869 resultados para HISTOPATHOLOGIC VALIDATION
Resumo:
This study examined the validity and reliability of the French version of two observer-rated measures developed to assess cognitive errors (cognitive errors rating system [CERS]) [6] and coping action patterns (coping action patterns rating system [CAPRS]) [22,24]. The CE measures 14 cognitive errors, broken down according to their valence positive or negative (see the definitions by A.T. Beck), and the CAP measures 12 coping categories, based on an comprehensive review literature, each broken down into three levels of action (affective, behavioural, cognitive). Thirty (N = 30) subjects recruited in a community sample participated in the study. They were interviewed according to a standardized clinical protocol: these interviews were transcribed and analysed with both observer-rated systems. Results showed that the inter-rater reliability of the two measures is good and that their internal validity is satisfactory, due to a non-significant canonical correlation between CAP and CE. With regard to discriminant validity, we found a non-significant canonical correlation between CAPRS and CISS, one of most widely used self-report questionnaire measuring coping. The same can be said for the correlation with a self-report questionnaire measuring symptoms (SCL-90-R). These results confirm the absence of confounds in the assessment of cognitive errors and of coping as assessed by these observer-rated scales and add an argument in favour of the French validation of the CE-CAP rating scales. (C) 2010 Elsevier Masson SAS. All rights reserved.
Resumo:
Background The PEmb-QoL is a validated 40-item questionnaire to quantify health-related quality of life in patients having experienced pulmonary embolism (PE). It covers six health dimensions: frequency of complaints, activities of daily living limitations, work-related problems, social limitations, intensity of complaints, and emotional complaints. Originally developed in Dutch and English, we sought to prospectively validate the psychometric properties of a French version of the PEmb-QoL.MethodsWe performed a forward and backward translation of the English version of the PEmb-QoL into French. French-speaking consecutive adult patients with an acute, objectively confirmed PE admitted to the emergency department of a Swiss university hospital between 08/2009 and 09/2011 were recruited telephonically. We used standard psychometric tests and criteria to evaluate the acceptability, reliability, and validity of the French version of the PEmb-QoL. We also performed an exploratory factor analysis.ResultsOverall, 102 patients were enrolled in the study. The French version of the PEmb-QoL showed good reliability (internal consistency, item¿total and inter-item correlations), reproducibility (test-retest reliability), and validity (convergent, discriminant) in French-speaking patients with PE. The exploratory factor analysis suggested three underlying dimensions: limitations in daily activity (items 4b-m, 5a-d), symptoms (items 1a-h and 7), and emotional complaints (items 9a-f and j).ConclusionWe successfully validated the French version of the PEmb-QoL questionnaire in patients with PE. Our results show that the PEmb-QoL is a valuable tool for assessing health-related quality of life after PE in French-speaking patients.
Resumo:
BACKGROUND: Practice guidelines for examining febrile patients presenting upon returning from the tropics were developed to assist primary care physicians in decision making. Because of the low level of evidence available in this field, there was a need to validate them and assess their feasibility in the context they have been designed for. OBJECTIVES: The objectives of the study were to (1) evaluate physicians' adherence to recommendations; (2) investigate reasons for non-adherence; and (3) ensure good clinical outcome of patients, the ultimate goal being to improve the quality of the guidelines, in particular to tailor them for the needs of the target audience and population. METHODS: Physicians consulting the guidelines on the Internet (www.fevertravel.ch) were invited to participate in the study. Navigation through the decision chart was automatically recorded, including diagnostic tests performed, initial and final diagnoses, and clinical outcomes. The reasons for non-adherence were investigated and qualitative feedback was collected. RESULTS: A total of 539 physician/patient pairs were included in this study. Full adherence to guidelines was observed in 29% of the cases. Figure-specific adherence rate was 54.8%. The main reasons for non-adherence were as follows: no repetition of malaria tests (111/352) and no presumptive antibiotic treatment for febrile diarrhea (64/153) or abdominal pain without leukocytosis (46/101). Overall, 20% of diversions from guidelines were considered reasonable because there was an alternative presumptive diagnosis or the symptoms were mild, which means that the corrected adherence rate per case was 40.6% and corrected adherence per figure was 61.7%. No death was recorded and all complications could be attributed to the underlying illness rather than to adherence to guidelines. CONCLUSIONS: These guidelines proved to be feasible, useful, and leading to good clinical outcomes. Almost one third of physicians strictly adhered to the guidelines. Other physicians used the guidelines not to forget specific diagnoses but finally diverged from the proposed attitudes. These diversions should be scrutinized for further refinement of the guidelines to better fit to physician and patient needs.
Resumo:
Conventional methods of gene prediction rely on the recognition of DNA-sequence signals, the coding potential or the comparison of a genomic sequence with a cDNA, EST, or protein database. Reasons for limited accuracy in many circumstances are species-specific training and the incompleteness of reference databases. Lately, comparative genome analysis has attracted increasing attention. Several analysis tools that are based on human/mouse comparisons are already available. Here, we present a program for the prediction of protein-coding genes, termed SGP-1 (Syntenic Gene Prediction), which is based on the similarity of homologous genomic sequences. In contrast to most existing tools, the accuracy of SGP-1 depends little on species-specific properties such as codon usage or the nucleotide distribution. SGP-1 may therefore be applied to nonstandard model organisms in vertebrates as well as in plants, without the need for extensive parameter training. In addition to predicting genes in large-scale genomic sequences, the program may be useful to validate gene structure annotations from databases. To this end, SGP-1 output also contains comparisons between predicted and annotated gene structures in HTML format. The program can be accessed via a Web server at http://soft.ice.mpg.de/sgp-1. The source code, written in ANSI C, is available on request from the authors.
Resumo:
Descriptors based on Molecular Interaction Fields (MIF) are highly suitable for drug discovery, but their size (thousands of variables) often limits their application in practice. Here we describe a simple and fast computational method that extracts from a MIF a handful of highly informative points (hot spots) which summarize the most relevant information. The method was specifically developed for drug discovery, is fast, and does not require human supervision, being suitable for its application on very large series of compounds. The quality of the results has been tested by running the method on the ligand structure of a large number of ligand-receptor complexes and then comparing the position of the selected hot spots with actual atoms of the receptor. As an additional test, the hot spots obtained with the novel method were used to obtain GRIND-like molecular descriptors which were compared with the original GRIND. In both cases the results show that the novel method is highly suitable for describing ligand-receptor interactions and compares favorably with other state-of-the-art methods.
Resumo:
PURPOSE: Cardiovascular magnetic resonance (CMR) has become a robust and important diagnostic imaging modality in cardiovascular medicine. However,insufficient image quality may compromise its diagnostic accuracy. No standardized criteria are available to assess the quality of CMR studies. We aimed todescribe and validate standardized criteria to evaluate the quality of CMR studies including: a) cine steady-state free precession, b) delayed gadoliniumenhancement, and c) adenosine stress first-pass perfusion. These criteria will serve for the assessment of the image quality in the setting of the Euro-CMR registry.METHOD AND MATERIALS: First, a total of 45 quality criteria were defined (35 qualitative criteria with a score from 0-3, and 10 quantitative criteria). Thequalitative score ranged from 0 to 105. The lower the qualitative score, the better the quality. The quantitative criteria were based on the absolute signal intensity (delayed enhancement) and on the signal increase (perfusion) of the anterior/posterior left ventricular wall after gadolinium injection. These criteria were then applied in 30 patients scanned with a 1.5T system and in 15 patients scanned with a 3.0T system. The examinations were jointly interpreted by 3 CMR experts and 1 study nurse. In these 45 patients the correlation between the results of the quality assessment obtained by the different readers was calculated.RESULTS: On the 1.5T machine, the mean quality score was 3.5. The mean difference between each pair of observers was 0.2 (5.7%) with a mean standarddeviation of 1.4. On the 3.0T machine, the mean quality score was 4.4. The mean difference between each pair of onservers was 0.3 (6.4%) with a meanstandard deviation of 1.6. The quantitative quality assessments between observers were well correlated for the 1.5T machine: R was between 0.78 and 0.99 (pCONCLUSION: The described criteria for the assessment of CMR image quality are robust and have a low inter-observer variability, especially on 1.5T systems.CLINICAL RELEVANCE/APPLICATION: These criteria will allow the standardization of CMR examinations. They will help to improve the overall quality ofexaminations and the comparison between clinical studies.
Resumo:
INTRODUCTION: Anhedonia is defined as a diminished capacity to experience pleasant emotion and is commonly included among the negative symptoms of schizophrenia. However, if patients report experiencing a lower level of pleasure than controls, they report experiencing as much pleasure as controls with online measurements of emotion. OBJECTIVE: The Temporal Experience of Pleasure Scale (TEPS) measures pleasure experienced in the moment and in anticipation of future activities. The TEPS is an 18-item self-report measurement of anticipatory (10 items) and consummatory (eight items) pleasure. The goal of this paper is to assess the psychometric characteristics of the French translation of this scale. METHODS: A control sample was composed of 60 women and 22 men, with a mean age of 38.1 years (S.D.: 10.8). Thirty-six were without qualification and 46 with qualified professional diploma. A sample of 21 patients meeting DSM IV-TR criteria for schizophrenia was recruited among the community psychiatry service of the department of psychiatry in Lausanne. They were five women and 16 men; mean age was of 34.1 years (S.D.: 7.5). Ten obtained a professional qualification and 11 were without qualification. None worked in competitive employment. Their mean dose of chlorpromazine equivalent was 431mg (S.D.: 259). All patients were on atypical antipsychotics. The control sample fulfilled the TEPS and the Physical Anhedonia Scale (PAS). The patient sample fulfilled the TEPS and was independently rated on the Calgary Depression Scale and the Scale for Assessment of Negative Symptoms. For comparison with controls, patients were matched on age, sex and professional qualification. This required the supplementary recruitment of two control subjects. RESULTS: Results with the control sample indicate that the TEPS presents an acceptable internal validity with Crombach alphas of 0.84 for the total scale, 0.74 for the anticipatory pleasure scale and 0.79 for the consummatory pleasure scale. The confirmatory factor analysis indicated that the model is well adapted to our data (chi(2)/dl=1.333; df=134; p<0.0006; root mean square residual, RMSEA=0.064). External validity measured with the PAS showed R=-0.27 (p<0.05) for the consummatory scale and R=-0.26 for the total score. Comparisons between patients and matched controls indicated that patients were significantly lower than control on anticipatory pleasure (t=2.7, df(40), 2-tailed p=0.01; cohen's d=0.83) and on total score of the TEPS (t=2.8, df (40), 2-tailed p=0.01; cohen's d=0.87). The two samples did not differ on consummatory pleasure. The anticipatory pleasure factor and the total TEPS showed significant negative correlation with the SANS anhedonia, respectively R=-0.78 (p<0.01) for the anticipatory factor and R=-0.61 (p<0.01) for the total TEPS. There was also a negative correlation between the anticipatory factor and the SANS avolition of R=-0.50 (p<0.05). These correlations were maintained, with partial correlations controlling for depression and chlorpromazine equivalents. CONCLUSION: The results of this validation show that the French version of the TEPS has psychometric characteristics similar to the original version. These results highlight the discrepancy between results of direct or indirect report of experienced pleasure in patients with schizophrenia. Patients may have difficulties in anticipating the pleasure of future enjoyable activities, but not in experiencing pleasure once in an enjoyable activity. Medication and depression do not seems to modify our results, but this should be better controlled in a longitudinal study. The anticipatory versus consummatory pleasure distinction appears to be useful for the development of new psychosocial interventions, tailored to improve desire in patients suffering from schizophrenia. Major limitations of the study are the small size of patient sample and the under representation of men in the control sample.
Resumo:
A validation study has been performed using the Soil and Water Assessment Tool (SWAT) model with data collected for the Upper Maquoketa River Watershed (UMRW), which drains over 16,000 ha in northeast Iowa. This validation assessment builds on a previous study with nested modeling for the UMRW that required both the Agricultural Policy EXtender (APEX) model and SWAT. In the nested modeling approach, edge-offield flows and pollutant load estimates were generated for manure application fields with APEX and were then subsequently routed to the watershed outlet in SWAT, along with flows and pollutant loadings estimated for the rest of the watershed routed to the watershed outlet. In the current study, the entire UMRW cropland area was simulated in SWAT, which required translating the APEX subareas into SWAT hydrologic response units (HRUs). Calibration and validation of the SWAT output was performed by comparing predicted flow and NO3-N loadings with corresponding in-stream measurements at the watershed outlet from 1999 to 2001. Annual stream flows measured at the watershed outlet were greatly under-predicted when precipitation data collected within the watershed during the 1999-2001 period were used to drive SWAT. Selection of alternative climate data resulted in greatly improved average annual stream predictions, and also relatively strong r2 values of 0.73 and 0.72 for the predicted average monthly flows and NO3-N loads, respectively. The impact of alternative precipitation data shows that as average annual precipitation increases 19%, the relative change in average annual streamflow is about 55%. In summary, the results of this study show that SWAT can replicate measured trends for this watershed and that climate inputs are very important for validating SWAT and other water quality models.
Resumo:
(from the journal abstract) Objectives: The birth of a high risk infant--such as a very or extremely premature infant--can represent an important traumatic experience for parents. R. DeMier, M. Hynan et al's "Perinatal PTSD Questionnaire" aims at exploring, retrospectively, parent's posttraumatic stress reactions following the birth of a high risk infant. This paper describes the French validation of this questionnaire. Methods: Fifty-two families with a very or extremely premature infant and 25 families with a full term infant responded to the "Perinatal PTSD Questionnaire" and the "Impact of Event Scale" when children were 18 months old. Results: Parents of high risk infants can present posttraumatic stress reactions such as intrusion, avoidance or arousal symptoms. The French version of the "Perinatal PTSD Questionnaire" has satisfactory psychometric properties. Conclusions: As posttraumatic reactions are not directly related to objective descriptions of the stressful event, it may be essential to the liaison child psychiatrist to consider individual posttraumatic reactions in order to optimise preventive intervention with the parents. A questionnaire should not replace a clinical interview, however it may represent a useful screening tool. Also, this questionnaire should be useful for research purposes. (PsycINFO Database Record (c) 2005 APA, all rights reserved)
Resumo:
BACKGROUND: To perform a comprehensive study on the relationship between vitamin D metabolism and the response to interferon-α-based therapy of chronic hepatitis C. METHODOLOGY/PRINCIPAL FINDINGS: Associations between a functionally relevant polymorphism in the gene encoding the vitamin D 1α-hydroxylase (CYP27B1-1260 rs10877012) and the response to treatment with pegylated interferon-α (PEG-IFN-α) and ribavirin were determined in 701 patients with chronic hepatitis C. In addition, associations between serum concentrations of 25-hydroxyvitamin D(3) (25[OH]D(3)) and treatment outcome were analysed. CYP27B1-1260 rs10877012 was found to be an independent predictor of sustained virologic response (SVR) in patients with poor-response IL28B genotypes (15% difference in SVR for rs10877012 genotype AA vs. CC, p = 0.02, OR = 1.52, 95% CI = 1.061-2.188), but not in patients with favourable IL28B genotype. Patients with chronic hepatitis C showed a high prevalence of vitamin D insufficiency (25[OH]D(3)<20 ng/mL) during all seasons, but 25(OH)D(3) serum levels were not associated with treatment outcome. CONCLUSIONS/SIGNIFICANCE: Our study suggests a role of bioactive vitamin D (1,25[OH](2)D(3), calcitriol) in the response to treatment of chronic hepatitis C. However, serum concentration of the calcitriol precursor 25(OH)D(3) is not a suitable predictor of treatment outcome.
Resumo:
Recently published criteria using clinical (ataxia or asymmetrical distribution at onset or full development, and sensory loss not restricted to the lower limbs) and electrophysiological items (less than two abnormal lower limb motor nerves and at least an abolished SAP or three SAP below 30% of lower limit of normal in the upper limbs) were sensitive and specific for the diagnosis of sensory neuronopathy (SNN) (Camdessanche et al., Brain, 2009). However, these criteria need to be validated on a large multicenter population. For this, a database collecting cases from fifteen Reference Centers for Neuromuscular diseases in France and Switzerland is currently developed. So far, data from 120 patients with clinically pure sensory neuropathy have been collected. Cases were classified independently from the evaluated criteria as SNN (53), non-SNN (46) or suspected SNN (21) according to the expert's diagnosis. Using the criteria, SNN was possible in 83% (44/53), 23.9% (11/46) and 71.4% (15/21) of cases, respectively. In the non-SSN group, half of the patients with a diagnosis of possible SSN had an ataxic form of inflammatory demyelinating neuropathy. In the SNN group, half of those not retained as possible SNN had CANOMAD, paraneoplasia, or B12 deficiency. In a second step, after application of the items necessary to reach the level of probable SNN (no biological or electrophysiological abnormalities excluding SNN; presence of onconeural antibody, cisplatin treatment, Sj ¨ ogren's syndrome or spinal cord MRI high signal in the posterior column), a final diagnosis of possible or probable SNN was obtained in, respectively, 90.6% (48/53), 8.8% (4/45), and 71.4% (15/21) of patients in the three groups. Among the 5 patients with a final non-SNN but initial SNN diagnosis, 3 had motor conduction abnormalities (one with CANOMAD) and among the 4 patients with a final SNN but initial non-SSN diagnosis, one had anti-Hu antibody and one was discussed as a possible ataxic CIDP. These preliminary results confirm the sensitivity and specificity of the proposed criteria for the diagnosis of SNN.
Resumo:
OBJECTIVE: Evaluation of a French translation of the Addiction Severity Index (ASI) in 100 (78 male) alcoholic patients. METHOD: Validity of the instrument was assessed by measuring test-retest and interrater reliability, internal consistency and convergence and discrimination between items and scales. Concurrent validity was assessed by comparing the scores from the ASI with those obtained from three other clinimetric instruments. RESULTS: Test-retest reliability of ASI scores (after a 10-day interval) was good (r = 0.63 to r = 0.95). Interrater reliability was evaluated using six video recordings of patient interviews. Severity ratings assigned by six rates were significantly different (p < .05), but 72% of the ratings assigned by those who viewed the videos were within two points of the interviewer's severity ratings. Cronbach alpha coefficient of internal consistency varied from 0.58 to 0.81 across scales. The average item-to-scale convergent validity (r value) was 0.49 (range 0.0 to 0.84) for composite scores and 0.35 (range 0.00 to 0.68) for severity ratings, whereas discriminant validity was 0.11 on average (range-0.19 to 0.46) for composite scores and 0.12 (range-0.20 to 0.52) for severity ratings. Finally, concurrent validity with the following instruments was assessed: Severity of Alcoholism Dependence Questionnaire (40% shared variance with ASI alcohol scale), Michigan Alcoholism Screening Test (2% shared variance with ASI alcohol scale) and Hamilton Depression Rating Scale (31% shared variance with ASI psychiatric scale). CONCLUSIONS: The Addiction Severity Index covers a large scope of problems encountered among alcoholics and quantifies need for treatment. This French version presents acceptable criteria of reliability and validity.
Resumo:
This study aimed to derive an index quantifying the state of alteration of cadavers by quantifying the presence of gas in the body using postmortem multidetector computed tomography (MDCT) imaging, and to validate the index by defining its sensitivity and specificity. The RA (radiological alteration)-index was derived from postmortem MDCT data from 118 nontraumatically deceased people. To validate the index, 100 additional scanned bodies (50 % traumatically deceased) were retrospectively examined by two independent observers. Presence of gas at 82 sites was assessed by a radiologist, whereas a forensic pathologist only investigated the seven sites used for the RA-index. The RA-index was highly correlated to the overall presence of gas in all 82 sites (R(2) = 0.98 in the derivation set and 0.85 in the validation set). Semiquantitative evaluation of gas presence in each site showed moderate reliability (Cohen's kappa range, 0.41-0.78); nevertheless, the overall RA-index was very reliable (ICC(2,1) = 0.95; 95 % CI 0.92-0.96). Examiner using the RA-index detected heart cavities full of gas with a sensitivity of 100 % (95 % CI 51.7-100) and a specificity of 98.8 % (92.6-99.9). We conclude that determining the presence of gas at seven sites is a valid means to measure the distribution of gas due to cadaveric alteration in the entire body. The RA-index is rapid, easy-to-use, and reliable for nonexperienced users, and it is a valid method to suspect the normal presence of gas from cadaveric alteration. MDCT can be used to screen for gas embolism and to give indications for gas composition analysis (gas chromatography).
Resumo:
Tumor Endothelial Marker-1 (TEM1/CD248) is a tumor vascular marker with high therapeutic and diagnostic potentials. Immuno-imaging with TEM1-specific antibodies can help to detect cancerous lesions, monitor tumor responses, and select patients that are most likely to benefit from TEM1-targeted therapies. In particular, near infrared(NIR) optical imaging with biomarker-specific antibodies can provide real-time, tomographic information without exposing the subjects to radioactivity. To maximize the theranostic potential of TEM1, we developed a panel of all human, multivalent Fc-fusion proteins based on a previously identified single chain antibody (scFv78) that recognizes both human and mouse TEM1. By characterizing avidity, stability, and pharmacokinectics, we identified one fusion protein, 78Fc, with desirable characteristics for immuno-imaging applications. The biodistribution of radiolabeled 78Fc showed that this antibody had minimal binding to normal organs, which have low expression of TEM1. Next, we developed a 78Fc-based tracer and tested its performance in different TEM1-expressing mouse models. The NIR imaging and tomography results suggest that the 78Fc-NIR tracer performs well in distinguishing mouse- or human-TEM1 expressing tumor grafts from normal organs and control grafts in vivo. From these results we conclude that further development and optimization of 78Fc as a TEM1-targeted imaging agent for use in clinical settings is warranted.