913 resultados para IMPLANT SURFACES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The aim of this study was to evaluate the mid-term biocompatibility of a new x-shaped implant made of zirconium in an animal model of glaucoma surgery. METHODS: Preoperatively, ultrasound biomicroscopy (UBM), intraocular pressure (IOP) and outflow facility (OF) data were acquired. Upon surgery, one eye was chosen randomly to receive an implant, while the other received none. Ten rabbits went through a 1-, 2-, 3-, 4- and 6-month follow-up. IOP was measured regularly, UBM performed at 1, 3 and 6 months after surgery. At the end of the follow-up, OF was again measured. Histology sections were analyzed. RESULTS: For both groups IOP control was satisfactory, while OF initially increased at month 1 to resume preoperative values thereafter. Eyes with implants had larger filtration blebs which decreased faster than in eyes without the implant. Drainage vessel density, inflammatory cell number and fibrosis were higher in tissues near the implant. CONCLUSIONS: The zirconium implant initially promoted the positive effects of the surgery (IOP control, OF increase). Nevertheless, after several months, foreign body reactions and fibrosis had occurred on some implants that restrained the early benefit of such a procedure. Modifications of the zirconium implant geometry could enhance the overall success rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: To compare the efficacy and longevity of nonpenetrating glaucoma surgery with and without the use of a nonabsorbable hydrophilic implant at the Oxford Eye Centre, Johannesburg, South Africa, and the Glaucoma Unit, Jules Gonin Ophthalmic Hospital, Lausanne, Switzerland. PATIENTS AND METHODS: In a nonrandomized, prospective study between March 1997 and December 2001, 48 eyes of 32 patients aged 18 to 86 years with primary open-angle glaucoma underwent nonpenetrating glaucoma surgery; 25 eyes with the implant and 23 eyes without it. Intraocular pressure (IOP) was recorded preoperatively and postoperatively at 1, 7, and 14 days, at 1, 3, and 6 months, and thereafter every 6 months. RESULTS: The mean preoperative IOP was 27.5 +/- 11.8 mm Hg (range, 20 to 64 mm Hg) in the implant group and 24.8 +/- 7.1 mm Hg (range, 16 to 38 mm Hg) in the control group. During the first 18 months of follow-up, both groups showed identical IOP progression and the mean IOP remained less than 14 mm Hg. After 2 years of follow-up, the IOP started to rise in the control group but remained stable in the implant group. After 30 months, the mean IOP was 12.4 +/- 2 mm Hg and the IOP decrease in percentage was 62% +/- 6% in the implant group (n = 13) versus 16.1 +/- 3 mm Hg and 34% +/- 13% in the control group (n = 15) (mean IOP, P = .0022; mean IOP decrease in percentage, P = .01). CONCLUSIONS: During the first 18 months, there was no difference in the outcomes between the two groups. After 2 years of follow-up, the mean IOP was lower and the IOP decrease in percentage was greater in the implant group compared with the control group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé : Le condylome acuminé anal (CAA), transmis par contact sexuel, résulte d'une infection par Human Papilloma Virus (HPV). Son traitement chirurgical est grevé d'un taux de récidive de 4-29%. Le but de cette étude était d'identifier une éventuelle corrélation entre type d'HPV présent dans les CAA excisés chirurgicalement et taux de récidive de la maladie, ? Cette étude rétrospective porte sur 140 patients opérés au Centre Hospitalier Universitaire Vaudois de CAA, entre 1990 et 2005. Le diagnostic lésionnel a été confirmé par un examen histomorphologique. Le(s) type(s) d'HPV présent(s) dans ces lésions a été déterminé par Polymerase Chain Reaction (PCR). Les patients ont donné leur accord à cette analyse et complété un questionnaire. Une éventuelle corrélation entre récidive de CAA, type d'HPV et status HIV a été recherchée. HPV 6 et 11 sont les virus les plus fréquemment découverts (51% et 28%, respectivement) chez les 140 patients (123H/17F). Trente-cinq (25%) d'entre eux ont présenté une récidive. HPV 11 était present chez 19 (41%) sujets. Ceci est statistiquement significatif (P<0.05), en comparaison aux autres HPVs. Il n'y a par contre pas de différence significative entre la fréquence de récidive des 33 (24%) patients HIV-positifs et le reste du collectif. HPV 11 est donc associé à un taux de récidive de CAA significativement élevé. Un suivi strict des patients atteints est nécessaire pour identifier une récidive et la traiter sans délai, notamment lorsque HPV 11 est present. Ces résultats innovateurs soulèvent la question de la nécessité de pratiquer une typisation virale systématique sur les lésions excisées. La justification d'une telle attitude demande toutefois encore d'être confirmée.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: We investigate a new heat delivery technique for the local treatment of solid tumors. The technique involves injecting a formulation that solidifies to form an implant in situ. This implant entraps superparamagnetic iron oxide nanoparticles (SPIONs) embedded in silica microbeads for magnetically induced moderate hyperthermia. Particle entrapment prevents phagocytosis and distant migration of SPIONs. The implant can be repeatedly heated by magnetic induction. Methods: We evaluated heating and treatment efficacies by means of thermometry and survival studies in nude mice carrying subcutaneous human colocarcinomas. At day 1, we injected the formulation into the tumor. At day 2, a single 20-min hyperthermia treatment was delivered by 141-kHz magnetic induction using field strengths of 9 to 12 mT under thermometry. Results: SPIONs embedded in silica microbeads were effectively confined within the implant at the injection site. Heat-induced necro-apoptosis was assessed by histology on day 3. On average, 12 mT resulted in tumor temperature of 47.8 degrees C, and over 70% tumor necrosis that correlated to the heat dose (AUC = 282 degrees C.min). In contrast, a 9-mT field strength induced tumoral temperature of 40 degrees C (AUC = 131 degrees C.min) without morphologically identifiable necrosis. Survival after treatment with 10.5 or 12 mT fields was significantly improved compared to non-implanted and implanted controls. Median survival times were 27 and 37 days versus 12 and 21 days respectively. Conclusion: Five of eleven mice (45%) of the 12 mT group survived one year without any tumor recurrence, holding promise for tumor therapy using magnetically induced moderate hyperthermia through injectable implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bacteria can survive on hospital textiles and surfaces, from which they can be disseminated, representing a source of health care-associated infections (HCAIs). Surfaces containing copper (Cu), which is known for its bactericidal properties, could be an efficient way to lower the burden of potential pathogens. The antimicrobial activity of Cu-sputtered polyester surfaces, obtained by direct-current magnetron sputtering (DCMS), against methicillin-resistant Staphylococcus aureus (MRSA) was tested. The Cu-polyester microstructure was characterized by high-resolution transmission electron microscopy to determine the microstructure of the Cu nanoparticles and by profilometry to assess the thickness of the layers. Sputtering at 300 mA for 160 s led to a Cu film thickness of 20 nm (100 Cu layers) containing 0.209% (wt/wt) polyester. The viability of MRSA strain ATCC 43300 on Cu-sputtered polyester was evaluated by four methods: (i) mechanical detachment, (ii) microcalorimetry, (iii) direct transfer onto plates, and (iv) stereomicroscopy. The low efficacy of mechanical detachment impeded bacterial viability estimations. Microcalorimetry provided only semiquantitative results. Direct transfer onto plates and stereomicroscopy seemed to be the most suitable methods to evaluate the bacterial inactivation potential of Cu-sputtered polyester surfaces, since they presented the least experimental bias. Cu-polyester samples sputtered for 160 s by DCMS were further tested against 10 clinical MRSA isolates and showed a high level of bactericidal activity, with a 4-log(10) reduction in the initial MRSA load (10(6) CFU) within 1 h. Cu-sputtered polyester surfaces might be of use to prevent the transmission of HCAI pathogens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study verifies whether cochlear implants helps deaf adults to maintain or develop their professional occupations. Sixty-seven patients received a questionnaire concerning their professional activities before and after implantation. At the time of implantation 34 were professionally active. After the implantation 29 remained active, 4 of them reporting positive developments in their careers. Five patients became inactive. The previously inactive patients remained inactive. There was no difference in auditory performances between professionally active or inactive patients. Cochlear implants enable most implanted adults to maintain and even progress in their professions. However, deafness still represents an obstacle to social integration as inactive patients who searched for a job were rejected after the job interviews.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to assess the microbiology of food and hand contact surfaces in the retail environment and the potential for these surfaces to act as vehicles for the spread of foodborne pathogens. During the survey, 10 stores in the Republic of Ireland (ROI) were visited by student Environmental Health Officers (EHOs) who took swab samples from four surfaces: conveyor belts, long-life shopping bags, shopping trolley handles and keypads on card payment units. The swab samples were examined for the presence of the pathogens Salmonella, Campylobacter and Listeria. The Aerobic Colony Counts, as well as the levels of E. coli and Enterobacteriaceae, were also determined. In addition, structured questionnaires were used with retailers to establish the stores’ regimes for the cleaning of conveyor belts. Similarly, shoppers donating their long-life shopping bags for sampling were questioned about how they normally use these bags, and the results were compared with those from the microbiological survey. The results indicated that the hygiene of the surfaces sampled was good, with Salmonella, Campylobacter and Listeria not detected in any of the samples, and levels of both Enterobacteriaceae and E. coli were below the limits of detection in all but one sample. Aerobic Colony Counts varied but none of the results obtained would be deemed ‘unacceptable’ or ‘unsatisfactory’ under guidelines for ready-to-eat foods

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new and original reagent based on the use of highly fluorescent cadmium telluride (CdTe) quantum dots (QDs) in aqueous solution is proposed to detect weak fingermarks in blood on non-porous surfaces. To assess the efficiency of this approach, comparisons were performed with one of the most efficient blood reagents on non-porous surfaces, Acid Yellow 7 (AY7). To this end, four non-porous surfaces were studied, i.e. glass, transparent polypropylene, black polyethylene, and aluminium foil. To evaluate the sensitivity of both reagents, sets of depleted fingermarks were prepared, using the same finger, initially soaked with blood, which was then successively applied on the same surface without recharging it with blood or latent secretions. The successive marks were then cut in halves and the halves treated separately with each reagent. The results showed that QDs were equally efficient to AY7 on glass, polyethylene and polypropylene surfaces, and were superior to AY7 on aluminium. The use of QDs in new, sensitive and highly efficient latent and blood mark detection techniques appears highly promising. Health and safety issues related to the use of cadmium are also discussed. It is suggested that applying QDs in aqueous solution (and not as a dry dusting powder) considerably lowers the toxicity risks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mechanically ventilated patients in hospitals are subjected to an increased risk of acquiring nosocomial pneumonia that sometimes has a lethal outcome. One way to minimize the risk could be to make the surfaces on endotracheal tubes antibacterial. In this study, bacterial growth was inhibited or completely prevented by silver ions wet chemically and deposited onto the tube surface. Through the wet chemical treatment developed here, a surface precipitate was formed containing silver chloride and a silver stearate salt. The identity and morphology of the surface precipitate was studied using x-ray photoelectron spectroscopy, Fourier transform infrared spectroscopy, scanning electron microscopy, and x-ray powder diffraction. Leaching of silver ions into solution was examined, and bacterial growth on the treated surfaces was assayed using Pseudomonas aeruginosa wild type (PAO1) bacteria. Furthermore, the minimum inhibitory concentration of silver ions was determined in liquid- and solid-rich growth medium as 23 and 18 microM, respectively, for P. aeruginosa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The role of Propionibacterium acnes in acne and in a wide range of inflammatory diseases is well established. However, P. acnes is also responsible for infections involving implants. Prolonged aerobic and anaerobic agar cultures for 14 days and broth cultures increase the detection rate. In this paper, we review the pathogenic role of P. acnes in implant-associated infections such as prosthetic joints, cardiac devices, breast implants, intraocular lenses, neurosurgical devices, and spine implants. The management of severe infections caused by P. acnes involves a combination of antimicrobial and surgical treatment (often removal of the device). Intravenous penicillin G and ceftriaxone are the first choice for serious infections, with vancomycin and daptomycin as alternatives, and amoxicillin, rifampicin, clindamycin, tetracycline, and levofloxacin for oral treatment. Sonication of explanted prosthetic material improves the diagnosis of implant-associated infections. Molecular methods may further increase the sensitivity of P. acnes detection. Coating of implants with antimicrobial substances could avoid or limit colonization of the surface and thereby reduce the risk of biofilm formation during severe infections. Our understanding of the role of P. acnes in human diseases will likely continue to increase as new associations and pathogenic mechanisms are discovered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:  Study in vivo characteristics of a polymethylmethacrylate (PMMA) implant compared to the standard cylindrical collagen implant for deep sclerectomy (DS). Design:  Six-month comparative study. Samples:  Twenty eyes of ten rabbits. Methods:  Eyes were randomized to have DS with PMMA implant in one eye and collagen implant in the opposite eye. The growth of the new subconjunctival drainage vessels was assessed by combined fluorescein and indocyanin green anterior segment angiography; intrascleral and subconjunctival blebs were imaged by ultrasound biomicroscopy (UBM). At six months, outflow facility (C) was measured by anterior chamber perfusion and portions of one side of the DS were compared to portions on the 180° opposite side and native sclera on histology. Results:  The mean IOP preoperatively and at one, four, twelve, and twenty-four weeks was comparable in both groups (P > 0.1). UBM showed a statistically insignificant quicker regression of the subconjunctival bleb as well as a durable intrascleral lake in the PMMA group (P > 0.05). New drainage vessels were initially observed one month after surgery; they were more numerous in the PMMA group on angiographic and histological findings at 6 months (P < 0.05). The mean C increased significantly after surgery compared to preoperative values (P < 0.05) and no difference was observed between the implants (0.24 ± 0.06 µl/min/mmHg [PMMA] and 0.23 ± 0.07 µl/min/mmHg [collagen implant]) (P = 0.39). Conclusions:  Deep sclerectomy performed with PMMA or collagen implants showed similar IOP lowering effects, outflow facility increase, and degree of inflammatory reaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

At mucosal surfaces, secretory IgA (SIgA) antibodies serve as the first line of defense against microorganisms through a mechanism called immune exclusion that prevents interaction of neutralized antigens with the epithelium. In addition, SIgA plays a role in the immune balance of the epithelial barrier through selective adhesion to M cells in intestinal Peyer's patches. This mediates the transepithelial retro-transport of the antibody and associated antigens from the intestinal lumen to underlying gut-associated organized lymphoid tissue. In Peyer's patches, SIgA-based immune complexes are internalized by underlying antigen-presenting cells, leaving the antigen with masked epitopes, a form that limits the risk of overwhelming the local immune protection system with danger signals. This translates into the onset of mucosal and systemic responses associated with production of anti-inflammatory cytokines and limited activation of antigen-presenting cells. In the gastrointestinal tract, SIgA exhibits thus properties of a neutralizing agent (immune exclusion) and of an immunopotentiator inducing effector immune responses in a noninflammatory context favorable to preserve local homeostasis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main result of this work is a parametric description of the spectral surfaces of a class of periodic 5-diagonal matrices, related to the strong moment problem. This class is a self-adjoint twin of the class of CMV matrices. Jointly they form the simplest possible classes of 5-diagonal matrices.