975 resultados para Descolamento da Retina


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show that with a fiberized multiple Michelson-interferometer-type configuration, transverse images from several layers in the human eye can be simultaneously obtained. We demonstrate the principle by producing simultaneous 100×100 pixel en-face images of a 4 mm×4 mm region on a postmortem retina for two depth positions 250 µm apart.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We examined the intrinsic signals in response to grating stimuli in order to determine whether the light-evoked intrinsic signals of the retina are due to changes in the photoreceptor activities induced by the image projected on to the retina or are due to neural activities of the inner retina. The retinas of the left eye of 12 cats under general anesthesia were examined by a functional imaging fundus camera. Near infrared light was used to monitor the reflectance changes (RCs) of the retina. Vertical grating were used to stimulate the retina at 4 Hz. The spatial frequencies of the gratings were 0.05, 0.11, 0.22, 0.43, 0.86, 1.73, and 3.46 cycles/degree (cpd). Ten images were averaged and used to analyze the RCs to obtain the peak value (PV) of a two dimensional fast Fourier transfer of the RCs. The wavefront aberrations (WA) were measured with a compact wavefront aberrometer and the spatial modulation transfer function (MTF) of the eye was calculated. The retinal reflectance image had a grating pattern. The PV of the spatial sensitivity curve was highest at low spatial frequencies (0.05 and 0.11 cpd), and the sensitivity decreased steeply with an increase in the spatial frequency. RCs were not detectable at 3.46 cpd. The MTF decreased gradually with increases in the spatial frequencies and was 0.68 at 3.46 cpd. The reflectance pattern of the retinal intrinsic signal elicited by grating stimuli of different spatial frequencies was different from that of the MTF. This suggests that the intrinsic signal represents not only the response of the photoreceptors but also other neuronal or vascular changes in the retina.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The quarter century since the foundation of the Royal College of Ophthalmologists has coincided with immense change in the subspecialty of medical retina, which has moved from being the province of a few dedicated enthusiasts to being an integral, core part of ophthalmology in every eye department. In age-related macular degeneration, there has been a move away from targeted, destructive laser therapy, dependent on fluorescein angiography to intravitreal injection therapy of anti-growth factor agents, largely guided by optical coherence tomography. As a result of these changes, ophthalmologists have witnessed a marked improvement in visual outcomes for their patients with wet age-related macular degeneration (AMD), while at the same time developing and enacting entirely novel ways of delivering care. In the field of diabetic retinopathy, this period also saw advances in laser technology and a move away from highly destructive laser photocoagulation treatment to gentler retinal laser treatments. The introduction of intravitreal therapies, both steroids and anti-growth factor agents, has further advanced the treatment of diabetic macular oedema. This era has also seen in the United Kingdom the introduction of a coordinated national diabetic retinopathy screening programme, which offers an increasing hope that the burden of blindness from diabetic eye disease can be lessened. Exciting future advances in retinal imaging, genetics, and pharmacology will allow us to further improve outcomes for our patients and for ophthalmologists specialising in medical retina, the future looks very exciting but increasingly busy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show that with a fiberized multiple Michelson-interferometer-type configuration, transverse images from several layers in the human eye can be simultaneously obtained. We demonstrate the principle by producing simultaneous 100×100 pixel en-face images of a 4 mm×4 mm region on a postmortem retina for two depth positions 250 µm apart.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An optical coherence tomography (OCT) system to produce both longitudinal and transversal images of the in vivo human eye is presented. For the first time, OCT transversal images collected from the living eye at 50-µm depth steps show details unobtainable with the state-of-the-art scanning laser ophthalmoscope. Images of up to 3×3?mm are produced from the retina in less than a second. For images larger than 1.6×1.6?mm, a path modulation is introduced by the galvanometric scanning mirror and is used as an effective phase modulation method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Age-related macular degeneration (AMD) is the leading cause of blindness inAmerica. The fact that AMD wreaks most of the damage in the center of the retina raises the question of whether light, integrated over long periods, is more concentrated in the macula. A method, based on eye-tracking, was developed to measure the distribution of light in the retina under natural viewing conditions. The hypothesis was that integrated over time, retinal illumination peaked in the macula. Additionally a possible relationship between age and retinal illumination was investigated. The eye tracker superimposed the subject's gaze position on a video recorded by a scene camera. Five informed subjects were employed in feasibility tests, and 58 naïve subjects participated in 5 phases. In phase 1 the subjects viewed a gray-scale image. In phase 2, they observed a sequence of photographic images. In phase 3 they viewed a video. In phase 4, they worked on a computer; in phase 5, the subjects walked around freely. The informed subjects were instructed to gaze at bright objects in the field of view and then at dark objects. Naïve subjects were allowed to gaze freely for all phases. Using the subject's gaze coordinates, and the video provided by the scene camera, the cumulative light distribution on the retina was calculated for ∼15° around the fovea. As expected for control subjects, cumulative retinal light distributions peaked and dipped in the fovea when they gazed at bright or dark objects respectively. The light distribution maps obtained from the naïve subjects presented a tendency to peak in the macula for phases 1, 2, and 3, a consistent tendency in phase 4 and a variable tendency in phase 5. The feasibility of using an eye-tracker system to measure the distribution of light in the retina was demonstrated, thus helping to understand the role played by light exposure in the etiology of AMD. Results showed that a tendency for light to peak in the macula is a characteristic of some individuals and of certain tasks. In these situations, risk of AMD could be increased. No significant difference was observed based on age.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selenium is known to occur in the enzyme, glutathione peroxidase, and plays an important role as an antioxidant. The objective of this investigation was to determine if amounts of selenium are selectively accumulated in different regions of the retina or uniformly distributed with eccentricity. 20 human retinas were analyzed for selenium. 18 of these were sectioned into a disc and two concentric annuli centered on the fovea using trephines having diameters of 3, 11, and 21 mm. The sections had areas of7.1, 93, and 343 mm2, respectively. Corresponding sections of these retinas were combined and analyzed together in sets of n = 5 and n = 11. For two donors, the whole retina of one eye was analyzed for selenium and the other retina was sectioned for analysis as described above. Selenium was determined using atomic fluorescence spectroscopy after digestion of the retinal tissues in nitric acid. The two whole retinas were found to have an average of 0.89 ± 0.49 pmoles/mm2 of selenium as compared to the companion which had 0.84 ± 0.28 pmoles/mm2 as determined from the sum of the selenium amounts measured in the individual sections. The inner, medial, and outer portions of these two sectioned retinas were found to contain an average of5.28 ± 1.1, 1.28 ± 0.44, 0.63 ± 0.22 pmoles/mm2, respectively. The five retinas that were sectioned and pooled for analysis were found to have average amounts of3.64, 1.26, and 0.56 pmoles/mm2 • The 11-sectioned retinas were found to have 1.16, 0.61, and 0.38 pmoles/mm2 respectively in the same three sections. This limited data set indicates that selenium is not uniformly distributed within the human retina but rather concentrated to a greater extent within the macula. If confirmed, these data would support the hypothesis that selenium may be an important antioxidant involved in protection of the macula from radical oxidants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El glaucoma es una de las causas más comunes de discapacidad visual y una de las enfermedades neurodegenerativas oculares más frecuentes de pérdida irreversible de visión. La afectación originada en la retina se caracteriza por la degeneración de las células ganglionares y la pérdida de axones. La presión intraocular es un factor de riesgo importante en el glaucoma, entre otros factores, implicando mecanismos bioquímicos que desencadenan la muerte de las células ganglionares. El ratón DBA/2J es un modelo de hipertensión ocular y de degeneración de las células ganglionares de la retina (CGR). Las características principales de éste son la dispersión del pigmento del iris (IPD) y la atrofia del estroma del iris (ISA) que conducen a la patogénesis del glaucoma. Los mecanismos bioquímicos que comprometen al sistema purinérgico en procesos patológicos como la degeneración glaucomatosa han sido estudiados en los últimos años, siendo de gran relevancia como posibles dianas farmacológicas para el tratamiento de diferentes neuropatías. Los receptores P2X comprenden una familia de siete canales iónicos de membrana activados por ligando (P2X1-7) que se activan por el ATP extracelular (ATPe). En particular, los receptores P2X7 podrían estar involucrados en la regulación de la transmisión sináptica y la muerte neuronal en la retina. Además, la excitotoxicidad mediada por ATP a través de la activación del receptor P2X7 sugiere su posible implicación en la degeneración neuronal y la pérdida de la función visual en las retinas glaucomatosas. Tan importante como la presencia de este receptor purinérgico es estudiar los niveles de ATP extracelular de la retina, así como evaluar los cambios en la expresión del transportador de nucleótidos vesicular (VNUT) y los niveles de ecto-nucleotidasa (E-NPP1) en este modelo murino de glaucoma durante el desarrollo de la enfermedad...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of my Ph.D. thesis is to enhance the visualization of the peripheral retina using wide-field optical coherence tomography (OCT) in a clinical setting.

OCT has gain widespread adoption in clinical ophthalmology due to its ability to visualize the diseases of the macula and central retina in three-dimensions, however, clinical OCT has a limited field-of-view of 300. There has been increasing interest to obtain high-resolution images outside of this narrow field-of-view, because three-dimensional imaging of the peripheral retina may prove to be important in the early detection of neurodegenerative diseases, such as Alzheimer's and dementia, and the monitoring of known ocular diseases, such as diabetic retinopathy, retinal vein occlusions, and choroid masses.

Before attempting to build a wide-field OCT system, we need to better understand the peripheral optics of the human eye. Shack-Hartmann wavefront sensors are commonly used tools for measuring the optical imperfections of the eye, but their acquisition speed is limited by their underlying camera hardware. The first aim of my thesis research is to create a fast method of ocular wavefront sensing such that we can measure the wavefront aberrations at numerous points across a wide visual field. In order to address aim one, we will develop a sparse Zernike reconstruction technique (SPARZER) that will enable Shack-Hartmann wavefront sensors to use as little as 1/10th of the data that would normally be required for an accurate wavefront reading. If less data needs to be acquired, then we can increase the speed at which wavefronts can be recorded.

For my second aim, we will create a sophisticated optical model that reproduces the measured aberrations of the human eye. If we know how the average eye's optics distort light, then we can engineer ophthalmic imaging systems that preemptively cancel inherent ocular aberrations. This invention will help the retinal imaging community to design systems that are capable of acquiring high resolution images across a wide visual field. The proposed model eye is also of interest to the field of vision science as it aids in the study of how anatomy affects visual performance in the peripheral retina.

Using the optical model from aim two, we will design and reduce to practice a clinical OCT system that is capable of imaging a large (800) field-of-view with enhanced visualization of the peripheral retina. A key aspect of this third and final aim is to make the imaging system compatible with standard clinical practices. To this end, we will incorporate sensorless adaptive optics in order to correct the inter- and intra- patient variability in ophthalmic aberrations. Sensorless adaptive optics will improve both the brightness (signal) and clarity (resolution) of features in the peripheral retina without affecting the size of the imaging system.

The proposed work should not only be a noteworthy contribution to the ophthalmic and engineering communities, but it should strengthen our existing collaborations with the Duke Eye Center by advancing their capability to diagnose pathologies of the peripheral retinal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: We studied whether the accumulation of advanced lipoxidation end-products (ALEs) in the diabetic retina is linked to the impairment of lipid aldehyde detoxification mechanisms.

Methods: Retinas were collected from nondiabetic and diabetic rats and processed for conventional and quantitative RT-PCR (qRT-PCR), Western blotting, immunohistochemistry, and aldehyde dehydrogenase (ALDH) activity assays. The effect of the ALDH1a1 inhibitor, NCT-501, on ALE accumulation and cell viability in cultured Müller glia also was investigated.

Results: The rat retina expressed a range of lipid aldehyde detoxifying ALDH and aldo-keto reductase (AKR) genes. In diabetes, mRNA levels were reduced for 5 of 9 transcripts tested. These findings contrasted with those in the lens and cornea where many of these enzymes were upregulated. We have reported previously accumulation of the acrolein (ACR)-derived ALE, FDP-lysine, in retinal Müller glia during diabetes. In the present study, we show that the main ACR-detoxifying ALDH and AKR genes expressed in the retina, namely, ALDH1a1, ALDH2, and AKR1b1, are principally localized to Müller glia. Diabetes-induced FDP-lysine accumulation in Müller glia was associated with a reduction in ALDH1a1 mRNA and protein expression in whole retina and a decrease in ALDH1a1-immunoreactivity specifically within these cells. No such changes were detected for ALDH2 or AKR1b1. Activity of ALDH was suppressed in the diabetic retina and blockade of ALDH1a1 in cultured Müller glia triggered FDP-lysine accumulation and reduced cell viability.

Conclusions: These findings suggest that downregulation of ALDH and AKR enzymes, particularly ALDH1a1, may contribute ALE accumulation in the diabetic retina.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-08

Relevância:

20.00% 20.00%

Publicador: