1000 resultados para Efluentes reais e sintéticos


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Environmental sustainability has become one of the topics of greatest interest in industry, mainly due to effluent generation. Phenols are found in many industries effluents, these industries might be refineries, coal processing, pharmaceutical, plastics, paints and paper and pulp industries. Because phenolic compounds are toxic to humans and aquatic organisms, Federal Resolution CONAMA No. 430 of 13.05.2011 limits the maximum content of phenols, in 0.5 mg.L-1, for release in freshwater bodies. In the effluents treatment, the liquid-liquid extraction process is the most economical for the phenol recovery, because consumes little energy, but in most cases implements an organic solvent, and the use of it can cause some environmental problems due to the high toxicity of this compound. Because of this, exists a need for new methodologies, which aims to replace these solvents for biodegradable ones. Some literature studies demonstrate the feasibility of phenolic compounds removing from aqueous effluents, by biodegradable solvents. In this extraction kind called "Cloud Point Extraction" is used a nonionic surfactant as extracting agent of phenolic compounds. In order to optimize the phenol extraction process, this paper studies the mathematical modeling and optimization of extraction parameters and investigates the effect of the independent variables in the process. A 32 full factorial design has been done with operating temperature and surfactant concentration as independent variables and, parameters extraction: Volumetric fraction of coacervate phase, surfactant and residual concentration of phenol in dilute phase after separation phase and phenol extraction efficiency, as dependent variables. To achieve the objectives presented before, the work was carried out in five steps: (i) selection of some literature data, (ii) use of Box-Behnken model to find out mathematical models that describes the process of phenol extraction, (iii) Data analysis were performed using STATISTICA 7.0 and the analysis of variance was used to assess the model significance and prediction (iv) models optimization using the response surface method (v) Mathematical models validation using additional measures, from samples different from the ones used to construct the model. The results showed that the mathematical models found are able to calculate the effect of the surfactant concentration and the operating temperature in each extraction parameter studied, respecting the boundaries used. The models optimization allowed the achievement of consistent and applicable results in a simple and quick way leading to high efficiency in process operation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work depicts a study of the adsorption of carbon dioxide on zeolite 13X. The activities were divided into four stages: study batch adsorption capacity of the adsorbent with synthetic CO2 (4%), fixed bed dynamic evaluation with the commercial mixture of gases (4% CO2, 1.11% CO, 1 2% H2, 0.233% CH4, 0.1% C3, 0.0233% C4 argon as inert closing balance), fixed bed dynamic modeling and evaluation of the breakthrough curve of CO2 originated from the pyrolysis of sewage sludge. The sewage sludge and the adsorbent were characterized by analysis TG / DTA, SEM, XRF and BET. Adsorption studies were carried out under the following operating conditions: temperature 40 °C (for the pyrolysis of the sludge T = 600 °C), pressures of 0.55 to 5.05 bar (batch process), flow rate of the gaseous mixture between 50 - 72 ml/min and the adsorbent masses of 10, 15 and 20 g (fixed bed process). The time for the adsorption batch was 7 h and on the fixed bed was around 180 min. The results of this study showed that in batch adsorption process step with zeolite 13X is efficient and the mass of adsorbed CO2 increases with the increases pressure, decreases with temperature increases and rises due the increase of activation temperature adsorbent. In the batch process were evaluated the breakthrough curves, which were compared with adsorption isotherms represented by the models of Langmuir, Freündlich and Toth. All models well adjusted to the experimental points, but the Langmuir model was chosen in view of its use in the dynamic model does not have implications for adsorption (indeterminacy and larger number of parameters such as occurred with others) in solving the equation. In the fixed bed dynamic study with the synthetic gas mixture, 20 g of mass adsorbent showed the maximum adsorption percentage 46.7% at 40 °C temperature and 50 mL/min of flow rate. The model was satisfactorily fitted to the three breakthrough curves and the parameters were: axial dispersion coefficient (0.0165 dm2/min), effective diffusivity inside the particle (dm2/min 0.0884) and external transfer coefficient mass (0.45 dm/min). The breakthrough curve for CO2 in the process of pyrolysis of the sludge showed a fast saturation with traces of aerosols presents in the gas phase into the fixed bed under the reaction process

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study of a promising alternative for the treatment of produced water from the oil industry envisaging its reuse was the focus of this work. Millions of liters of water are generated per day, containing heavy metals in low concentrations (< 0,15 mg/L for Pb, <0,04 mg/L for Cd, <0,04 mg/L for Ni). The technology applied to extract these metals from aqueous phase was the solvent extraction and the extratants used were vegetable oils originated from coconut oil. They can be used in natural form or as derivatives, known as MAC - Mixture of Carboxílics Acids. The determination of the heavy metal con¬centrations in a complex matrix was made by using the atomic absorption spectrometry technique (AAS). On the bench tests using synthetics aqueous solutions containing metals, vegetable oils showed no power to extract the metals studied. The extractant MAC was selective for the Pb> Cd> Ni, in the concentration of 8% in the same organic phase. In this condition, the lower efficiency of extraction obtained was 92% for the Pb, 69% for the Cd, in the range of pH ranging from 6 to 8. An experimental planning was conducted for continuous tests. The device used was called MDIF Misturador-Decantador à Inversão de Fases and the aqueous phase was produced water from Pólo Indutrial de Guamaré/RN . No correlation between the studied variables (concentration of metal, concentration of extratant and agitation in the mixing chamer) could be obtained, because of possible factors which occurred as: variation in the composition of the studied sample, phenomena of precipitation and complexation of metals in the reservoir of feed, solubility of extratant

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the main impacts to the environment is the water pollution, where the industrial sector is one of the main sources of this problem. In order to search for a solution, the industrial sector is looking forward to new technologies to treat its wastewaters with the goal to reuse the water in the own process. In this mode, the treatment presents a reduction in its costs with the water suply. One of these technologies that are getting more and more applications is the advanced oxidative processes (AOP´s). In this work two industrial wastewaters have been studied, i.e., containing polymers and pharmacus. In the case of the wastewaters with polymers the UV/H2O2 process has been applied with a systematic series of experiments, using irradiation from a mercury lamp and also solar. The following variables of the UV/H2O2 process for the polymers wastewaters have been studied systematically with the lamp reactor: mode of addition of hydrogen peroxide, temperature, time of reaction, hydrogen peroxide concentration and power of the lamp (80, 125, 250 and 400W). The results demonstrated to be satisfactory, obtaining rates of organic charge removal of 100% in 120 minutes of reaction. The studied variables for the experiments with solar irradiation using polymers wastewaters were only the time of reaction, the mode of addition and concentration of the hydrogen peroxide. The results with the solar irradiation demonstrated to be not satisfactory, reaching maximum of 22% of TOC removal in 240 minutes of reaction. This is in accordance with the fact that the solar source has only 5% of low UV irradiation. With respect to the photodegradation of the pharmacus wastewaters, the process UV/H2O2 and photo-Fenton have been applied. As a source of photons, in this case, a mercury UV lamp of 80 W has been used. The studied variables for the experiments with artificial irradiation with the pharmacus wastewaters were: initial concentration of the pollutant, concentration of Fe2+ and time of reaction. The results demonstrated a degree of degradation fairly satisfactory, showing a maximum conversion value of 46% in 120 minutes

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An evaluation project was conducted on the technique of treatment for effluent oil which is the deriving process to improve cashews. During the evaluation the following techniques were developed: advanced processes of humid oxidation, oxidative processes, processes of biological treatment and processes of adsorption. The assays had been carried through in kinetic models, with an evaluation of the quality of the process by means of determining the chemical demand of oxygen (defined as a technique of control by means of comparative study between the available techniques). The results demonstrated that the natural biodegradation of the effluent ones is limited, as result using the present natural flora in the effluent one revealed impracticable for an application in the industrial systems, independent of the evaluation environment (with or without the oxygen presence). The job of specific microorganisms for the oily composite degradation developed the viability technique of this route, the acceptable levels of inclusion in effluent system of treatment of the improvement of the cashew being highly good with reasonable levels of removal of CDO. However, the use combined with other techniques of daily pay-treatment for these effluent ones revealed to still be more efficient for the context of the treatment of effluent and discarding in receiving bodies in acceptable standards for resolution CONAMA 357/2005. While the significant generation of solid residues the process of adsorption with agroindustrial residues (in special the chitosan) is a technical viable alternative, however, when applied only for the treatment of the effluent ones for discarding in bodies of water, the economic viability is harmed and minimized ambient profits. Though, it was proven that if used for ends of I reuse, the viability is equalized and justifies the investments. There was a study of the photochemistry process which have are applicable to the treatment of the effluent ones, having resulted more satisfactory than those gotten for the UV-Peroxide techniques. There was different result on the one waited for the use of catalyses used in the process of Photo. The catalyses contained the mixing oxide base of Cerium and Manganese, incorporated of Potassium promoters this had presented the best results in the decomposition of the involved pollutants. Having itself an agreed form the gotten photochemistry daily paytreatment resulted, then after disinfection with chlorine the characteristics next the portability to the water were guarantee. The job of the humid oxidation presented significant results in the removal of pollutants; however, its high cost alone is made possible for job in projects of reuses, areas of low scarcity and of raised costs with the capitation/acquisition of the water, in special, for use for industrial and potable use. The route with better economic conditions and techniques for the job in the treatment of the effluent ones of the improvement of the cashew possesses the sequence to follow: conventional process of separation water-oil, photochemistry process and finally, the complementary biological treatment

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although the good performance in organic matter and suspended solids removal, the anaerobic reactors are unable to remove ammonia nitrogen from sewage, which makes indispensable to include a step of post-treatment for removal of ammonia or nitrate as necessary. This paper presents the performance of a new variant technology, where the nitrification unit, preceded by anaerobic units, is a submerged aerated biological filter, without continuous sludge discharge in their daily operation. The oxygenation system is very simple and inexpensive, consisting of perforated hoses and compressors. The anaerobic reactors are a septic tank with two chambers followed (8.82 m³) and two parallel anaerobic filters (36 m³ each) filled with ceramic bricks and conics plastic parts. Both followed aerated filters were filled with cut corrugated conduit. The study evaluated the behavior of the system with constant domestic sewage flow (10 m³/d) and different aeration conditions, are these: stage 01, when applied air flow of 0.01 m³ air/min in both aerated filter; stage 02, remained in the initial air flow rate in the second aerated filter and increased at the first to 0.05 m³ air/min; at last, at last, in stage 03, the air flow rate of first aerated filter was 0.10 m³ air/min and on the second remained at 0.01 m³ air/min. The filter FA1 received load of 0.41 kg COD/m³.d, 0.37 kg COD/m³.d and 0.26 kg COD/m³.d on phases 01, 02 and 03, respectively. The FA2 received loads of 0.25 kg COD/m³.d, 0.18 kg COD/m³.d and 0.14 kg COD/m³.d on phases 01, 02 and 03, respectively. During stage 01, were found the following results: 98% removals of BODtotal and 92% of CODtotal, with effluent presenting 9 mg/L of BODtotal final average and 53 mg/L of CODtotal average; suspended solids removals of 93%, with a mean concentration of 10 mg/L in the final effluent; 47% reduction of ammonia of FA2 to FAN 's, presenting average of 28 mg NNH3/ L of ammonia in the effluent with; the dissolved oxygen levels always remained around 2.0 mg/L. During stage 02, were found removals of 97% and 95% to BODtotal and suspended solids, respectively, with average final concentrations of 8 and 7 mg/L, respectively; was removed 60% of ammonia, whose final concentration was 16.3 mg NNH3/ L, and nitrate was increased to a final average concentration of 16.55 mg N-NO3/L. Finally, the stage 03 provided 6 mg/L of DBOtotal (98% removal) and 23 mg/L of CODtotal (95% removal) of final effluent concentrations average. At this stage was identified the higher ammonia oxidation (86%), with final effluent showing average concentration of 6.1 mg N-NH3/L, reaching a minimum of 1.70 mg N-NH3/L. In some moments, during stage 03, there was a moderate denitrification process in the last aerated filter. The average turbidity in the effluent showed around 1.5 NTU, proving the good biomass physical stability. Therefore, the results demonstrate the submerged biological filters potential, filled with high void ratio material (98%), and aerated with hoses and compressor adoption, in the carbonaceous and nitrogenous matter oxidation, also generating an effluent with low concentration of solids

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experience in the use of stabilization ponds shows that this is a system with low cost, easy operation and maintenance and suitable for tropical countries. One of its disadvantages is due to high concentrations of suspended solids, mainly due to algal biomass in the effluents. Accordingly, the dissolved air flotation has been shown to be an efficient post-treatment technology. However, the efficiency of this process is related to coagulation and flocculation steps, as well as the adjustment of the involved variables in the process. The objective of this work was to evaluate the algae removal efficiency from wastewater stabilization ponds and the influence of the factors involved in the process using dissolved air flotation. For this, we used primary facultative and maturation effluents of ETE Ponta Negra in Natal. We did tests of coagulation, flocculation and flotation with the samples, using the equipment flotatest. In this process were tested coagulants aluminum sulfate and ferric chloride, and varied the factors pH, coagulant concentration, polymer concentration and rate of recirculation. At the end of the experiments were analyzed turbidity, suspended solids, color, COD and chlorophyll "a". These results were submitted to descriptive statistics to verify the efficiency of the process in general, and regression analysis to identify models that describe the process and demonstrate the factors that have greater influence on flotation. After step methodology, high values were found removal efficiency of suspended solids, reaching values greater than 90% in the best cases. It was concluded that flotation is more efficient in the facultative pond effluent using ferric chloride, and the variability of algae may negatively influence the process. Regression analyzes showed that pH is the most influential variable in the coagulation-flocculation-flotation, and its optimal value among the tested is 5.5 for both coagulants

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stabilization pond is the most used sewage treatment system in the country, corresponding to approximately 90% of all systems. The systems evaluated were stabilization ponds system of sewage treatment in the city of Natal / RN. This research aimed to analyze the possible uses through physical-chemical and bacteriological of these final effluent ponds for urban uses depending on the characteristics after passage around the treatment system. The parameters used were chosen according to those established by Chernicharo et al. (2006), in order to characterize the effluent. The parameters evaluated were: DO, temperature, pH, conductivity, organic nitrogen, ammonia, NTK, total phosphorus, and series of solid fecal coliforms. Generally, the characteristics of the effluent followed variability found in the literature. The results showed an efficiency that is technically feasible to use the effluent end of some of STPs analyzed when checked parameters alone, if fitting in unrestricted urban use, restricted use and urban land use

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research evaluated the microalgae removal produced in a stabilization pond system using biofilters as post-treatment, besides characterizing the effluents of stabilization ponds and filters in relation to concentrations of algal biomass (chlorophyll a and suspended solids), organic matter (BOD and COD), total phosphorus, orthophosphate, pH and dissolved oxygen, and tried to correlate physicochemical parameters with chlorophyll "a". It was held at the Ponta Negra ETE which is constituted by three stabilization ponds, with a primary facultative pond and two of maturation. For the algae removal were used two submerged bio-filters: the filter FPF (Facultative Pond Filter), fed with facultative pond effluent; and the filter MPF (Maturation Pond Filter), fed with second maturation pond effluent. The filling material of both filters was predominantly gravel no. 2, although it contains portions of gravel no. 1 and no. 3. The filters operating conditions were bad, they were nearly 10 years without maintenance, without cleaning or removal of sludge since the time of its construction, and part of the filling material may be obstruct. Despite poor operating conditions were obtained satisfactory results, in level of posttreatment. Removal efficiencies in relation to BOD and COD were 7 and 25% in FPF and 9 and 19% and in MPF, respectively. In relation to TSS efficiencies in MPF and FPF were 37 and 20%, respectively. As for the chlorophyll "a" removal, the FPF efficiency was 44% and the MPF was 40%. There was 50% of consumption of dissolved oxygen, on average, within the filters. Two profiles were performed in the filters, and it was possible to conclude that variations throughout the day were not statistically significant, and that, regardless of the time of collection, they would have the same representation comparing to the time of data collection (7 am) and the daily average, although individual variations throughout the day have been shown to be significant. Another important observation is that the correlations between Chlorophyll a and TSS were bigger and more significant in the effluent of the filters than in the effluent of the ponds

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Piranhas-Açu basin is a Federal watershed with a drainage area of 43.681,5 km2, sited at Brazilian northeast semi arid, with 60% of your area in Paraiba State and 40% in Rio Grande do Norte State. The main river, Piranhas-Açu, has strategic importance for development of these states, because it s an essential source for many socio-economics activities developed along watercourse. The river s reach between Coremas-Mãe D`água Dam and Armando Ribeiro Gonçalves Dam has many irrigation projects, and supply many riverside cities. All this activities practiced in this river s reach consumes high water volumes. Due the importance of this stream and the necessity of an adequate management, this work aims for an impartial and detailed evaluation of real water supply conditions in this river s reach, by the application of hydrological modeling, including the arrangement of main dams in tributaries, and storage reservoir water balance. The rainfall-discharge model s applied in each sub-basins it was selected the model MODHISA- Hydrological Model of Semi Arid, that is a concentrated model with easy application. The simulation produced 50 years of inflows into the reservoirs, for which, were constructed the guaranties curves; and produced 50 years of synthetic discharge data in relevant points on the river and on its affluents; so it was constructed the permanence curves. Confronting the available discharge with the current and futures volumes of raw water captured in this river s reach, it was verified that de demands have high guaranties. This work concluded that the MODHISA Model is suitable to reproduce the hydrologic characteristics of Piranhas-Açu sub-basins, and showing good results

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polyester fibers are the most used fibers in the world and disperse dyes are used for dyeing these fibers. After dyeing, the colorful dyebath is discharged into effluent streams, which needs a special treatment for color removal. Surfactants interaction with dyes has been evaluated in several studies, including the textile area, specifically in the separation of dyes from textile wastewater. In this work a cationic surfactant was used in a microemulsion system for the extraction of anionic dyes (disperses dyes) from textile wastewater. These microemulsion system was composed by dodecylamonium chloride (surfactant), kerosene oil (organic phase), isoamyl alcohol (cosurfactant) and the wastewater (aqueous phase). The wastewater that results after the dyeing process is acid (pH 5). It was observed that changing the pH value to above 12.8 the extraction could be made, resulting in an aqueous phase with low color level. The Scheffé net experimental design was used for the extraction process optimization, and the obtained results were evaluated using the program "Statistica 7.0". The optimal microemulsion system was composed by 59.8wt.% of wastewater, 30.1wt.% of kerosene, 3.37wt.% of surfactant and 6.73wt.% of cosurfactant, providing extraction upper than 96%. A mix of reactive dyebath (50%) and disperse dyebath (50%) was used as aqueous phase and it presented extraction upper than 98%. The water phase after extraction process can be reused in a new dyeing, being obtained satisfactory results, according to the limits established by textile industry for a good dyeing. Tests were accomplished seeking to study the influence of salt addition and temperature. An experimental design was used for this purpose, which showed that the extraction doesn't depend on those factors. In this way, the removal of color from textile wastewater by microemulsion is a viable technique (that does not depend of external factors such as salinity and temperature), being obtained good extraction results even with in wastewater mixtures

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A matemática intervalar é uma teoria matemática originada na década de 60 com o objetivo de responder questões de exatidão e eficiência que surgem na prática da computação científica e na resolução de problemas numéricos. As abordagens clássicas para teoria da computabilidade tratam com problemas discretos (por exemplo, sobre os números naturais, números inteiros, strings sobre um alfabeto finito, grafos, etc.). No entanto, campos da matemática pura e aplicada tratam com problemas envolvendo números reais e números complexos. Isto acontece, por exemplo, em análise numérica, sistemas dinâmicos, geometria computacional e teoria da otimização. Assim, uma abordagem computacional para problemas contínuos é desejável, ou ainda necessária, para tratar formalmente com computações analógicas e computações científicas em geral. Na literatura existem diferentes abordagens para a computabilidade nos números reais, mas, uma importante diferença entre estas abordagens está na maneira como é representado o número real. Existem basicamente duas linhas de estudo da computabilidade no contínuo. Na primeira delas uma aproximação da saída com precisão arbitrária é computada a partir de uma aproximação razoável da entrada [Bra95]. A outra linha de pesquisa para computabilidade real foi desenvolvida por Blum, Shub e Smale [BSS89]. Nesta aproximação, as chamadas máquinas BSS, um número real é visto como uma entidade acabada e as funções computáveis são geradas a partir de uma classe de funções básicas (numa maneira similar às funções parciais recursivas). Nesta dissertação estudaremos o modelo BSS, usado para se caracterizar uma teoria da computabilidade sobre os números reais e estenderemos este para se modelar a computabilidade no espaço dos intervalos reais. Assim, aqui veremos uma aproximação para computabilidade intervalar epistemologicamente diferente da estudada por Bedregal e Acióly [Bed96, BA97a, BA97b], na qual um intervalo real é visto como o limite de intervalos racionais, e a computabilidade de uma função intervalar real depende da computabilidade de uma função sobre os intervalos racionais

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Symbolic Data Analysis (SDA) main aims to provide tools for reducing large databases to extract knowledge and provide techniques to describe the unit of such data in complex units, as such, interval or histogram. The objective of this work is to extend classical clustering methods for symbolic interval data based on interval-based distance. The main advantage of using an interval-based distance for interval-based data lies on the fact that it preserves the underlying imprecision on intervals which is usually lost when real-valued distances are applied. This work includes an approach allow existing indices to be adapted to interval context. The proposed methods with interval-based distances are compared with distances punctual existing literature through experiments with simulated data and real data interval

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to the constantly increasing use of wireless networks in domestic, business and industrial environments, new challenges have emerged. The prototyping of new protocols in these environments is typically restricted to simulation environments, where there is the need of double implementation, one in the simulation environment where an initial proof of concept is performed and the other one in a real environment. Also, if real environments are used, it is not trivial to create a testbed for high density wireless networks given the need to use various real equipment as well as attenuators and power reducers to try to reduce the physical space required to create these laboratories. In this context, LVWNet (Linux Virtual Wireless Network) project was originally designed to create completely virtual testbeds for IEEE 802.11 networks on the Linux operating system. This paper aims to extend the current project LVWNet, adding to it the features like the ability to interact with real wireless hardware, provides a initial mobility ability using the positioning of the nodes in a space coordinates environment based on meters, with loss calculations due to attenuation in free space, enables some scalability increase by creating an own protocol that allows the communication between nodes without an intermediate host and dynamic registration of nodes, allowing new nodes to be inserted into in already in operation network

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Environmental pollution causes the loss of the quality of aquatic resources and also affects the health of human beings. The Golandim River is located in São Gonçalo do Amarante (RN Brazil) and had its water recovered seven years ago by measurements of parameters of the water s quality analyses physicochemistry, microbiological and heavy metals. However, it is not well established if this river is truly recovered, so this study provides a wide knowledge about the quality of these waters. Therefore, this investigation was accomplished by assays of ecotoxicology utilizing Ceriodaphnia dubia and of genotoxicity of the river s water using a biomarker Tradescantia Pallida (Trad-MCN). In set, it carried through a study of environmental perception through questionnaires that approached questions related to the profile of the interviewed one, knowledge on the environment and of the river Golandim with the community that lives in the neighborhoods of the river to diagnosis as they perceive the environment where live and its problems. The assays of the water had been carried out by collecting samples in three different sites of the Golandim River. They were collected between the periods of December 2010 (dry season in the northeast of Brazil) and July 2011 (rainy season in the northeast of). The analysis of the data allowed observing that the majority of the inhabitants are adult and presents a global vision of what it is part of the environment, the majority mentions the pollution of the river as one of the problems of the city, considering it serious. The ecotoxicology assay showed that there was not acute toxicity in all three samples collected. Meanwhile, all these three samples demonstrated significant chronic toxicity. The results from the Trad-MCN assay presented an increase in the frequency of micronucleus in one of the sites analyzed (S3) (p<0.01), in both seasons collected. On the other hand, the sites S1 and S2 did not presented a significant increase of micronucleus using this bioassay. The analyses of chemicals detected an increase in the levels of some metals, in different seasons and samples, which can be associates with some compounds found in urban and industrial areas. On the other hand, the physicochemistries parameters demonstrated that the Golandim River is recouped, when compared with the values presented at the CONAMA s legislation. However, these results indicate the presence of compounds capable of inducing chromosomal mutation in plants. On the other hand, the parameters physicistchemistries demonstrate that the river Golandim is if recouping, since when compares the values observed with the legislation of the CONAMA. All these results point to the fact that the Trad-MCN assay was sensitive and efficient biomarker for chromosomal instability and the C. dubia ecotoxicology assay was as though an efficient biomarker of toxicity of water s quality. The results from Trad-MCN associated with the ecotoxicology demonstrates that these analyses are important for environmental monitoring, once the first bioassay described above indicates alterations at the standards of cells and the other one indicates alterations at the standards of organisms. This study alerts for the necessity to carry out biological assays for the analyses of the water s quality