999 resultados para Core diameter, deviation
Resumo:
To evaluate several protocols for the application of ultrasound during removal of cast posts with varying core configurations cemented with zinc phosphate. Sixty maxillary canines were distributed into three groups (n = 20): group 1 - core with 5 mm diameter/height and post diameter of 1.3 mm; groups 2 and 3 - core with the same diameter as the post (1.3 mm) and heights of 5 mm and 3 mm, respectively. Posts/cores were cemented using a standard technique with zinc phosphate cement. Each group was divided into two subgroups according to the ultrasonic vibration mode: point vibration - ultrasonic vibration applied to the core surface for 5 s, on each face totalling 25 s; alternate vibration - intermittent application of ultrasonic vibration for 10 s to the labial and lingual surfaces, 10 s to the mesial and distal surfaces and 5 s to the incisal surface, totalling 25 s. The specimens were submitted to the tensile test using an Instron machine (1 mm min(-1)) and results were analysed by anova and t-test. The failure type was also analysed. Statistical analysis showed significant differences between groups relating to the core preparations (P < 0.05). The lowest mean values of traction force were obtained for group 3 (46.1 +/- 7.7 N), followed by group 2 (89.0 +/- 2.7 N) and group 1 (160.4 +/- 7.5 N). Regarding ultrasonic vibration, the lowest mean was observed with alternate vibration (81.1 +/- 10.1 N), which was significantly lower than the point vibration (115.9 +/- 9.5 N) (P < 0.05). Cohesive failure occurred in all cases. A reduction in core diameter/height and intermittent ultrasonic application improved the removal of cast posts cemented with zinc phosphate.
Resumo:
Neste documento ´e feita a descrição detalhada da integração modular de um script no software OsiriX. O objectivo deste script ´e determinar o diâmetro central da artéria aorta a partir de uma Tomografia Computorizada. Para tal são abordados conceitos relacionados com a temática do processamento de imagem digital, tecnologias associadas, e.g., a norma DICOM e desenvolvimento de software. Como estudo preliminar, são analisados diversos visualizadores de imagens médica, utilizados para investigação ou mesmo comercializados. Foram realizadas duas implementações distintas do plugin. A primeira versão do plugin faz a invocação do script de processamento usando o ficheiro de estudo armazenado em disco; a segunda versão faz a passagem de dados através de um bloco de memória partilhada e utiliza o framework Java Native Interface. Por fim, é demonstrado todo o processo de aposição da Marcação CE de um dispositivo médico de classe IIa e obtenção da declaração de conformidade por parte de um Organismo Notificado. Utilizaram-se os Sistemas Operativos Mac OS X e Linux e as linguagens de programação Java, Objective-C e Python.
Resumo:
Sirt3 is a mitochondrial NAD(+)-dependent deacetylase that governs mitochondrial metabolism and reactive oxygen species homeostasis. Sirt3 deficiency has been reported to accelerate the development of the metabolic syndrome. However, the role of Sirt3 in atherosclerosis remains enigmatic. We aimed to investigate whether Sirt3 deficiency affects atherosclerosis, plaque vulnerability, and metabolic homeostasis. Low-density lipoprotein receptor knockout (LDLR(-/-)) and LDLR/Sirt3 double-knockout (Sirt3(-/-)LDLR(-/-)) mice were fed a high-cholesterol diet (1.25 % w/w) for 12 weeks. Atherosclerosis was assessed en face in thoraco-abdominal aortae and in cross sections of aortic roots. Sirt3 deletion led to hepatic mitochondrial protein hyperacetylation. Unexpectedly, though plasma malondialdehyde levels were elevated in Sirt3-deficient mice, Sirt3 deletion affected neither plaque burden nor features of plaque vulnerability (i.e., fibrous cap thickness and necrotic core diameter). Likewise, plaque macrophage and T cell infiltration as well as endothelial activation remained unaltered. Electron microscopy of aortic walls revealed no difference in mitochondrial microarchitecture between both groups. Interestingly, loss of Sirt3 was associated with accelerated weight gain and an impaired capacity to cope with rapid changes in nutrient supply as assessed by indirect calorimetry. Serum lipid levels and glucose tolerance were unaffected by Sirt3 deletion in LDLR(-/-) mice. Sirt3 deficiency does not affect atherosclerosis in LDLR(-/-) mice. However, Sirt3 controls systemic levels of oxidative stress, limits expedited weight gain, and allows rapid metabolic adaptation. Thus, Sirt3 may contribute to postponing cardiovascular risk factor development.
Resumo:
Different types of NPs (nanoparticles) are currently under development for diagnostic and therapeutic applications in the biomedical field, yet our knowledge about their possible effects and fate in living cells is still limited. In the present study, we examined the cellular response of human brain-derived endothelial cells to NPs of different size and structure: uncoated and oleic acid-coated iron oxide NPs (8-9 nm core), fluorescent 25 and 50 nm silica NPs, TiO2 NPs (21 nm mean core diameter) and PLGA [poly(lactic-co-glycolic acid)]-PEO [poly(ethylene oxide)] polymeric NPs (150 nm). We evaluated their uptake by the cells, and their localization, generation of oxidative stress and DNA-damaging effects in exposed cells. We show that NPs are internalized by human brain-derived endothelial cells; however, the extent of their intracellular uptake is dependent on the characteristics of the NPs. After their uptake by human brain-derived endothelial cells NPs are transported into the lysosomes of these cells, where they enhance the activation of lysosomal proteases. In brain-derived endothelial cells, NPs induce the production of an oxidative stress after exposure to iron oxide and TiO2 NPs, which is correlated with an increase in DNA strand breaks and defensive mechanisms that ultimately induce an autophagy process in the cells.
Resumo:
The effect of confinement on the magnetic structure of vortices of dipolar coupled ferromagnetic nanoelements is an issue of current interest, not only for academic reasons, but also for the potential impact in a number of promising applications. Most applications, such as nano-oscillators for wireless data transmission, benefit from the possibility of tailoring the vortex core magnetic pattern. We report a theoretical study of vortex nucleation in pairs of coaxial iron and Permalloy cylinders, with diameters ranging from 21nm to 150nm, and 12nm and 21nm thicknesses, separated by a non-magnetic layer. 12nm thick iron and Permalloy isolated (single) cylinders do not hold a vortex, and 21nm isolated cylinders hold a vortex. Our results indicate that one may tailor the magnetic structure of the vortices, and the relative chirality, by selecting the thickness of the non-magnetic spacer and the values of the cylinders diameters and thicknesses. Also, the dipolar interaction may induce vortex formation in pairs of 12nm thick nanocylinders and inhibit the formation of vortices in pairs of 21nm thick nanocylinders. These new phases are formed according to the value of the distance between the cylinderes. Furthermore, we show that the preparation route may control relative chirality and polarity of the vortex pair. For instance: by saturating a pair of Fe 81nm diameter, 21nm thickness cylinders, along the crystalline anisotropy direction, a pair of 36nm core diameter vortices, with same chirality and polarity is prepared. By saturating along the perpendicular direction, one prepares a 30nm diameter core vortex pair, with opposite chirality and opposite polarity. We also present a theoretical discussion of the impact of vortices on the thermal hysteresis of a pair of interface biased elliptical iron nanoelements, separated by an ultrathin nonmagnetic insulating layer. We have found that iron nanoelements exchange coupled to a noncompensated NiO substrate, display thermal hysteresis at room temperature, well below the iron Curie temperature. The thermal hysteresis consists in different sequences of magnetic states in the heating and cooling branches of a thermal loop, and originates in the thermal reduction of the interface field, and on the rearrangements of the magnetic structure at high temperatures, 5 produce by the strong dipolar coupling. The width of the thermal hysteresis varies from 500 K to 100 K for lateral dimensions of 125 nm x 65 nm and 145 nm x 65 nm. We focus on the thermal effects on two particular states: the antiparallel state, which has, at low temperatures, the interface biased nanoelement with the magnetization aligned with the interface field and the second nanoelement aligned opposite to the interface field; and in the parallel state, which has both nanoelements with the magnetization aligned with the interface field at low temperatures. We show that the dipolar interaction leads to enhanced thermal stability of the antiparallel state, and reduces the thermal stability of the parallel state. These states are the key phases in the application of pairs of ferromagnetic nanoelements, separated by a thin insulating layer, for tunneling magnetic memory cells. We have found that for a pair of 125nm x 65nm nanoelements, separated by 1.1nm, and low temperature interface field strength of 5.88kOe, the low temperature state (T = 100K) consists of a pair of nearly parallel buckle-states. This low temperature phase is kept with minor changes up to T= 249 K when the magnetization is reduced to 50% of the low temperature value due to nucleation of a vortex centered around the middle of the free surface nanoelement. By further increasing the temperature, there is another small change in the magnetization due to vortex motion. Apart from minor changes in the vortex position, the high temperature vortex state remains stable, in the cooling branch, down to low temperatures. We note that wide loop thermal hysteresis may pose limits on the design of tunneling magnetic memory cells
Resumo:
Os programas comerciais de transferência de embriões em éguas existem por mais de três décadas e são hoje uma das biotécnias mais utilizadas na reprodução assistida de equinos. O exame ultrassonográfico nos períodos pré e pós-cobertura de doadoras de embriões, assim como a avaliação de receptoras no momento da inovulação é de vital importância para o êxito de um programa de transferência de embriões. A ultrassonografia Doppler é uma técnica não-invasiva que permite a avaliação em tempo real da hemodinâmica do trato reprodutivo de animais de grande porte. Por fornecer detalhes anatômicos e informações imediatas sobre a fisiologia do fluxo sanguíneo de tecidos e órgãos, o exame doppler permite a avaliação do potencial ovulatório de folículos e do status funcional de corpo lúteo e útero, além de ser uma técnica auxiliar para o diagnóstico de distúrbios na hemodinâmica do sistema reprodutivo. Alterações na perfusão sanguínea dos futuros folículos dominantes são detectáveis em diferentes fases de seu desenvolvimento, como na divergência folicular e no período pré-ovulatório. A partir dessas informações, é possível determinar o princípio da atividade sexual e o momento ideal para o início de tratamentos superovulatórios e indutores de ovulação, assim como o momento mais apropriado para a realização de coberturas de éguas doadoras de embriões. A avaliação através do modo-Doppler do corpo lúteo e útero de éguas receptoras é também um instrumento auxiliar para a seleção de animais com perfil sérico de progesterona e ambiente uterino adequados para a sobrevivência do embrião e manutenção da gestação. Essa técnica pode ser útil ainda ao se avaliar a interação concepto-maternal. Apesar da aplicabilidade da tecnologia doppler dentro de programas de transferência de embriões, novos estudos visando a determinar padrões de normalidade e posterior caracterização de distúrbios de fluxo sanguíneo de trato reprodutivo ainda se fazem necessários.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Na primeira parte deste trabalho foram desenvolvidos estudos de magnetismo de rochas e paleomagnetismo em amostras de rochas vulcânicas do Nordeste brasileiro. As idades das amostras compreende os períodos Jurássico e Cretáceo. Com este objetivo foram amostradas quatro áreas tendo sido estudado um total de 496 amostras em 55 sítios. Para a coleta foi utilizada uma perfuradora portátil que extrai amostras de 2.5 cm de diâmetro. A orientação das amostras foi feita por meio de uma bússola magnética e de um clinômetro. Os espécimes foram submetidos a desmagnetizações por campo magnético alternado e em alguns poucos casos foi empregada a desmagnetização térmica. Atribuindo-se peso unitário a cada sítio foi determinada a direção média da magnetização remanescente característica de cada uma das áreas estudadas. As rochas vulcânicas do período Jurássico, localizadas na borda oeste da Bacia do Maranhão (Porto Franco-Estreito), apresentaram uma direção media em que D= 3.9°, I= -17.9° com α95= 9.3°, k= 17.9, N= 15 e todos os sítios apresentaram polaridade normal. Para esta área foi determinado o polo paleomagnético de coordenadas 85.3°N, 82.5°E (A95= 6.9º) que se localiza próximo a outros polos paleomagnéticos conhecidos para esse período. As rochas da borda leste da Bacia do Maranhão (Teresina-Picos-Floriano) de idade cretácica inferior apresentaram uma direção média de magnetização remanescente característica tal que D= 174.7°, I= +6.0º com α95= 2.8º, k= 122, N= 21 e todos os sítios apresentaram polaridade reversa. O polo paleomagnético associado a elas apresentou por coordenadas 83.6°N, 261.0°E (A95=1.9°) e mostrou concordância com outros polos sul americanos de mesma idade. No Rio Grande do Norte foi estudado um enxame de diques toleíticos também de idade cretácica inferior, cuja direção média da magnetização remanescente característica encontrada foi D= 186.6º, I= +20.6º com α95= 14.0° e k= 12.9, N= 10. Os sítios desta área apresentaram magnetizações com polaridades normal a reversa. O polo paleomagnético obtido se localiza em 80.6°N e 94.8°E com A95= 9.5°. O estudo das rochas vulcânicas da província magnética do Cabo de Santo Agostinho indicou para a região um valor de D= 0.4º, I= -20.6º com α95= 4.8° e k= 114, N= 9 para a magnetização remanescente característica. Todos os sítios apresentaram polaridade normal e o polo paleomagnético determinado apresentou as seguintes coordenadas: 87.6ºN, 135ºE com A95= 4.5º. Foi discutida a eliminação da variação secular das direções obtidas, de forma que cada polo apresentado nesta dissertação é verdadeiramente um polo paleomagnético. A análise dos minerais magnéticos portadores da remanência, efetuada por curvas termomagnéticas ou por difração de Raio-X, indicou na maior parte das ocorrências, a presença de titanomagnetita pobre em titânio. A presença de maguemita e algumas vezes hematita, na maior parte das vezes resultado de intemperismo, não anulou a magnetização termoremanente associada à época de formação da rocha, que foi determinada após a aplicação de técnicas de desmagnetização aos espécimes. Pelas curvas termomagnéticas obteve-se, para a maioria das amostras, uma temperatura de Curie entre 500 e 600ºC. Os casos mais freqüentes indicaram a ocorrência de titanomagnetita exsolvida, em que foram observadas a presença de uma fase próxima à magnetita e outra fase rica em titânio, próxima à ilmenita, resultado de oxidação de alta temperatura. A segunda parte do trabalho diz respeito à determinação da época de abertura do oceano Atlântico Sul por meio de dados paleomagnéticos. Entretanto ao invés de se utilizar o procedimento comumente encontrado na literatura, e que se baseia nas curvas de deriva polar aparente de cada continente, foi aplicado um teste estatístico que avalia a probabilidade de determinada posição relativa entre os continentes ser válida ou não, para determinado período em estudo. Assim foi aplicado um teste F a polos paleomagnéticos da África e da América do Sul, dos períodos Triássico, Jurássico, Cretáceo Inferior e Cretáceo Médio-Superior, tendo sido estudadas situações que reconstituem a posição pré-deriva dos continentes e configurações que simulem um afastamento entre eles. Os resultados dos testes estatísticos indicaram, dentro de uma probabilidade de erro de menos de 5%, que a configuração pré-deriva de Martin et al (1981) é compatível com os dados paleomagnéticos do Triássico, mas apresenta uma diferença significativa para os paleopolos de Jurássico, Cretáceo Inferior, Cretáceo Médio-Superior. Outras reconstruções pré-deriva testadas apresentaram o mesmo resultado. A comparação entre os polos paleomagnéticos da América do Sul e da África, segundo uma reconstrução que admite uma pequena abertura entre os continentes, como a proposta por Sclater et al (1977) para 110 m.a. atrás, indicou que os dados do Triássico não são compatíveis com este afastamento. Por outro lado os paleopolos do Jurássico e do Cretáceo Inferior, embora mais antigos que a data sugerida pela reconstrução, são consistentes com esta separação dentro de uma probabilidade de erro de menos de 5%. Os dados do Cretáceo Médio-Superior se mostraram consistentes com a reconstrução sugerida para 80 m.a. atrás por Francheteau (1973) e que propõe uma separação maior entre os continentes. Com base na premissa de deslocamentos de blocos continentais rígidos a análise dos resultados obtidos indicou que América do Sul e África estavam unidas por suas margens continentais opostas no período Triássico e que uma pequena separação entre estes continentes, provavelmente devida a uma rutura inicial, ocorreu no Jurássico e se manteve, então, aproximadamente estacionária até o início do Cretáceo Inferior. Esta conclusão difere da maior parte dos trabalhos que discutem a abertura do oceano Atlântico Sul. Os dados do Cretáceo Médio-Superior são compatíveis com um afastamento rápido e significativo entre os continentes naquele período.
Resumo:
Constant-pressure difference and constant-flow permeability tests were conducted on core samples from Ocean Drilling Program Legs 170 and 205 from the Costa Rica subduction zone representing pelagic carbonate and hemipelagic mud lithologies. Seven whole-round core samples from Sites 1040, 1253, and 1255 were tested for vertical permeabilities. The permeabilities of the pelagic carbonate sediments range from ~4 x 10**-16 to ~1 x 10**-15 m**2. The permeabilities of the hemipelagic mud sediments vary from ~2 x 10**-18 to ~4 x 10**-18 m**2. To further characterize the sediments, grain size, total carbon, and total inorganic carbon analyses were conducted.