992 resultados para Cycle tests
Resumo:
The treatment efficiency of laboratory wastewaters was evaluated and ecotoxicity tests with Chlorella vulgaris were performed on them to assess the safety of their environmental discharge. For chemical oxygen demand wastewaters, chromium (VI), mercury (II) and silver were efficiently removedby chemical treatments.Areduction of ecotoxicitywas achieved; nevertheless, an EC50 (effective concentration that causes a 50% inhibition in the algae growth) of 1.5% (v/v) indicated still high level of ecotoxicity. For chloride determination wastewaters, an efficient reduction of chromium and silver was achieved after treatment. Regarding the reduction of ecotoxicity observed, EC50 increased from 0.059% to 0.5%, only a 0.02% concentration in the aquatic environment would guarantee no effects. Wastewaters containing phenanthroline/iron (II) complex were treated by chemical oxidation. Treatmentwas satisfactory concerning chemical parameters, although an increase in ecotoxicitywas observed (EC50 reduced from 0.31% to 0.21%). The wastes from the kinetic study of persulphate and iodide reaction were treated with sodium bisulphite until colour was removed. Although they did not reveal significant ecotoxicity, only over 1% of the untreated waste produced observable effects over algae. Therefore, ecotoxicity tests could be considered a useful tool not only in laboratory effluents treatment, as shown, but also in hazardous wastewaters management.
Resumo:
Biodieselhas attracted considerable attention as a renewable, biodegradable, and nontoxic fuel and can contribute to solving the energy problems, significantly reducing the emission of gases which cause global warming. The first stage of this work was to simulate different alternative processes for producing biodiesel. The method used for the production of biodiesel is the transesterification of vegetable oilswith an alcohol in the presence of a catalyst. The raw materials used were palm oils and waste cooking oil. The second stage was a life cycle analysis for all alternatives under study, followed by an economic analysis for the alternatives that present minor impacts and which are more promising from an economic point of view. Finally,we proceeded to compare the different alternatives fromboth the point of view of life cycle and economic analysis. The feasibility of all processes was proven and the biodiesel obtained had good specifications. From the standpoint of life cycle analysis, the best alternative was the process of alkaline catalysiswith acid pretreatment for waste cooking oil. The economic analysis was done to the previous mentioned process and to the process that uses raw virgin oils, methanol, and sodium hydroxide. This process has lower investment costs but the process of alkaline catalysis with acid pre-treatment, whose main raw material is waste oil, is much more profitable and has less environmental impacts.
Resumo:
Relatório Final de Estágio apresentado à Escola Superior de Educação de Lisboa para obtenção do grau de mestre em Ensino do 1.º e do 2.º Ciclo do Ensino Básico
Resumo:
This study uses the process simulator ASPEN Plus and Life Cycle Assessment (LCA) to compare three process design alternatives for biodiesel production from waste vegetable oils that are: the conventional alkali-catalyzed process including a free fatty acids (FFAs) pre-treatment, the acid-catalyzed process, and the supercritical methanol process using propane as co-solvent. Results show that the supercritical methanol process using propane as co-solvent is the most environmentally favorable alternative. Its smaller steam consumption in comparison with the other process design alternatives leads to a lower contribution to the potential environmental impacts (PEI’s). The acid-catalyzed process generally shows the highest PEI’s, in particular due to the high energy requirements associated with methanol recovery operations.
Resumo:
This work shows the influence of using different allocation approaches when modelling the inventory analysis in a soybean biodiesel life cycle assessment (LCA). Results obtained using mass, energy and economic based allocations are compared, focusing on the following aspects: normalised potential environmental impact (PEI) categories, total PEI and relative contributions to the total PEI from each life cycle stage and environmental impact category. Similar results are obtained either using economic and energy based allocations. However, different results are obtained when mass based allocation is used when compared with the other two. This study also illustrates that using different allocation approaches in biodiesel LCA may influence the final conclusions, especially in comparative assertions, emphasising the need to perform a sensitivity analysis in the LCA interpretation step.
Resumo:
A recent trend in distributed computer-controlled systems (DCCS) is to interconnect the distributed computing elements by means of multi-point broadcast networks. Since the network medium is shared between a number of network nodes, access contention exists and must be solved by a medium access control (MAC) protocol. Usually, DCCS impose real-time constraints. In essence, by real-time constraints we mean that traffic must be sent and received within a bounded interval, otherwise a timing fault is said to occur. This motivates the use of communication networks with a MAC protocol that guarantees bounded access and response times to message requests. PROFIBUS is a communication network in which the MAC protocol is based on a simplified version of the timed-token protocol. In this paper we address the cycle time properties of the PROFIBUS MAC protocol, since the knowledge of these properties is of paramount importance for guaranteeing the real-time behaviour of a distributed computer-controlled system which is supported by this type of network.
Resumo:
This paper presents a layered Smart Grid architecture enhancing security and reliability, having the ability to act in order to maintain and correct infrastructure components without affecting the client service. The architecture presented is based in the core of well design software engineering, standing upon standards developed over the years. The layered Smart Grid offers a base tool to ease new standards and energy policies implementation. The ZigBee technology implementation test methodology for the Smart Grid is presented, and provides field tests using ZigBee technology to control the new Smart Grid architecture approach. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
Micro-abrasion wear tests with ball-cratering configuration are widely used. Sources of variability are already studied by different authors and conditions for testing are parameterized by BS EN 1071-6: 2007 standard which refers silicon carbide as abrasive. However, the use of other abrasives is possible and allowed. In this work, ball-cratering wear tests were performed using four different abrasive particles of three dissimilar materials: diamond, alumina and silicon carbide. Tests were carried out under the same conditions on a steel plate provided with TiB2 hard coating. For each abrasive, five different test durations were used allowing understanding the initial wear phenomena. Composition and shape of abrasive particles were investigated by SEM and EDS. Scar areas were observed by optical and electronic microscopy in order to understand the wear effects caused by each of them. Scar geometry and grooves were analyzed and compared. Wear coefficient was calculated for each situation. It was observed that diamond particles produce well-defined and circular wear scars. Different silicon carbide particles presented dissimilar results as consequence of distinct particle shape and size distribution.
Resumo:
Mestrado em Engenharia Química - Ramo Optimização Energética na Indústria Química
Resumo:
The market for emulsion polymers (latexes) is large and growing at the expense of other manufacturing processes that emit higher amounts of volatile organic solvents. The paint industry is not an exception and solvent-borne paints have been gradually substituted by aqueous paints. In their life-cycle, much of the aqueous paint used for architectural or decorative purposes will eventually be discharged into wastewater treatment facilities, where its polymeric nanoparticles (mainly acrylic and styrene-acrylic) can work as xenobiotics to the microbial communities present in activated sludge. It is well established that these materials are biocompatible at macroscopic scale. But is their behaviour the same at nanoscale? What happens to the polymeric nanoparticles during the activated sludge process? Do nanoparticles agregate and are discharged together with the sludge or remain in emulsion? How do microorganisms interact with these nanoparticles? Are nanoparticles degradated by them? Are they adsorbed? Are these nanoparticles toxic to the microbial community? To study the influence of these xenobiotics in the activated sludge process, an emulsion of cross-linked poly(butyl methacrylate) nanoparticles of ca. 50 nm diameter was produced and used as model compound. Activated sludge from a wastewater treatment plant was tested by the OCDE’s respiration inhibition test using several concentrations of PBMA nanoparticles. Particle aggregation was followed by Dynamic Light Scattering and microorganism surfaces were observed by Atomic Force Microscopy. Using sequential batch reactors (SBRs) and continuous reactors, both inoculated with activated sludge, the consumption of carbon, ammonia, nitrite and nitrate was monitored and compared, in the presence and absence of nanoparticles. No particles were detected in all treated waters by Dynamic Light Scattering. This can either mean that microorganisms can efficiently remove all polymer nanoparticles or that nanoparticles tend to aggregate and be naturally removed by precipitation. Nevertheless respiration inhibition tests demonstrated that microorganisms consume more oxygen in the presence of nanoparticles, which suggests a stress situation. It was also observed a slight decrease in the efficiency of nitrification in the presence of nanoparticles. AFM images showed that while the morphology of some organisms remained the same both in the presence and absence of nanoparticles, others assumed a rough surface with hilly like shapes of ca. 50 nm when exposed to nanoparticles. Nanoparticles are thus likely to be either incorporated or adsorbed at the surface of some organisms, increasing the overall respiration rate and decreasing nitrification efficiency. Thus, despite its biocompatibility at macroscopic scale, PBMA is likely to be no longer innocuous at nanoscale.
Resumo:
Nanocrystalline diamond (NCD) coatings offer an excellent alternative for tribological applications, preserving most of the intrinsic mechanical properties of polycrystalline CVD diamond and adding to it an extreme surface smoothness. Silicon nitride (Si3N4) ceramics are reported to guarantee high adhesion levels to CVD microcrystalline diamond coatings, but the NCD adhesion to Si3N4 is not yet well established. Micro-abrasion tests are appropriate for evaluating the abrasive wear resistance of a given surface, but they also provide information on thin film/substrate interfacial resistance, i.e., film adhesion. In this study, a comparison is made between the behaviour of NCD films deposited by hot-filament chemical vapour deposition (HFCVD) and microwave plasma assisted chemical vapour deposition (MPCVD) techniques. Silicon nitride (Si3N4) ceramic discs were selected as substrates. The NCD depositions by HFCVD and MPCVD were carried out using H2–CH4 and H2–CH4–N2 gas mixtures, respectively. An adequate set of growth parameters was chosen for each CVD technique, resulting in NCD films having a final thickness of 5 m. A micro-abrasion tribometer was used, with 3 m diamond grit as the abrasive slurry element. Experiments were carried out at a constant rotational speed (80 r.p.m.) and by varying the applied load in the range of 0.25–0.75 N. The wear rate for MPCVD NCD (3.7±0.8 × 10−5 m3N−1m−1) is compatible with those reported for microcrystalline CVD diamond. The HFCVD films displayed poorer adhesion to the Si3N4 ceramic substrates than the MPCVD ones. However, the HFCVD films show better wear resistance as a result of their higher crystallinity according to the UV Raman data, despite evidencing premature adhesion failure.
Resumo:
Ball rotating micro-abrasion tribometers are commonly used to carry out wear tests on thin hard coatings. In these tests, different kinds of abrasives were used, as alumina (Al2O3), silicon carbide (SiC) or diamond. In each kind of abrasive, several particle sizes can be used. Some studies were developed in order to evaluate the influence of the abrasive particle shape in the micro-abrasion process. Nevertheless, the particle size was not well correlated with the material removed amount and wear mechanisms. In this work, slurry of SiC abrasive in distilled water was used, with three different particles size. Initial surface topography was accessed by atomic force microscopy (AFM). Coating hardness measurements were performed with a micro-hardness tester. In order to evaluate the wear behaviour, a TiAlSiN thin hard film was used. The micro-abrasion tests were carried out with some different durations. The abrasive effect of the SiC particles was observed by scanning electron microscopy (SEM) both in the films (hard material) as in the substrate (soft material), after coating perforation. Wear grooves and removed material rate were compared and discussed.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do Grau de Mestre em Energia e Bioenergia
Resumo:
A serologic study was undertaken in a group of 43 patients with active paracoccidioidomycosis who were treated in the same form (ketoconazole), for identical periods of time (6 months), and folio wed-up for various periods posttherapy. The tests employed were agar gel immunodiffusion (AGID) and complement fixation (FC). Also studied were 50 sera from patients with proven histoplasmosis and pulmonary aspergilloma, 30 patients with culturaly proven tuberculosis as well as 92 specimens from healthy individuals, residents in the endemic area for paracoccidioidomycosis. A single lot of yeast filtrate antigen was used throughout the study. The value of each test was measured according to GALEN and GAMBINO6. Both tests were highly sensitive, 89 and 93% respectively. Regarding their specificity, the AGID was totally specific while the CF exhibited 96.6% and 97% specificity in front of tuberculosis patients and healthy individuals respectively and 82% in comparison with patients with other mycoses. The concept of predictive value, that is, the certainty one has in accepting a positive test as diagnostic of paracoccidioidomycosis, favored the AGID procedure (100%) over the CF test. The latter could sort out with 93% certainty a patient with paracoccidioidomycosis among a group of healthy individuals and with 97.5% in the case of TB patients; when the group in question was composed by individuals with other deep mycoses, such certainty was lower (81%). The above results indicate that both the AGID and the CF tests furnish results of high confidence; one should not relay, however, in the CF alone as a means to establish the specific diagnosis of paracoccidioidomycosis.
Resumo:
Indirect Immunofluorescence (IFA), Plaque Reduction Neutralization (PRN) and Haemagglutination Inhibition (HI) tests for measles antibodies were carried out in 197 sera obtained from umbilical cord and vaccinated children. The IFA was also applied to blood samples collected with filter paper. IFA results demonstrated that the test is relatively simple to perform, with good reproducibility for different antigen lots. Good correlation was obtained between IFA, PRN and HI antibody titers. Better correlation was demonstrated with IFA and PRN than with HI and PRN tests. Sensitivity of IFA in detecting antibody was less effective than PRN, however more effective than HI using rhesus monkey red blood cells. PRN antibody titers over 100 were detected by IFA but not by HI (9.7% with negative results). IFA may be of considerable practical use and able to substitute HI in Seroepidemiological surveys and to evaluate vaccine efficacy. It also can be simplified by employing filter paper collected samples.