908 resultados para Damage identification in structures
Resumo:
Limitations associated with the visual information provided to surgeons during laparoscopic surgery increases the difficulty of procedures and thus, reduces clinical indications and increases training time. This work presents a novel augmented reality visualization approach that aims to improve visual data supplied for the targeting of non visible anatomical structures in laparoscopic visceral surgery. The approach aims to facilitate the localisation of hidden structures with minimal damage to surrounding structures and with minimal training requirements. The proposed augmented reality visualization approach incorporates endoscopic images overlaid with virtual 3D models of underlying critical structures in addition to targeting and depth information pertaining to targeted structures. Image overlay was achieved through the implementation of camera calibration techniques and integration of the optically tracked endoscope into an existing image guidance system for liver surgery. The approach was validated in accuracy, clinical integration and targeting experiments. Accuracy of the overlay was found to have a mean value of 3.5 mm ± 1.9 mm and 92.7% of targets within a liver phantom were successfully located laparoscopically by non trained subjects using the approach.
Resumo:
Cardiac troponin I (cTnI) and T (cTnT) have a high sequence homology across phyla and are sensitive and specific markers of myocardial damage. The purpose of this study was to evaluate the Cardiac Reader, a human point-of-care system for the determination of cTnT and myoglobin, and the Abbott Axsym System for the determination of cTnI and creatine kinase isoenzyme MB (CK-MB) in healthy dogs and in dogs at risk for acute myocardial damage because of gastric dilatation-volvulus (GDV) and blunt chest trauma (BCT). In healthy dogs (n = 56), cTnI was below detection limits (<0.1 microg/L) in 35 of 56 dogs (reference range 0-0.7 microg/L), and cTnT was not measurable (<0.05 ng/mL) in all but 1 dog. At presentation, cTnI, CK-MB, myoglobin, and lactic acid were all significantly higher in dogs with GDV (n = 28) and BCT (n = 8) than in control dogs (P < .001), but cTnT was significantly higher only in dogs with BCT (P = .033). Increased cTnI or cTnT values were found in 26 of 28 (highest values 1.1-369 microg/L) and 16 of 28 dogs (0.1-1.7 ng/mL) with GDV, and in 6 of 8 (2.3-82.4 microg/L) and 3 of 8 dogs (0.1-0.29 ng/mL) with BCT, respectively. In dogs suffering from GDV, cTnI and cTnT increased further within the first 48 hours (P < .001). Increased cardiac troponins suggestive of myocardial damage occurred in 93% of dogs with GDV and 75% with BCT. cTnI appeared more sensitive, but cTnT may be a negative prognostic indicator in GDV. Both systems tested seemed applicable for the measurement of canine cardiac troponins, with the Cardiac Reader particularly suitable for use in emergency settings.
Resumo:
Radiological identification is important in forensic medicine. Identification using comparison of individualising structures with ante- and post-mortem conventional radiographs has been known for a long time. New radiological procedures such as computed tomography (CT) and magnetic resonance imaging (MRI) are being increasingly used for identification. In this paper, a new comparative approach using various radiological methods is described and its application demonstrated. This new approach is the comparison of ante-mortem conventional radiographs with projected images calculated from post-mortem CT data. The identification procedure will be illustrated with reference to the frontal sinus and the pelvis.
Resumo:
Bacterial meningitis due to Streptococcus pneumoniae is associated with an significant mortality rate and persisting neurologic sequelae including sensory-motor deficits, seizures, and impairments of learning and memory. The histomorphological correlate of these sequelae is a pattern of brain damage characterized by necrotic tissue damage in the cerebral cortex and apoptosis of neurons in the hippocampal dentate gyrus. Different animal models of pneumococcal meningitis have been developed to study the pathogenesis of the disease. To date, the infant rat model is unique in mimicking both forms of brain damage documented in the human disease. In the present study, we established an infant mouse model of pneumococcal meningitis. Eleven-days-old C57BL/6 (n = 299), CD1 (n = 42) and BALB/c (n = 14) mice were infected by intracisternal injection of live Streptococcus pneumoniae. Sixteen hours after infection, all mice developed meningitis as documented by positive bacterial cultures of the cerebrospinal fluid. Sixty percent of infected C57BL/6 mice survived more than 40 h after infection (50% of CD1, 0% of BALB/c). Histological evaluations of brain sections revealed apoptosis in the dentate gyrus of the hippocampus in 27% of infected C57BL/6 and in 5% of infected CD1 mice. Apoptosis was confirmed by immunoassaying for active caspase-3 and by TUNEL staining. Other forms of brain damage were found exclusively in C57BL/6, i.e. caspase-3 independent (pyknotic) cell death in the dentate gyrus in 2% and cortical damage in 11% of infected mice. This model may prove useful for studies on the pathogenesis of brain injury in childhood bacterial meningitis.
Resumo:
The Acoustic emission (AE) technique, as one of non-intrusive and nondestructive evaluation techniques, acquires and analyzes the signals emitting from deformation or fracture of materials/structures under service loading. The AE technique has been successfully applied in damage detection in various materials such as metal, alloy, concrete, polymers and other composite materials. In this study, the AE technique was used for detecting crack behavior within concrete specimens under mechanical and environmental frost loadings. The instrumentations of the AE system used in this study include a low-frequency AE sensor, a computer-based data acquisition device and a preamplifier linking the AE sensor and the data acquisition device. The AE system purchased from Mistras Group was used in this study. The AE technique was applied to detect damage with the following laboratory tests: the pencil lead test, the mechanical three-point single-edge notched beam bending (SEB) test, and the freeze-thaw damage test. Firstly, the pencil lead test was conducted to verify the attenuation phenomenon of AE signals through concrete materials. The value of attenuation was also quantified. Also, the obtained signals indicated that this AE system was properly setup to detect damage in concrete. Secondly, the SEB test with lab-prepared concrete beam was conducted by employing Mechanical Testing System (MTS) and AE system. The cumulative AE events and the measured loading curves, which both used the crack-tip open displacement (CTOD) as the horizontal coordinate, were plotted. It was found that the detected AE events were qualitatively correlated with the global force-displacement behavior of the specimen. The Weibull distribution was vii proposed to quantitatively describe the rupture probability density function. The linear regression analysis was conducted to calibrate the Weibull distribution parameters with detected AE signals and to predict the rupture probability as a function of CTOD for the specimen. Finally, the controlled concrete freeze-thaw cyclic tests were designed and the AE technique was planned to investigate the internal frost damage process of concrete specimens.
Resumo:
OBJECTIVES: To study the three-dimensional (3D) T1 patterns in different types of femoroacetabular impingement (FAI) by utilizing delayed gadolinium-enhanced magnetic resonance imaging (MRI) of cartilage (dGEMRIC) and subsequent 3D T1 mapping. We used standard grading of OA by Tonnis grade on standard radiographs and morphological grading of cartilage in MRI for comparative analysis. METHODS: dGEMRIC was obtained from ten asymptomatic young-adult volunteers and 26 symptomatic FAI patients. MRI included the routine hip protocol and a dual-flip angle (FA) 3D gradient echo (GRE) sequence utilizing inline T1 measurement. Cartilage was morphologically classified from the radial images based on the extent of degeneration as: no degeneration, degeneration zone measuring <0.75 cm from the rim, >0.75 cm, or total loss. T1 findings were evaluated and correlated. RESULTS: All FAI types revealed remarkably lower T1 mean values in comparison to asymptomatic volunteers in all regions of interest. Distribution of the T1 dGEMRIC values was in accordance with the specific FAI damage pattern. In cam-types (n=6) there was a significant drop (P<0.05) of T1 in the anterior to superior location. In pincer-types (n=7), there was a generalized circumferential decrease noted. High inter-observer (intra-observer) reliability was noted for T1 assessment using intra-class correlation (ICC):intra-class coefficient=0.89 (0.95). CONCLUSIONS: We conclude that a pattern of zonal T1 variation does seem to exist that is unique for different sub-groups of FAI. The FA GRE approach to perform 3D T1 mapping has a promising role for further studies of standard MRI and dGEMRIC in the hip joint.
Resumo:
AB A fundamental capacity of the human brain is to learn relations (contingencies) between environmental stimuli and the consequences of their occurrence. Some contingencies are probabilistic; that is, they predict an event in some situations but not in all. Animal studies suggest that damage to limbic structures or the prefrontal cortex may disturb probabilistic learning. The authors studied the learning of probabilistic contingencies in amnesic patients with limbic lesions, patients with prefrontal cortex damage, and healthy controls. Across 120 trials, participants learned contingent relations between spatial sequences and a button press. Amnesic patients had learning comparable to that of control subjects but failed to indicate what they had learned. Across the last 60 trials, amnesic patients and control subjects learned to avoid a noncontingent choice better than frontal patients. These results indicate that probabilistic learning does not depend on the brain structures supporting declarative memory.
Resumo:
PURPOSE The aim of the paper is to identify, review, analyze, and summarize available evidence in three areas on the use of cross-sectional imaging, specifically maxillofacial cone beam computed tomography (CBCT) in pre- and postoperative dental implant therapy: (1) Available clinical use guidelines, (2) indications and contraindications for use, and (3) assessment of associated radiation dose risk. MATERIALS AND METHODS Three focused questions were developed to address the aims. A systematic literature review was performed using a PICO-based search strategy based on MeSH key words specific to each focused question of English-language publications indexed in the MEDLINE database retrospectively from October 31, 2012. These results were supplemented by a hand search and gray literature search. RESULTS Twelve publications were identified providing guidelines for the use of cross-sectional radiography, particularly CBCT imaging, for the pre- and/or postoperative assessment of potential dental implant sites. The publications discovered by the PICO strategy (43 articles), hand (12), and gray literature searches (1) for the second focus question regarding indications and contraindications for CBCT use in implant dentistry were either cohort or case-controlled studies. For the third question on the assessment of associated radiation dose risk, a total of 22 articles were included. Publication characteristics and themes were summarized in tabular format. CONCLUSIONS The reported indications for CBCT use in implant dentistry vary from preoperative analysis regarding specific anatomic considerations, site development using grafts, and computer-assisted treatment planning to postoperative evaluation focusing on complications due to damage of neurovascular structures. Effective doses for different CBCT devices exhibit a wide range with the lowest dose being almost 100 times less than the highest dose. Significant dose reduction can be achieved by adjusting operating parameters, including exposure factors and reducing the field of view (FOV) to the actual region of interest.
Resumo:
Botryoid odontogenic cysts (BOC) are considered to be rare polycystic variants of lateral periodontal cysts characterized by a multilocular growth pattern. The most frequent location of BOC is the mandible, predominantly the premolar-canine area, followed by the anterior region of the maxilla. The cyst shows a slight female predilection. This case report of a BOC demonstrates a treatment with initial fenestration and decompression of the cyst in order to prevent damage to adjacent structures such as the inferior alveolar nerve. The present case report emphasizes the importance of accurate clinical, radiographic, and histologic diagnostic procedures of unspecific radiolucent lesions in the jaws to establish a firm diagnosis and avoid inappropriate treatment strategies.
Resumo:
FUS/TLS (fused in sarcoma/translocated in liposarcoma), a ubiquitously expressed RNA-binding protein, has been linked to a variety of cellular processes, including RNA metabolism, microRNA biogenesis and DNA repair. However, the precise cellular function of FUS remains unclear. Recently, mutations in the FUS gene have been found in ∼5% of familial Amyotrophic Lateral Sclerosis, a neurodegenerative disorder characterized by the dysfunction and death of motor neurons. Since MEFs and B-lymphocytes derived from FUS knockdown mice display major sensitivity to ionizing radiation and chromosomal aberrations [1,2], we are investigating the effects of DNA damage both in the presence or in the absence of FUS. To this purpose, we have generated a SH-SY5Y human neuroblastoma cell line expressing a doxycycline-induced shRNA targeting FUS, which specifically depletes the protein. We have found that FUS depletion induces an activation of the DNA damage response (DDR). However, treatment with genotoxic agents did not induce any strong changes in ATM (Ataxia Telangiectasia Mutated)-mediated DDR signaling. Interestingly, genotoxic treatment results in changes in the subcellular localization of FUS in normal cells. We are currently exploring on one hand the mechanism by which FUS depletion leads to DNA damage, and on the other the functional significance of FUS relocalization after genotoxic stress.
Resumo:
PURPOSE The goal of this study was to investigate whether different computed tomography (CT) energy levels could supply additional information for the differentiation of dental materials for forensic investigations. METHODS Nine different commonly used restorative dental materials were investigated in this study. A total of 75 human third molars were filled with the restorative dental materials and then scanned using the forensic reference phantom in singlesource mode. The mean Hounsfield unit values and standard deviations (SDs) of each material were calculated at 120, 80 and 140 kVp. RESULTS Most of the dental materials could be differentiated at 120 kVp. We found that greater X-ray density of a material resulted in higher SDs and that the material volume could influence the measurements. CONCLUSION Differentiation of dental materials in CT was possible in many cases using single-energy CT scans at 120 kVp. Because of the number of dental restorative materials available and scanner and scan parameter dependence, as well as the CT imaging artifacts, the identification (in contrast to differentiation) was problematic.
Resumo:
Hips with a cam deformity are at risk for early cartilage degeneration, mainly in the anterolateral region of the joint. T1ρ MRI is a described technique for assessment of proteoglycan content in hyaline cartilage and subsequently early cartilage damage. In this study, 1.5 Tesla T1ρ MRI was performed on 20 asymptomatic hips with a cam deformity and compared to 16 healthy control hips. Cam deformity was defined as an alpha angle at 1:30 o'clock position over 60° and/or at 3:00 o'clock position over 50.5°. Hip cartilage was segmented and divided into four regions of interest (ROIs): anterolateral, anteromedial, posterolateral and posteromedial quadrants. Mean T1ρ value of the entire weight bearing cartilage in hips with a cam deformity (34.0 ± 4.6 ms) was significantly higher compared to control hips (31.3 ± 3.2 ms, p = 0.050). This difference reached significance in the anterolateral (p = 0.042) and posteromedial quadrants (p = 0.041). No significant correlation between the alpha angle and T1ρ values was detected. The results indicate cartilage damage occurs in hips with a cam deformity before symptoms occur. A significant difference in T1ρ values was found in the anterolateral quadrant, the area of direct engagement of the deformity, and in the posteromedial quadrant. To conclude, T1ρ MRI can detect early chondral damage in asymptomatic hips with a cam deformity. This article is protected by copyright. All rights reserved.
Resumo:
There is evidence that ultraviolet radiation (UVR) is increasing over certain locations on the Earth's surface. Of primary concern is the annual pattern of ozone depletion over Antarctica and the Southern Ocean. Reduction of ozone concentration selectively limits absorption of solar UV-B (290–320 nm), resulting in higher irradiance at the Earth's surface. The effects of ozone depletion on the human population and natural ecosystems, particularly the marine environment, are a matter of considerable concern. Indeed, marine plankton may serve as sensitive indicators of ozone depletion and UV-B fluctuations. Direct biological effects of UVR result from absorption of UV-B by DNA. Once absorbed, energy is dissipated by a variety of pathways, including covalent chemical reactions leading to the formation of photoproducts. The major types of photoproduct formed are cyclobutyl pyrimidine dimer (CPD) and pyrimidine(6-4)pyrimidone dimer [(6-4)PD]. Marine plankton repair these photoproducts using light-dependent photoenzymatic repair or nucleotide excision repair. The studies here show that fluctuations in CPD concentrations in the marine environment at Palmer Station, Antarctica correlate well with ozone concentration and UV-B irradiance at the Earth's surface. A comparison of photoproduct levels in marine plankton and DNA dosimeters show that bacterioplankton display higher resistance to solar UVR than phytoplankton in an ozone depleted environment. DNA damage in marine microorganisms was investigated during two separate latitudinal transects which covered a total range of 140°. We observed the same pattern of change in DNA damage levels in dosimeters and marine plankton as measured using two distinct quantitative techniques. Results from the transects show that differences in photosensitivity exist in marine plankton collected under varying UVR environments. Laboratory studies of Antarctic bacterial isolates confirm that marine bacterioplankton possess differences in survival, DNA damage induction, and repair following exposure to UVR. Results from DNA damage measurements during ozone season, along a latitudinal gradient, and in marine bacterial isolates suggest that changes in environmental UVR correlate with changes in UV-B induced DNA damage in marine microorganisms. Differences in the ability to tolerate UVR stress under different environmental conditions may determine the composition of the microbial communities inhabiting those environments. ^
Resumo:
Lung damage is a common side effect of chemotherapeutic drugs such as bleomycin. This study used a bleomycin mouse model which simulates the lung damage observed in humans. Noninvasive, in vivo cone-beam computed tomography (CBCT) was used to visualize and quantify fibrotic and inflammatory damage over the entire lung volume of mice. Bleomycin was used to induce pulmonary damage in vivo and the results from two CBCT systems, a micro-CT and flat panel CT (fpCT), were compared to histologic measurements, the standard method of murine lung damage quantification. Twenty C57BL/6 mice were given either 3 U/kg of bleomycin or saline intratracheally. The mice were scanned at baseline, before the administration of bleomycin, and then 10, 14, and 21 days afterward. At each time point, a subset of mice was sacrificed for histologic analysis. The resulting CT images were used to assess lung volume. Percent lung damage (PLD) was calculated for each mouse on both the fpCT (PLDfpcT) and the micro-CT (PLDμCT). Histologic PLD (PLDH) was calculated for each histologic section at each time point (day 10, n = 4; day 14, n = 4; day 21, n = 5; control group, n = 5). A linear regression was applied to the PLDfpCT vs. PLDH, PLDμCT vs. PLDH and PLDfpCT vs. PLDμCT distributions. This study did not demonstrate strong correlations between PLDCT and PLDH. The coefficient of determination, R, was 0.68 for PLDμCT vs. PLDH and 0.75 for the PLD fpCT vs. PLDH. The experimental issues identified from this study were: (1) inconsistent inflation of the lungs from scan to scan, (2) variable distribution of damage (one histologic section not representative of overall lung damage), (3) control mice not scanned with each group of bleomycin mice, (4) two CT systems caused long anesthesia time for the mice, and (5) respiratory gating did not hold the volume of lung constant throughout the scan. Addressing these issues might allow for further improvement of the correlation between PLDCT and PLDH. ^