954 resultados para Drug-monitoring systems


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Nowadays, there is an increasing interest in wireless sensor networks (WSN) for environmental monitoring systems because it can be used to improve the quality of life and living conditions are becoming a major concern to people. This paper describes the design and development of a real time monitoring system based on ZigBee WSN characterized by a lower energy consumption, low cost, reduced dimensions and fast adaptation to the network tree topology. The developed system encompasses an optimized sensing process about environmental parameters, low rate transmission from sensor nodes to the gateway, packet parsing and data storing in a remote database and real time visualization through a web server.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

During recent years a consistent number of central nervous system (CNS) drugs have been approved and introduced on the market for the treatment of many psychiatric and neurological disorders, including psychosis, depression, Parkinson disease and epilepsy. Despite the great advancements obtained in the treatment of CNS diseases/disorders, partial response to therapy or treatment failure are frequent, at least in part due to poor compliance, but also genetic variability in the metabolism of psychotropic agents or polypharmacy, which may lead to sub-therapeutic or toxic plasma levels of the drugs, and finally inefficacy of the treatment or adverse/toxic effects. With the aim of improving the treatment, reducing toxic/side effects and patient hospitalisation, Therapeutic Drug Monitoring (TDM) is certainly useful, allowing for a personalisation of the therapy. Reliable analytical methods are required to determine the plasma levels of psychotropic drugs, which are often present at low concentrations (tens or hundreds of nanograms per millilitre). The present PhD Thesis has focused on the development of analytical methods for the determination of CNS drugs in biological fluids, including antidepressants (sertraline and duloxetine), antipsychotics (aripiprazole), antiepileptics (vigabatrin and topiramate) and antiparkinsons (pramipexole). Innovative methods based on liquid chromatography or capillary electrophoresis coupled to diode-array or laser-induced fluorescence detectors have been developed, together with the suitable sample pre-treatment for interference removal and fluorescent labelling in case of LIF detection. All methods have been validated according to official guidelines and applied to the analysis of real samples obtained from patients, resulting suitable for the TDM of psychotropic drugs.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Ein wichtiger Baustein für den langfristigen Erfolg einer Lebertransplantation ist die Compliance mit der lebenslang einzunehmenden immunsuppressiven Therapie. Im Rahmen der vorliegenden Arbeit wurde erstmals mittels MEMS® die Compliance bei lebertransplantierten Patienten untersucht, deren Transplantation einige Jahre zurücklag. Rekrutiert wurden Patienten, die vor 2, 5, 7 oder 10 Jahren (Gruppe 2 y.p.t., 5 y.p.t., 7 y.p.t., 10 y.p.t.) in der Universitätsmedizin Mainz lebertransplantiert wurden. 39 Patienten nahmen an der prospektiven Anwendungsbeobachtung teil. Die Compliance wurde mittels MEMS® über eine Beobachtungszeit von 6 Monaten erfasst. Bei der MEMS®-Auswertung war zu vermuten, dass 10 Patienten diese nicht wie vorgesehen verwendet hatten. Folglich konnten die mittels MEMS® gemessenen Compliance-Parameter nur für 29 Patienten valide ermittelt werden. Die mittlere Dosing Compliance betrug 81 ± 21 %, wobei die Gruppe 2 y.p.t. mit 86 ± 14 % bessere Werte zu verzeichnen hatte als die Gruppe 5 y.p.t. (75 ± 27 %) und 7 y.p.t. (74 ± 28 %). Die Ergebnisse waren jedoch nicht signifikant unterschiedlich (p=0,335, Kruskal-Wallis-Test). Unter Einbeziehung aller mittels MEMS® gemessenen Compliance-Parameter wurden 19 von 29 Patienten (66 %) als compliant eingestuft. Bei der Analyse der Gesamtcompliance basierend auf den subjektiven Compliance-Messmethoden (Morisky-Fragebogen, MESI-Fragebogen, Selbsteinschätzung), der Arzneimittel-Blutspiegel und der Anzahl an Abstoßungsreaktionen, in der alle 39 Patienten einbezogen werden konnten, wurden 35 Patienten (90 %) als compliant eingestuft. rnIm zweiten Teil der Arbeit wurde die Etablierung und Bewertung eines intersektoralen Pharmazeutischen Betreuungskonzepts für lebertransplantierte Patienten untersucht. Erstmals wurden anhand eines entwickelten schnittstellenübergreifenden, integrierten Betreuungskonzepts niedergelassene Apotheker in die Pharmazeutische Betreuung lebertransplantierter Patienten eingebunden. 20 Patienten wurden rekrutiert und während ihres stationären Aufenthaltes nach Transplantation pharmazeutisch betreut. Die Betreuung umfasste eine intensive Patientenschulung mit drei bis vier Gesprächen durch einen Krankenhausapotheker. Während des stationären Aufenthaltes wurden arzneimittelbezogene Probleme erkannt, gelöst und dokumentiert. Bei Entlassung stellte der Krankenhausapotheker einen Medikationsplan für den Hausarzt sowie für den niedergelassenen Apotheker aus und führte mit den Patienten ein ausführliches Entlassungsgespräch. Darüber hinaus wurden den Patienten Arzneimitteleinnahmepläne und eine Patienteninformation über ihr immunsuppressives Arzneimittel übergeben. 15 Patienten konnten daraufhin ambulant von niedergelassenen Apothekern pharmazeutisch weiterbetreut werden. Das kooperierende pharmazeutische Personal wurde durch ein eigens für die Studie erstelltes Manual zur Pharmazeutischen Betreuung lebertransplantierter Patienten geschult und unterstützt. Die niedergelassenen Apotheker sollten die Patienten in ihrer Arzneimitteltherapie begleiten, indem Beratungsgespräche geführt und arzneimittelbezogene Probleme erkannt und gelöst wurden. Die Nutzeffekte der intensiven Pharmazeutischen Betreuung konnte anhand verschiedener Erhebungsinstrumente dargelegt werden. Im Ergebnis resultierte eine hohe Zufriedenheit der Patienten und Apotheker mit dem Betreuungskonzept, die mittels Selbstbeurteilungsfragebögen ermittelt wurde. Die Compliance der Patienten wurde anhand des Morisky- und MESI-Fragebogens, der Selbsteinschätzung der Patienten, Blutspiegelbestimmungen sowie der Einschätzung durch den niedergelassenen Apotheker bestimmt. 86 % der Patienten wurden als compliant eingeordnet. Die Kenntnisse der Patienten über ihre immunsuppressive Therapie, welche anhand von Interviews erfragt wurden, lagen auf einem sehr hohen Niveau. Abschließend kann festgestellt werden, dass die Pharmazeutische Betreuung lebertransplantierter Patienten in den niedergelassenen Apotheken durchführbar ist. Anhand der Dokumentationsprotokolle lässt sich allerdings nur sehr schwer beurteilen, in welchem Maße die Betreuung tatsächlich erfolgte. Das tatsächliche vorliegen einer mangelnden Betreuung oder aber eine lückenhafte Dokumentation der Betreuungsleistung war nicht zu differenzieren. Ein limitierender Faktor für die intensivierte Betreuung ist sicherlich der erhebliche Aufwand für nur einen Patienten mit einem seltenen Krankheitsbild. Das Erkennen und Lösen von 48 ABP durch den Krankenhausapotheker und 32 ABP durch die niedergelassenen Apotheker, d. h. insgesamt 4,5 ABP pro Patient zeigt, dass die Pharmazeutische Betreuung einen wichtigen Beitrag für eine qualitätsgesicherte Arzneimitteltherapie leistet. Die intersektorale Pharmazeutische Betreuung stellt eine wesentliche Hilfe und Unterstützung der Patienten im sicheren Umgang mit ihrer Arzneimitteltherapie dar.rn

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Compliance lebertransplantierter Patienten mit der immunsuppressiven Therapie ist unerlässlich für den lang-fristigen Erfolg der Lebertransplantation. Aus Non-Compliance mit der immunsuppressiven Therapie können Abstoßungsreaktionen, Organverlust oder sogar Tod resultieren. Hauptziel der vorliegenden Studie war die erstmalige Evaluation der Compliance bei Einnahme von Prograf® (zweimal tägliche Einnahme von Tacrolimus) im Vergleich zur Einnahme von Advagraf® (einmal tägliche Einnahme von Tacrolimus). Von Interesse war außerdem die Fragestellung, ob sich die Compliance bezüglich der immunsuppressiven Therapie mit dem Zeitabstand zur Transplantation verändert. rnDie Compliancemessung wurde offen mittels MEMS® (Aardex Ltd., Schweiz) durchgeführt, der Patient war also über die Compliancekontrolle informiert. Mittels MEMS® konnten Datum und Uhrzeit der Dosisentnahme dokumentiert und damit zuverlässig das gesamte Compliancemuster über im Durchschnitt 176 Tage mit der zweimal täglichen Einnahme und 188 Tage mit der einmal täglichen Einnahme pro Patient erfasst werden. 65 Patienten mit dem Basisimmunsuppressivum Prograf® wurden in die prospektive, nicht-interventionelle Studie eingeschlossen und nach Per Protokoll-Analyse konnten die Daten von 63 in Mainz lebertransplantierten Patienten ausgewertet werden (Prograf®: Gruppe 1: 15 Patienten (Pat.), Gruppe 2: 23 Pat., Gruppe 3: 22 Pat., Drop-outs: 3 Pat.; Advagraf®: Gruppe 1: 16 Pat., Gruppe 2: 23 Pat., Gruppe 3: 23 Pat., Drop-outs: 1 Pat.). Die Dosing Compliance (DC), definiert als Prozent der Tage, an denen der MEMS®-Behälter korrekt geöffnet und die Dosis höchstwahrscheinlich korrekt eingenommen wurde, war der primäre Zielparameter. Weitere Methoden der Compliancemessung, wie der Pill Count, mehrere Fragebögen (Selbsteinschätzung, Patientenwissen-, Morisky-, MESI-, HADS-, SF-36- und Patientenzufriedenheit-Fragebogen) sowie die Blutspiegelmessung wurden eingesetzt, um die Compliance der Patienten umfassend charakterisieren zu können. rnDer Median der DC mit der zweimal täglichen Einnahme betrug 97% bei Pat. > 6 m.p.t. < 2 y.p.t., 97% bei Pat. > 2 y.p.t. < 5 y.p.t. und 98% bei Pat. > 5 y.p.t. (p=0,931; Kruskal-Wallis-Test). Der Median der DC von Tacroli-mus bei einmal täglicher Einnahme (Advagraf®) betrug 99% bei Pat. > 6 m.p.t. < 2 y.p.t., 98% bei Pat. > 2 y.p.t. < 5 y.p.t. und 97% bei Pat. > 5 y.p.t. (p=0,158; Kruskal-Wallis-Test). Insgesamt zeigten die Patienten während des gesamten Beobachtungszeitraums von 12 Monaten eine gute Compliance für die Einnahme ihres Immun-suppressivums. Die Timing Compliance (TiC)-raten lagen auf einem niedrigeren Niveau als die Dosing- und Taking Compliance (TC)-raten. Die Complianceraten der drei Subgruppen unterschieden sich nicht signifikant. Die Patienten mit dem geringsten Abstand zur Transplantation zeigten bei beinahe allen Messmethoden die höchste Compliance im Gegensatz zur etwas geringeren Compliance der Patienten mit größerem Abstand zur Transplantation. Die während der Advagraf®-Phase mittels MEMS® gemessenen DC-, TC- und TiC-raten fielen höher aus als bei Einnahme von Prograf® (p(DC)=0,003; p(TC)=0,077; p(TiC)=0,003; Wilcoxon Vorzeichen-Rang-Test). Dieses Ergebnis untermauert die in anderen Indikationen gefundene Complianceverbesserung durch die einmal tägliche Arzneimittelgabe im Vergleich zur zweimal täglichen Gabe. Die Auswertung der Drug Holidays ergab für die Advagraf®-Phase hingegen niedrigere Complianceraten als für die Prograf®-Phase. Dieses Ergebnis ist auf die Definition des Drug Holidays (keine Arzneimitteleinnahme über 48 h) zurück zu führen. Die Chance Advagraf® einmal pro Tag zu vergessen ist doppelt so hoch, als Prograf® dreimal aufeinander fol-gend zu vergessen. Mit einer verhältnismäßigeren Definition von Drug Holidays (Einnahmepause von 72 Stun-den bei einmal täglicher Einnahme von Advagraf® entsprechend drei ausgelassenen Dosen von Prograf®) ist die Compliancerate 81%. Die Ergebnisse des Pill Counts waren sowohl bei Einnahme von Prograf® als auch von Advagraf® mit der jeweils gemessenen TC vergleichbar, was die Zuverlässigkeit der Messergebnisse bes-tätigt. rnDie zusätzlich eingesetzten Methoden verifizierten das Ergebnis der höheren Compliance mit der einmal tägli-chen Einnahme. Die während der Advagraf®-Phase beantworteten Fragebögen zeigten einen Trend zu besserer Compliance und Lebensqualität. Lediglich die Ergebnisse des MESI-Fragebogens und der Blutspiegelmessungen wichen sowohl während der Prograf®- als auch während der Advagraf®-Phase stark von den Ergebnis-sen der anderen Methoden ab. rnUnter Einbeziehung aller mittels MEMS® und Pill Count objektiv gemessenen Complianceparameter konnten während der Prograf®-Einnahme 54 von 60 Pat. (90%) und während der Advagraf®-Phase 59 von 62 Pat. (95%) als compliant eingestuft werden. Aufgrund subjektiver Compliancemessungen waren 49 von 58 Pat. (84%) während der Prograf®- und 54 von 59 Pat. (92%) während der Advagraf®-Phase als compliant einzustufen. Es wurde beobachtet, dass die zeitlich korrekte Einnahme der Morgendosis einfacher und bei Einmalgabe zu bevorzugen ist. Die wochentagsbezogene Auswertung ergab erwartungsgemäß, dass am Wochenende (Samstag und Sonntag) am häufigsten Dosen ausgelassen wurden. rnDie Umstellung von Prograf® auf Advagraf® stellte kein Problem dar. Beinahe alle Patienten waren dankbar und zufrieden mit der Reduzierung der Dosierungsfrequenz und der größeren Unabhängigkeit durch die entfallene abendliche Einnahme. Der positive Einfluss der geringeren Dosierungshäufigkeit auf die Langzeitcompliance der Patienten, ist ein hinreichender Grund die Entwicklung von Formulierungen zur einmal täglichen Ein-nahme für weitere Immunsuppressiva zu fordern. Insbesondere bei den häufig eingesetzten Kombinationstherapien von Immunsuppressiva würde der Effekt der Complianceverbesserung noch verstärkt werden, wenn alle eingesetzten Immunsuppressiva zur einmal täglichen Gabe geeignet wären.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Makromolekulare Wirkstoffträgersysteme sind von starkem Interesse bezüglich der klinischen Anwendung chemotherapeutischer Agenzien. Um ihr klinisches Potential zu untersuchen ist es von besonderer Bedeutung das pharmakokinetische Profil in vivo zu bestimmen. Jede Veränderung der Polymerstruktur beeinflusst die Körperverteilung des entsprechenden Makromoleküls. Aufgrund dessen benötigt man detailliertes Wissen über Struktur-Eigenschaftsbeziehungen im lebenden Organismus, um das Nanocarrier System für zukünftige Anwendungen einzustellen. In dieser Beziehung stellt das präklinische Screening mittels radioaktiver Markierung und Positronen-Emissions-Tomographie eine nützliche Methode für schnelle sowie quantitative Beobachtung von Wirkstoffträgerkandidaten dar. Insbesondere poly(HPMA) und PEG sind im Arbeitsgebiet Polymer-basierter Therapeutika stark verbreitet und von ihnen abgeleitete Strukturen könnten neue Generationen in diesem Forschungsbereich bieten.rnDie vorliegende Arbeit beschreibt die erfolgreiche Synthese verschiedener HPMA und PEG basierter Polymer-Architekturen – Homopolymere, Statistische und Block copolymere – die mittels RAFT und Reaktivesterchemie durchgeführt wurde. Des Weiteren wurden die genannten Polymere mit Fluor-18 und Iod-131 radioaktiv markiert und mit Hilfe von microPET und ex vivo Biodistributionsstudien in tumortragenden Ratten biologisch evaluiert. Die Variation in Polymer-Architektur und darauffolgende Analyse in vivo resultierte in wichtige Schlussfolgerungen. Das hydrophile / lipophile Gleichgewicht hatte einen bedeutenden Einfluss auf das pharmakokinetische Profil, mit besten in vivo Eigenschaften (geringe Aufnahme in Leber und Milz sowie verlängerte Blutzirkulationszeit) für statistische HPMA-LMA copolymere mit steigendem hydrophoben Anteil. Außerdem zeigten Langzeitstudien mit Iod-131 eine verstärkte Retention von hochmolekularen, HPMA basierten statistischen Copolymeren im Tumorgewebe. Diese Beobachtung bestätigte den bekannten EPR-Effekt. Hinzukommend stellen Überstrukturbildung und damit Polymergröße Schlüsselfaktoren für effizientes Tumor-Targeting dar, da Polymerstrukturen über 200 nm in Durchmesser schnell vom MPS erkannt und vom Blutkreislauf eliminiert werden. Aufgrund dessen wurden die hier synthetisierten HPMA Block copolymere mit PEG Seitengruppen chemisch modifiziert, um eine Verminderung in Größe sowie eine Reduktion in Blutausscheidung zu induzieren. Dieser Ansatz führte zu einer erhöhten Tumoranreicherung im Walker 256 Karzinom Modell. Generell wird die Körperverteilung von HPMA und PEG basierten Polymeren stark durch die Polymer-Architektur sowie das Molekulargewicht beeinflusst. Außerdem hängt ihre Effizienz hinsichtlich Tumorbehandlung deutlich von den individuellen Charakteristika des einzelnen Tumors ab. Aufgrund dieser Beobachtungen betont die hier vorgestellte Dissertation die Notwendigkeit einer detaillierten Polymer-Charakterisierung, kombiniert mit präklinischem Screening, um polymere Wirkstoffträgersysteme für individualisierte Patienten-Therapie in der Zukunft maßzuschneidern.rn

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Patienten, die an Osteosarkom leiden werden derzeit mit intravenös applizierten krebstherapeutischen Mitteln nach Tumorresektion behandelt, was oftmals mit schweren Nebenwirkungen und einem verzögerten Knochenheilungsprozess einhergeht. Darüber hinaus treten vermehrt Rezidive aufgrund von verbleibenden neoplastischen Zellen an der Tumorresektionsstelle auf. Erfolgreiche Knochenregeneration und die Kontrolle von den im Gewebe verbleibenden Krebszellen stellt eine Herausforderung für das Tissue Engineering nach Knochenverlust durch Tumorentfernung dar. In dieser Hinsicht scheint der Einsatz von Hydroxyapatit als Knochenersatzmaterial in Kombination mit Cyclodextrin als Medikamententräger, vielversprechend. Chemotherapeutika können an Biomaterial gebunden und direkt am Tumorbett über einen längeren Zeitraum freigesetzt werden, um verbliebene neoplastische Zellen zu eliminieren. Lokal applizierte Chemotherapie hat diverse Vorteile, einschließlich der direkten zytotoxischen Auswirkung auf lokale Zellen, sowie die Reduzierung schwerer Nebenwirkungen. Diese Studie wurde durchgeführt, um die Funktionsfähigkeit eines solchen Arzneimittelabgabesystems zu bewerten und um Strategien im Bereich des Tissue Engineerings zu entwickeln, die den Knochenheilungsprozess und im speziellen die Vaskularisierung fördern sollen. Die Ergebnisse zeigen, dass nicht nur Krebszellen von der chemotherapeutischen Behandlung betroffen sind. Primäre Endothelzellen wie zum Beispiel HUVEC zeigten eine hohe Sensibilität Cisplatin und Doxorubicin gegenüber. Beide Medikamente lösten in HUVEC ein tumor-unterdrückendes Signal durch die Hochregulation von p53 und p21 aus. Zudem scheint Hypoxie einen krebstherapeutischen Einfluss zu haben, da die Behandlung sensitiver HUVEC mit Hypoxie die Zellen vor Zytotoxizität schützte. Der chemo-protektive Effekt schien deutlich weniger auf Krebszelllinien zu wirken. Diese Resultate könnten eine mögliche chemotherapeutische Strategie darstellen, um den Effekt eines zielgerichteten Medikamenteneinsatzes auf Krebszellen zu verbessern unter gleichzeitiger Schonung gesunder Zellen. Eine erfolgreiche Integration eines Systems, das Arzneimittel abgibt, kombiniert mit einem Biomaterial zur Stabilisierung und Regeneration, könnte gesunden Endothelzellen die Möglichkeit bieten zu proliferieren und Blutgefäße zu bilden, während verbleibende Krebszellen eliminiert werden. Da der Prozess der Knochengeweberemodellierung mit einer starken Beeinträchtigung der Lebensqualität des Patienten einhergeht, ist die Beschleunigung des postoperativen Heilungsprozesses eines der Ziele des Tissue Engineerings. Die Bildung von Blutgefäßen ist unabdingbar für eine erfolgreiche Integration eines Knochentransplantats in das Gewebe. Daher ist ein umfangreich ausgebildetes Blutgefäßsystem für einen verbesserten Heilungsprozess während der klinischen Anwendung wünschenswert. Frühere Experimente zeigen, dass sich die Anwendung von Ko-Kulturen aus humanen primären Osteoblasten (pOB) und humanen outgrowth endothelial cells (OEC) im Hinblick auf die Bildung stabiler gefäßähnlicher Strukturen in vitro, die auch effizient in das mikrovaskuläre System in vivo integriert werden konnten, als erfolgreich erweisen. Dieser Ansatz könnte genutzt werden, um prä-vaskularisierte Konstrukte herzustellen, die den Knochenheilungsprozess nach der Implantation fördern. Zusätzlich repräsentiert das Ko-Kultursystem ein exzellentes in vitro Model, um Faktoren, welche stark in den Prozess der Knochenheilung und Angiogenese eingebunden sind, zu identifizieren und zu analysieren. Es ist bekannt, dass Makrophagen eine maßgebliche Rolle in der inflammatorisch-induzierten Angiogenese spielen. In diesem Zusammenhang hebt diese Studie den positiven Einfluss THP-1 abgeleiteter Makrophagen in Ko-Kultur mit pOB und OEC hervor. Die Ergebnisse zeigten, dass die Anwendung von Makrophagen als inflammatorischer Stimulus im bereits etablierten Ko-Kultursystem zu einer pro-angiogenen Aktivierung der OEC führte, was in einer signifikant erhöhten Bildung blutgefäßähnlicher Strukturen in vitro resultierte. Außerdem zeigte die Analyse von Faktoren, die in der durch Entzündung hervorgerufenen Angiogenese eine wichtige Rolle spielen, eine deutliche Hochregulation von VEGF, inflammatorischer Zytokine und Adhäsionsmoleküle, die letztlich zu einer verstärkten Vaskularisierung beitragen. Diese Resultate werden dem Einfluss von Makrophagen zugeschrieben und könnten zukünftig im Tissue Engineering eingesetzt werden, um den Heilungsprozess zu beschleunigen und damit die klinische Situation von Patienten zu verbessern. Darüber hinaus könnte die Kombination der auf Ko-Kulturen basierenden Ansätze für das Knochen Tissue Engineering mit einem biomaterial-basierenden Arzneimittelabgabesystem zum klinischen Einsatz kommen, der die Eliminierung verbliebener Krebszellen mit der Förderung der Knochenregeneration verbindet.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In orthopaedic and dental implantology, novel tools and techniques are being sought to improve the regeneration of bone tissue. Numerous attempts have been made to enhance the osteoconductivity of titanium prostheses, including modifications in their surface properties and coating with layers of calcium phosphate. The technique whereby such layers are produced has recently undergone a revolutionary change, which has had profound consequences for their potential to serve as drug-carrier systems. Hitherto, calcium phosphate layers were deposited upon the surfaces of metal implants under highly unphysiological physical conditions, which precluded the incorporation of proteinaceous osteoinductive drugs. These agents could only be adsorbed, superficially, upon preformed layers. Such superficially adsorbed molecules are released too rapidly within a biological milieu to be effective in their osteoinductive capacity. Now, it is possible to deposit calcium phosphate layers under physiological conditions of temperature and pH by the so-called biomimetic process, during which bioactive agents can be coprecipitated. Since these molecules are integrated into the inorganic latticework, they are released gradually in vivo as the layer undergoes degradation. This feature enhances the capacity of these coatings to act as a carrier system for osteogenic agents.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE This study assessed whether a cycle of "routine" therapeutic drug monitoring (TDM) for imatinib dosage individualization, targeting an imatinib trough plasma concentration (C min) of 1,000 ng/ml (tolerance: 750-1,500 ng/ml), could improve clinical outcomes in chronic myelogenous leukemia (CML) patients, compared with TDM use only in case of problems ("rescue" TDM). METHODS Imatinib concentration monitoring evaluation was a multicenter randomized controlled trial including adult patients in chronic or accelerated phase CML receiving imatinib since less than 5 years. Patients were allocated 1:1 to "routine TDM" or "rescue TDM." The primary endpoint was a combined outcome (failure- and toxicity-free survival with continuation on imatinib) over 1-year follow-up, analyzed in intention-to-treat (ISRCTN31181395). RESULTS Among 56 patients (55 evaluable), 14/27 (52 %) receiving "routine TDM" remained event-free versus 16/28 (57 %) "rescue TDM" controls (P = 0.69). In the "routine TDM" arm, dosage recommendations were correctly adopted in 14 patients (median C min: 895 ng/ml), who had fewer unfavorable events (28 %) than the 13 not receiving the advised dosage (77 %; P = 0.03; median C min: 648 ng/ml). CONCLUSIONS This first target concentration intervention trial could not formally demonstrate a benefit of "routine TDM" because of small patient number and surprisingly limited prescriber's adherence to dosage recommendations. Favorable outcomes were, however, found in patients actually elected for target dosing. This study thus shows first prospective indication for TDM being a useful tool to guide drug dosage and shift decisions. The study design and analysis provide an interesting paradigm for future randomized TDM trials on targeted anticancer agents.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Current nanometer technologies suffer within-die parameter uncertainties, varying workload conditions, aging, and temperature effects that cause a serious reduction on yield and performance. In this scenario, monitoring, calibration, and dynamic adaptation become essential, demanding systems with a collection of multi purpose monitors and exposing the need for light-weight monitoring networks. This paper presents a new monitoring network paradigm able to perform an early prioritization of the information. This is achieved by the introduction of a new hierarchy level, the threshing level. Targeting it, we propose a time-domain signaling scheme over a single-wire that minimizes the network switching activity as well as the routing requirements. To validate our approach, we make a thorough analysis of the architectural trade-offs and expose two complete monitoring systems that suppose an area improvement of 40% and a power reduction of three orders of magnitude compared to previous works.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

La temperatura es una preocupación que juega un papel protagonista en el diseño de circuitos integrados modernos. El importante aumento de las densidades de potencia que conllevan las últimas generaciones tecnológicas ha producido la aparición de gradientes térmicos y puntos calientes durante el funcionamiento normal de los chips. La temperatura tiene un impacto negativo en varios parámetros del circuito integrado como el retardo de las puertas, los gastos de disipación de calor, la fiabilidad, el consumo de energía, etc. Con el fin de luchar contra estos efectos nocivos, la técnicas de gestión dinámica de la temperatura (DTM) adaptan el comportamiento del chip en función en la información que proporciona un sistema de monitorización que mide en tiempo de ejecución la información térmica de la superficie del dado. El campo de la monitorización de la temperatura en el chip ha llamado la atención de la comunidad científica en los últimos años y es el objeto de estudio de esta tesis. Esta tesis aborda la temática de control de la temperatura en el chip desde diferentes perspectivas y niveles, ofreciendo soluciones a algunos de los temas más importantes. Los niveles físico y circuital se cubren con el diseño y la caracterización de dos nuevos sensores de temperatura especialmente diseñados para los propósitos de las técnicas DTM. El primer sensor está basado en un mecanismo que obtiene un pulso de anchura variable dependiente de la relación de las corrientes de fuga con la temperatura. De manera resumida, se carga un nodo del circuito y posteriormente se deja flotando de tal manera que se descarga a través de las corrientes de fugas de un transistor; el tiempo de descarga del nodo es la anchura del pulso. Dado que la anchura del pulso muestra una dependencia exponencial con la temperatura, la conversión a una palabra digital se realiza por medio de un contador logarítmico que realiza tanto la conversión tiempo a digital como la linealización de la salida. La estructura resultante de esta combinación de elementos se implementa en una tecnología de 0,35 _m. El sensor ocupa un área muy reducida, 10.250 nm2, y consume muy poca energía, 1.05-65.5nW a 5 muestras/s, estas cifras superaron todos los trabajos previos en el momento en que se publicó por primera vez y en el momento de la publicación de esta tesis, superan a todas las implementaciones anteriores fabricadas en el mismo nodo tecnológico. En cuanto a la precisión, el sensor ofrece una buena linealidad, incluso sin calibrar; se obtiene un error 3_ de 1,97oC, adecuado para tratar con las aplicaciones de DTM. Como se ha explicado, el sensor es completamente compatible con los procesos de fabricación CMOS, este hecho, junto con sus valores reducidos de área y consumo, lo hacen especialmente adecuado para la integración en un sistema de monitorización de DTM con un conjunto de monitores empotrados distribuidos a través del chip. Las crecientes incertidumbres de proceso asociadas a los últimos nodos tecnológicos comprometen las características de linealidad de nuestra primera propuesta de sensor. Con el objetivo de superar estos problemas, proponemos una nueva técnica para obtener la temperatura. La nueva técnica también está basada en las dependencias térmicas de las corrientes de fuga que se utilizan para descargar un nodo flotante. La novedad es que ahora la medida viene dada por el cociente de dos medidas diferentes, en una de las cuales se altera una característica del transistor de descarga |la tensión de puerta. Este cociente resulta ser muy robusto frente a variaciones de proceso y, además, la linealidad obtenida cumple ampliamente los requisitos impuestos por las políticas DTM |error 3_ de 1,17oC considerando variaciones del proceso y calibrando en dos puntos. La implementación de la parte sensora de esta nueva técnica implica varias consideraciones de diseño, tales como la generación de una referencia de tensión independiente de variaciones de proceso, que se analizan en profundidad en la tesis. Para la conversión tiempo-a-digital, se emplea la misma estructura de digitalización que en el primer sensor. Para la implementación física de la parte de digitalización, se ha construido una biblioteca de células estándar completamente nueva orientada a la reducción de área y consumo. El sensor resultante de la unión de todos los bloques se caracteriza por una energía por muestra ultra baja (48-640 pJ) y un área diminuta de 0,0016 mm2, esta cifra mejora todos los trabajos previos. Para probar esta afirmación, se realiza una comparación exhaustiva con más de 40 propuestas de sensores en la literatura científica. Subiendo el nivel de abstracción al sistema, la tercera contribución se centra en el modelado de un sistema de monitorización que consiste de un conjunto de sensores distribuidos por la superficie del chip. Todos los trabajos anteriores de la literatura tienen como objetivo maximizar la precisión del sistema con el mínimo número de monitores. Como novedad, en nuestra propuesta se introducen nuevos parámetros de calidad aparte del número de sensores, también se considera el consumo de energía, la frecuencia de muestreo, los costes de interconexión y la posibilidad de elegir diferentes tipos de monitores. El modelo se introduce en un algoritmo de recocido simulado que recibe la información térmica de un sistema, sus propiedades físicas, limitaciones de área, potencia e interconexión y una colección de tipos de monitor; el algoritmo proporciona el tipo seleccionado de monitor, el número de monitores, su posición y la velocidad de muestreo _optima. Para probar la validez del algoritmo, se presentan varios casos de estudio para el procesador Alpha 21364 considerando distintas restricciones. En comparación con otros trabajos previos en la literatura, el modelo que aquí se presenta es el más completo. Finalmente, la última contribución se dirige al nivel de red, partiendo de un conjunto de monitores de temperatura de posiciones conocidas, nos concentramos en resolver el problema de la conexión de los sensores de una forma eficiente en área y consumo. Nuestra primera propuesta en este campo es la introducción de un nuevo nivel en la jerarquía de interconexión, el nivel de trillado (o threshing en inglés), entre los monitores y los buses tradicionales de periféricos. En este nuevo nivel se aplica selectividad de datos para reducir la cantidad de información que se envía al controlador central. La idea detrás de este nuevo nivel es que en este tipo de redes la mayoría de los datos es inútil, porque desde el punto de vista del controlador sólo una pequeña cantidad de datos |normalmente sólo los valores extremos| es de interés. Para cubrir el nuevo nivel, proponemos una red de monitorización mono-conexión que se basa en un esquema de señalización en el dominio de tiempo. Este esquema reduce significativamente tanto la actividad de conmutación sobre la conexión como el consumo de energía de la red. Otra ventaja de este esquema es que los datos de los monitores llegan directamente ordenados al controlador. Si este tipo de señalización se aplica a sensores que realizan conversión tiempo-a-digital, se puede obtener compartición de recursos de digitalización tanto en tiempo como en espacio, lo que supone un importante ahorro de área y consumo. Finalmente, se presentan dos prototipos de sistemas de monitorización completos que de manera significativa superan la características de trabajos anteriores en términos de área y, especialmente, consumo de energía. Abstract Temperature is a first class design concern in modern integrated circuits. The important increase in power densities associated to recent technology evolutions has lead to the apparition of thermal gradients and hot spots during run time operation. Temperature impacts several circuit parameters such as speed, cooling budgets, reliability, power consumption, etc. In order to fight against these negative effects, dynamic thermal management (DTM) techniques adapt the behavior of the chip relying on the information of a monitoring system that provides run-time thermal information of the die surface. The field of on-chip temperature monitoring has drawn the attention of the scientific community in the recent years and is the object of study of this thesis. This thesis approaches the matter of on-chip temperature monitoring from different perspectives and levels, providing solutions to some of the most important issues. The physical and circuital levels are covered with the design and characterization of two novel temperature sensors specially tailored for DTM purposes. The first sensor is based upon a mechanism that obtains a pulse with a varying width based on the variations of the leakage currents on the temperature. In a nutshell, a circuit node is charged and subsequently left floating so that it discharges away through the subthreshold currents of a transistor; the time the node takes to discharge is the width of the pulse. Since the width of the pulse displays an exponential dependence on the temperature, the conversion into a digital word is realized by means of a logarithmic counter that performs both the timeto- digital conversion and the linearization of the output. The structure resulting from this combination of elements is implemented in a 0.35_m technology and is characterized by very reduced area, 10250 nm2, and power consumption, 1.05-65.5 nW at 5 samples/s, these figures outperformed all previous works by the time it was first published and still, by the time of the publication of this thesis, they outnumber all previous implementations in the same technology node. Concerning the accuracy, the sensor exhibits good linearity, even without calibration it displays a 3_ error of 1.97oC, appropriate to deal with DTM applications. As explained, the sensor is completely compatible with standard CMOS processes, this fact, along with its tiny area and power overhead, makes it specially suitable for the integration in a DTM monitoring system with a collection of on-chip monitors distributed across the chip. The exacerbated process fluctuations carried along with recent technology nodes jeop-ardize the linearity characteristics of the first sensor. In order to overcome these problems, a new temperature inferring technique is proposed. In this case, we also rely on the thermal dependencies of leakage currents that are used to discharge a floating node, but now, the result comes from the ratio of two different measures, in one of which we alter a characteristic of the discharging transistor |the gate voltage. This ratio proves to be very robust against process variations and displays a more than suficient linearity on the temperature |1.17oC 3_ error considering process variations and performing two-point calibration. The implementation of the sensing part based on this new technique implies several issues, such as the generation of process variations independent voltage reference, that are analyzed in depth in the thesis. In order to perform the time-to-digital conversion, we employ the same digitization structure the former sensor used. A completely new standard cell library targeting low area and power overhead is built from scratch to implement the digitization part. Putting all the pieces together, we achieve a complete sensor system that is characterized by ultra low energy per conversion of 48-640pJ and area of 0.0016mm2, this figure outperforms all previous works. To prove this statement, we perform a thorough comparison with over 40 works from the scientific literature. Moving up to the system level, the third contribution is centered on the modeling of a monitoring system consisting of set of thermal sensors distributed across the chip. All previous works from the literature target maximizing the accuracy of the system with the minimum number of monitors. In contrast, we introduce new metrics of quality apart form just the number of sensors; we consider the power consumption, the sampling frequency, the possibility to consider different types of monitors and the interconnection costs. The model is introduced in a simulated annealing algorithm that receives the thermal information of a system, its physical properties, area, power and interconnection constraints and a collection of monitor types; the algorithm yields the selected type of monitor, the number of monitors, their position and the optimum sampling rate. We test the algorithm with the Alpha 21364 processor under several constraint configurations to prove its validity. When compared to other previous works in the literature, the modeling presented here is the most complete. Finally, the last contribution targets the networking level, given an allocated set of temperature monitors, we focused on solving the problem of connecting them in an efficient way from the area and power perspectives. Our first proposal in this area is the introduction of a new interconnection hierarchy level, the threshing level, in between the monitors and the traditional peripheral buses that applies data selectivity to reduce the amount of information that is sent to the central controller. The idea behind this new level is that in this kind of networks most data are useless because from the controller viewpoint just a small amount of data |normally extreme values| is of interest. To cover the new interconnection level, we propose a single-wire monitoring network based on a time-domain signaling scheme that significantly reduces both the switching activity over the wire and the power consumption of the network. This scheme codes the information in the time domain and allows a straightforward obtention of an ordered list of values from the maximum to the minimum. If the scheme is applied to monitors that employ TDC, digitization resource sharing is achieved, producing an important saving in area and power consumption. Two prototypes of complete monitoring systems are presented, they significantly overcome previous works in terms of area and, specially, power consumption.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

There is now an emerging need for an efficient modeling strategy to develop a new generation of monitoring systems. One method of approaching the modeling of complex processes is to obtain a global model. It should be able to capture the basic or general behavior of the system, by means of a linear or quadratic regression, and then superimpose a local model on it that can capture the localized nonlinearities of the system. In this paper, a novel method based on a hybrid incremental modeling approach is designed and applied for tool wear detection in turning processes. It involves a two-step iterative process that combines a global model with a local model to take advantage of their underlying, complementary capacities. Thus, the first step constructs a global model using a least squares regression. A local model using the fuzzy k-nearest-neighbors smoothing algorithm is obtained in the second step. A comparative study then demonstrates that the hybrid incremental model provides better error-based performance indices for detecting tool wear than a transductive neurofuzzy model and an inductive neurofuzzy model.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Resumen de la comunicación presentada en PIC2015 – the 14th International Congress on Combustion By-Products and Their Health Effects, Umeå, Sweden, 14-17 June 2015.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Information technologies (IT) currently represent 2% of CO2 emissions. In recent years, a wide variety of IT solutions have been proposed, focused on increasing the energy efficiency of network data centers. Monitoring is one of the fundamental pillars of these systems, providing the information necessary for adequate decision making. However, today’s monitoring systems (MSs) are partial, specific and highly coupled solutions. This study proposes a model for monitoring data centers that serves as a basis for energy saving systems, offered as a value-added service embedded in a device with low cost and power consumption. The proposal is general in nature, comprehensive, scalable and focused on heterogeneous environments, and it allows quick adaptation to the needs of changing and dynamic environments. Further, a prototype of the system has been implemented in several devices, which has allowed validation of the proposal in addition to identification of the minimum hardware profile required to support the model.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper presents an overview of the role and responsibilities of the system administrator, focusing on the need to monitor its technological infrastructure. The informatics infrastructure monitoring is, nowadays without a doubt, one of the main key points in business support. Large enterprises are no longer the only ones to feel the need to use these monitoring tools, but small and medium-sized enterprises, which also have IT environments of an increasing complexity, feel such a need. This results directly from the operation of how the business is supported on IT platforms as support for people and processes. When a system, which is vital to the organization, fails either at the hardware or software level, compromises the operating capacity and consequently the business continuity. Having this always in mind, it is extremely important to adopt monitoring systems that proactively or reactively, reduce the overall time of breaks caused by failures. A monitoring system is the way to ensure confidence in all components and the operational readiness of IT infrastructure.