry, at a confidence level of 95 %.
Resumo:
The first objective of this study was to find out reliable laboratory methods to predict the effect of enzymes on specific energy consumption and fiber properties of TMP pulp. The second one was to find with interactive software called “Knowledge discovery in databases” enzymes or other additives that can be used in finding a solution to reduce energy consumption of TMP pulp. The chemical composition of wood and enzymes, which have activity on main wood components were presented in the literature part of the work. The results of previous research in energy reduction of TMP process with enzymes were also highlighted. The main principles of knowledge discovery have been included in literature part too. The experimental part of the work contains the methods description in which the standard size chip, crushed chip and fiberized spruce chip (fiberized pulp) were used. Different types of enzymatic treatment with different dosages and time were tested during the experiments and showed. Pectinase, endoglucanase and mixture of enzymes were used for evaluation of method reliability. The fines content and fiber length of pulp was measured and used as evidence of enzymes' effect. The refining method with “Bauer” laboratory disc refiner was evaluated as not highly reliable. It was not able to provide high repeatability of results, because of uncontrolled feeding capacity and refining consistency. The refining method with Valley refiner did not have a lot of variables and showed stable and repeatable results in energy saving. The results of experiments showed that efficient enzymes impregnation is probably the main target with enzymes application for energy saving. During the work the fiberized pulp showed high accessibility to enzymatic treatment and liquid penetration without special impregnating equipment. The reason was that fiberized pulp has larger wood surface area and thereby the contact area between the enzymatic solution and wood is also larger. Standard size chip and crushed chip treatment without special impregnator of enzymatic solution was evaluated as not efficient and did not show visible, repeatable results in energy consumption decrease. Thereby it was concluded that using of fiberized pulp and Valley refiner for measurements of enzymes' effectiveness in SEC decrease is more suitable than normal size chip and crushed chip with “Bauer” refiner. Endoglucanase with 5 kg/t dosage showed about 20% energy consumption decrease. Mixture of enzymes with 1.5 kg/t dosage showed about 15% decrease of energy consumption during the refining. Pectinase at different dosages and treatment times did not show significant effect on energy consumption. Results of knowledge discovery in databases showed the xylanase, cellulase and pectinase blend as most promising for energy reduction in TMP process. Surfactants were determined as effective additives for energy saving with enzymes.
Resumo:
Local features are used in many computer vision tasks including visual object categorization, content-based image retrieval and object recognition to mention a few. Local features are points, blobs or regions in images that are extracted using a local feature detector. To make use of extracted local features the localized interest points are described using a local feature descriptor. A descriptor histogram vector is a compact representation of an image and can be used for searching and matching images in databases. In this thesis the performance of local feature detectors and descriptors is evaluated for object class detection task. Features are extracted from image samples belonging to several object classes. Matching features are then searched using random image pairs of a same class. The goal of this thesis is to find out what are the best detector and descriptor methods for such task in terms of detector repeatability and descriptor matching rate.
Resumo:
The mechanical properties of aluminium alloys are strongly influenced by the alloying elements and their concentration. In the case of aluminium alloy EN AW-6060 the main alloying elements are magnesium and silicon. The first goal of this thesis was to determine stability, repeatability and sensitivity as figures of merit of the in-situ melt identification technique. In this study the emissions from the laser welding process were monitored with a spectrometer. With the information produced by the spectrometer, quantitative analysis was conducted to determine the figures of merit. The quantitative analysis concentrated on magnesium and aluminium emissions and their relation. The results showed that the stability of absolute intensities was low, but the normalized magnesium emissions were quite stable. The repeatability of monitoring magnesium emissions was high (about 90 %). Sensitivity of the in-situ melt identification technique was also high. As small as 0.5 % change in magnesium content was detected by the spectrometer. The second goal of this study was to determine the loss of mass during deep penetration laser welding. The amount of magnesium in the material was measured before and after laser welding to determine the loss of magnesium. This study was conducted for aluminium alloy with nominal magnesium content of 0-10 % and for standard material EN AW-6060 that was welded with filler wire AlMg5. It was found that while the magnesium concentration in the material changed, the loss of magnesium remained fairly even. Also by feeding filler wire, the behaviour was similar. Thirdly, the reason why silicon had not been detected in the emission spectrum needed to be explained. Literature research showed that the amount of energy required for silicon to excite is considerably higher compared to magnesium. The energy input in the used welding process is insufficient to excite the silicon atoms.
Resumo:
Antimicrobial Resistance in Campylobacter jejuni and Campylobacter coli Campylobacters are a common cause of bacterial gastroenteritis worldwide, with Campylobacter jejuni and C. coli being the most common species isolated in human infections. If antimicrobial treatment is required, the drugs of choice at the moment are the macrolides and fluoroquinolones. In this thesis, the in vitro resistance profiles of the C. jejuni and C. coli strains were evaluated with emphasis on multidrug resistance. The aim was also to evaluate the different resistance mechanisms against the macrolides. Further, the disk diffusion method was compared to agar dilution method and its repeatability was evaluated, since it has been widely used for the susceptibility testing of campylobacters. The results of the present study showed that resistance to the fluoroquinolones is common in strains isolated from Finnish patients, but resistance to the macrolides is still rare. Multidrug resistance was associated with resistance to both ciprofloxacin and erythromycin. Among the available per oral drugs, least resistance was observed to coamoxiclav There was no resistance to the carbapenems. Sitafloxacin and tigecycline were in vitro highly effective towards Campylobacter species. A point mutation A2059G of the 23S rRNA gene was the main mechanism behind the macrolide resistance, whereas the efflux pumps did not seem to play an important role when a strain had A2059G mutation. A five amino acids insertion, which has not been described previously, in the ribosomal protein L22 of one highly-resistant C. jejuni strain without mutation in the 23S rRNA gene was also detected. Concerning the disk diffusion method, there was variation in the repeatability In conclusion, macrolides still appear to be the first-choice alternative for suspected Campylobacter enteritis. The in vitro susceptibilities found suggest that co-amoxiclav might be a candidate for clinical trials on campylobacteriosis, but in life-threatening situations, a carbapenem may be the drug of choice. More studies are needed on whether the disk diffusion test method could be improved or whether all susceptibilities of campylobacters should be done using a MIC based method.
Resumo:
This work describes techniques for modeling, optimizing and simulating calibration processes of robots using off-line programming. The identification of geometric parameters of the nominal kinematic model is optimized using techniques of numerical optimization of the mathematical model. The simulation of the actual robot and the measurement system is achieved by introducing random errors representing their physical behavior and its statistical repeatability. An evaluation of the corrected nominal kinematic model brings about a clear perception of the influence of distinct variables involved in the process for a suitable planning, and indicates a considerable accuracy improvement when the optimized model is compared to the non-optimized one.
Resumo:
Tämän diplomityön tarkoituksena oli kiinnittää lakkaasientsyymi polyeetterisulfonimembraaniin suodatusominaisuuksien parantamiseksi. Lakkaasientsyymin tiedetään pilkkovan ligniiniä ja kiinnittämällä lakkaasientsyymi membraaniin tavoiteltiin ligniinin aiheuttaman membraanin likaantumisen vähentämistä. Tällöin vältyttäisiin lisäksi erilliseltä esikäsittely vaiheelta ja voitaisiin saada puhtaampi lopputuote. Lakkaasientsyymivalmisteena tutkimuksessa käytettiin Novozym® 51003 ja ristisilloittajana käytettiin glutaarialdehydiä. Vapaan ja kiinnitetyn lakkaasientsyymin aktiivisuuden määritettiin 2,2-atso-bis(3- etyylibentsotiatsolyyli-6-sulfonihappo):n avulla. Lakkaasin kiinnittymistä membraaniin tutkittiin ATR-FTIR spektroskoopilla kiinnittymisen varmentamiseksi. Lakkaasi modifioituja membraaneja testattiin koivu-uute suodatuksella ja adsorptio kokeella. Lakkaasientsyymi saatiin kiinnitettyä membraaniin ristisilloittajan avulla, mutta lakkaasilla modifioitujen membraanien vesivuot laskivat noin puoleen alkuperäisestä. Koivu-uuteen suodatuksissa modifioidusta membraanista ei saatu permeaattia lävitse, mutta adsorptiokokeen tulosten perusteella voidaan todeta lakkaasientsyymin pilkkoneen ligniiniä. Kiinnitetyn lakkaasin aktiivisuus vaihteli rinnakkaisten määritysten välillä, minkä vuoksi lakkaasin kiinnitysmekanismin lisätutkiminen olisi tarpeen luotettavimpien tulosten saamiseksi.
Resumo:
Diplomityön tavoitteena oli kehittää mahdollisimman hyvä koordinaattiohjaus. Sen tuli olla jälkiasennettavissa perinteisen ohjauksen rinnalle työkoneisiin, joissa on käytetty sähköohjattuja proportionaaliventtiileitä. Työssä keskityttiin tutkimaan suuntaventtiilin yli vallitsevasta paine-erosta saatavan tilavuusvirtatiedon hyödyntämistä ohjauksessa. Työn ensimmäisessä vaiheessa koordinaattiohjaus toteutettiin käyttäen 0-peittoisilla karoilla ja karan asematakaisinkytkennällä varustettuja suuntaventtiileitä. Hydrauliseen kuristukseen perustuen saatiin paine-erosta käyttökelpoista tilavuusvirtasignaalia ja koordinaattiohjauksen liikeradan seurannassa oli parhaimmillaan vain 3 cm:n virhe koenosturin työliikkeen pituudella. Toisessa vaiheessa käytettiin työkoneissa yleisesti esiintyvää positiivisin karapeitoin varustettua mobiiliventtiilistöä, jossa oli karakohtaiset painekompensaattorit. Painekompensaattoreiden takia ei paine-eron mittaaminen puhtaasti suuntaventtiilin karan yli ollut mahdollista, jonka takia tyydyttiin koordinaattiohjaus toteuttamaan ilman paineen mittausta luottaen painekompensaattoreiden toimintaan. Käytetyn venttiilistön kavitoinninestotoiminnon huomiointi ohjauksessa jäi ratkaisematta ja se ohitettiin vastusvastaventtiileiden avulla. Koordinaattiohjauksen tarkkuus mobiiliventtiileillä oli vaatimaton ja tulosten toistettavuus heikko. Tulosten perusteella todettiin avoimellakin koordinaattiohjauksella olevan mahdollista saavuttaa lupaava tarkkuus ammattikuljettajiin verrattuna. Mobiiliventtiilistöön liittyvät, työn aikana esiinnousseet epäkohdat olisi ratkaistava ennen käytettyjen menetelmien soveltamista käytännön kohteisiin.