904 resultados para In-process


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Reducing wafer metrology continues to be a major target in semiconductor manufacturing efficiency initiatives due to it being a high cost, non-value added operation that impacts on cycle-time and throughput. However, metrology cannot be eliminated completely given the important role it plays in process monitoring and advanced process control. To achieve the required manufacturing precision, measurements are typically taken at multiple sites across a wafer. The selection of these sites is usually based on a priori knowledge of wafer failure patterns and spatial variability with additional sites added over time in response to process issues. As a result, it is often the case that in mature processes significant redundancy can exist in wafer measurement plans. This paper proposes a novel methodology based on Forward Selection Component Analysis (FSCA) for analyzing historical metrology data in order to determine the minimum set of wafer sites needed for process monitoring. The paper also introduces a virtual metrology (VM) based approach for reconstructing the complete wafer profile from the optimal sites identified by FSCA. The proposed methodology is tested and validated on a wafer manufacturing metrology dataset. © 2012 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Topic

To compare the accuracy of optical coherence tomography (OCT) with alternative tests for monitoring neovascular age-related macular degeneration (nAMD) and detecting disease activity among eyes previously treated for this condition.

Clinical Relevance

Traditionally, fundus fluorescein angiography (FFA) has been considered the reference standard to detect nAMD activity, but FFA is costly and invasive. Replacement of FFA by OCT can be justified if there is a substantial agreement between tests.

Methods

Systematic review and meta-analysis. The index test was OCT. The comparator tests were visual acuity, clinical evaluation (slit lamp), Amsler chart, color fundus photographs, infrared reflectance, red-free images and blue reflectance, fundus autofluorescence imaging, indocyanine green angiography (ICGA), preferential hyperacuity perimetry, and microperimetry. We searched the following databases: MEDLINE, MEDLINE In-Process, EMBASE, Biosis, Science Citation Index, the Cochrane Library, Database of Abstracts of Reviews of Effects, MEDION, and the Health Technology Assessment database. The last literature search was conducted in March 2013. We used the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) to assess risk of bias.

Results

We included 8 studies involving more than 400 participants. Seven reported the performance of OCT (3 time-domain [TD] OCT, 3 spectral-domain [SD] OCT, 1 both types) and 1 reported the performance of ICGA in the detection of nAMD activity. We did not find studies directly comparing tests in the same population. The pooled sensitivity and specificity of TD OCT and SD OCT for detecting active nAMD was 85% (95% confidence interval [CI], 72%–93%) and 48% (95% CI, 30%–67%), respectively. One study reported ICGA with sensitivity of 75.9% and specificity of 88.0% for the detection of active nAMD. Half of the studies were considered to have a high risk of bias.

Conclusions

There is substantial disagreement between OCT and FFA findings in detecting active disease in patients with nAMD who are being monitored. Both methods may be needed to monitor patients comprehensively with nAMD.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Age-related macular degeneration is the most common cause of sight impairment in the UK. In neovascular age-related macular degeneration (nAMD), vision worsens rapidly (over weeks) due to abnormal blood vessels developing that leak fluid and blood at the macula.

OBJECTIVES: To determine the optimal role of optical coherence tomography (OCT) in diagnosing people newly presenting with suspected nAMD and monitoring those previously diagnosed with the disease.

DATA SOURCES: Databases searched: MEDLINE (1946 to March 2013), MEDLINE In-Process & Other Non-Indexed Citations (March 2013), EMBASE (1988 to March 2013), Biosciences Information Service (1995 to March 2013), Science Citation Index (1995 to March 2013), The Cochrane Library (Issue 2 2013), Database of Abstracts of Reviews of Effects (inception to March 2013), Medion (inception to March 2013), Health Technology Assessment database (inception to March 2013).

REVIEW METHODS: Types of studies: direct/indirect studies reporting diagnostic outcomes.

INDEX TEST: time domain optical coherence tomography (TD-OCT) or spectral domain optical coherence tomography (SD-OCT).

COMPARATORS: clinical evaluation, visual acuity, Amsler grid, colour fundus photographs, infrared reflectance, red-free images/blue reflectance, fundus autofluorescence imaging, indocyanine green angiography, preferential hyperacuity perimetry, microperimetry. Reference standard: fundus fluorescein angiography (FFA). Risk of bias was assessed using quality assessment of diagnostic accuracy studies, version 2. Meta-analysis models were fitted using hierarchical summary receiver operating characteristic curves. A Markov model was developed (65-year-old cohort, nAMD prevalence 70%), with nine strategies for diagnosis and/or monitoring, and cost-utility analysis conducted. NHS and Personal Social Services perspective was adopted. Costs (2011/12 prices) and quality-adjusted life-years (QALYs) were discounted (3.5%). Deterministic and probabilistic sensitivity analyses were performed.

RESULTS: In pooled estimates of diagnostic studies (all TD-OCT), sensitivity and specificity [95% confidence interval (CI)] was 88% (46% to 98%) and 78% (64% to 88%) respectively. For monitoring, the pooled sensitivity and specificity (95% CI) was 85% (72% to 93%) and 48% (30% to 67%) respectively. The FFA for diagnosis and nurse-technician-led monitoring strategy had the lowest cost (£39,769; QALYs 10.473) and dominated all others except FFA for diagnosis and ophthalmologist-led monitoring (£44,649; QALYs 10.575; incremental cost-effectiveness ratio £47,768). The least costly strategy had a 46.4% probability of being cost-effective at £30,000 willingness-to-pay threshold.

LIMITATIONS: Very few studies provided sufficient information for inclusion in meta-analyses. Only a few studies reported other tests; for some tests no studies were identified. The modelling was hampered by a lack of data on the diagnostic accuracy of strategies involving several tests.

CONCLUSIONS: Based on a small body of evidence of variable quality, OCT had high sensitivity and moderate specificity for diagnosis, and relatively high sensitivity but low specificity for monitoring. Strategies involving OCT alone for diagnosis and/or monitoring were unlikely to be cost-effective. Further research is required on (i) the performance of SD-OCT compared with FFA, especially for monitoring but also for diagnosis; (ii) the performance of strategies involving combinations/sequences of tests, for diagnosis and monitoring; (iii) the likelihood of active and inactive nAMD becoming inactive or active respectively; and (iv) assessment of treatment-associated utility weights (e.g. decrements), through a preference-based study.

STUDY REGISTRATION: This study is registered as PROSPERO CRD42012001930.

FUNDING: The National Institute for Health Research Health Technology Assessment programme.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A commercial polymeric film (Parafilm M (R), a blend of a hydrocarbon wax and a polyolefin) was evaluated as a model membrane for microneedle (MN) insertion studies. Polymeric MN arrays were inserted into Parafilm M (R) (PF) and also into excised neonatal porcine skin. Parafilm M (R) was folded before the insertions to closely approximate thickness of the excised skin. Insertion depths were evaluated using optical coherence tomography (OCT) using either a force applied by a Texture Analyser or by a group of human volunteers. The obtained insertion depths were, in general, slightly lower, especially for higher forces, for PF than for skin. However, this difference was not a large, being less than the 10% of the needle length. Therefore, all these data indicate that this model membrane could be a good alternative to biological tissue for MN insertion studies. As an alternative method to OCT, light microscopy was used to evaluate the insertion depths of MN in the model membrane. This provided a rapid, simple method to compare different MN formulations. The use of Parafilm M (R), in conjunction with a standardised force/time profile applied by a Texture Analyser, could provide the basis for a rapid MN quality control test suitable for in-process use. It could also be used as a comparative test of insertion efficiency between candidate MN formulations. 

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this study, calcium phosphate (CaP) powders were blended with a three-dimensional printing (3DP) calcium sulfate (CaSO4)-based powder and the resulting composite powders were printed with a water-based binder using the 3DP technology. Application of a water-based binder ensured the manufacture of CaP:CaSO4 constructs on a reliable and repeatable basis, without long term damage of the printhead. Printability of CaP:CaSO4 powders was quantitatively assessed by investigating the key 3DP process parameters, i.e. in-process powder bed packing, drop penetration behavior and the quality of printed solid constructs. Effects of particle size, CaP:CaSO4 ratio and CaP powder type on the 3DP process were considered. The drop penetration technique was used to reliably identify powder formulations that could be potentially used for the application of tissue engineered bone scaffolds using the 3DP technique. Significant improvements (p < 0.05) in the 3DP process parameters were found for CaP (30-110 μm):CaSO4 powders compared to CaP (< 20 μm):CaSO4 powders. Higher compressive strength was obtained for the powders with the higher CaP:CaSO4 ratio. Hydroxyapatite (HA):CaSO4 powders showed better results than beta-tricalcium phosphate (β-TCP):CaSO4 powders. Solid and porous constructs were manufactured using the 3DP technique from the optimized CaP:CaSO4 powder formulations. High-quality printed constructs were manufactured, which exhibited appropriate green compressive strength and a high level of printing accuracy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Viscosity represents a key indicator of product quality in polymer extrusion but has traditionally been difficult to measure in-process in real-time. An innovative, yet simple, solution to this problem is proposed by a Prediction-Feedback observer mechanism. A `Prediction' model based on the operating conditions generates an open-loop estimate of the melt viscosity; this estimate is used as an input to a second, `Feedback' model to predict the pressure of the system. The pressure value is compared to the actual measured melt pressure and the error used to correct the viscosity estimate. The Prediction model captures the relationship between the operating conditions and the resulting melt viscosity and as such describes the specific material behavior. The Feedback model on the other hand describes the fundamental physical relationship between viscosity and extruder pressure and is a function of the machine geometry. The resulting system yields viscosity estimates within 1% error, shows excellent disturbance rejection properties and can be directly applied to model-based control. This is of major significance to achieving higher quality and reducing waste and set-up times in the polymer extrusion industry.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Seasonal/perennial allergic conjunctivitis is the most common allergic conjunctivitis, usually with acute manifestations when a person is exposed to allergens and with typical signs and symptoms including itching, redness, and tearing. The clinical signs and symptoms of allergic conjunctivitis are mediated by the release of histamine by mast cells. Histamine antagonists (also called antihistamines) inhibit the action of histamine by blocking histamine H1 receptors, antagonising the vasoconstrictor, and to a lesser extent, the vasodilator effects of histamine. Mast cell stabilisers inhibit degranulation and consequently the release of histamine by interrupting the normal chain of intracellular signals. Topical treatments include eye drops with antihistamines, mast cell stabilisers, non-steroidal anti-inflammatory drugs, combinations of the previous treatments, and corticosteroids. Standard treatment is based on topical antihistamines alone or topical mast cell stabilisers alone or a combination of treatments. There is clinical uncertainty about the relative efficacy and safety of topical treatment.

OBJECTIVES: The objective of this review was to assess the effects of topical antihistamines and mast cell stabilisers, alone or in combination, for use in treating seasonal and perennial allergic conjunctivitis.

SEARCH METHODS: We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register) (2014, Issue 7), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to July 2014), EMBASE (January 1980 to July 2014), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 17 July 2014. We also searched the reference lists of review articles and relevant trial reports for details of further relevant publications.

SELECTION CRITERIA: We included randomised controlled trials (RCTs) comparing topical antihistamine and mast cell stabilisers, alone or in combination, with placebo, no treatment or to any other antihistamine or mast cell stabiliser, or both, that examined people with seasonal or perennial allergic conjunctivitis, or both. The primary outcome was any participant-reported evaluation (by questionnaire) of severity of four main ocular symptoms: itching, irritation, watering eye (tearing), and photophobia (dislike of light), both separately and, if possible, by an overall symptom score. We considered any follow-up time between one week and one year.

DATA COLLECTION AND ANALYSIS: Two review authors independently extracted data and assessed risk of bias. Disagreements were resolved by discussion among review authors and the involvement of a third review author. We followed standard methodological approaches used by Cochrane.

MAIN RESULTS: We identified 30 trials with a total of 4344 participants randomised, with 17 different drugs or treatment comparisons. The following antihistamines and mast cell stabilisers were evaluated in at least one RCT: nedocromil sodium or sodium cromoglycate, olopatadine, ketotifen, azelastine, emedastine, levocabastine (or levocabastine), mequitazine, bepotastine besilate, combination of antazoline and tetryzoline, combination of levocabastine and pemirolast potassium. The most common comparison was azelastine versus placebo (nine studies).We observed a large variability in reporting outcomes. The quality of the studies and reporting was variable, but overall the risk of bias was low. Trials evaluated only short-term effects, with a range of treatment of one to eight weeks. Meta-analysis was only possible in one comparison (olopatadine versus ketotifen). There was some evidence to support that topical antihistamines and mast cell stabilisers reduce symptoms and signs of seasonal allergic conjunctivitis when compared with placebo. There were no reported serious adverse events related to the use of topical antihistamine and mast cell stabilisers treatment.

AUTHORS' CONCLUSIONS: It seems that all reported topical antihistamines and mast cell stabilisers reduce symptoms and signs of seasonal allergic conjunctivitis when compared with placebo in the short term. However, there is no long-term data on their efficacy. Direct comparisons of different antihistamines and mast cell stabilisers need to be interpreted with caution. Overall, topical antihistamines and mast cell stabilisers appear to be safe and well tolerated. We observed a large variability in outcomes reported. Poor quality of reporting challenged the synthesis of evidence.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents an automated design framework for the development of individual part forming tools for a composite stiffener. The framework uses parametrically developed design geometries for both the part and its layup tool. The framework has been developed with a functioning user interface where part / tool combinations are passed to a virtual environment for utility based assessment of their features and assemblability characteristics. The work demonstrates clear benefits in process design methods with conventional design timelines reduced from hours and days to minutes and seconds. The methods developed here were able to produce a digital mock up of a component with its associated layup tool in less than 3 minutes. The virtual environment presenting the design to the designer for interactive assembly planning was generated in 20 seconds. Challenges still exist in determining the level of reality required to provide an effective learning environment in the virtual world. Full representation of physical phenomena such as gravity, part clashes and the representation of standard build functions require further work to represent real physical phenomena more accurately.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Este trabalho tem como objectivo a medição da solubilidade de gases em líquidos a altas pressões. Para a realização experimental foi usada uma célula de altas pressões de volume variável e um método de observação directa para a detecção das transições de fase. As condições usadas neste trabalho experimental foram temperaturas entre 276.00 e 373.15 K e pressões ate 100 MPa. Numa primeira fase foram efectuadas medições de solubilidade de metano em anilina pura e para uma solução aquosa de composição mássica igual a 5% em anilina. A anilina é fundamentalmente usada em processos como a produção de borracha, de poliuretanos, pigmentos e tintas, fármacos, herbicidas e fungicidas. É usualmente produzida através de processos de redução do nitrobenzeno por reacção com o HCl. De facto, esta síntese é um processo químico complexo onde um grande número de processos compete entre si. Alterações nas condições do processo com a possível formação de produtos intermediários podem afectar a eficiência do processo. Para a sua melhoria foi sugerido que o hidrogénio usado fosse simultaneamente produzido e gasto no reactor principal. Neste caso e para a produção do mesmo, era necessário adicionar metano e água ao reactor. Tendo por base a ideia de que as reacções onde o hidrogénio é reagente e produto ocorrem em simultâneo, torna-se clara a importância do estudo da solubilidade do metano em anilina pura e em soluções aquosas desta. Numa segunda fase foi estudada a solubilidade do dióxido de carbono em soluções aquosas de tri-iso-butil(metil)fosfónio tosilato, com composições molares são de 4, 8 e 12% em líquido iónico. Este pertencente à família dos fosfónios. Possui uma viscosidade e densidade elevadas, é térmica e quimicamente estável e ainda possui uma elevada polaridade. Apresenta uma miscibilidade completa em água e nos solventes mais usuais, como o diclorometano e tolueno, não sendo no entanto míscivel em hexano. O tri-isobutil( metil)fosfónium tosilato é usado como solvente nos processos de hidroformilação de olefinas e ainda em processos de captura e conversão de dióxido de carbono. Neste trabalho experimental, a temperatura e a pressão foram inicialmente aumentadas até o sistema atingir o equilíbrio. A pressão é diminuída lentamente até se verificar o aparecimento/desaparecimento da última bolha de gás. A pressão à qual a última bolha de gás desaparece representa a pressão de equilíbrio para aquela temperatura. Este procedimento foi efectuado para vários sistemas e várias temperaturas.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Relatório da Prática de Ensino Supervisionada, Mestrado em Ensino de História e Geografia no 3º ciclo do Ensino Básico e Secundário, Universidade de Lisboa, 2014

Relevância:

60.00% 60.00%

Publicador:

Resumo:

As operações de separação por adsorção têm vindo a ganhar importância nos últimos anos, especialmente com o desenvolvimento de técnicas de simulação de leitos móveis em colunas, tal como a cromatografia de Leito Móvel Simulado (Simulated Moving Bed, SMB). Esta tecnologia foi desenvolvida no início dos anos 60 como método alternativo ao processo de Leito Móvel Verdadeiro (True Moving Bed, TMB), de modo a resolver vários dos problemas associados ao movimento da fase sólida, usuais nestes métodos de separação cromatográficos de contracorrente. A tecnologia de SMB tem sido amplamente utilizada em escala industrial principalmente nas indústrias petroquímica e de transformação de açúcares e, mais recentemente, na indústria farmacêutica e de química fina. Nas últimas décadas, o crescente interesse na tecnologia de SMB, fruto do alto rendimento e eficiente consumo de solvente, levou à formulação de diferentes modos de operação, ditos não convencionais, que conseguem unidades mais flexíveis, capazes de aumentar o desempenho de separação e alargar ainda mais a gama de aplicação da tecnologia. Um dos exemplos mais estudados e implementados é o caso do processo Varicol, no qual se procede a um movimento assíncrono de portas. Neste âmbito, o presente trabalho foca-se na simulação, análise e avaliação da tecnologia de SMB para dois casos de separação distintos: a separação de uma mistura de frutose-glucose e a separação de uma mistura racémica de pindolol. Para ambos os casos foram considerados e comparados dois modos de operação da unidade de SMB: o modo convencional e o modo Varicol. Desta forma, foi realizada a implementação e simulação de ambos os casos de separação no simulador de processos Aspen Chromatography, mediante a utilização de duas unidades de SMB distintas (SMB convencional e SMB Varicol). Para a separação da mistura frutose-glucose, no quediz respeito à modelização da unidade de SMB convencional, foram utilizadas duas abordagens: a de um leito móvel verdadeiro (modelo TMB) e a de um leito móvel simulado real (modelo SMB). Para a separação da mistura racémica de pindolol foi considerada apenas a modelização pelo modelo SMB. No caso da separação da mistura frutose-glucose, procedeu-se ainda à otimização de ambas as unidades de SMB convencional e Varicol, com o intuito do aumento das suas produtividades. A otimização foi realizada mediante a aplicação de um procedimento de planeamento experimental, onde as experiências foram planeadas, conduzidas e posteriormente analisadas através da análise de variância (ANOVA). A análise estatística permitiu selecionar os níveis dos fatores de controlo de modo a obter melhores resultados para ambas as unidades de SMB.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O presente trabalho de dissertação teve como objetivo a implementação de metodologias de Lean Management e avaliação do seu impacto no processo de Desenvolvimento de Produto. A abordagem utilizada consistiu em efetuar uma revisão da literatura e levantamento do Estado da Arte para obter a fundamentação teórica necessária à implementação de metodologias Lean. Prosseguiu com o levantamento da situação inicial da organização em estudo ao nível das atividades de desenvolvimento de produto, práticas de gestão documental e operacional e ainda de atividades de suporte através da realização de inquéritos e medições experimentais. Este conhecimento permitiu criar um modelo de referência para a implementação de Lean Management nesta área específica do desenvolvimento de produto. Após implementado, este modelo foi validado pela sua experimentação prática e recolha de indicadores. A implementação deste modelo de referência permitiu introduzir na Unidade de Desenvolvimento de Produto e Sistemas (DPS) da organização INEGI, as bases do pensamento Lean, contribuindo para a criação de um ambiente de Respeito pela Humanidade e de Melhoria Contínua. Neste ambiente foi possível obter ganhos qualitativos e quantitativos nas várias áreas em estudo, contribuindo de forma global para um aumento da eficiência e eficácia da DPS. Prevê-se que este aumento de eficiência represente um aumento da capacidade instalada na Organização, pela redução anual de 2290 horas de desperdício (6.5% da capacidade total da unidade) e pela redução significativa em custos operacionais. Algumas das implementações de melhoria propostas no decorrer deste trabalho, após verificado o seu sucesso, extravasaram a unidade em estudo e foram aplicadas transversalmente à da organização. Foram também obtidos ganhos qualitativos, tais como a normalização de práticas de gestão documental e a centralização e agilização de fluxos de informação. Isso permitiu um aumento de qualidade dos serviços prestados pela redução de correções e retrabalho. Adicionalmente, com o desenvolvimento de uma nova ferramenta que permite a monitorização do estado atual dos projetos a nível da sua percentagem de execução (cumprimento de objetivos), prazos e custos, bem como a estimação das datas de conclusão dos projetos possibilitando o replaneamento do projeto bem como a detecção atempada de desvios. A ferramenta permite também a criação de um histórico que identifica o esforço horário associado à realização das atividades/tarefas das várias áreas de Desenvolvimento de Produto e desta forma pode ser usada como suporte à orçamentação futura de atividades similares. No decorrer do projeto, foram também criados os mecanismos que permitem o cálculo de indicadores das competências técnicas e motivações intrínsecas individuais da equipa DPS. Estes indicadores podem ser usados na definição por parte dos gestores dos projetos da composição das equipas de trabalho, dos executantes de tarefas individuais do projeto e dos destinatários de ações de formação. Com esta informação é expectável que se consiga um maior aproveitamento do potencial humano e como consequência um aumento do desempenho e da satisfação pessoal dos recursos humanos da organização. Este caso de estudo veio demonstrar que o potencial de melhoria dos processos associados ao desenvolvimento de produto através de metodologias de Lean Management é muito significativo, e que estes resultam em ganhos visíveis para a organização bem como para os seus elementos individualmente.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Software development is a discipline that is almost as old as the history of computers. With the advent of the Internet and all of its related technologies, software development has been on high demand. But, and especially in SME (small and medium enterprise), this was not accompanied with a comparable effort to develop a set of sustainable and standardized activities of project management, which lead to increasing inefficiencies and costs. Given the actual economic situation, it makes sense to engage in an effort to reduce said inefficiencies and rising costs. For that end, this work will analyze the current state of software development’s project management processes on a Portuguese SME, along with its problems and inefficiencies in an effort to create a standardized model to manage software development, with special attention given to critical success factors in an agile software development environment, while using the best practices in process modeling. This work also aims to create guidelines to correctly integrate these changes in the existing IS structure of a company.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This thesis uses a multifaceted process to engage with the topic of food sovereignty in California. It employs diverse methods, including critical and creative prose, photography, autoethnographic mixed media, storytelling and poetry. I am particularly concerned with the " " challenges of approaching food sovereignty, a radical praxis that combines subsistence practices with anti-capitalist resistance, while in my own "skin," which is thoroughly embedded in white, urban, middle classed culture and in corltextualizing ecological relationshipslkinships via cultural, historical and economic trajectories. The project utilizes a processual methodlology drawing substantially from the work of Brian Massumi to explore these issues through four creative narrative pieces which coalesce around the elemental metaphors of air, fire, water and earth. Following Deleuze and Guatarri's concept ofrhizomatic plateaus, the thesis narratives are comprised of many non-hierarchical layers and can be read from many angles. Each is offered "in process" rather than as a finished piece, thus practically validating the concept of the ongoing work of research and suggesting the equally omnipresent possibility of change and mutation in the formation relationally based knowledges. Cultivating ecological ethic and healing on multisensory levels, as well as commitment to emergent and re-productivist worldviews are goals of this project's research.