885 resultados para Fuzzy Modelling, Short Circuit, GMAW-P, Welding, Gas Metal Arc Welding
Resumo:
The objective of the present work is develop a model to simulate electrical energy networks in transient and stead states, using the software ATP (Alternative Transient Program), able to be a way to join two distinct themes, present in classical methodology planning networks: short circuit analysis and load flow theory. Beyond that, using a tool for relay simulation, this paper intend to use the new developed model to investigate the influence of transient phenomenon in operation of protection relays, and calibrate the enterprise's protections relays. For testing the model, some relays, actually, installed at COSERN were used
Resumo:
This work has as main objective to show all the particularities regarding the Three-phase Power Summation Method, used for load flow calculation, in what it says respect to the influence of the magnetic coupling among the phases, as well as to the losses presented in all the existent transformers in the feeder to be analyzed. Besides, its application is detailed in the study of the short-circuits, that happen in the presence of high impedance values, which possess a problem, that is its difficult detection and consequent elimination on the part of common devices of protection. That happens due to the characteristic presented by the current of short¬ circuit, in being generally of the same order of greatness that the load currents. Results of simulations accomplished in several situations will be shown, objectifying a complete analysis of the behavior of the proposed method in several types of short-circuits. Confront of the results obtained by the method with results of another works will be presented to verify its effectiveness
Resumo:
Low voltage solar panels increase the reliability of solar panels due to reduction of in series associations the configurations of photovoltaic cells. The low voltage generation requires DCDC converters devices with high efficiency, enabling raise and regulate the output voltage. This study analyzes the performance of a photovoltaic panel of Solarex, MSX model 77, configured to generate an open circuit voltage of 10.5 V, with load voltage of 8.5 V, with short circuit current of 9 A and a power of 77 W. The solar panel was assembled in the isolated photovoltaic system configuration, with and without energy storage as an interface with a DCDC converter, Booster topology. The converter was designed and fabricated using SMD (Surface Mounted Devices) technology IC (integrated circuit) that regulates its output voltage at 14.2 V, with an efficiency of 87% and providing the load a maximum power of 20.88 W. The system was installed and instrumented for measurement and acquisition of the following data: luminosities, average global radiation (data of INPE Instituto Nacional de Pesquisas Espaciais), solar panel and environment temperatures, solar panel and DC-DC converter output voltages, panel, inverter, and battery charge output currents. The photovoltaic system was initially tested in the laboratory (simulating its functioning in ideal conditions of operation) and then subjected to testing in real field conditions. The panel inclination angle was set at 5.5°, consistent with the latitude of Natal city. Factors such as climatic conditions (simultaneous variations of temperature, solar luminosities and ra diation on the panel), values of load resistance, lower limit of the maximum power required by the load (20.88 W) were predominant factors that panel does not operate with energy efficiency levels greater than 5 to 6%. The average converter efficiency designed in the field test reached 95%
Resumo:
The design of full programmable type-2 membership function circuit is presented in this paper. This circuit is used to implement the fuzzifier block of Type-2 Fuzzy Logic Controller chip. In this paper the type-2 fuzzy set was obtained by blurring the width of the type-1 fuzzy set. This circuit allows programming the height and the shape of the membership function. It operates in current mode, with supply voltage of 3.3V. The simulation results of interval type-2 membership function circuit have been done in CMOS 0.35μm technology using Mentor Graphics software. © 2011 IEEE.
Resumo:
The objective of this paper is to show a methodology to estimate transmission line parameters. The method is applied in a single-phase transmission line using the method of least squares. In this method the longitudinal and transversal parameters of the line are obtained as a function of a set of measurements of currents and voltages (as well as their derivatives with respect to time) at the terminals of the line during the occurrence of a short-circuit phase-ground near the load. The method is based on the assumption that a transmission line can be represented by a single circuit π. The results show that the precision of the method depends on the length of the line, where it has a better performance for short lines and medium length. © 2012 IEEE.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
A presente dissertação de mestrado avalia os afundamentos e a estabilidade de tensão de um sistema elétrico real com inserção de parques eólicos. Os estudos de afundamentos de tensão servem de base para a determinação das áreas de vulnerabilidade do sistema elétrico, nas quais, por sua vez, são investigados os aspectos referentes à instabilidade de tensão ocasionada pela integração de parques eólicos com geradores assíncronos. Para este fim, é utilizado o programa computacional ANAQUALI, desenvolvido pelo CEPEL (Centro de Pesquisas de Energia Elétrica). No estudo do comportamento dinâmico da tensão decorrente de curto-circuito, no qual o sistema eólico é inserido nas concepções de velocidade fixa e velocidade variável, utiliza-se um programa computacional desenvolvido no aplicativo MATLABTM. Os resultados dessas simulações evidenciam que o sistema eólico de velocidade variável proporciona uma maior margem de estabilidade de tensão ao sistema elétrico, devido à presença do controle de velocidade e de tensão. Estes estudos não são comumente aplicados aos sistemas de geração distribuída, e por isso, esta dissertação contribui também neste aspecto, podendo seus resultados servir de base para o planejamento de centrais cólicas inseridas em sistemas elétricos convencionais.
Resumo:
Aborda a classificação automática de faltas do tipo curto-circuito em linhas de transmissão. A maioria dos sistemas de transmissão possuem três fases (A, B e C). Por exemplo, um curto-circuito entre as fases A e B pode ser identicado como uma falta\AB". Considerando a possibilidade de um curto-circuito com a fase terra (T), a tarefa ao longo desse trabalho de classificar uma série temporal em uma das 11 faltas possíveis: AT, BT, CT, AB, AC, BC, ABC, ABT, ACT, BCT, ABCT. Estas faltas são responsáveis pela maioria dos distúrbios no sistema elétrico. Cada curto-circuito é representado por uma seqüência (série temporal) e ambos os tipos de classificação, on-line (para cada curto segmento extraído do sinal) e off-line (leva em consideração toda a seqüência), são investigados. Para evitar a atual falta de dados rotulados, o simulador Alternative Transient Program (ATP) é usado para criar uma base de dados rotulada e disponibilizada em domínio público. Alguns trabalhos na literatura não fazem distinção entre as faltas ABC e ABCT. Assim, resultados distinguindo esse dois tipos de faltas adotando técnicas de pré-processamento, diferentes front ends (por exemplo wavelets) e algoritmos de aprendizado (árvores de decisão e redes neurais) são apresentados. O custo computacional estimado durante o estágio de teste de alguns classificadores é investigado e a escolha dos parâmetros dos classificadores é feita a partir de uma seleção automática de modelo. Os resultados obtidos indicam que as árvores de decisão e as redes neurais apresentam melhores resultados quando comparados aos outros classificadores.