987 resultados para End-expiratory Pressure


Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION Higher and lower cerebral perfusion pressure (CPP) thresholds have been proposed to improve brain tissue oxygen pressure (PtiO2) and outcome. We study the distribution of hypoxic PtiO2 samples at different CPP thresholds, using prospective multimodality monitoring in patients with severe traumatic brain injury. METHODS This is a prospective observational study of 22 severely head injured patients admitted to a neurosurgical critical care unit from whom multimodality data was collected during standard management directed at improving intracranial pressure, CPP and PtiO2. Local PtiO2 was continuously measured in uninjured areas and snapshot samples were collected hourly and analyzed in relation to simultaneous CPP. Other variables that influence tissue oxygen availability, mainly arterial oxygen saturation, end tidal carbon dioxide, body temperature and effective hemoglobin, were also monitored to keep them stable in order to avoid non-ischemic hypoxia. RESULTS Our main results indicate that half of PtiO2 samples were at risk of hypoxia (defined by a PtiO2 equal to or less than 15 mmHg) when CPP was below 60 mmHg, and that this percentage decreased to 25% and 10% when CPP was between 60 and 70 mmHg and above 70 mmHg, respectively (p < 0.01). CONCLUSION Our study indicates that the risk of brain tissue hypoxia in severely head injured patients could be really high when CPP is below the normally recommended threshold of 60 mmHg, is still elevated when CPP is slightly over it, but decreases at CPP values above it.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: An animal model has been developed to compare the effects of suture technique on the luminal dimensions and compliance of end-to-side vascular anastomoses. METHODS: Carotid and internal mammalian arteries (IMAs) were exposed in three pigs (90 kg). IMAs were sectioned distally to perform end-to-side anastomoses on carotid arteries. One anastomosis was performed with 7/0 polypropylene running suture. The other was performed with the automated suture delivery device (Perclose/Abbott Labs Inc.) that makes a 7/0 polypropylene interrupted suture. Four piezoelectric crystals were sutured on toe, heel and both lateral sides of each anastomosis to measure anastomotic axes. Anastomotic cross-sectional area (CSAA) was calculated with: CSAA = pi x mM/4 where m and M are the minor and major axes of the elliptical anastomosis. Cross-sectional anastomotic compliance (CSAC) was calculated as CSAC=Delta CSAA/Delta P where Delta P is the mean pulse pressure and Delta CSAA is the mean CSAA during cardiac cycle. RESULTS: We collected a total of 1200000 pressure-length data per animal. For running suture we had a mean systolic CSAA of 26.94+/-0.4 mm(2) and a mean CSAA in diastole of 26.30+/-0.5 mm(2) (mean Delta CSAA was 0.64 mm(2)). CSAC for running suture was 4.5 x 10(-6)m(2)/kPa. For interrupted suture we had a mean CSAA in systole of 21.98+/-0.2 mm(2) and a mean CSAA in diastole of 17.38+/-0.3 mm(2) (mean Delta CSAA was 4.6+/-0.1 mm(2)). CSAC for interrupted suture was 11 x 10(-6) m(2)/kPa. CONCLUSIONS: This model, even with some limitations, can be a reliable source of information improving the outcome of vascular anastomoses. The study demonstrates that suture technique has a substantial effect on cross-sectional anastomotic compliance of end-to-side anastomoses. Interrupted suture may maximise the anastomotic lumen and provides a considerably higher CSAC than continuous suture, that reduces flow turbulence, shear stress and intimal hyperplasia. The Heartflo anastomosis device is a reliable instrument that facilitates performance of interrupted suture anastomoses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ambulatory blood pressure (BP) was recorded in hypertensive patients whose physicians had been asked to reduce diastolic pressure measured in the office to 90 mm Hg or less. 34 hypertensive patients with a diastolic pressure measured by their physician of 95 mm Hg or more despite antihypertensive therapy had their treatment changed with the aim of achieving this pre-set goal within 3 months. At the beginning and the end of the study, ambulatory BP was monitored during the daytime with a portable non-invasive recorder. The results of the ambulatory recordings were not made available to the physicians until completion of the study. In half the patients the ambulatory diastolic pressure was already 90 mm Hg or less at the start. In these patients, treatment adjustment did not further decrease ambulatory BP. In contrast, patients who initially had an ambulatory diastolic pressure above 90 mm Hg had a significantly decreased ambulatory BP at the end of the study. Intensifying the therapy of hypertensive patients who have a normal ambulatory BP may result in overtreatment without any real gain in BP control.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Recent trials have documented no benefit from small reductions in blood pressure measured in the clinical office. However, ambulatory blood pressure is a better predictor of cardiovascular events than office-based blood pressure. We assessed control of ambulatory blood pressure in treated hypertensive patients at high cardiovascular risk. METHODS: We selected 4729 patients from the Spanish Ambulatory Blood Pressure Monitoring Registry. Patients were aged >/=55 years and presented with at least one of the following co-morbidities: coronary heart disease, stroke, and diabetes with end-organ damage. An average of 2 measures of blood pressure in the office was used for analyses. Also, 24-hour ambulatory blood pressure was recorded at 20-minute intervals with a SpaceLabs 90207 device. RESULTS: Patients had a mean age of 69.6 (+/-8.2) years, and 60.8% of them were male. Average time from the diagnosis of hypertension to recruitment into the Registry was 10.9 (+/-8.4) years. Mean blood pressure in the office was 152.3/82.3 mm Hg, and mean 24-hour ambulatory blood pressure was 133.3/72.4 mm Hg. About 60% of patients with an office-pressure of 130-139/85-89 mm Hg, 42.4% with office-pressure of 140-159/90-99 mm Hg, and 23.3% with office-pressure > or =160/100 mm Hg were actually normotensive, according to 24-hour ambulatory blood pressure criteria (<130/80 mm Hg). CONCLUSION: We suggest that the lack of benefit of antihypertensive therapy in some trials may partly be due to some patients having normal pressure at trial baseline. Ambulatory monitoring of blood pressure may allow for a better assessment of trial eligibility.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study analyses the stratigraphy, structure and kinematics of the northern part of the Adula nappe of the Central Alps. The Adula nappe is one of the highest basement nappes in the Lower Penninic nappe stack of the Lepontine Dome. This structural position makes possible the investigation of the transition between the Helvetic and North Penninic paleogeographic domains. The Adula nappe is principally composed of crystalline basement rocks. The investigation of the pre-Triassic basement shows that it contains several Palaeozoic detrital metasedimentary formations dated from the Cambrian to the Ordovician. These formations contain also some volcanic or intrusive magmatic rocks. Ordovician metagranites dated at ~450 Ma are also a common rock-type of the Adula basement. These formations underwent Alpine and Variscan deformation and metamorphism. Permian granites (Zervreila orthogneiss, dated at ~290 Ma) have intruded this pre-structured basement in a post-orogenic geodynamic context. Due to their age, the Zervreila orthogneiss are good markers for alpine deformation. The stratigraphy of the Mesozoic and Paleogene sedimentary cover of the Adula nappe is essential to unraveling its pre- orogenic history. The autochthonous cover is assigned to a North Penninic Triassic series that testifies for a transition between the Helvetic and Briançonnais Triassic domains. The Adula domain goes through an emersion during the Middle Jurassic, and is part of a topographic high during the first phase of the Alpine rift. The sediments of the late Middle Jurassic show a drowning phase associated with a tectonic activity and a breccia formation. In the neighbouring domains, coeval with the drowning phase in the Adula domain, a strong extensional crustal delamination and a scattered magmatic activity is associated with the main opening of the North Penninic domain. The Upper Jurassic of the Adula nappe is characterized by a carbonate formation comparable with those in the Helvetic or Subbriaçonnais domains. Flysch s.l. deposition starts probably at the end of the Cretaceous. These sediments are deposited on a large unconformity testifying for a Cretaceous sedimentary gap. The Adula nappe exhibits a very complex structure. This structure is formed by several deformation phases. Two ductile deformations are responsible for the nappe emplacement. The first deformation phase is associated with a folding compatible with a top-to-south movement at the top of the nappe. The second phase is dominant and pervasive throughout the whole nappe. It goes with a strong north vergent folding and the main nappe emplacement. These two phases cause the exhumation and emplacement of a coherent, although pre-structured, piece of continental crust. Two further deformation phases postdate the nappe emplacement. - Ce travail concerne l'étude géologique de la partie nord de la nappe de l'Adula dans les Alpes centrales. La nappe de l'Adula est l'une des nappes cristallines la plus élevée dans la pile des nappes du Pennique inférieur des Alpes lepontines. Cette position particulière permet d'étudier la transition entre les nappes des domaines helvétique et pennique inférieur. La nappe de l'Adula est principalement composée de socle cristallin : l'étude de l'histoire géologique du socle est donc l'un des thèmes de cette recherche. Ce socle contient plusieurs formations métasédimentaires paléozoïques du Cambrien à I'Ordovicien. Ces métasédiments sont issus de formations clastiques comprenant souvent des roches magmatiques volcaniques et intrusives. Ces métasédiments ont subi les cycles orogéniques varisque et alpin. La nappe de l'Adula contient plusieurs corps magmatiques granitiques métamorphisés. Les premiers métagranites sont Ordovicien et témoignent d'un environnement de marge active. Ces granites sont aussi polymétamorphiques. Les deuxièmes métagranites sont représentés par les orthogneiss de type Zervreila. Ce métagranite est d'âge permien (-290 Ma). Il est mis en place dans un contexte tectonique post-orogénique. Ce granite est un maqueur de la déformation alpine car il n'est pas affecté par les orogenèses précédentes, flippy Le contenu stratigraphique des roches mésozoïques et cénozoiques de la couverture sédimentaire de la nappe de l'Adula est'important pour en étudier son histoire pré-alpine. La couverture autochtone est composée d'une série d'âge triasique d'affinité nord-pennique, un faciès qui marque la transition entre les domaines helvétiques et briançonnais au Trias. Le domaine paléogéographique représenté dans la nappe de l'Adula connaît une émersion pendant le Jurassique moyen. Cette émersion marque le commencement du rift dans le domaine alpin. La sédimentation de la fin du Jurassique moyen est marquée par une transgression marine accompagnée par des mouvements tectoniques et la formation d'une brèche. Cette transgression est contemporaine des importants mouvements tectoniques et des manifestations magmatiques dans les unités voisines qui marquent la phase principale d'ouverture du bassin nord-pennique. Le Jurassique supérieur est caractérisé par l'instauration d'une sédimentation carbonatée comparable à celle du domaine helvétique ou subbriançonnais. Une sédimentation flyschoïde, probablement du Crétacé à Tertiaire, est déposée sur une importante discordance qui témoigne d'une lacune au Crétacé. La structure complexe de la nappe de l'Adula témoigne de nombreuses phases de déformation. Ces phases de déformation sont en partie issues de la mise en place de la nappe et de déformations plus tardives. La mise en place de la nappe produit deux phases de déformation ductile : la première produit un plissement compatible avec un cisaillement top-vers-le sud dans la partie supérieure de la nappe; la deuxième produit un intense plissement qui accompagne la mise en place de la nappe vers le nord. Ces deux phases de déformation témoignent d'un mécanisme d'exhumation par déformation ductile d'un bloc cohérent.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To test a method that allows automatic set-up of the ventilator controls at the onset of ventilation. DESIGN: Prospective randomized crossover study. SETTING: ICUs in one adult and one children's hospital in Switzerland. PATIENTS: Thirty intubated stable, critically ill patients (20 adults and 10 children). INTERVENTIONS: The patients were ventilated during two 20-min periods using a modified Hamilton AMADEUS ventilator. During the control period the ventilator settings were chosen immediately prior to the study. During the other period individual settings were automatically determined by the ventilatior (AutoInit). MEASUREMENTS AND RESULTS: Pressure, flow, and instantaneous CO2 concentration were measured at the airway opening. From these measurements, series dead space (V(DS)), expiratory time constant (RC), tidal volume (VT, total respiratory frequency (f(tot), minute ventilation (MV), and maximal and mean airway pressure (Paw, max and Paw, mean) were calculated. Arterial blood gases were analyzed at the end of each period. Paw, max was significantly less with the AutoInit ventilator settings while f(tot) was significantly greater (P < 0.05). The other values were not statistically significant. CONCLUSIONS: The AutoInit ventilator settings, which were automatically derived, were acceptable for all patients for a period of 20 min and were not found to be inferior to the control ventilator settings. This makes the AutoInit method potentially useful as an automatic start-up procedure for mechanical ventilation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CONTEXT: Fatigue-induced alterations in foot mechanics may lead to structural overload and injury. OBJECTIVES: To investigate how a high-intensity running exercise to exhaustion modifies ankle plantar-flexor and dorsiflexor strength and fatigability, as well as plantar-pressure distribution in adolescent runners. DESIGN: Controlled laboratory study. SETTING: Academy research laboratory. PATIENTS OR OTHER PARTICIPANTS: Eleven male adolescent distance runners (age = 16.9 ± 2.0 years, height = 170.6 ± 10.9 cm, mass = 54.6 ± 8.6 kg) were tested. INTERVENTION(S): All participants performed an exhausting run on a treadmill. An isokinetic plantar-flexor and dorsiflexor maximal-strength test and a fatigue test were performed before and after the exhausting run. Plantar-pressure distribution was assessed at the beginning and end of the exhausting run. MAIN OUTCOME MEASURE(S): We recorded plantar-flexor and dorsiflexor peak torques and calculated the fatigue index. Plantar-pressure measurements were recorded 1 minute after the start of the run and before exhaustion. Plantar variables (ie, mean area, contact time, mean pressure, relative load) were determined for 9 selected regions. RESULTS: Isokinetic peak torques were similar before and after the run in both muscle groups, whereas the fatigue index increased in plantar flexion (28.1%; P = .01) but not in dorsiflexion. For the whole foot, mean pressure decreased from 1 minute to the end (-3.4%; P = .003); however, mean area (9.5%; P = .005) and relative load (7.2%; P = .009) increased under the medial midfoot, and contact time increased under the central forefoot (8.3%; P = .01) and the lesser toes (8.9%; P = .008). CONCLUSIONS: Fatigue resistance in the plantar flexors declined after a high-intensity running bout performed by adolescent male distance runners. This phenomenon was associated with increased loading under the medial arch in the fatigued state but without any excessive pronation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Large phasic variations of respiratory mechanical impedance (Zrs) have been observed during induced expiratory flow limitation (EFL) (M. Vassiliou, R. Peslin, C. Saunier, and C. Duvivier. Eur. Respir. J. 9: 779-786, 1996). To clarify the meaning of Zrs during EFL, we have measured from 5 to 30 Hz the input impedance (Zin) of mechanical analogues of the respiratory system, including flow-limiting elements (FLE) made of easily collapsible rubber tubing. The pressures upstream (Pus) and downstream (Pds) from the FLE were controlled and systematically varied. Maximal flow (Vmax) increased linearly with Pus, was close to the value predicted from wave-speed theory, and was obtained for Pus-Pds of 4-6 hPa. The real part of Zin started increasing abruptly with flow (V) >85%Vmax and either further increased or suddenly decreased in the vicinity of V¿max. The imaginary part of Zin decreased markedly and suddenly above 95%Vmax. Similar variations of Zin during EFL were seen with an analogue that mimicked the changes of airway transmural pressure during breathing. After pressure andV measurements upstream and downstream from the FLE were combined, the latter was analyzed in terms of a serial (Zs) and a shunt (Zp) compartment. Zs was consistent with a large resistance and inertance, and Zp with a mainly elastic element having an elastance close to that of the tube walls. We conclude that Zrs data during EFL mainly reflect the properties of the FLE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In subjects with normal lung mechanics, inspiratory muscle strength can be reliably and easily assessed by the sniff nasal inspiratory pressure (SNIP), which is the pressure measured in an occluded nostril during a maximal sniff performed through the contralateral nostril. The aim of this study was to assess the validity of the SNIP in patients with chronic obstructive pulmonary disease (COPD), where pressure transmission from alveoli to upper airways is likely to be dampened. Twenty eight patients with COPD were studied (mean forced expiratory volume in one second (FEV1) = 36% of predicted). The SNIP and the sniff oesophageal pressure (sniff Poes) were measured simultaneously during maximal sniffs, and were compared to the maximal inspiratory pressure obtained against an occlusion (MIP). All measurements were performed from functional residual capacity in the sitting position. The ratio SNIP/sniff Poes was 0.80, and did not correlate with the degree of airflow limitation. The ratio MIP/sniff Poes was 0.87, and the ratio SNIP/MIP was 0.97. Inspiratory muscle weakness, as defined by a low sniff Poes, was present in 17 of the 28 patients. A false diagnosis of weakness was made in eight patients when MIP was considered alone, in four when SNIP was considered alone, and in only three patients when MIP and SNIP were combined. We conclude that both the sniff nasal inspiratory pressure and the maximal inspiratory pressure moderately underestimate sniff oesophageal pressure in chronic obstructive pulmonary disease. Although suboptimal in this condition, the sniff nasal inspiratory pressure appears useful to complement the maximal inspiratory pressure for assessing inspiratory muscle strength in patients with chronic obstructive pulmonary disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We describe a device made of artificial muscle for the treatment of end-stage heart failure as an alternative to current heart assist devices. The key component is a matrix of nitinol wires and aramidic fibers called Biometal muscle (BM). When heated electrically, it produces a motorless, smooth, and lifelike motion. The BM is connected to a carbon fiber scaffold, tightening the heart and providing simultaneous assistance to the left and right ventricles. A pacemaker-like microprocessor drives the contraction of the BM. We tested the device in a dedicated bench model of diseased heart. It generated a systolic pressure of 75 mm Hg and ejected a maximum of 330 ml/min, with an ejection fraction of 12%. The device required a power supply of 6 V, 250 mA. This could be the beginning of an era in which BMs integrate or replace the mechanical function of natural muscles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The rotational speed of high-speed electric machines is over 15 000 rpm. These machines are compact in size when compared to the power rate. As a consequence, the heat fluxes are at a high level and the adequacy of cooling becomes an important design criterion. In the high-speed machines, the air gap between the stator and rotor is a narrow flow channel. The cooling air is produced with a fan and the flow is then directed to the air gap. The flow in the gap does not provide sufficient cooling for the stator end windings, and therefore additional cooling is required. This study investigates the heat transfer and flow fields around the coil end windings when cooling jets are used. As a result, an innovative and new assembly is introduced for the cooling jets, with the benefits of a reduced amount of hot spots, a lower pressure drop, and hence a lower power need for the cooling fan. The gained information can also be applied to improve the cooling of electric machines through geometry modifications. The objective of the research is to determine the locations of the hot spots and to find out induced pressure losses with different jet alternatives. Several possibilities to arrange the extra cooling are considered. In the suggested approach cooling is provided by using a row of air jets. The air jets have three main tasks: to cool the coils effectively by direct impingement jets, to increase and cool down the flow that enters the coil end space through the air gap, and to ensure the correct distribution of the flow by forming an air curtain with additional jets. One important aim of this study is the arrangement of cooling jets in such manner that hot spots can be avoided to wide extent. This enables higher power density in high-speed motors. This cooling system can also be applied to the ordinary electric machines when efficient cooling is needed. The numerical calculations have been performed using a commercial Computational Fluid Dynamics software. Two geometries have been generated: cylindrical for the studied machine and Cartesian for the experimental model. The main parameters include the positions, arrangements and number of jets, the jet diameters, and the jet velocities. The investigated cases have been tested with two widely used turbulence models and using a computational grid of over 500 000 cells. The experimental tests have been made by using a simplified model for the end winding space with cooling jets. In the experiments, an emphasis has been given to flow visualisation. The computational analysis shows good agreement with the experimental results. Modelling of the cooling jet arrangement enables also a better understanding of the complex system of heat transfer at end winding space.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High blood pressure (BP) has been ranked as the most important risk factor worldwide regarding attributable deaths. Dietary habits are major determinants of BP. Among them, frequent intake of low-fat dairy products may protect against hypertension. Our aim was to assess the relationship between low-fat dairy product intake and BP levels and their changes after 12 month follow-up in a cohort of asymptomatic older persons at high cardiovascular risk recruited into a large-scale trial assessing the effects of Mediterranean diets on cardiovascular outcomes. Data from 2290 participants, including 1845 with hypertension, were available for analyses. Dairy products were not a specific part of the intervention; thus, data were analysed as an observational cohort. Dietary information was collected with validated semi-quantitative FFQ and trained personnel measured BP. To assess BP changes, we undertook cross-sectional analyses at baseline and at the end of follow-up and longitudinal analyses. A statistically significant inverse association between low-fat dairy product intake and systolic BP was observed for the 12-month longitudinal analysis. In the longitudinal analysis, the adjusted systolic and diastolic BP were significantly lower in the highest quintile of low-fat dairy product intake ( 2 4·2 (95% CI 2 6·9, 2 1·4) and 2 1·8 (95% CI 2 3·2, 2 0·4) mmHg respectively), whereas the point estimates for the difference in diastolic BP indicated a modest non-significant inverse association. Intake of low-fat dairy products was inversely associated with BP in an older population at high cardiovascular risk, suggesting a possible protective effect against hypertension.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High blood pressure (BP) has been ranked as the most important risk factor worldwide regarding attributable deaths. Dietary habits are major determinants of BP. Among them, frequent intake of low-fat dairy products may protect against hypertension. Our aim was to assess the relationship between low-fat dairy product intake and BP levels and their changes after 12 month follow-up in a cohort of asymptomatic older persons at high cardiovascular risk recruited into a large-scale trial assessing the effects of Mediterranean diets on cardiovascular outcomes. Data from 2290 participants, including 1845 with hypertension, were available for analyses. Dairy products were not a specific part of the intervention; thus, data were analysed as an observational cohort. Dietary information was collected with validated semi-quantitative FFQ and trained personnel measured BP. To assess BP changes, we undertook cross-sectional analyses at baseline and at the end of follow-up and longitudinal analyses. A statistically significant inverse association between low-fat dairy product intake and systolic BP was observed for the 12-month longitudinal analysis. In the longitudinal analysis, the adjusted systolic and diastolic BP were significantly lower in the highest quintile of low-fat dairy product intake ( 2 4·2 (95% CI 2 6·9, 2 1·4) and 2 1·8 (95% CI 2 3·2, 2 0·4) mmHg respectively), whereas the point estimates for the difference in diastolic BP indicated a modest non-significant inverse association. Intake of low-fat dairy products was inversely associated with BP in an older population at high cardiovascular risk, suggesting a possible protective effect against hypertension.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High blood pressure (BP) has been ranked as the most important risk factor worldwide regarding attributable deaths. Dietary habits are major determinants of BP. Among them, frequent intake of low-fat dairy products may protect against hypertension. Our aim was to assess the relationship between low-fat dairy product intake and BP levels and their changes after 12 month follow-up in a cohort of asymptomatic older persons at high cardiovascular risk recruited into a large-scale trial assessing the effects of Mediterranean diets on cardiovascular outcomes. Data from 2290 participants, including 1845 with hypertension, were available for analyses. Dairy products were not a specific part of the intervention; thus, data were analysed as an observational cohort. Dietary information was collected with validated semi-quantitative FFQ and trained personnel measured BP. To assess BP changes, we undertook cross-sectional analyses at baseline and at the end of follow-up and longitudinal analyses. A statistically significant inverse association between low-fat dairy product intake and systolic BP was observed for the 12-month longitudinal analysis. In the longitudinal analysis, the adjusted systolic and diastolic BP were significantly lower in the highest quintile of low-fat dairy product intake ( 2 4·2 (95% CI 2 6·9, 2 1·4) and 2 1·8 (95% CI 2 3·2, 2 0·4) mmHg respectively), whereas the point estimates for the difference in diastolic BP indicated a modest non-significant inverse association. Intake of low-fat dairy products was inversely associated with BP in an older population at high cardiovascular risk, suggesting a possible protective effect against hypertension.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High blood pressure (BP) has been ranked as the most important risk factor worldwide regarding attributable deaths. Dietary habits are major determinants of BP. Among them, frequent intake of low-fat dairy products may protect against hypertension. Our aim was to assess the relationship between low-fat dairy product intake and BP levels and their changes after 12 month follow-up in a cohort of asymptomatic older persons at high cardiovascular risk recruited into a large-scale trial assessing the effects of Mediterranean diets on cardiovascular outcomes. Data from 2290 participants, including 1845 with hypertension, were available for analyses. Dairy products were not a specific part of the intervention; thus, data were analysed as an observational cohort. Dietary information was collected with validated semi-quantitative FFQ and trained personnel measured BP. To assess BP changes, we undertook cross-sectional analyses at baseline and at the end of follow-up and longitudinal analyses. A statistically significant inverse association between low-fat dairy product intake and systolic BP was observed for the 12-month longitudinal analysis. In the longitudinal analysis, the adjusted systolic and diastolic BP were significantly lower in the highest quintile of low-fat dairy product intake ( 2 4·2 (95% CI 2 6·9, 2 1·4) and 2 1·8 (95% CI 2 3·2, 2 0·4) mmHg respectively), whereas the point estimates for the difference in diastolic BP indicated a modest non-significant inverse association. Intake of low-fat dairy products was inversely associated with BP in an older population at high cardiovascular risk, suggesting a possible protective effect against hypertension.