1000 resultados para Emission Abatement Measures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A common measure of the economic performance of different fleet segments in fisheries is the rate of return on capital. However, in the English Channel (UK), observed changes in the fleet structure are at odds with expectations given the observed rates of return on capital. This disjunction between expected and observed behaviour raises the question as to the appropriateness of rate of return on capital as a measure of economic performance for small boats whose main input is often non-wage labour. In this paper, an alternative performance indicator is developed based on returns on owner-operator labour. This indicator appears to be of more relevance to small scale boats than the traditional returns on capital, and a better indicator of the direction of adjustment in the fishery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Road construction and maintenance activities present challenges for ensuring the safety of workers and the traveling public alike. Hazards in work zones are typically studied using historical crash records but the current study took a qualitative approach by interviewing 66 workers from various work zones in Queensland, Australia. This supplemented and enhanced the limited available data regarding the frequency and nature of work zone crashes in Australia, provided worker insights into contributing factors, and assessed their opinions on the likely effectiveness of current or future approaches to hazard mitigation. Workers may not be aware of objective data regarding effectiveness, but their attitudes and consequent levels of compliance can influence both the likelihood of implementation and the outcomes of safety measures. Despite the potential importance of worker perceptions, they have not been studied comprehensively to date, and thus this study fills a significant gap in the literature. Excessive vehicle speeds, driver distraction and aggression towards roadworkers, working in wet weather, at night and close to traffic stream were among the most common hazards noted by workers. The safety measures perceived to be most effective included police presence, active enforcement, and improving driver awareness and education about work zones. Worker perceptions differed according to their level of exposure to hazards.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To investigate limb loading and dynamic stability during squatting in the early functional recovery of total hip arthroplasty (THA) patients. Design: Cohort study Setting: Inpatient rehabilitation clinic. Participants: A random sample of 61 THA patients (34♂/27♀; 62±9 yrs, 77±14 kg, 174±9 cm) was assessed twice, 13.2±3.8 days (PRE) and 26.6±3.3 days post-surgery (POST), and compared with a healthy reference group (REF) (22♂/16♀; 47±12yrs; 78±20kg; 175±10cm). Interventions: THA patients received two weeks of standard in-patient rehabilitation. Main Outcome Measure(s): Inter-limb vertical force distribution and dynamic stability during the squat maneuver, as defined by the root mean square (RMS) of the center of pressure in antero-posterior and medio-lateral directions, of operated (OP) and non-operated (NON)limbs. Self-reported function was assessed via FFb-H-OA 2.0 questionnaire. Results: At PRE, unloading of the OP limb was 15.8% greater (P<.001, d=1.070) and antero-posterior and medio-lateral center of pressure RMS were 30-34% higher in THA than REF P<.05). Unloading was reduced by 12.8% towards a more equal distribution from PRE to POST (P<.001, d=0.874). Although medio-lateral stability improved between PRE and POST (OP: 14.8%, P=.024, d=0.397; NON: 13.1%, P=.015, d=0.321), antero-posterior stability was not significantly different. Self-reported physical function improved by 15.8% (P<.001, d=0.965). Conclusion(s): THA patients unload the OP limb and are dynamically more unstable during squatting in the early rehabilitation phase following total hip replacement than healthy adults. Although loading symmetry and medio-lateral stability improved to the level of healthy adults with rehabilitation, antero-posterior stability remained impaired. Measures of dynamic stability and load symmetry during squatting provide quantitative information that can be used to clinically monitor early functional recovery from THA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXT: Identifying current physical activity levels and sedentary time of preschool children is important for informing government policy and community initiatives. This paper reviewed studies reporting on physical activity and time spent sedentary among preschool-aged children (2-5 years) using objective measures. EVIDENCE ACQUISITION: Databases were searched for studies published up to and including April 2013 that reported on, or enabled the calculation of, the proportion of time preschool children spent sedentary and in light- and moderate to vigorous-intensity physical activity. A total of 40 publications met the inclusion criteria for physical activity and 31 met the inclusion criteria for sedentary time. Objective measures included ActiGraph, Actiwatch, Actical, Actiheart, and RT3 accelerometers, direct observation, and Quantum XL telemetry heart rate monitoring. Data were analyzed in May 2013. EVIDENCE SYNTHESIS: Considerable variation in prevalence estimates existed. The proportion of time children spent sedentary ranged from 34% to 94%. The time spent in light-intensity physical activity and moderate to vigorous-intensity physical activity ranged from 4% to 33% and 2% to 41%, respectively. CONCLUSIONS: The considerable variation of prevalence estimates makes it difficult to determine the "true" prevalence of physical activity and sedentary time in preschool children. Future research should aim to reduce inconsistencies in the employed methodologies to better understand preschoolers' physical activity levels and sedentary behavior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Anthropogenic elemental mercury (Hg0) emission is a serious worldwide environmental problem due to the extreme toxicity of the heavy metal to humans, plants and wildlife. Development of an accurate and cheap microsensor based online monitoring system which can be integrated as part of Hg0 removal and control processes in industry is still a major challenge. Here, we demonstrate that forming Au nanospike structures directly onto the electrodes of a quartz crystal microbalance (QCM) using a novel electrochemical route results in a self-regenerating, highly robust, stable, sensitive and selective Hg0 vapor sensor. The data from a 127 day continuous test performed in the presence of volatile organic compounds and high humidity levels, showed that the sensor with an electrodeposted sensitive layer had 260% higher response magnitude, 3.4 times lower detection limit (,22 mg/m3 or ,2.46 ppbv) and higher accuracy (98% Vs 35%) over a Au control based QCM (unmodified) when exposed to a Hg0 vapor concentration of 10.55 mg/m3 at 1016C. Statistical analysis of the long term data showed that the nano-engineered Hg0 sorption sites on the developed Au nanospikes sensitive layer play a critical role in the enhanced sensitivity and selectivity of the developed sensor towards Hg0 vapor.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acoustic emission technique has become a significant and powerful structural health monitoring tool for structures. Researches to date have been done on crack location, fatigue crack propagation in materials and severity assessment of failure using acoustic emission technique. Determining severity of failure in steel structures using acoustic emission technique is still a challenge to accurately determine the relationship between the severity of crack propagation and acoustic emission activities. In this study three point bending test on low carbon steel samples along with acoustic emission technique have been used to determine crack propagation and severity. A notch is introduced at the tension face of the loading point to the samples to initiate the crack. The results show that the percentage of load drop of the steel specimen has a reciprocal relationship with the crack opening i.e. crack opening zones are influenced by the loading rate. In post yielding region, common acoustic emission signal parameters such as, signal strength, energy and amplitudes are found to be higher than those at pre-yielding and at yielding.