913 resultados para Disc prolapse, Disc failure, Disc degeneration, Complex loading, Finite element analysis
Resumo:
Lumbar discectomy is the surgical procedure most frequently performed for patients suffering from low back pain and sciatica. Disc herniation as a consequence of degenerative or traumatic processes is commonly encountered as the underlying cause for the painful condition. While discectomy provides favourable outcome in a majority of cases, there are conditions where unmet requirements exist in terms of treatment, such as large disc protrusions with minimal disc degeneration; in these cases, the high rate of recurrent disc herniation after discectomy is a prevalent problem. An effective biological annular repair could improve the surgical outcome in patients with contained disc herniations but otherwise minor degenerative changes. An attractive approach is a tissue-engineered implant that will enable/stimulate the repair of the ruptured annulus. The strategy is to develop three-dimensional scaffolds and activate them by seeding cells or by incorporating molecular signals that enable new matrix synthesis at the defect site, while the biomaterial provides immediate closure of the defect and maintains the mechanical properties of the disc. This review is structured into (1) introduction, (2) clinical problems, current treatment options and needs, (3) biomechanical demands, (4) cellular and extracellular components, (5) biomaterials for delivery, scaffolding and support, (6) pre-clinical models for evaluation of newly developed cell- and material-based therapies, and (7) conclusions. This article highlights that an interdisciplinary approach is necessary for successful development of new clinical methods for annulus fibrosus repair. This will benefit from a close collaboration between research groups with expertise in all areas addressed in this review.
Resumo:
PURPOSE We tested the hypothesis that whiplash trauma leads to changes of the signal intensity of cervical discs in T2-weighted images. METHODS AND MATERIALS 50 whiplash patients (18-65 years) were examined within 48h after motor vehicle accident, and again after 3 and 6 months and compared to 50 age- and sex-matched controls. Signal intensity in ROI's of the discs at the levels C2/3 to C7/T1 and the adjacent vertebral bodies were measured on sagittal T2 weighted MR images and normalized using the average of ROI's in fat tissue. The contrast between discs and both adjacent vertebrae was calculated and disc degeneration was graded by the Pfirrmann-grading system. RESULTS Whiplash trauma did not have a significant effect on the normalized signals from discs and vertebrae, on the contrast between discs and adjacent vertebrae, or on the Pfirrmann grading. However, the contrast between discs and adjacent vertebrae and the Pfirrmann grading showed a strong correlation. In healthy volunteers, the contrast between discs and adjacent vertebrae and Pfirrmann grading increased with age and was dependent on the disc level. CONCLUSION We could not find any trauma related changes of cervical disc signal intensities. Normalized signals of discs and Pfirrmann grading changed with age and varied between disc levels with the used MR sequence.
CCL5/RANTES is a key chemoattractant released by degenerative intervertebral discs in organ culture.
Resumo:
Release of chemotactic factors in response to tissue damage has been described for different musculoskeletal tissues, including the intervertebral disc (IVD). This study investigated the chemoattractants that are released by induced degenerative IVDs and may be involved in recruiting mesenchymal stem cells (MSCs). Bovine caudal discs were cultured within a bioreactor and loaded under conditions that mimicked physiological or degenerative settings. Between days 4-6, medium was replaced by PBS, which was subsequently used for proteomic, ELISA and immunoprecipitation analyses of secreted chemokines and cytokines. A Boyden chamber assay was used to observe human MSC migration towards native and chemokine depleted media. Gene expression levels of chemokine receptors in human MSCs were analysed, and CCL5 was localised in bovine and human IVD by immunohistochemistry. Proteomic analysis revealed the presence of CCL5 and CXCL6 within conditioned media. Higher concentrations of CCL5 were found in the degenerative media, and a relationship was found between interleukin-1β and CCL5 concentration. Chemokine immunoprecipitation showed that MSCs had a significantly reduced chemotactic migration towards CCL5-immunoprecipitated and CCL5/CXCL6 co-immunoprecipitated media, whilst CXCL6 depletion did not change MSC chemotaxis. MSCs showed a significant increase in mRNA expression of the CCL5 receptors, CCR1 and CCR4, upon culture in degenerative media. Furthermore, CCL5 was identified in bovine and human disc tissue by immunohistochemistry. Hence, CCL5 may be a key chemoattractant that is produced and released by the intervertebral disc cells. Therefore, these factors could be used to enhance stem/progenitor cell mobilisation in regenerative therapies for early stages of disc degeneration.
Resumo:
Recurrent intervertebral disc (IVD) herniation and degenerative disc disease have been identified as the most important factors contributing to persistent pain and disability after surgical discectomy. An annulus fibrosus (AF) closure device that provides immediate closure of the AF rupture, restores disc height, reduces further disc degeneration and enhances self-repair capacities is an unmet clinical need. In this study, a poly(trimethylene carbonate) (PTMC) scaffold seeded with human bone marrow derived mesenchymal stromal cells (MSCs) and covered with a poly(ester-urethane) (PU) membrane was assessed for AF rupture repair in a bovine organ culture annulotomy model under dynamic load for 14 days. PTMC scaffolds combined with the sutured PU membrane restored disc height of annulotomized discs and prevented herniation of nucleus pulposus (NP) tissue. Implanted MSCs showed an up-regulated gene expression of type V collagen, a potential AF marker, indicating in situ differentiation capability. Furthermore, MSCs delivered within PTMC scaffolds induced an up-regulation of anabolic gene expression and down-regulation of catabolic gene expression in adjacent native disc tissue. In conclusion, the combined biomaterial and cellular approach has the potential to hinder herniation of NP tissue, stabilize disc height, and positively modulate cell phenotype of native disc tissue.
Resumo:
La transformación de la energía cinética del mar en una fuente renovable de energía eléctrica podría ser un hecho relevante desde el punto de visto tecnológico en un futuro cercano. En el campo de las energías renovables marinas, las turbinas de corrientes de eje horizontal son posiblemente el dispositivo más adecuado para la obtención de electricidad. Las técnicas de cálculo existentes en la actualidad para obtener las distribuciones de cargas a las que está sometida una pala de una turbina de corrientes son las siguientes: Modelos de disco actuador, Método de líneas sustentadoras y método de elementos finitos. Estas técnicas presentan ciertas dificultades para su implementación y obtención de resultados preliminares, ya que entrañan gran complejidad conceptual y su entendimiento no resulta sencillo ni tampoco elaborar procedimientos de cálculo que se puedan utilizar durante la fase de diseño conceptual o básico de una turbina. En este trabajo, se analizarán los conceptos físicos y matemáticos que intervienen en el funcionamiento de una turbina de corrientes, para confeccionar un método o procedimiento de cálculo que sea relativamente intuitivo y sencillo de manejar. Esta herramienta de cálculo permitirá obtener resultados para el diseño básico, y también puede ser un punto de partida para manejar otras herramientas de cálculo más avanzadas ya que los principios fundamentales son los mismos. En la parte final del trabajo se aplicarán las ecuaciones obtenidas a varios casos reales de turbinas de corrientes. ABSTRACT Transforming the kinetic energy of the sea into renewable useful source electricity could be a relevant technologic development in the near future. In this field, marine horizontal axis turbines (HAT) are possibly, the most important devices. The current calculation techniques used to obtain the acting forces or loads in the marine current horizontal axis rotor blades: Actuator disc models, lifting lines and finite element method, have certain disadvantages which lead difficulties to obtain relatively quick results, in addition, these methods are not easy to understand and mastering, and furthermore, complex computing tools are required to obtain results. In the present work, the common physical and mathematic fundamentals will be studied and analyzed with the aim to create a new easier managing calculating tool. The proposed procedure of this document can be considered as a help towards to calculate preliminary solutions easier, and also a starting point to manage physical ideas which could be used with other calculation tools. And finally, the mathematic fundamentals will be explained and the implementation of the equations in a real case. Nevertheless, due to the real complexity of the problem, the assumed simplifications of this model must be taken into account, in order to know the possible calculating limitations of this procedure and consequently use it correctly.
Resumo:
Introduction: Lower back pain treatment and compensation costs >$80 billion overall in the US. 75% of back pain is due to disc degeneration in the lumbar region of the spine. Current treatment comprises of painkillers and bed rest or as a more radical solution – interbody cage fusion. In the early stages of disc degeneration the patient would benefit from addition of an injectable gel which polymerises in situ to support the degenerated nucleus pulposus. This involves a material which is an analogue of the natural tissue capable of restoring the biomechanical properties of the natural disc. The nucleus pulposus of the intervertebral disc is an example of a natural proteoglycan consisting of a protein core with negatively charged keratin and chondroitin sulphate attached. As a result of the high fixed charge density of the proteoglycan, the matrix exerts an osmotic swelling pressure drawing sufficient water into support the spinal system. Materials and Methods: NaAMPs (sodium 2- acrylamido 2-methyl propane sulphonic acid) and KSPA (potassium 3- sulphopropyl acrylate) were selected as monomers, the sulphonate group being used to mimic the natural sulphate group. These are used in dermal applications involving chronic wounds and have acceptably low cytotoxicity. Other hydrophilic carboxyl, amide and hydroxyl monomers such as 2-hydroxyethyl acrylamide, ß-carboxyethyl acrylate, acryloyl morpholine, and polyethylene glycol (meth)acrylate were used as diluents together with polyethyleneglycol di(meth)acrylate and hydrophilic multifunctional macromers as cross-linker. Redox was the chosen method of polymerisation and a range of initiators were investigated. Components were packaged in two solutions each containing a redox pair. A dual syringe method of injection into the cavity was used, the required time for polymerisation is circa 3-7 minutes. The final materials were tested using a Bohlin CVO Rheometer cycling from 0.5-25Hz at 37oC to measure the modulus. An in-house compression testing method was developed, using dialysis tubing to mimic the cavity, the gels were swelled in solutions of various osmolarity and compressed to ~ 20%. The pre-gel has also been injected into sheep spinal segments for mechanical compression testing to demonstrate the restoration of properties upon use of the gel. Results and Discussion: Two systems resulted using similar monomer compositions but different initiation and crosslinking agents. NaAMPs and KSPA were used together at a ratio of ~1:1 in both systems with 0.25-2% crosslinking agent, diacrylate or methacrylate. The two initiation systems were ascorbic acid/oxone, and N,N,N,N - tetramethylethylenediamine (TEMED)/ potassium persulphate. These systems produced gelation within 3-7 and 3-5 minutes respectively. Storage of the two component systems was shown to be stable for approximately one month after mixing, in the dark, refrigerated at 1-4oC. The gelation was carried out at 37oC. Literature values for the natural disc give elastic constants ranging from 3-8kPa. The properties of the polymer can be tailored by altering crosslink density and monomer composition and are able to match those of the natural disc. It is possible to incorporate a radio-opaque (histodenz) to enable x-ray luminescence during and after injection. At an inclusion level of 5% the gel is clearly visible and polymerisation and mechanical properties are not altered. Conclusion: A two-pac injection system which will polymerise in situ, that can incorporate a radio-opaque, has been developed. This will reinforce the damaged nucleus pulposus in degenerative disc disease restoring adequate hydration and thus biomechanical properties. Tests on sheep spine segments are currently being carried out to demonstrate that a disc containing the gel has similar properties to an intact disc in comparison to one with a damaged nucleus.
Resumo:
Background: The ageing population, with concomitant increase in chronic conditions, is increasing the presence of older people with complex needs in hospital. People with dementia are one of these complex populations and are particularly vulnerable to complications in hospital. Registered nurses can offer simultaneous assessment and intervention to prevent or mitigate hospital-acquired complications through their skilled brokerage between patient needs and hospital functions. A range of patient outcome measures that are sensitive to nursing care has been tested in nursing work environments across the world. However, none of these measures have focused on hospitalised older patients. Method: This thesis explores nursing-sensitive complications for older patients with and without dementia using an internationally recognised, risk-adjusted patient outcome approach. Specifically explored are: the differences between rates of complications; the costs of complications; and cost comparisons of patient complexity. A retrospective cohort study of an Australian state’s 2006–07 public hospital discharge data was utilised to identify patient episodes for people over age 50 (N=222,440) where dementia was identified as a primary or secondary diagnosis (N=44,422). Extra costs for patient episodes were estimated based on length of stay (LOS) above the average for each patient’s Diagnosis Related Group (DRG) (N=157,178) and were modelled using linear regression analysis to establish the strongest patient complexity predictors of cost. Results: Hospitalised patients with a primary or secondary diagnosis of dementia had higher rates of complications than did their same-age peers. The highest rates and relative risk for people with dementia were found in four key complications: urinary tract infections; pressure injuries; pneumonia, and delirium. While 21.9% of dementia patients (9,751/44,488, p<0.0001) suffered a complication, only 8.8% of non-dementia patients did so (33,501/381,788, p<0.0001), giving dementia patients a 2.5 relative risk of acquiring a complication (p<0.0001). These four key complications in patients over 50 both with and without dementia were associated with an eightfold increase in length of stay (813%, or 3.6 days/0.4 days) and double the increased estimated mean episode cost (199%, or A$16,403/ A$8,240). These four complications were associated with 24.7% of the estimated cost of additional days spent in hospital in 2006–07 in NSW (A$226million/A$914million). Dementia patients accounted for 22.0% of these costs (A$49million/A$226million) even though they were only 10.4% of the population (44,488/426,276 episodes). Hospital-acquired complications, particularly for people with a comorbidity of dementia, cost more than other kinds of inpatient complexity but admission severity was a better predictor of excess cost. Discussion: Four key complications occur more often in older patients with dementia and the high rate of these complications makes them expensive. These complications are potentially preventable. However, the care that can prevent them (such as mobility, hydration, nutrition and communication) is known to be rationed or left unfinished by nurses. Older hospitalised people who have complex needs, such as those with dementia, are more likely to experience care rationing as their care tends to take longer, be less predictable and less curative in nature. This thesis offers the theoretical proposition that evidence-based nursing practices are rationed for complex older patients and that this rationed care contributes to functional and cognitive decline during hospitalisation. This, in turn, contributes to the high rates of complications observed. Thus four key complications can be seen as a ‘Failure to Maintain’ complex older people in hospital. ‘Failure to Maintain’ is the inadequate delivery of essential functional and cognitive care for a complex older person in hospital resulting in a complication, and is recommended as a useful indicator for hospital quality. Conclusions: When examining extra length of stay in hospital, complications and comorbid dementia are costly. Complications are potentially preventable, and dementia care in hospitals can be improved. Hospitals and governments looking to decrease costs can engage in risk-reduction strategies for common nurse sensitive complications such as healthy nursing work environments that minimise nurses’ rationing of functional and cognitive care. The conceptualisation of complex older patients as ‘business as usual’ rather than a ‘burden’ is likely necessary for sustainable health care services of the future. The use of the ‘Failure to Maintain’ indicators at institution and state levels may aid in embedding this approach for complex older patients into health organisations. Ongoing investigation is warranted into the relationships between the largest health services expense (hospitals), the largest hospital population (complex older patients), and the largest hospital expense (nurses). The ‘Failure to Maintain’ quality indicator makes a useful and substantive contribution to further clinical, administrative and research developments.
Resumo:
This paper deals with the numerical assessment of the influence of parameters such as pre-compression level, aspect ratio, vertical and horizontal reinforcement ratios and boundary conditions on the lateral strength of masonry walls under in-plane loading. The numerical study is performed through the software DIANA (R) based on the Finite Element Method. The validation of the numerical model is carried out from a database of available experimental results on masonry walls tested under cyclic lateral loading. Numerical results revealed that boundary conditions play a central role on the lateral behavior of masonry walls under in-plane loading and determine the influence of level of pre-compression as well as the reinforcement ratio on the wall strength. The lateral capacity of walls decreases with the increase of aspect ratio and with the decrease of pre-compression. Vertical steel bars appear to have almost no influence in the shear strength of masonry walls and horizontal reinforcement only increases the lateral strength of masonry walls if the shear response of the walls is determinant for failure, which is directly related to the boundary conditions. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
A large percentage of pile caps support only one column, and the pile caps in turn are supported by only a few piles. These are typically short and deep members with overall span-depth ratios of less than 1.5. Codes of practice do not provide uniform treatment for the design of these types of pile caps. These members have traditionally been designed as beams spanning between piles with the depth selected to avoid shear failures and the amount of longitudinal reinforcement selected to provide sufficient flexural capacity as calculated by the engineering beam theory. More recently, the strut-and-tie method has been used for the design of pile caps (disturbed or D-region) in which the load path is envisaged to be a three-dimensional truss, with compressive forces being supported by concrete compressive struts between the column and piles and tensile forces being carried by reinforcing steel located between piles. Both of these models have not provided uniform factors of safety against failure or been able to predict whether failure will occur by flexure (ductile mode) or shear (fragile mode). In this paper, an analytical model based on the strut-and-tie approach is presented. The proposed model has been calibrated using an extensive experimental database of pile caps subjected to compression and evaluated analytically for more complex loading conditions. It has been proven to be applicable across a broad range of test data and can predict the failures modes, cracking, yielding, and failure loads of four-pile caps with reasonable accuracy.
Resumo:
This work presents a comparison between laser weld (LBW) and electric resistance spot weld (ERSW) processes used for assemblies of components in a body-in-white (BIW) at a world class automotive industry. It is carried out by evaluating the mechanical strength modeled both by experimental and numerical methods. An ""Arcan"" multiaxial test was designed and manufactured in order to enable 0 degrees, 45 degrees and 90 degrees directional loadings. The welded specimens were uncoated low carbon steel sheets (S-y = 170 MPa) used currently at the automotive industry, with two different thicknesses: 0.80 and 1.20 mm. A numerical analysis was carried out using the finite element method (FEM) through LS-DYNA code. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
The time varying intensity character of a load applied to a structure poses many difficulties in analysis. A remedy to this situation is to substitute a complex pulse shape by a rectangular equivalent one. It has been shown by others that this procedure works well for perfectly plastic elementary structures. This paper applies the concept of equivalent pulse to more complex structures. Special attention is given to the material behavior, which is allowed to be strain rate and strain hardening sensitive. Thanks to the explicit finite element solution, it is shown in this article that blast loads applied to complex structures made of real materials can be substituted by equivalent rectangular loads with both responses being practically the same. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
A copper(II) chiral aza-bis(oxazoline) homogeneous catalyst (CuazaBox) was anchored onto the external surface of MCM-22 and ITQ-2 structures, as well as encapsulated into hierarchical MCM-22. The transition metal complex loading onto the porous solids was determined by ICP-AES and the materials were also characterized by elemental analysis (C, N, H, S), FTIR, XPS, TG and low temperature N-2 adsorption isotherms. The materials were tested as heterogeneous catalysts in the benchmark reaction of cyclopropanation of styrene to check the effect of the immobilization procedure on the catalytic parameters, as well as on their reutilization in several catalytic cycles. Catalyst CuazaBox anchored onto the external surface of MCM-22 and ITQ-2 materials were more active and enantioselective in the cyclopropanation of styrene than the corresponding homogeneous phase reaction run under similar experimental conditions. This is due to the propylation of the acidic aza-Box nitrogen. HMCM-22 was nevertheless the best heterogeneous catalyst. Encapsulation of CuazaBox on post-synthesis modified MCM-22 materials led to low activities and enantioselectivities. But reversal on the stereochemical course of the reaction was observed, probably due to confinement effect. (C) 2013 Elsevier Inc. All rights reserved.
Resumo:
As ligações adesivas são frequentemente utilizadas na fabricação de estruturas complexas que não poderiam ou não seriam tão fáceis de ser fabricadas numa só peça, a fim de proporcionar uma união estrutural que, teoricamente, deve ser pelo menos tão resistente como o material de base. As juntas adesivas têm vindo a substituir métodos como a soldadura, e ligações parafusadas e rebitadas, devido à facilidade de fabricação, menor custo, facilidade em unir materiais diferentes, melhor resistência, entre outras características. Os materiais compósitos reforçados com fibra de carbono são amplamente utilizados em muitas indústrias, tais como de construção de barcos, automóvel e aeronáutica, sendo usados em estruturas que requerem elevada resistência e rigidez específicas, o que reduz o peso dos componentes, mantendo a resistência e rigidez necessárias para suportar as diversas cargas aplicadas. Embora estes métodos de fabricação reduzam ao máximo as ligações através de técnicas de fabrico avançadas, estas ainda são necessárias devido ao tamanho dos componentes, limitações de projecto tecnológicas e logísticas. Em muitas estruturas, a combinação de compósitos com metais tais como alumínio ou titânio traz vantagens de projecto. Este trabalho tem como objectivo estudar, experimentalmente e por modelos de dano coesivo (MDC), juntas adesivas em L entre componentes de alumínio e compósito de carbono epóxido quando solicitados a forças de arrancamento, considerando diferentes configurações de junta e adesivos de ductilidade distinta. Os parâmetros geométricos abordados são a espessura do aderente de alumínio (tP2) e comprimento de sobreposição (LO). A análise numérica permitiu o estudo da distribuição das tensões, evolução do dano, resistência e modos de rotura. Os testes experimentais validam os resultados numéricos e fornecem mecanismos de projecto para juntas em L. Foi mostrado que a geometria do aderente em L (alumínio) e o tipo de adesivo têm uma influência directa na resistência de junta.
Resumo:
Doctoral Thesis Civil Engineering
Resumo:
Rectangular hollow section (RHS) members are components widely used in engineering applications because of their good-looking, good properties in engineering areas and inexpensive cost comparing to members with other sections. The increasing use of RHS in load bearing structures makes it necessary to analyze the fatigue behavior of the RHS members. In this thesis, concentration will be given to the fatigue behavior of the RHS members under variable amplitude pure torsional loading. For the RHS members, failure will normally occur in the corner region if the welded regions are under full penetration. This is because of the complicated stress components' distributions at the RHScorners, where all of three fracture mechanics modes will happen. Mode I is mainly caused by the residual stresses that caused by the manufacturing process. Modes II and III are caused by the applied torsional loading. Stress based Findleymodel is also used to analyze the stress components. Constant amplitude fatigue tests have been done as well as variable amplitude fatigue tests. The specimens under variable amplitude loading gave longer fatigue lives than those under constant amplitude loading. Results from tests show an S-N curvewith slope around 5.