989 resultados para Composite Resins


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study evaluated the spin concentration and the crystallinity in different classifications of dental composites as a function of the material condition (new, aged and expired). Specimens were obtained according to the factors: composites: Filtek P60, Filtek Z250, Filtek Z350XT, and Filtek Silorane; and material conditions: new, aged, and expired. The syringe composites underwent an accelerated aging protocol (Arrhenius model). The magnetic properties of the composites were characterized using Electron Paramagnetic Resonance (EPR) and the concentration of spins (number of spins/mass) was calculated. The crystallinity of the composites tested was characterized with X-ray diffraction (XRD). Filtek P60 and Filtek Z250 presented similarities in terms of spin concentration and crystallinity, irrespective of the material condition. The aging protocol influenced the composite Filmic Z350XT that exhibited a significant increase in the spin concentration. Besides, lower intensity peaks of the organic matrix and amorphous silica were also observed for both aged and expired Filtek Z350XT. Although a significant lower spin concentration was observed for the silorane composite in comparison to that of the methacrylates, a decrease in the relative intensity of peaks of the amorphous region related to the organic components in the diffractograms was observed. The material conditions tested influence the crystallinity and the magnetic properties of the composites evaluated. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to evaluate the influence of chlorhexidine and Er, Cr:YSGG laser irradiation on the bond strength and external adaptation in mixed healthy and caries-affected class V cavities before and after thermal cycling. Thirty-six cavity preparations were made in mixed class V buccal human molars, half of them being artificially caries-induced. Any remaining affected dentin was removed from the cavity with a round burr at low speed. The teeth were divided into six groups, according to cleaning agent for both healthy and caries-induced dentin: no treatment, chlorhexidine and erbium, chromium-doped: yttrium, scandium, gallium, garnet (Er,Cr:YSGG) laser irradiation. A Filtek P90 (3M ESPE, St Paul, MN, USA) silorane adhesive restorative system was used. The specimens were subjected to 5000 thermal cycles (5-55 degrees C 60 min). Epoxy replicas were obtained to characterize the external adaptation under scanning electron microscopy. The average percentages of non-continuous margins were 5.41% and 6.49% in enamel dentin before thermal cycling and 25% and 33.7% after thermal cycling, respectively. The caries-affected and laser irradiated cavities showed higher non-continuous margins. Thermal cycling was able to raise the percentage of non-continuous margin for all groups. Chlorhexidine did not affect the marginal adaptation results, and the Er,Cr:YSGG laser irradiation showed significantly worse results compared with the control group.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Ciência e Tecnologia de Materiais - FC

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Novos compósitos têm surgido no mercado especificamente destinados à confecção de restaurações estéticas posteriores. Entretanto, embora tais materiais apresentem resultados iniciais animadores, há a necessidade de comprovações adicionais para que possam ser utilizados com segurança. Resinas compostas posteriores são submetidas a estresses complexos de compressão e abrasão durante a mastigação e a aplicação de selantes superficiais tem sido relatada como forma de aumentar a resistência ao desgaste destes materiais. O presente trabalho teve como propósito avaliar a dureza e a resistência à compressão das resinas compostas Alert (Jeneric/Pentron), Ariston (Vivadent), Definite (Degussa), P60 (3M), Solitarie (Kulzer), Surefil (Dentsply) e Z100 (3M) após 90 dias de imersão em água destilada, recobertas com selante Protect It (Jeneric/Pentron) e submetidas à ciclagem mecânica (10.000 ciclos, 600N, 5Hz). Os ensaios de dureza (n=8) foram realizados em aparelho Wolpert, com diamante Vickers e peso de 50gf aplicado por 30 segundos, antes e após períodos de imersão de 30, 60 e 90 dias. Os ensaios de resistência à compressão (n=8) foram realizados somente após 90 dias, em corpos-de-prova cilíndricos medindo 8mm de altura por 4mm de diâmetro. Apenas os espécimes destinados à compressão foram ciclados mecanicamente. Os ensaios foram realizados em máquina MTS 810, equipada com célula de carga de 10kN (ciclagem) e 100kN (compressão) e velocidade de 0,5mm/min. Após análise de variância (p<0,05), os resultados mostraram, previamente à imersão, maiores valores de dureza para os materiais Z100 (74,253VHN) e Ariston (71,308VHN). A seguir, com valor semelhante à resina Ariston, mas inferior à resina Z100, apresentou-se o material Surefil (69,969VHN)...(Resumo completo, clicar acesso eletrônico abaixo)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Recentemente, foram lançados no mercado odontológico novos materiais estéticos para restaurações diretas em dentes posteriores, aos quais são atribuídas propriedades mais adequadas para essa indicação. Entretanto, as informações disponíveis são ainda muito escassas, gerando dúvidas quanto à sua real eficácia, sobre quais as diferenças de suas composições e propriedades físicas e mecânicas em relação aos materiais até então disponíveis e se, de fato, apresentam melhor performance clínica. Em vista do exposto, nos propusemos a estudar contração de polimerização, resistência à flexão e concentração de partículas inorgânicas, por massa e volume, de sete resinas compostas (Alert, Ariston, Solitaire, Definite, Filtek P60, Z-100 e Tetric Ceram). A contração de polimerização foi medida nos materiais inseridos em um anel plástico, e o registro das alterações, durante a polimerização, foi feito por meio de instrumento eletrônico de medida linear, que registra as alterações dimensionais, com sensibilidade de 1 mm. A resistência à flexão foi medida na máquina de ensaios mecânicos MTS 810 e a confecção dos corpos-de-prova e dos dispositivos para o ensaio foi orientada pela norma ISO no 4049:1988. A determinação do conteúdo de partículas inorgânicas por massa foi feita através da pesagem de uma porção de resina composta polimerizada antes e após a eliminação da fase orgânica em forno, à temperatura de 700oC. O porcentual volumétrico de partículas inorgânicas foi calculado com base no Princípio de Arquimedes. Foi determinado o volume da resina composta polimerizada, antes e após a eliminação da fase orgânica, pela diferença da massa do material pesado ao ar e imerso em água. Os dados de conteúdo de partículas inorgânicas por massa e por volume, de contração de polimerização e resistência à flexão foram submetidos...(Resumo completo, clicar acesso eletrônico abaixo)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Following the introduction of the acid-etching technique in enamel surface, direct attachment of orthodontic appliances on the surface of the tooth and/or restorations became a routine procedure in the assembly of the fixed devices. The attainment of a success result is related to the criterion attention to the details and the steps of the bonding technique, as well as, to the knowledge of the characteristics of the adhesive materials and orthodontic brackets. This paper presents some aspects of various types of brackets and adhesives materials.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Direct bonding of orthodontics attachments to the teeth or restoration has become a routine in fixed appliance therapy. The technique used seems to be simple, but meticulous attention to detail and steps, a thorough understanding of factors involved are needed to ensure a successful outcome into different surfaces. It is the purpose of this article to review concerning aspects to orthodontic bonding in enamel and restorations fabricated from different materials; affording assistance to the reader wiser accomplishment and successful procedure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to evaluate and compare the roughness and superficial morphology of enamel and a composite restorative resin after different bleaching techniques application. Material and Methods: Bovine incisors were selected and standardized cavities were prepared on the buccal surface, which were restored with composite resin. The teeth were distributed according to the following treatments: G1- bleaching with 10% carbamide peroxide (CP); G2 - bleaching with 38% hydrogen peroxide (HP); and G3 - bleaching with 38% of HP associated to light irradiation. For G1, the bleaching gel was applied for 8 hours daily during 21 days. For G2 and G3, 3 sessions were performed, consisting of 3 applications of 15 minutes each, with 7 days of intervals between the sessions. For G3, the LED (470nm) light was used to activate the bleaching agent for 6 minutes. The surface of enamel and composite resin were evaluated before and after the bleaching procedures using a roughness tester and an atomic force microscope. Results: The results showed significant differences in surface roughness of enamel after bleaching only for G1 (Wilcoxon, p<0.05). For composite resin, neither group showed a statistical difference compared to control (Mann-Whitney, p>0.05). Conclusion: It was concluded that the increase in the roughness of enamel occurred only after bleaching therapy using a gel with 10% of CP. The bleaching procedures evaluated in this investigation did not increase the roughness or cause changes in the superficial morphology of the composite resin.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Due to mechanical and aesthetic improvement properties, continuous fiber-reinforced composites have been developed to replace the metal framework in fixed partial dentures becoming an interesting alternative to conventional treatments. A male patient, 57 years old, attended at Fixed Partial Denture Clinic of Araraquara Dental School - UNESP, complaining about upper right first molar absence. After clinical examination, it was observed: upper right second molar with amalgam restoration and periodontal bone reduction and upper right second premolar unsatisfactory treated. Following the clinical conditions and the patient expectations, it was decided to use a fiber-reinforced composite resin to make a three-element fixed bridge. The patient showed full satisfaction with the aesthetic and functional results. The case has been followed up for 60 months.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study assessed the surface microhardness of compound resins cured by different light sources. Methods Three micro hybrid (Vit-l-escence, Amelogen Plus, Opallis) and one nanoparticle (Filtek Z350, 3M ESPETM Dental Products, St. Paul, USA) compound resins were selected. The resins were polymerized by a halogen light unit (Ultralux, Dabi Atlante, Ribeirão Preto, Brasil) with two tips, one semi-guided made of glass and another of painted acrylic and a LED-based source (UltraLume 2, Ultradent®, South Jordan, USA). Specimens constructed from a circular aluminum matrix were photopolymerized for 40 second after they received the compound resin and stored dry for 24 hours. After this period, a Vickers surface microhardness assay was performed, measuring the top (hardness 1) and base (hardness 2) surfaces four times each. Variance analyses were complemented by Newman-Keuls method, with significance set at 5%. Results The Opallis (FGM, Santa Catarina, Brasil) resin subjected to UltraLume 2 (Ultradent®, South Jordan, USA) obtained the lowest mean hardness values for the top surface. The Vit-l-escence (Ultradent®, South Jordan, USA) compound cured by Led UltraLume 2 (Ultradent®, South Jordan, USA) and by Ultralux PCP (Dabi Atlante, Ribeirão Preto, Brasil) halogen light obtained the highest mean hardness, followed by the Filtek Z350 (3M ESPETM Dental Products, St. Paul, USA) resin subjected to UltraLume 2 (Ultradent® South Jordan, USA). The Opallis (FGM, Santa Catarina, Brasil) resin cured by LED UltraLume 2 (Ultradent®, South Jordan, USA) also obtained the lowest mean hardness for the base surface and the Vit-L-Escence (Ultradent®, South Jordan, USA) resin obtained the highest value, followed by Amelogen Plus, when cured by Ultralux (Dabi Atlante, Ribeirão Preto, Brasil) using the semi-guided tip. Conclusion The polymerization and, consequently, the microhardness achieved by the LED unit was equivalent to those achieved by conventional halogen units for three of the four composites tested.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: It is known that self-etching adhesive systems can act as semi-permeable membranes. Objective: Evaluate the effects of additional layer of hydrophobic resin on the microtensile bond strength of self-etching one-bottle adhesives. Material and method: Sixty bovine incisors were used in this study. The facial enamel surfaces of the crowns were abraded with silicon carbide paper to expose flat, mid-coronal dentin surfaces. The following adhesives were used: Clearfil Tri S Bond (CTSB), AdheSE One (ADH) and One Coat  7.0 (OC). Each material was tested with and without applying an additional layer of hydrophobic material from the same manufacturer. Z-350 composite resin was inserted in three 1 mm increments. All adhesive restorative procedure was performed under simulated pulpal pressure and the microtensile test was performed immediately after curing the composite resin. Data were submitted to ANOVA and Tukey test (p < 0.05). Result: For all adhesives tested, the worst results were observed in groups which the additional layer of hydrophobic resin was not applied. Conclusion: The application of additional layer of hydrophobic material can improve the adhesion of self-etching all-in-one adhesive systems.