961 resultados para Diagnosi de circuits analògics
Resumo:
Computer aided design of Monolithic Microwave Integrated Circuits (MMICs) depends critically on active device models that are accurate, computationally efficient, and easily extracted from measurements or device simulators. Empirical models of active electron devices, which are based on actual device measurements, do not provide a detailed description of the electron device physics. However they are numerically efficient and quite accurate. These characteristics make them very suitable for MMIC design in the framework of commercially available CAD tools. In the empirical model formulation it is very important to separate linear memory effects (parasitic effects) from the nonlinear effects (intrinsic effects). Thus an empirical active device model is generally described by an extrinsic linear part which accounts for the parasitic passive structures connecting the nonlinear intrinsic electron device to the external world. An important task circuit designers deal with is evaluating the ultimate potential of a device for specific applications. In fact once the technology has been selected, the designer would choose the best device for the particular application and the best device for the different blocks composing the overall MMIC. Thus in order to accurately reproducing the behaviour of different-in-size devices, good scalability properties of the model are necessarily required. Another important aspect of empirical modelling of electron devices is the mathematical (or equivalent circuit) description of the nonlinearities inherently associated with the intrinsic device. Once the model has been defined, the proper measurements for the characterization of the device are performed in order to identify the model. Hence, the correct measurement of the device nonlinear characteristics (in the device characterization phase) and their reconstruction (in the identification or even simulation phase) are two of the more important aspects of empirical modelling. This thesis presents an original contribution to nonlinear electron device empirical modelling treating the issues of model scalability and reconstruction of the device nonlinear characteristics. The scalability of an empirical model strictly depends on the scalability of the linear extrinsic parasitic network, which should possibly maintain the link between technological process parameters and the corresponding device electrical response. Since lumped parasitic networks, together with simple linear scaling rules, cannot provide accurate scalable models, either complicate technology-dependent scaling rules or computationally inefficient distributed models are available in literature. This thesis shows how the above mentioned problems can be avoided through the use of commercially available electromagnetic (EM) simulators. They enable the actual device geometry and material stratification, as well as losses in the dielectrics and electrodes, to be taken into account for any given device structure and size, providing an accurate description of the parasitic effects which occur in the device passive structure. It is shown how the electron device behaviour can be described as an equivalent two-port intrinsic nonlinear block connected to a linear distributed four-port passive parasitic network, which is identified by means of the EM simulation of the device layout, allowing for better frequency extrapolation and scalability properties than conventional empirical models. Concerning the issue of the reconstruction of the nonlinear electron device characteristics, a data approximation algorithm has been developed for the exploitation in the framework of empirical table look-up nonlinear models. Such an approach is based on the strong analogy between timedomain signal reconstruction from a set of samples and the continuous approximation of device nonlinear characteristics on the basis of a finite grid of measurements. According to this criterion, nonlinear empirical device modelling can be carried out by using, in the sampled voltage domain, typical methods of the time-domain sampling theory.
Resumo:
Electromagnetic spectrum can be identified as a resource for the designer, as well as for the manufacturer, from two complementary points of view: first, because it is a good in great demand by many different kind of applications; second, because despite its scarce availability, it may be advantageous to use more spectrum than necessary. This is the case of Spread-Spectrum Systems, those systems in which the transmitted signal is spread over a wide frequency band, much wider, in fact, than the minimum bandwidth required to transmit the information being sent. Part I of this dissertation deals with Spread-Spectrum Clock Generators (SSCG) aiming at reducing Electro Magnetic Interference (EMI) of clock signals in integrated circuits (IC) design. In particular, the modulation of the clock and the consequent spreading of its spectrum are obtained through a random modulating signal outputted by a chaotic map, i.e. a discrete-time dynamical system showing chaotic behavior. The advantages offered by this kind of modulation are highlighted. Three different prototypes of chaos-based SSCG are presented in all their aspects: design, simulation, and post-fabrication measurements. The third one, operating at a frequency equal to 3GHz, aims at being applied to Serial ATA, standard de facto for fast data transmission to and from Hard Disk Drives. The most extreme example of spread-spectrum signalling is the emerging ultra-wideband (UWB) technology, which proposes the use of large sections of the radio spectrum at low amplitudes to transmit high-bandwidth digital data. In part II of the dissertation, two UWB applications are presented, both dealing with the advantages as well as with the challenges of a wide-band system, namely: a chaos-based sequence generation method for reducing Multiple Access Interference (MAI) in Direct Sequence UWB Wireless-Sensor-Networks (WSNs), and design and simulations of a Low-Noise Amplifier (LNA) for impulse radio UWB. This latter topic was studied during a study-abroad period in collaboration with Delft University of Technology, Delft, Netherlands.
Resumo:
Il lavoro svolto nella presente tesi di laurea si sviluppa all’interno del progetto di ricerca europeo SmooHs (Smart Monitoring of Historic Structures-Monitoraggio intelligente di edifici e strutture storiche) nell’ambito del 7 Programma Quadro della Commissione Europea. Gli edifici storici sono caratterizzati da elementi architettonici, materiali e soluzioni progettuali uniche e pertanto da valorizzare. Al fine si salvaguardare tali beni storici si richiede una conoscenza approfondita dei processi di deterioramento, legati spesso a fattori ambientali, e una loro rilevazione immediata. Il monitoraggio continuo dei possibili parametri che influenzano i suddetti processi può contribuire significativamente, ma un’applicazione estesa di questa tecnica è finora fallita a causa dei costi elevati di sistemi completi di monitoraggio; per questo sono stati osservati solitamente pochi parametri. L’obiettivo del progetto prevede lo sviluppo di strumenti di monitoraggio e diagnostica competitivi per gli specialisti nel settore che vada al di là del mero accumulo di dati. La normativa, in particolare le Linee Guida per l’applicazione al patrimonio culturale della normativa tecnica di cui all’Ordinanza PCM-3274 del 2005, evidenziano l’importanza di raggiungere un elevato livello di informazione dell’oggetto e del suo comportamento strutturale attraverso un percorso conoscitivo pluriramificato. “Si ha pertanto la necessità di affinare tecniche di analisi ed interpretazione dei manufatti storici mediante fasi conoscitive dal diverso grado di attendibilità, anche in relazione al loro impatto. La conoscenza può infatti essere conseguita con diversi livelli di approfondimento, in funzione dell’accuratezza delle operazioni di rilievo, delle ricerche storiche e delle indagini sperimentali” (Linee guida per l’applicazione all patrimonio culturale della normativa tecnica di cui all’ordinanza PCM-3274, 2005). Per quanto riguarda la caratterizzazione meccanica dei materiali, la normativa cita “Tecniche diagnostiche non distruttive di tipo indiretto, quali prove soniche ed ultrasoniche, consentono di valutare l’omogeneità dei parametri meccanici nelle diverse parti della costruzione, ma non forniscono stime quantitative attendibili dei loro valori, in quanto essi vengono desunti dalla misura di altre grandezze”. Non viene identificata una procedura univoca di prove non distruttive per ciascuna tipologia edilizia, pertanto ci domandiamo quale sia la procedura più idonea da utilizzare, considerando il tipo di risultato che si vuole ottenere. Si richiedono quindi degli studi di fattibilità di diverse tecniche non distruttive, soprattutto tecniche per immagini che diano un risultato più immediato da comprendere. Per questo scopo è stato impostato un programma di ricerca per valutare l’efficacia di una tecnica non distruttiva, la tomografia sonica, su provini in muratura costruiti nei laboratori del LaRM (Laboratorio di Resistenza dei Materiali del DISTART dell’Università di Bologna), reputando questa la strada da percorrere verso una diagnostica strutturale sempre più dettagliata. I provini in muratura di laterizio PNDE e PNDF, presentano al loro interno dei difetti (in polistirolo espanso) di geometria e posizione nota e diverse tessiture murarie (muratura di laterizio tradizionale e muratura a sacco). Nel capitolo 2 vengono descritte le caratteristiche e le basi teoriche delle prove soniche e di altre tecniche non distruttive, al fine di poterne fare un confronto. La tomografia sonica è definita e sono illustrate le sue peculiarità; vengono inoltre riportati alcuni esempi di applicazioni della stessa su strutture storiche lignee e murarie. Nel capitolo 3 sono presentati i provini oggetto di studio ed introdotto qualche accenno sulla natura delle murature di laterizio. Sono specificati i corsi e le sezioni verticali sui quali viene sperimentata la tomografia; essi hanno precise caratteristiche che permettono di eseguire una sperimentazione mirata all’individuazione di anomalie in una sezione e al riconoscimento di diverse tessiture murarie. Nel capitolo 4 è illustrata la procedura di acquisizione dei dati in laboratorio e di rielaborazione degli stessi nella fase di post-processing. Dopo aver scelto, in base alla risoluzione, la distanza che intercorre tra le stazioni di misura, sono stati progettati i vari percorsi uscenti da ogni stazione trasmittente, andando a definire i ray-paths delle sezioni sia orizzontali che verticali. I software per il calcolo dei tempi di volo (in ambiente LabView) e per l’inversione degli stessi (Geotom) sono presentati e vengono definite le istruzioni per l’utilizzo. Il capitolo 5 assieme al capitolo 6, mostra i risultati ottenuti dall’inversione dei tempi di volo. Per i diversi corsi orizzontali e sezioni verticali sono riportate le mappe di velocità ottenute al variare di diversi parametri di settaggio impostati nel software tomografico. Le immagini tomografiche evidenziano le caratteristiche interne delle sezioni studiate, in base alla risoluzione geometrica della tecnica. Nel capitolo 7 e 8 sono mostrati i risultati delle prove soniche dirette applicate sia sui corsi verticali sia sulle sezioni verticali. Le stazioni di misura considerate sono le stesse utilizzate per la tomografia. Il capitolo 9 riporta il confronto tra le mappe di velocità prodotte dalla tomografia sonica e gli istogrammi delle velocità registrate nelle prove soniche dirette. Si evidenziano le differenze nell’individuazione di difetti tra due metodologie differenti. Infine sono riportate le conclusioni sul lavoro svolto. I limiti e i vantaggi della tecnica tomografica vengono desunti dai risultati ottenuti per varie tipologie di sezioni, a confronto anche con risultati di prove soniche dirette. Ciò ci porta a definire la fattibilità di utilizzo della tomografia sonica nella diagnosi delle strutture in muratura.
Resumo:
The running innovation processes of the microwave transistor technologies, used in the implementation of microwave circuits, have to be supported by the study and development of proper design methodologies which, depending on the applications, will fully exploit the technology potentialities. After the choice of the technology to be used in the particular application, the circuit designer has few degrees of freedom when carrying out his design; in the most cases, due to the technological constrains, all the foundries develop and provide customized processes optimized for a specific performance such as power, low-noise, linearity, broadband etc. For these reasons circuit design is always a “compromise”, an investigation for the best solution to reach a trade off between the desired performances. This approach becomes crucial in the design of microwave systems to be used in satellite applications; the tight space constraints impose to reach the best performances under proper electrical and thermal de-rated conditions, respect to the maximum ratings provided by the used technology, in order to ensure adequate levels of reliability. In particular this work is about one of the most critical components in the front-end of a satellite antenna, the High Power Amplifier (HPA). The HPA is the main power dissipation source and so the element which mostly engrave on space, weight and cost of telecommunication apparatus; it is clear from the above reasons that design strategies addressing optimization of power density, efficiency and reliability are of major concern. Many transactions and publications demonstrate different methods for the design of power amplifiers, highlighting the availability to obtain very good levels of output power, efficiency and gain. Starting from existing knowledge, the target of the research activities summarized in this dissertation was to develop a design methodology capable optimize power amplifier performances complying all the constraints imposed by the space applications, tacking into account the thermal behaviour in the same manner of the power and the efficiency. After a reminder of the existing theories about the power amplifier design, in the first section of this work, the effectiveness of the methodology based on the accurate control of the dynamic Load Line and her shaping will be described, explaining all steps in the design of two different kinds of high power amplifiers. Considering the trade-off between the main performances and reliability issues as the target of the design activity, we will demonstrate that the expected results could be obtained working on the characteristics of the Load Line at the intrinsic terminals of the selected active device. The methodology proposed in this first part is based on the assumption that designer has the availability of an accurate electrical model of the device; the variety of publications about this argument demonstrates that it is so difficult to carry out a CAD model capable to taking into account all the non-ideal phenomena which occur when the amplifier operates at such high frequency and power levels. For that, especially for the emerging technology of Gallium Nitride (GaN), in the second section a new approach for power amplifier design will be described, basing on the experimental characterization of the intrinsic Load Line by means of a low frequency high power measurements bench. Thanks to the possibility to develop my Ph.D. in an academic spin-off, MEC – Microwave Electronics for Communications, the results of this activity has been applied to important research programs requested by space agencies, with the aim support the technological transfer from universities to industrial world and to promote a science-based entrepreneurship. For these reasons the proposed design methodology will be explained basing on many experimental results.
Resumo:
Increasingly stringent exhaust emission limits and higher fuel economy are the main drivers of the engine development process. As a consequence, the complexity of the propulsion units and its subsystems increase, due to the extensive use of sensors and actuators needed to obtain a precise control over the combustion phase. Since engine calibration process consumes most of the development time, new tools and methodologies are needed to shorten the development time and increase the performance attainable. Real time combustion analysis, based on the in-cylinder pressure signal, can significantly improve the calibration of the engine control strategies and the development of new algorithms, giving instantaneous feedback on the engine behavior. A complete combustion analysis and diagnosis system has been developed, capable of evaluating the most important indicators about the combustion process, such as indicated mean effective pressure, heat release, mass fraction burned and knock indexes. Such a tool is built on top of a flexible, modular and affordable hardware platform, capable of satisfying the requirements needed for accuracy and precision, but also enabling the use directly on-board the vehicle, due to its small form factor.
Resumo:
Le prove non distruttive che sono state studiate in questa tesi sono il monitoraggio termografico, le prove soniche, la tecnica tomografica sonica e l’indagine tramite georadar. Ogni capitolo di applicazione in sito o in laboratorio è sempre preceduto da un capitolo nel quale sono spiegati i principi fondamentali della tecnica applicata. I primi cinque capitoli riguardano un problema molto diffuso nelle murature, cioè la risalita capillare di umidità o di soluzione salina all’interno delle stesse. Spiegati i principi alla base della risalita capillare in un mezzo poroso e della tecnica termografica, sono state illustrate le tre prove svolte in laboratorio: una prova di risalita (di umidità e di salamoia) su laterizi, una prova di risalita di salamoia su tripletta muraria monitorata da sensori e una prova di risalita di umidità su muretto fessurato monitorata tramite termografia ad infrarossi. Nei capitoli 6 e 7 sono stati illustrati i principi fondamentali delle prove soniche ed è stata presentata un’analisi approfondita di diverse aree del Duomo di Modena in particolare due pareti esterne, un pilastro di muratura e una colonna di pietra. Nelle stesse posizioni sono state effettuate anche prove tramite georadar (Capitoli 11 e 12) per trovare analogie con le prove soniche o aggiungere informazioni che non erano state colte dalle prove soniche. Nei capitoli 9 e 10 sono stati spiegati i principi della tomografia sonica (tecnica di inversione dei tempi di volo e tecnica di inversione delle ampiezze dei segnali), sono stati illustrati i procedimenti di elaborazione delle mappe di velocità e sono state riportate e commentate le mappe ottenute relativamente ad un pilastro di muratura del Duomo di Modena (sezioni a due quote diverse) e ad un pilastro interno di muratura della torre Ghirlandina di Modena.
Resumo:
“Naturally occurring cancers in pet dogs and humans share many features, including histological appearance, tumour genetics, molecular targets, biological behaviour and response to conventional therapies. Studying dogs with cancer is likely to provide a valuable perspective that is distinct from that generated by the study of human or rodent cancers alone. The value of this opportunity has been increasingly recognized in the field of cancer research for the identification of cancer-associated genes, the study of environmental risk factors, understanding tumour biology and progression, and, perhaps most importantly, the evaluation and development of novel cancer therapeutics”.(Paoloni and Khanna, 2008) In last years, the author has investigated some molecular features of cancer in dogs. The Thesis is articulated in two main sections. In section 1, the preliminary results of a research project aimed at investigating the role of somatic mutations of Ataxia-Telangiectasia mutated (ATM) gene in predisposing to cancer in boxer dogs, are presented. The canine boxer breed may be considered an unique opportunity to disclose the role of ATM somatic mutation since boxer dogs are known to be dramatically susceptible to cancer and since they may be considered a closed gene pool. Furthermore, dogs share with human the some environment. Overall, the abovementioned features could be considered extremely useful for our purposes. In the section 2, the results of our studies aimed at setting up accurate and sensitive molecular assays for diagnosing and assessing minimal residual disease in lymphoproliferative disorders of dogs, are presented. The results of those molecular assay may be directly translated in the field of Veterinary practice as well as the may be used to improve our objective evaluation of new investigational drugs effectiveness in canine cancer trials.
Resumo:
OBJECTIVE: One major problem in counselling couples with a prenatal diagnosis of a correctable fetal anomaly is the ability to exclude associated malformations that may modify the prognosis. Our aim was to assess the precision of fetal sonography in identifying isolated malformations. METHODS: We retrospectively reviewed the prenatal and postnatal records of our center for cases with a prenatal diagnosis of an isolated fetal anomaly in the period 2002-2007. RESULTS: The antenatal diagnosis of an isolated malformation was made in 284 cases. In one of this cases the anomaly disappeared in utero. Of the remaining cases, the prenatal diagnosis was confirmed after birth in 251 (88.7%). In 8 fetuses (7 with a suspected coarctation of the aorta, 1 with ventricular septal defect) the prenatal diagnosis was not confirmed. In 24 fetuses (8.5%) additional malformations were detected at postnatal or post-mortem. In 16 of these cases the anomalies were mild or would not have changed the prognosis. In 8 cases (2.8%) severe anomalies were present (1 hypoplasia of the corpus callosum with ventriculomegaly, 1 tracheal agenesis, 3 cases with multiple anomalies, 1 Opitz Syndrome, 1 with CHARGE Syndrome, 1 COFS Syndrome). Two of these infants died. CONCLUSIONS: the prenatal diagnosis of an isolated fetal anomaly is highly reliable. However, the probability that additional malformations will go undetected albeit small remains tangible. In our experience, it was 2.8%.
Resumo:
L’ecografia è la metodica diagnostica più utilizzata come screening e follow-up nei pazienti epatopatici con o senza lesioni focali e questo grazie alle sue peculiari caratteristiche, che sono date dall’essere real-time, maneggevole, priva di radiazioni ionizzanti e con bassi costi. Tuttavia tale metodica se confrontata con la TC o la RMN, può avere importanti limiti, quali l’impossibilità di visualizzare piccole lesioni localizzate in aree anatomicamente “difficili” o in pazienti obesi, che sono già state identificate con altre tecniche, come la TC o la RMN. Per superare queste limitazioni sono stati introdotti dei sistemi di “fusione d’immagine” che consentono di sincronizzare in tempo reale una metodica real time con bassa risoluzione spaziale come l’ecografia ed una statica ad alta risoluzione come la TC o la RMN. Ciò si ottiene creando attorno al paziente un piccolo campo elettromagnetico costituito da un generatore e da un rilevatore applicato al trasduttore ecografico ed introducendo in un computer abbinato all’ecografo il “volume rendering” dell’addome del paziente ottenuto mediante TC multistrato o RM. Il preciso “ appaiamento spaziale “ delle due metodiche si ottiene individuando in entrambe lo stesso piano assiale di riferimento e almeno 3-4 punti anatomici interni. Tale sistema di fusione d’immagine potrebbe essere molto utile in campo epatologico nella diagnostica non invasiva del piccolo epatocarcinoma, che secondo le ultime linee guida, nei noduli di dimensioni fra 1 e 2 cm, richiede una concordanza nel comportamento contrastografico della lesione in almeno due tecniche d’immagine. Lo scopo del nostro lavoro è stato pertanto quello di valutare, in pazienti epatopatici, il contributo che tale sistema può dare nell’identificazione e caratterizzazione di lesioni inferiori a 20 mm, che erano già state identificate alla TC o alla RMN come noduli sospetti per HCC, ma che non erano stati visualizzati in ecografia convenzionale. L’eventuale re-identificazione con l’ecografia convenzionale dei noduli sospetti per essere HCC, può permettere di evitare, alla luce dei criteri diagnostici non invasivi un’ ulteriore tecnica d’immagine ed eventualmente la biopsia. Pazienti e Metodi: 17 pazienti cirrotici (12 Maschi; 5 Femmine), con età media di 68.9 +/- 6.2 (SD) anni, in cui la TC e la RMN con mezzo di contrasto avevano identificato 20 nuove lesioni focali epatiche, inferiori a 20 mm (13,6 +/- 3,6 mm), sospette per essere epatocarcinomi (HCC), ma non identificate all’ecografia basale (eseguita in cieco rispetto alla TC o alla RMN) sono stati sottoposti ad ecografia senza e con mezzo di contrasto, focalizzata su una zona bersaglio identificata tramite il sistema di fusione d’immagini, che visualizza simultaneamente le immagini della TC e della RMN ricostruite in modalità bidimensionale ( 2D), tridimensionale ( 3 D) e real-time. La diagnosi finale era stata stabilita attraverso la presenza di una concordanza diagnostica, secondo le linee guida internazionali o attraverso un follow-up nei casi di discordanza. Risultati: Una diagnosi non invasiva di HCC è stata raggiunta in 15/20 lesioni, inizialmente sospettate di essere HCC. Il sistema di fusione ha identificato e mostrato un comportamento contrastografico tipico in 12/15 noduli di HCC ( 80%) mentre 3/15 HCC (20%) non sono stati identificati con il sistema di fusione d’immagine. Le rimanenti 5/20 lesioni non sono state visualizzate attraverso i sistemi di fusione d’immagine ed infine giudicate come falsi positivi della TC e della RMN, poiché sono scomparse nei successivi mesi di follow-up e rispettivamente dopo tre, sei, nove, dodici e quindici mesi. Conclusioni: I nostri risultati preliminari mostrano che la combinazione del sistema di fusione dell’immagine associata all’ecografia senza e con mezzo di contrasto (CEUS), migliora il potenziale dell’ecografia nell’identificazione e caratterizzazione dell’HCC su fegato cirrotico, permettendo il raggiungimento di una diagnosi, secondo criteri non invasivi e slatentizzazndo casi di falsi positivi della TC e della RMN.
Resumo:
Introduzione La diagnosi di HCC con le tecniche di immagine ed in particolare con CEUS su fegato cirrotico secondo le ultime linee guida prevede un comportamento contrastografico di ipervascolarizzazione nella fase arteriosa e wash-out nella fase tardiva. CEUS è ormai una metodica accettata per la diagnosi ma il wash out nella fase tardiva presenta notevoli difficoltà nel determinare il comportamento contrastografico in quanto valutato soggettivamente su display, infatti il giudizio di tale fase dipende molto dall’operatore e non è rarissimo che nascono discordanza tra operatori anche per piccole differenze. Recentemente è stato proposto un nuovo software(SonoLiver, Bracco, Italy) in grado di quantificare la perfusione delle lesione durante CEUS. Pertanto lo scopo di questo studio pilota è quello di valutare l’impatto di SonoLiver nel rilevare caratteristiche contrastografiche tipiche dell’HCC e valutare la riproducibilità tra due operatori. Pazienti e metodi: Sono stati presi in considerazione 20 noduli (di dimensioni tra 12-95 mm) con diagnosi di HCC in 20 pazienti con cirrosi . La CEUS è stata valutata dapprima ad occhio nudo su display e successivamente con le curve ottenute con DVP da parte di due operatori diversi in cieco, dopo un periodo di formazione adeguata. Sono state quindi analizzate le performance di ciascuna metodica sia in termini di variabilità tra i due operatori che la variabilità tra CEUS ad occhio nudo e CEUS con SonoLiver dello stesso operatore. Risultati:Operatore 1 ha rilevato ipervascolarizzazione in fase arteriosa in 17 su 20 pazienti con valutazione ad occhio nudo su schermo e su 19/20 con le curve ottenute con DVP (+10% sensibilità) mentre operatore 2 ha rilevato ipervascolarizzazione in fase arteriosa19/20 pazienti sia con valutazione ad occhio nudo che con le curve DVP. Nella fase tardiva il wash-out è stato rilevato in 7/20 ad occhio nudo e 10/20 pazienti con le curve DVP (sensibilità aumenta da 35% a 50%) mentre operatore 2 ha rilevato rispettivamente 8/20 e 11/20 (sensibilità aumenta da 40% a 55%). La riproducibilità tra i due operatori rimane invariata con la valutazione di Sonoliver sia nella fase arteriosa che nella fase tardiva. Conclusione:La quantificazione perfusionale con SonoLiver sembra essere uno strumento promettente nella diagnosi di HCC su fegato cirrotico, aumentando aspetti tipici contrastografici.