949 resultados para High frequency analog operation
Resumo:
Frequency, recency, and type of prior exposure to very low-and high-frequency words were manipulated in a 3-phase (i.e., familiarization training, study, and test) design. Increasing the frequency with which a definition for a very low-frequency word was provided during familiarization facilitated the word's recognition in both yes-no (Experiment 1) and forced-choice paradigms (Experiment 2). Recognition of very low-frequency words not accompanied by a definition during familiarization first increased, then decreased as familiarization frequency increased (Experiment I). Reasons for these differences were investigated in Experiment 3 using judgments of recency and frequency. Results suggested that prior familiarization of a very low-frequency word with its definition may allow a more adequate episodic representation of the word to be formed during a subsequent study trial. Theoretical implications of these results for current models of memory are discussed.
Resumo:
In this article we report on progress in high magnetic field MRI at the University of Florida in support of our new 750MHz wide bore and 11.7T/40cm MR instruments. The primary emphasis is on the associated rf technology required, particularly high frequency volume and phased array coils. Preliminary imaging results at 750MHz are presented. Our results imply that the pursuit of even higher fields seems warranted. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
Restricted cochlear lesions in adult animals result in plastic changes in the representation of the lesioned cochlea, and thus in the frequency map, in the contralateral auditory cortex and thalamus. To examine the contribution of subthalamic changes to this reorganization, the effects of unilateral mechanical cochlear lesions on the frequency organization of the central nucleus of the inferior colliculus (ICC) were examined in adult cats. Lesions typically resulted in a broad high-frequency hearing loss extending from a frequency in the range 15-22 kHz. After recovery periods of 2.5-18 months, the frequency organization of ICC contralateral to the lesioned cochlea was determined separately for the onset and late components of multiunit responses to tone-burst stimuli. For the late response component in all but one penetration through the ICC, and for the onset response component in more than half of the penetrations, changes in frequency organization in the lesion projection zone were explicable as the residue of prelesion responses. In half of the penetrations exhibiting nonresidue type changes in onset-response frequency organization, the changes appeared to reflect the unmasking of normally inhibited inputs. In the other half it was unclear whether the changes reflected unmasking or a dynamic process of reorganization. Thus, most of the observed changes were explicable as passive consequences of the lesion, and there was limited evidence for plasticity in the ICC. The implications of the data with respect to the primary locus of the changes and to the manner in which they contribute to thalamocortical reorganization are considered. (C) 2003 Wiley-Liss, Inc.
Resumo:
In order to separate the effects of experience from other characteristics of word frequency (e.g., orthographic distinctiveness), computer science and psychology students rated their experience with computer science technical items and nontechnical items from a wide range of word frequencies prior to being tested for recognition memory of the rated items. For nontechnical items, there was a curvilinear relationship between recognition accuracy and word frequency for both groups of students. The usual superiority of low-frequency words was demonstrated and high-frequency words were recognized least well. For technical items, a similar curvilinear relationship was evident for the psychology students, but for the computer science students, recognition accuracy was inversely related to word frequency. The ratings data showed that subjective experience rather than background word frequency was the better predictor of recognition accuracy.
Resumo:
Neste trabalho pretende-se estudar, dimensionar e implementar experimentalmente de um sistema de alimentação para transformadores de alta tensão a alta frequência. Este sistema será constituído por dois elementos principais, um rectificador monofásico em ponte totalmente controlado e por um inversor de tensão. Inicialmente realizou-se um estudo sobre as diferentes topologias possíveis para o rectificador considerando diferentes tipos de carga. Realizou-se, também, um estudo sobre o circuito de geração dos impulsos de disparo dos tiristores, executado com base num circuito integrado TCA 785, dimensionou-se os elementos constituintes do circuito de disparo, e de um sistema de controlo da tensão de saída do rectificador. Posteriormente estudou-se o funcionamento do inversor de tensão, definindo-se os modos de operação e dimensionou-se um circuito ressonante tendo em conta os parâmetros construtivos do transformador que se pretende utilizar. Finalmente procedeu-se à implementação prática dos sistemas previamente dimensionados e simulados e à apresentação dos respectivos resultados.
Resumo:
Mestrado em Engenharia Electrotécnica e de Computadores
Resumo:
This paper presents the design and compares the performance of linear, decoupled and direct power controllers (DPC) for three-phase matrix converters operating as unified power flow controllers (UPFC). A simplified steady-state model of the matrix converter-based UPFC fitted with a modified Venturini high-frequency pulse width modulator is first used to design the linear controllers for the transmission line active (P) and reactive (Q) powers. In order to minimize the resulting cross coupling between P and Q power controllers, decoupled linear controllers (DLC) are synthesized using inverse dynamics linearization. DPC are then developed using sliding-mode control techniques, in order to guarantee both robustness and decoupled control. The designed P and Q power controllers are compared using simulations and experimental results. Linear controllers show acceptable steady-state behaviour but still exhibit coupling between P and Q powers in transient operation. DLC are free from cross coupling but are parameter sensitive. Results obtained by DPC show decoupled power control with zero error tracking and faster responses with no overshoot and no steady-state error. All the designed controllers were implemented using the same digital signal processing hardware.
Resumo:
A dificuldade de controlo de um motor de indução, bem como o armazenamento de energia CC e posterior utilização como energia alternada promoveram o desenvolvimento de variadores de frequência e inversores. Assim, como projeto de tese de mestrado em Automação e Sistemas surge o desenvolvimento de um variador de frequência. Para elaboração do variador de frequência efetuou-se um estudo sobre as técnicas de modulação utilizadas nos inversores. A técnica escolhida e utilizada é a Sinusoidal Pulse Width Modulation (SPWM). Esta técnica baseia-se na modelação por largura de impulso (PWM), o qual é formado por comparação de um sinal de referência com um sinal de portadora de elevada frequência. Por sua vez, a topologia escolhida para o inversor corresponde a um Voltage Source Inverter (VSI) de ponte trifásica completa a três terminais. O desenvolvimento da técnica de modulação SPWM levou ao desenvolvimento de um modelo de simulação em SIMULINK, o qual permitiu retirar conclusões sobre os resultados obtidos. Na fase de implementação, foram desenvolvidas placas para o funcionamento do variador de frequência. Assim, numa fase inicial foi desenvolvida a placa de controlo, a qual contém a unidade de processamento e que é responsável pela atuação de Insulated Gate Bipolar Transistors (IGBTs). Para além disso, foi desenvolvida uma placa para proteção dos IGBTs (evitando condução simultânea no mesmo terminal) e uma placa de fontes isoladas para alimentação dos circuitos e para atuação dos IGBTs. Ainda, foi desenvolvida a técnica de SPWM em software para a unidade de controlo e finalmente foi desenvolvida uma interface gráfica para interação com o utilizador. A validação do projeto foi conseguida através da variação da velocidade do motor de indução trifásico. Para isso, este foi colocado a funcionar a diversas frequências de funcionamento e a diferentes amplitudes. Para além disso, o seu funcionamento foi também validado utilizando uma carga trifásica equilibrada de 3 lâmpadas de forma a ser visualizada a variação de frequência e variação de amplitude.
Resumo:
In August 1983,85 inhabitants of the municipality of Humaitá, Amazonas State, Brazil were studied to determine the prevalence of antigens to HLA-A, -B, -C and DR. Thirty-eight were sick with malaria due to Plasmodium falciparum. All subjects were examined for splenomegaly, blood parasitaemia and antibodies to malaria. They constituted three groups: 1) 25 subjects native to the Amazon region who had never had malaria; 2) 38 Amazonian subjects who had malaria in the past or currently had an infection; 3) 22 patients with malaria who had acquired the infection in the Amazon Region but came from other regions of Brazil. Blood was taken from each person, the lymphocytes were separated and typed by the test of microlymphocytotoxicity. There was a high frequency of antigens that could not be identified in the groups studied which suggests the existence of a homozygote or phenotype not identified in the population. There was a high frequency of the phenotype Ag(W24) (44.7%) in group 2 when compared with group 1 (32%) or group 3 (9%). Also the individuals in group 2 showed an elevated frequency of antigen DR(4)80%) when compared with group 1 (36.6%) or group 3 (16.6%). These observations suggest the possibility of a genetic susceptibility to malaria among Amazonian residents and indicate a necessity for more extensive studies of the frequency of HLA antigens among inhabitants of this endemic malarial zone.
Resumo:
The frequency of myocarditis associated with meningococcal disease in children was reported only in two autopsied series (United States and South Africa). Here we report the frequency of associated myocarditis in 31 children who died of meningoccal infection at Hospital Infantil N.S. da Glória in Vitória, Espirito Santo State, Brazil. The diagnosis was confirmed by isolation of Neisseria meningitidis . At least three sections of fragments of both atria and ventricles were studied using the Dallas Criteria for the morphologic diagnosis of myocarditis. The mean age was 47.6 ± 39.8 months and the mean survival time after the onset of symptoms was 46.1 ± 26.5h (12-112h). Myocarditis was present in 13 (41.9%) patients, being of minimal severity in 11 cases and of moderate severity in 2 cases. There were no cases with severe diffuse myocarditis. The frequency of myocarditis was not influenced by sex, presence of meningitis, survival time after the onset of symptoms or use of vasoactive drugs. The frequency of myocarditis reported here was intermediate between the values reported in the only two case series published in the literature (57% in the United States and 27% in South Africa). Although our data confirm the high frequency of myocaditis in meningoccal disease, further investigations are necessary to elucidate the contribution of myocarditis to myocardial dysfunction observed in cases of meningococcal infection in children.
Resumo:
INTRODUCTION: Ascaris lumbricoides-infected patients present lower prevalence of severe atopic dermatitis. METHODS: Peripheral blood of infected children with atopic dermatitis was assessed by flow cytometry of the frequency of Th1 and Th2 cells through the expression of CXCR3 and CCR4 chemokine receptors, respectively. RESULTS: Helminth-free patients with atopic dermatitis presented a high frequency of CCR4+Th2 cells. Parasitized patients with atopic dermatitis showed a lower frequency of CXCR3+Th1 cells compared to infected individuals only. CONCLUSIONS: Ascariasis modifies the blood traffic of Th2 cells in atopic dermatitis patients, while the allergic disease down-regulates the traffic of Th1 cells in parasitized patients.
Resumo:
Quadrature oscillators are key elements in modern radio frequency (RF) transceivers and very useful nowadays in wireless communications, since they can provide: low quadrature error, low phase-noise, and wide tuning range (useful to cover several bands). RC oscillators can be fully integrated without the need of external components (external high Q-inductors), optimizing area, cost, and power consumption. The conventional structure of ring oscillator offers poor frequency stability and phasenoise, low quality factor (Q), and besides being vulnerable to process, voltage and temperature (PVT) variations, its performance degrades as the frequency of operation increases. This thesis is devoted to quadrature oscillators and presents a detailed comparative study of ring oscillator and shift register (SR) approaches. It is shown that in SRs both phase-noise and phase error are reduced, while ring oscillators have the advantage of occupying less area and less consumption due to the reduced number of components in the circuit. Thus, although ring oscillators are more suitable for biomedical applications, SRs are more appropriate for wireless applications, especially when specification requirements are more stringent and demanding. The first architecture studied consists in a simple CMOS ring oscillator employing an odd number of static single-ended inverters as delay cells. Subsequently, the quadrature 4-stage ring oscillator concept is shown and post-layout simulations are presented. The 3 and 4-phase single-frequency local oscillator (LO) generators employing SRs are presented, the latter with 50% and 25% duty-cycles. The circuits operate at 600 MHz and 900 MHz, and were designed in a 130 nm standard CMOS technology with a voltage supply of 1.2 V.
Resumo:
Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Eletrónica Médica)
Resumo:
High-risk human papillomavirus (hrHPV) is an essential cause of cervical carcinoma and is also strongly related to anal cancer development. The hrHPV E6 oncoprotein plays a major role in carcinogenesis. We aimed to evaluate the frequency of hrHPV DNA and E6 oncoprotein in the anuses of women with cervical carcinoma. We analyzed 117 women with cervical cancer and 103 controls for hrHPV and the E6 oncogene. Positive test results for a cervical carcinoma included 66.7 % with hrHPV-16 and 7.7 % with hrHPV-18. One case tested positive for both HPV variants (0.9 %). The samples from the anal canal were positive for HPV-16 in 59.8 % of the cases. Simultaneous presence of HPV in the cervix and anal canal was found in 53.8 % of the cases. Regarding expression of E6 RNA, positivity for HPV-16 in the anal canal was found in 21.2 % of the cases, positivity for HPV-16 in the cervix was found in 75.0 %, and positivity for HPV-18 in the cervix was found in 1.9 %. E6 expression in both the cervix and anal canal was found in 19.2 % of the cases. In the controls, 1 % tested positive for HPV-16 and 0 % for HPV-18. Anal samples from the controls showed a hrHPV frequency of 4.9 % (only HPV16). The presence of hrHPV in the anal canal of women with cervical cancer was detected at a high frequency. We also detected E6 RNA expression in the anal canal of women with cervical cancer, suggesting that these women are at risk for anal hrHPV infection.
Resumo:
En la actualidad, la gran cantidad de aplicaciones que surgen dentro del ámbito de la radiofrecuencia hacen que el desarrollo de dispositivos dentro de este campo sea constante. Estos dispositivos cada vez requieren mayor potencia para frecuencias de trabajo elevadas, lo que sugiere abrir vías de investigación sobre dispositivos de potencia que ofrezcan los resultados deseados para altas frecuencias de operación (GHz). Dentro de este ámbito, el objetivo principal de este proyecto es el de realizar un estudio sobre este tipo de dispositivos, siendo el transistor LDMOS el candidato elegido para tal efecto, debido a su buen comportamiento en frecuencia para tensiones elevadas de funcionamiento.