917 resultados para Experimental evaluation
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this paper is to compare the fluoride-releasing and mechanical properties of an experimental luting glass ionomer cement, which has a modified composition and a commercial luting cement. The experimental powder was obtained by sol-gel process and then, it was used to prepare the experimental cements. The properties of cement pastes, such as setting time and working time, microhardness and diametral tensile strength were determined. Fluoride release from GICs was evaluated at time intervals of 1, 7, 14, 21 and 28 days in deionized water. Atomic force microscopy (AFM) analyses showed that the surface of the experimental cements is more homogeneous than commercial GICs. The mechanical properties and the measure of liberation of fluoride of the two cements were influenced by ratio powder:liquid and chemical composition of the precursor powders. Experimental cements released less fluoride than commercial cements. However, this liberation was more constant during the analyzed period. Thus, the results obtained in this study indicated that the composition of the experimental powder modified by the niobium can lead the formation of the polysalt matrix with good mechanical properties. In other words, we can say that experimental powder offered considerable promise for exploitation in dental field.
Resumo:
Aim. The authors assess a modified Greenfield filter (GF) for the long-term patency, filter tilting and histopathologic alterations of the inferior vena cava (IVC).Methods. Adult sheep (n=7) underwent modified GF placement in the IVC. Cavograms were obtained every 3 months and pulmonary angiography at 12 months. Histopathologic and scanning electron microscopy (SEM) analyses were performed on the IVC explanted at 12 months.Results. Cavograms showed that all IVC were patent at the end of the study. Filter tilting occurred in 2/7 animals and extrusion of struts was not observed. Macroscopic examination at explantation showed minimal venous wall thickening. Microscopic examination showed minimal IVC fibrosis and intimal hyperplasia. SEM showed endothelium on the IVC surface at the filter implantation site and a presumed endothelial layer covering partially or totally the struts. The interface filter-IVC was covered by deposits of leucocytes and platelets. No signs of pulmonary embolism were found in all pulmonary angiograms of both groups.Conclusion. The modified filter presented good biocompatibility, stability and absence of thrombogenicity at 12 months. It presented low tendency to tilting and extrusion of struts. The long-term histopathologic alterations in vena caval wall were minimal and the appearance of the studied filters in the IVC was similar to stents placed in the arterial system.
Resumo:
Clinical parameters and biochemical and cellular changes in the plasma and peritoneal fluid were evaluated in horses after i.v. injection of a sub-lethal dose (50 ng/kg) of E. coli endotoxin. A significant decrease in the number of neutrophils and lymphocytes occurred in the blood 1h 15 min and 3 hours after injection of endotoxin; body temperature was increased significantly at the 3rd hour. No changes were detected in the total number of white blood cells in the peritoneal fluid. No significant differences in biochemical values were detected in either plasma or peritoneal fluid. Endotoxemia caused an alteration in blood cellularity, without effecting the peritoneal cellular population.
Resumo:
The present work evaluated histopathological aspects in experimental envenomation of dogs with Crotalus durissus terrificus venom. Twenty-eight mixed breed adult dogs were divided into three groups of seven animals each: Group I only venom; Group II - venom + 50ml antiophidic serum + fluid therapy; Group III venom + 50ml antiophidic serum + fluid therapy + urine alkalization. Lyophilized venom of Crotalus durissus terrificus was reconstituted in saline solution and inoculated subcutaneously at the dose of 1mg/kg body weight. Three animals of each group were subjected to euthanasia, and their muscular tissue, brain, spleen, kidneys, heart, lungs, stomach, small and large intestines, and popliteal lymph node fragments were collected for histopathological evaluation. There was myonecrosis in the inoculated limb, renal tubular degeneration, lymphoid hyperplasia of spleen, and unspecific reactive hepatitis. These results show the antigenicity and action of the venom on the immune system.
Resumo:
The exoantigen of Paracoccidioides brasiliensis standardized by Camargo et al. [1] (AgR) was used to evaluate the in vivo and in vitro cell immune response of experimental animals and of patients with paracoccidioidomycosis (PBM). Fava Netto antigen (AgF) was tested in parallel as a control antigen. The study was conducted with mice and guinea pigs infected with P. brasiliensis or immunized with its fungal antigens, on patients with PBM and on their respective control groups. The cell immune response was analysed by skin tests, and by the macrophage and leucocyte migration inhibition tests (MMIT and LMIT) in the animals and in the patients, respectively. The skin test with AgR as paracoccidioidin was positive in infected or immunized mice and guinea pigs and negative in control animals. The skin tests with AgR (24 h) showed 96.7% positivity in patients with PBM and were negative in control individuals. Histopathological study of the in vivo tests in the different experimental models was consistent with a delayed hypersensitivity response (DHR). Immunohistochemical study of the skin tests of PBM patients demonstrated a predominance of T lymphocytes, confirming the nature of a DHR to the fungal antigens. The in vitro cell immune response showed variable results for the various experimental models, i.e. significant rates of MMIT in immunized mice, a tendency to positivity in infected guinea pigs, and the absence of migration inhibition in PBM patients. Taken together, the data indicate that the AgR is efficient as paracoccidioidin in the evaluation of DHR in PBM, with an optimum time of reading the test of 24 h.
Resumo:
Purpose: Tissue reactions to 4 different implant surfaces were evaluated in regard to the development and progression of ligature-induced peri-implantitis. Materials and Methods: In 6 male mongrel dogs, a total of 36 dental implants with different surfaces (9 titanium plasma-sprayed, 9 hydroxyapatite-coated, 9 acid-etched, and 9 commercially pure titanium) were placed 3 months after mandibular premolar extraction. After 3 months with optimal plaque control, abutment connection was performed. Forty-five days later, cotton ligatures were placed around the implants to induce peri-implantitis. At baseline and 20, 40, and 60 days after placement, the presence of plaque, peri-implant mucosal redness, bleeding on probing, probing depth, clinical attachment loss, mobility, vertical bone loss, and horizontal bone loss were assessed. Results: The results did not show significant differences among the surfaces for any parameter during the study (P > .05). All surfaces were equally susceptible to ligature-induced peri-implantitis over time (P < .001). Correlation analysis revealed a statistically significant relationship between width of keratinized tissue and vertical bone loss (r 2 = 0.81; P = .014) and between mobility and vertical bone loss (r 2 = 0.66; P = .04), both for the titanium plasma-sprayed surface. Discussion and Conclusions: The present data suggest that all surfaces were equally susceptible to experimental peri-implantitis after a 60-day period.
Resumo:
Aim: To evaluate the influence of coronal filling and apical perforation on the induction of periapical inflammation. Methodology: Fifty-eight root canals in the teeth of dogs were divided into four groups. Groups I and II: root canals were exposed for 180 days; groups III and IV: root canals were exposed for 7 days and then the access cavity filled for 53 days. The root apices of groups I and III were perforated after the coronal opening, whilst those of groups II and IV remained intact. Standard radiographs were taken before and after the experimental periods. Digital images of the radiographs were created and then analysed by three examiners. After induction of periapical inflammation, the root canal contents were collected using paper points. Microbiologic evaluation of the type of microorganism was carried out by culture in different growth media. The radiographic and microbiologic data were statistically analysed using ANOVA at a 5% significance level. Results: There were a greater total number of microorganisms in groups I and II (P < 0.05). The number of anaerobes was greater than the number of aerobes (P < 0.05). The size of the periapical radiolucencies were not significantly different between the experimental groups. Conclusions: The different methods analysed induced similar areas of periapical radiolucency in dogs with predominantly anaerobic bacteria. However, the time required for induction was less when the method with coronal filling was used. © 2005 International Endodontic Journal.