669 resultados para ELECTROGENERATED CHEMILUMINESCENCE BIOSENSOR
Resumo:
A rapid biological method for the determination of the bioavailability of naphthalene was developed and its value as an alternative to extraction-based chemical approaches demonstrated. Genetically engineered whole-cell biosensors are used to determine bioavailable naphthalene and their responses compared with results from Tenax extraction and chemical analysis. Results show a 1:1 correlation between biosensor results and chemical analyses for naphthalene-contaminated model materials and sediments, but the biosensor assay is much faster. This work demonstrates that biosensor technology can perform as well as standard chemical methods, though with some advantages including the inherent biological relevance of the response, rapid response time, and potential for field deployment. A survey of results from this work and the literature shows that bioavailability under non-equilibrium conditions nonetheless correlates well with K(oc) or K(d). A rationale is provided wherein chemical resistance is speculated to be operative.
Resumo:
A wide variety of whole cell bioreporter and biosensor assays for arsenic detection has been developed over the past decade. The assays permit flexible detection instrumentation while maintaining excellent method of detection limits in the environmentally relevant range of 10-50 μg arsenite per L and below. New emerging trends focus on genetic rewiring of reporter cells and/or integration into microdevices for more optimal detection. A number of case studies have shown realistic field applicability of bioreporter assays.
Resumo:
In order to improve the efficacy and safety of treatments, drug dosage needs to be adjusted to the actual needs of each patient in a truly personalized medicine approach. Key for widespread dosage adjustment is the availability of point-of-care devices able to measure plasma drug concentration in a simple, automated, and cost-effective fashion. In the present work, we introduce and test a portable, palm-sized transmission-localized surface plasmon resonance (T-LSPR) setup, comprised of off-the-shelf components and coupled with DNA-based aptamers specific to the antibiotic tobramycin (467 Da). The core of the T-LSPR setup are aptamer-functionalized gold nanoislands (NIs) deposited on a glass slide covered with fluorine-doped tin oxide (FTO), which acts as a biosensor. The gold NIs exhibit localized plasmon resonance in the visible range matching the sensitivity of the complementary metal oxide semiconductor (CMOS) image sensor employed as a light detector. The combination of gold NIs on the FTO substrate, causing NIs size and pattern irregularity, might reduce the overall sensitivity but confers extremely high stability in high-ionic solutions, allowing it to withstand numerous regeneration cycles without sensing losses. With this rather simple T-LSPR setup, we show real-time label-free detection of tobramycin in buffer, measuring concentrations down to 0.5 μM. We determined an affinity constant of the aptamer-tobramycin pair consistent with the value obtained using a commercial propagating-wave based SPR. Moreover, our label-free system can detect tobramycin in filtered undiluted blood serum, measuring concentrations down to 10 μM with a theoretical detection limit of 3.4 μM. While the association signal of tobramycin onto the aptamer is masked by the serum injection, the quantification of the captured tobramycin is possible during the dissociation phase and leads to a linear calibration curve for the concentrations over the tested range (10-80 μM). The plasmon shift following surface binding is calculated in terms of both plasmon peak location and hue, with the latter allowing faster data elaboration and real-time display of the results. The presented T-LSPR system shows for the first time label-free direct detection and quantification of a small molecule in the complex matrix of filtered undiluted blood serum. Its uncomplicated construction and compact size, together with the remarkable performances, represent a leap forward toward effective point-of-care devices for therapeutic drug concentration monitoring.
Resumo:
Expression control in synthetic genetic circuitry, for example, for construction of sensitive biosensors, is hampered by the lack of DNA parts that maintain ultralow background yet achieve high output upon signal integration by the cells. Here, we demonstrate how placement of auxiliary transcription factor binding sites within a regulatable promoter context can yield an important gain in signal-to-noise output ratios from prokaryotic biosensor circuits. As a proof of principle, we use the arsenite-responsive ArsR repressor protein from Escherichia coli and its cognate operator. Additional ArsR operators placed downstream of its target promoter can act as a transcription roadblock in a distance-dependent manner and reduce background expression of downstream-placed reporter genes. We show that the transcription roadblock functions both in cognate and heterologous promoter contexts. Secondary ArsR operators placed upstream of their promoter can also improve signal-to-noise output while maintaining effector dependency. Importantly, background control can be released through the addition of micromolar concentrations of arsenite. The ArsR-operator system thus provides a flexible system for additional gene expression control, which, given the extreme sensitivity to micrograms per liter effector concentrations, could be applicable in more general contexts.
Resumo:
BACKGROUND & AIMS: Protein and energy requirements in critically ill children are currently based on insufficient data. Moreover, longitudinal measurements of both total urinary nitrogen (TUN) and resting energy expenditure (REE) are lacking. The aim of this study was to investigate how much protein and energy are needed to equilibrate nitrogen and energy balances in ventilated critically ill children on the basis of daily measurements of TUN, REE and protein and energy intakes. Comparisons were made with the guidelines of the American Society for Parenteral and Enteral Nutrition and the Dietary Reference Intakes. METHODS: Children with an expected duration of mechanical ventilation ≥72 h were prospectively recruited. TUN was measured by chemiluminescence, and REE was measured by indirect calorimetry. Generalised linear models for longitudinal data were used to study the relation between protein intake and nitrogen balance and to calculate the minimum intake of protein needed to achieve nitrogen equilibrium. A similar approach was used for energy. Results were compared to the recommended values. RESULTS: Based on 402 measurements performed in 74 children (median age: 21 months), the mean TUN was high at 0.20 (95% CI: 0.20, 0.22) g/kg/d and the REE was 55 (95% CI: 54, 57) kcal/kg/d. Nitrogen and energy balances were achieved with 1.5 (95% CI: 1.4, 1.6) g/kg/d of protein and 58 (95% CI: 53, 63) kcal/kg/d for the entire group, but there were differences among children of different ages. Children required more protein and less energy than the Dietary Reference Intakes. CONCLUSIONS: In critically ill children, TUN was elevated and REE was reduced during the entire period of mechanical ventilation. Minimum intakes of 1.5 g/kg/d of protein and 58 kcal/kg/d can equilibrate nitrogen and energy balances in children up to 4 years old. Older children require more protein.
Resumo:
The electrochemistry field has increased in recent years, specially in the search for new sensors to monitor specific analyte in complex samples. In order to improve electrodes, many rhodium compounds have been used as electron mediators for novel sensors development. The most used compounds for this purpose are metal, metal complexes and some organic dyes. Rhodium complexes are known by their good catalytic properties and it could be useful in the sensor field. However, there are only a few reports, on the use of rhodium complexes in sensors and biosensors. A brief review of the electrochemistry of rhodium complexes and some discription of their properties which make those compounds suitable for development of sensor and biosensor.
Resumo:
The generation of "cold light", visible to the human eye, by chemical reactions has attracted the attention of the scientific community since the beginning of this century. Besides the academic interest in the elucidation of the mechanisms of excited state formations, many chemiluminescence reactions have found widespread analytical applications. Moreover, the phenomenon of chemiluminescence can also be used as a tool in undergraduate and college teaching. In this article, we describe several known chemiluminescence demonstrations, which are suitable for school teaching. The main objective of this work is to produce didactic material in Portuguese to stimulate Brazilian secondary and high school teachers to use these experiments in the classroom. The demonstrations include singlet oxygen emission, the luminol reaction, oscillating chemiluminescence and the peroxyoxalate reaction.
Resumo:
The peroxyoxalate system is still one of the most efficient chemiluminescence reactions and the only one supposed to involve the "Chemically Initiated Electron Exchange Luminescence - CIEEL" mechanism, with proved high efficiency. Besides the academic interest in the elucidation of the mechanism of this complex reaction, the peroxyoxalate system has found a variety of applications in analytical chemistry. This review contains (i) a short introduction to basic concepts in chemiluminescence, (ii) a critical summary of mechanistic studies on the peroxyoxalate reaction, (iii) and some examples of analytical applications. Although there are some recent reviews on chemiluminescence, no specific critical revision on mechanistic and analytical features of the peroxyoxalate system has been published.
Resumo:
Phenols are widely used in many areas and commonly found as industrial by-products. A great number of agricultural and industrial activities realise phenolic compounds in the environmental. Waste phenols are produced mainly by the wood-pulp industry and during production of synthetic polymers, drugs, plastics, dyes, pesticides and others. Phenols are also released into the environmental by the degradation of pesticides with phenolic skeleton. The phenols level control is very important for the environmental protection. Amperometric biosensor has shown the feasibility to complement laboratory-based analytical methods for the determination of phenolic compounds, providing alternatives to conventional methods which have many disadvantages. This brief review considers the evolution of an approach to amperometric measurement using the catalytic properties of some enzymes for phenolic compounds monitoring.
Resumo:
Chemically modified electrodes based on hexacyanometalate films are presented as a tool in analytical chemistry. Use of amperometric sensors and/or biosensors based on the metal-hexacyanoferrate films is a tendency. This article reviews some applications of these films for analytical determination of both inorganic (e.g. As3+, S2O3(2-)) and organic (e.g. cysteine, hydrazine, ascorbic acid, gluthatione, glucose, etc.) compounds.
Resumo:
This paper presents some results that may be used as previous considerations to a hydrogen peroxide electrogeneration process design. A kinetic study of oxygen dissolution in aqueous solution is carried out and rate constants for oxygen dissolution are calculated. Voltammetric experiments on vitreous carbon cathode shown that the low saturation concentration drives the oxygen reduction process to a mass transfer controlled process which exhibits low values of limiting currents. Results have shown that the hydrogen peroxide formation and its decomposition to water are separated by 400 mV on the vitreous carbon surface. Diffusion coefficients for oxygen and hydrogen peroxide are calculated using data taken from Levich and Tafel plots. In a series of bulk electrolysis experiments hydrogen peroxide was electrogenerated at several potential values, and concentration profiles as a function of the electrical charged passed were obtained. Data shown that, since limiting current plateaus are poorly defined onto reticulated vitreous carbon, cathodic efficiency may be a good criterion for choosing the potential value in which hydrogen peroxide electrogeneration should be carried out.
Resumo:
In this review article, we give a general introduction on the mechanisms involved in organic chemiluminescence, where three basic models for excited state formation are presented. The chemiluminescence properties of 1,2-dioxetanes - four membered ring peroxides - are briefly outlined in the second part. In the main part, the mechanisms involved in the decomposition of 1,2-dioxetanes and analogous peroxides are discussed: (i) the unimolecular decomposition of 1,2-dioxetanes; (ii) the electron transfer catalyzed decomposition of peroxides by an intermolecular CIEEL (Chemically Initiated Electron Exchange Luminescence) mechanism; (iii) 1,2-dioxetane decomposition catalyzed by an intramolecular electron transfer mechanism (intramolecular CIEEL). Special emphasis is given to the latter subject, where recent examples with potential analytical applications are presented.
Resumo:
The reaction between antigen and antibody has been widely used in many strategies for the development of analytical methodology, due to its high specificity. The immuno-reaction has been successfully employed for the biosensor development. A focus on biosensor based on immunoassay coupled to amperometric transducer is presented.
Resumo:
This article describes the current status of several analytical methodologies using vegetal tissue and crude extracts as enzymatic source. In this divulgation paper the obtention of vegetal crude extract and/or tissue and selected enzymatic procedures are presented emphasizing its characteristics and peculiarities. Examples of many biosensors and/or flow injection procedures using vegetal tissues or crude extracts for the determination of many analytes, such as amines, ascorbic acid, ethanol, glutamate, hydrogen peroxide, oxalic acid, pectins, phenolic compounds and urea of biologic, environmental, food, pharmaceutical and industrial interests are also given and discussed.
Resumo:
Relevant aspects of proposed mechanisms of the chemiluminescent reaction of luminol are presented and commented to emphasize its perspectives for kinetic analysis. A careful search for analytical applications of this reaction is discussed in order to point out new trends of the studies. Kinetic analysis using the luminol reaction is proposed to be a very attractive due to the good performance of the reaction in analytical applications and the positive characteristics of kinetic analysis, such as low cost and sensibility. It is pointed out that kinetic analysis using the chemiluminescent reaction of luminol should be encouraged.