856 resultados para Interfacial Cracks


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work tubular fiber reinforced specimens are tested for fatigue life. The specimens are biaxially loaded with tension and shear stresses, with a load angle β of 30° and 60° and a load ratio of R=0,1. There are many factors that affect fatigue life of a fiber reinforced material and the main goal of this work is to study the effects of load ratio R by obtaining S-N curves and compare them to the previous works (1). All the other parameters, such as specimen production, fatigue loading frequency and temperature, will be the same as for the previous tests. For every specimen, stiffness, temperature of the specimen during testing, crack counting and final fracture mode are obtained. Prior to testing, a study if the literature regarding the load ratio effects on composites fatigue life and with that review estimate the initial stresses to be applied in testing. In previous works (1) similar specimens have only been tested for a load ratio of R=-1 and therefore the behaviour of this tubular specimens for a different load ratio is unknown. All the data acquired will be analysed and compared to the previous works, emphasizing the differences found and discussing the possible explanations for those differences. The crack counting software, developed at the institute, has shown useful before, however different adjustments to the software parameters lead to different cracks numbers for the same picture, and therefore a better methodology will be discussed to improve the crack counting results. After the specimen’s failure, all the data will be collected and stored and fibre volume content for every specimen is also determinate. The number of tests required to make the S-N curves are obtained according to the existent standards. Additionally are also identified some improvements to the testing machine setup and to the procedures for future testing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Para garantir que um equipamento opere com segurança e fiabilidade durante o seu ciclo de vida, desde a sua instalação ao desmantelamento, devem ser realizadas inspeções e/ou monitorizações que, dependendo dos dados recolhidos, podem implicar avaliações Fitness- For-Service (FFS) que definirão a necessidade de reparação ou alteração do equipamento ou das condições processuais. A combinação de inspeção ou monitorização com os melhores procedimentos e técnicas de avaliação atuais fazem sobressair insuficiências dos procedimentos mais antigos. Usando métodos mais avançados de avaliação, validados e suportados através de uma vasta experiência de campo, pode-se agora avaliar defeitos nos ativos (equipamentos) e determinar a adequação ao serviço com uma análise FFS. As análises FFS tornaram-se cada vez mais aceites em toda a indústria ao longo dos últimos anos. A norma API 579 - 1/ASME FFS-1: 2007 fornece diretrizes para avaliar os tipos de danos que afetam os equipamentos processuais e a norma API RP 571: 2011 descreve os mecanismos de degradação que afetam os equipamentos nas petroquímicas e refinarias, que incluem os danos por corrosão, desalinhamentos, deformações plásticas, laminações, fissuras, entre outros. Este trabalho consiste na análise de Integridade Estrutural de uma Flare Industrial que surgiu da necessidade real de análise do equipamento no âmbito da atividade profissional do candidato. O estudo realizado a nível profissional é de grande abrangência, incluindo a inspeção do equipamento, identificação da falha ou dano, recolha e registo de dados, definição de estratégia de atuação e seleção de técnicas de avaliação da condição para posterior alteração, reparação ou desmantelamento. Na presente dissertação de mestrado em Engenharia Mecânica, Ramo Construções Mecânicas, pretende-se efetuar o estudo aprofundado de uma das etapas de projeto, nomeadamente estudar a causa, avaliar a falha e implicações estruturais ou processuais devido à degradação interior do riser de uma flare, com base numa análise FFS, assumindo a operabilidade em segurança e garantindo resolutas condições de funcionamento. A presente análise FFS tem como finalidade validar ou não a integridade atual (avaliação técnica quantitativa) de modo a conhecer se o item em questão é seguro e confiável para continuar a operar em condições específicas durante um período de tempo determinado, tendo em consideração as condições verificadas no ato de inspeção e especificações de projeto, segundo os itens de verificação de segurança estabelecidos na norma EN 1990:2002/A1:2005/AC:2010 e com base na norma API 579-1/ASME FFS-1: 2007. No âmbito do presente trabalho foram realizadas as seguintes tarefas: - Identificar e analisar os mecanismos de degradação com base na norma API RP 571: 2011, face às condições processuais e geométricas que o equipamento em análise está sujeito de modo a perceber a evolução da degradação estrutural e quais as implicações na sua longevidade. - Avaliar e propor soluções de reparação e ou alterações processuais e ou geométricas do equipamento em análise de modo a permitir a continuidade em funcionamento sem afetar as condições de segurança e por conseguinte minimizar ou evitar o elevado custo económico associado a um novo equipamento e tempo de paragem processual. - Assumir limites estruturais face às condições processuais e ações externas ou adjacentes. - Garantir a segurança e qualidade da vida humana ou meio que o rodeia, do equipamento, das instalações, das infraestruturas envolventes e evitar o colapso económico, quer por motivos processuais, quer indeminizações ou agravamento do prémio do seguro. Verificou-se que os resultados serão a base para as alterações inerentes, tais como reforço estrutural, alteração da geometria do defletor, ajuste no tensionamento dos cabos e controlo da espessura mínima, de modo a alargar o período de vida útil da flare com segurança.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Química e Bioquímica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Civil – Perfil de Estruturas

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One of the largest health problems faced worldwide, when evaluated by direct (clinical) as well indirect cost (absenteeism), is the degeneration of the intervertebral disc (IVD) that leads to back pain and, potentially disability and individual´s quality of life decreasing. The intervertebral disc is a mechanical and biological complex structure, formed by a tough outer layer of fibrocartilage called Annulus Fibrosus (AF),which surrounds a soft, elastic and gelatinous core called Nucleus Pulposus (NP). These two structures are completed by two upper and lower encasing layer called Vertebral Endplates (VEP). The degeneration of the IVD is marked by the dehydration of the Nucleus Pulposus, reducing the hydrostatic pressure inside the nucleus, resulting in a loss of capability to support compressive forces, during the active period, and to regain height during the resting period. This situation will compromise the role of shock absorber by the NP and transfers these forces to the AF. This transfer will result in cracks on the AF, deteriorating the IVD, allowing the ingrowth of vessels and nerves. This project was based on the developing a protocol to test suitable NP replacements, in hope to future assessment of discrete mechanical values and characteristics for an NP replacement. For this, Nucleus pulposus samples from goat, encapsulated Hydromed gel denominated “Raviolis” and Chitosan gels, produced via wet route using an ammonium environment, were confined compressed. Chitosan was rheologically tested and swelling capability of all the three type of materials was assessed. Results showed that the Nucleus Pulposus and “Raviolis” have similar mechanical behavior, being able to swell and “build up” hydrostatic pressure after a compression stage, while the Chitosan gel did not showed that ability. Therefore, “Raviolis” are a more suitable candidate to replace the NP than Chitosan gels. It was also observed that confined compression is the key test to perform on any possible candidate to replace the NP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fossils of wood, bone and teeth found along the Upper Purus River οf Amazonia. were studied using conventional microscopy and scanning electron microscopy. Mass spectometry was also used to investigate minor and trace element signatures of bone samples.The microsopy studies showed that there was little alteration of original textures. In the fossil wood samples, identified In thin section as tropical hardwood trees, the replacement of the original material with siderite suggests that fossilization occured in shallow sediments in which interstitial waters were saturated with respect to iron carbenate. In samples of both fossilized bone and wood, precipitation of secondary iron phases was commonly observed in cracks and voids. Other secondary phases Included silica, iron oxides, manganese carbonate. The intimate assοciation οf these secondary phases with the original biological structures could be evidence for a microbiological role in the formation of these phases. The similarity in rare earth element (REE) signatures for 2 fossil bone samples from different modern locations indicates their having shared similar diagenetic histories.The virtually complete preservation of original textures suggests that microscοpic studies could be useful in classifying fossil and even in identifying original materials. Rare carth signatures in fossilized bone may reflect ground water compositions at the time of fossilization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bioactive glass nanoparticles (BGNPs) promote an apatite surface layer in physiologic conditions that lead to a good interfacial bonding with bone.1 A strategy to induce bioactivity in non-bioactive polymeric biomaterials is to incorporate BGNPs in the polymer matrix. This combination creates a nanocomposite material with increased osteoconductive properties. Chitosan (CHT) is a polymer obtained by deacetylation of chitin and is biodegradable, non-toxic and biocompatible. The combination of CHT and the BGNPs aims at designing biocompatible spheres promoting the formation of a calcium phosphate layer at the nanocomposite surface, thus enhancing the osteoconductivity behaviour of the biomaterial. Shape memory polymers (SMP) are stimuli-responsive materials that offer mechanical and geometrical action triggered by an external stimulus.2 They can be deformed and fixed into a temporary shape which remains stable unless exposed to a proper stimulus that triggers recovery of their original shape. This advanced functionality makes such SMPs suitable to be implanted using minimally invasive surgery procedures. Regarding that, the inclusion of therapeutic molecules becomes attractive.  We propose the synthesis of shape memory bioactive nanocomposite spheres with drug release capability.3   1.  L. L. Hench, Am. Ceram. Soc. Bull., 1993, 72, 93-98. 2.  A. Lendlein and S. Kelch, Angew Chem Int Edit, 2002, 41, 2034-2057. 3.  Ã . J. Leite, S. G. Caridade and J. F. Mano, Journal of Non-Crystalline Solids (in Press)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this research, five types of polymer repair materials were selected for investigation of the influence of sample shape, deformation rate and test temperature on the mechanical properties determined with an uniaxial tensile test. The results showed the clear effect of measurement conditions on tensile strength, elongation and modulus of elasticity. The highest tensile strength and modulus of elasticity were exhibited by epoxy resin for the filling of concrete cracks, which achieved 1% elongation. The lowest coefficient of dispersion characterized the results of tensile test carried out using dumbbell samples at a deformation rate of 50 mm/min. The effect of temperature varied with the material type.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the main features of finite element FE numerical model developed using the computer code FEMIX to predict the near-surface mounted NSM carbon-fiber-reinforced polymer CFRP rods shear repair contribution to corroded reinforced concrete RC beams. In the RC beams shear repaired with NSM technique, the Carbon Fibre Reinforced Polymer (CFRP) rods are placed inside pre-cut grooves onto the concrete cover of the RC beam’s lateral faces and are bonded to the concrete with high epoxy adhesive. Experimental and 3D numerical modelling results are presented in this paper in terms of load-deflection curves, and failure modes for 4 short corroded beams: two corroded beams (A1CL3-B and A1CL3-SB) and two control beams (A1T-B and A1T-SB), the beams noted with B were let repaired in bending only with NSM CFRP rods while the ones noted with SB were repaired in both bending and shear with NSM technique. The corrosion of the tensile steel bars and its effect on the shear capacity of the RC beams was discussed. Results showed that the FE model was able to capture the main aspects of the experimental load-deflection curves of the RC beams, moreover it has presented the experimental failure modes and FE numerical modelling crack patterns and both gave similar results for non-shear repaired beams which failed in diagonal tension mode of failure and for shear-repaired beams which failed due to large flexural crack at the middle of the beams along with the concrete crushing, three dimensional crack patterns were produced for shear-repaired beams in order to investigate the splitting cracks occurred at the middle of the beams and near the support.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Using prestressed near surface mounted fibre reinforced polymers (NSM-FRP) is nowadays regaining the attention from the scientific community for the strengthening of existing reinforced concrete (RC) structures. The application of prestressed internal FRP bars and externally bonded prestressed FRPs has already been deeply investigated and revealed considerable benefits when compared to the corresponding passive solutions. A certain amount of prestress provides benefits mainly associated to structural integrity and material durability. Immediately after prestress transference, it is possible to close some of the existing cracks, decreasing the susceptibility of the element to corrosion and, a certain amount of deflection can be recovered due to the creation of a negative curvature. However, very few studies have been carried out to properly assess the preservation of prestress over time. In this context, several reinforced concrete beams strengthened with prestressed NSM carbon FRP (CFRP) laminates were prestressed and monitored for about 40 days. The data obtained from these experimental programs is in this paper presented and analysed. The observed prestress losses were later modelled using finite elements analysis and, although this topic is not addressed in this paper, the obtained results revealed considerable precision. The largest strain losses in the CFRP laminate were found to be mainly located in the extremities of the bonded length, while in the central zone most of the applied pre-strain was retained over time. The highest CFRP strain losses were observed in the first 6 to 12 days after prestress transfer, suggesting that the application of prestressed NSM-FRP will be very effective over time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The reinforcement mechanisms at the cross section level assured by fibres bridging the cracks in steel fibre reinforced self-compacting concrete (SFRSCC) can be significantly amplified at structural level when the SFRSCC is applied in structures with high support redundancy, such is the case of elevated slab systems. To evaluate the potentialities of SFRSCC as the fundamental material of elevated slab systems, a ¼ scale SFRSCC prototype of a residential building was designed, built and tested. The extensive experimental program includes material tests for characterizing the relevant properties of SFRSCC, as well as structural tests for assessing the performance of the prototype at serviceability and ultimate limit conditions. Three distinct approaches where adopted to derive the constitutive laws of the SFRSCC in tension that were used in finite element material nonlinear analysis to evaluate the reliability of these approaches in the prediction of the load carrying capacity of the prototype.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of prestressed near surface mounted fibre reinforced polymers (NSM-FRP) has been long acknowledged to be a suitable approach to strengthen and retrofit existing reinforced concrete structures. The application of a certain amount of prestress to the FRP prior to its installation provides a number of benefits, mainly related to crack width and deflection requisites at serviceability limit state conditions. After transferring the prestress to a structural element, some of the existing cracks can be closed, decreasing the vulnerability of the element to corrosion and, a certain amount of deflection can be recovered due to the introduced negative curvature. However, these benefits can only be assured if the prestress is properly preserved over time. In this context, three series of reinforced concrete beams, in a total of 10 beams, were strengthened with a prestressed carbon FRP laminate (CFRP) and monitored for about 40 days. The data obtained from these tests is in this paper presented and analysed. The observed losses of strain in the CFRP laminate were found to be mainly located in the extremities of the bonded length, while in the central zone most of the initial strain was well-preserved over time. Additionally, the highest CFRP strain losses were observed in the first 6 to 12 days after prestress transfer, suggesting that the benefits of prestressed NSM-FRP will not be considerably lost over time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the main features of finite element FE numerical model developed using the computer code FEMIX to predict the near-surface mounted NSM carbon-fiber-reinforced polymer CFRP rods shear repair contribution to corroded reinforced concrete RC beams. In the RC beams shear repaired with NSM technique, the Carbon Fibre Reinforced Polymer (CFRP) rods are placed inside pre-cut grooves onto the concrete cover of the RC beam’s lateral faces and are bonded to the concrete with high epoxy adhesive. Experimental and 3D numerical modelling results are presented in this paper in terms of load-deflection curves, failure modes and slip information of the tensile steel bars for 4 short corroded beams: two corroded beams (A1CL3-B and A1CL3-SB) and two control beams (A1T-B and A1T-SB), the beams noted with B were let repaired in bending only with NSM CFRP rods while the ones noted with SB were repaired in both bending and shear with NSM technique. The corrosion of the tensile steel bars and its effect on the shear capacity of the RC beams was discussed. Results showed that the FE model was able to capture the main aspects of the experimental load-deflection curves of the RC beams, moreover it has presented the experimental failure modes and FE numerical modelling crack patterns and both gave similar results for non-shear repaired beams which failed in diagonal tension mode of failure and for shear-repaired beams which failed due to large flexural crack at the middle of the beams along with the concrete crushing, three dimensional crack patterns were produced for shear-repaired beams in order to investigate the splitting cracks occurred at the middle of the beams and near the support.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work proposes a constitutive model to simulate nonlinear behaviour of cement based materials subjected to different loading paths. The model incorporates a multidirectional fixed smeared crack approach to simulate crack initiation and propagation, whereas the inelastic behaviour of material between cracks is treated by a numerical strategy that combines plasticity and damage theories. For capturing more realistically the shear stress transfer between the crack surfaces, a softening diagram is assumed for modelling the crack shear stress versus crack shear strain. The plastic damage model is based on the yield function, flow rule and evolution law for hardening variable, and includes an explicit isotropic damage law to simulate the stiffness degradation and the softening behaviour of cement based materials in compression. This model was implemented into the FEMIX computer program, and experimental tests at material scale were simulated to appraise the predictive performance of this constitutive model. The applicability of the model for simulating the behaviour of reinforced concrete shear wall panels submitted to biaxial loading conditions, and RC beams failing in shear is investigated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The acoustic emission (AE) technique is used for investigating the interfacial fracture and damage propagation in GFRP-and SRG-strengthened bricks during debonding tests. The bond behavior is investigated through single-lap shear bond tests and the fracture progress during the tests is recorded by means of AE sensors. The fracture progress and active debonding mechanisms are characterized in both specimen types with the aim of AE outputs. Moreover, a clear distinction between the AE outputs of specimens with different failure modes, in both SRG-and GFRP-strengthened specimens, is found which allows characterizing the debonding failure mode based on acoustic emission data.