772 resultados para CONVENTIONAL HYBRID


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The aims of this study were to evaluate the safety and efficacy of laparoscopic abdominoperineal resection compared to conventional approach for surgical treatment of patients with distal rectal cancer presenting with incomplete response after chemoradiation. METHOD: Twenty eight patients with distal rectal adenocarcinoma were randomized to undergo surgical treatment by laparoscopic abdominoperineal resection or conventional approach and evaluated prospectively. Thirteen underwent laparoscopic abdominoperineal resection and 15 conventional approach. RESULTS: There was no significant difference (p<0,05) between the two studied groups regarding: gender, age, body mass index, patients with previous abdominal surgeries, intra and post operative complications, need for blood transfusion, hospital stay after surgery, length of resected segment and pathological staging. Mean operation time was 228 minutes for the laparoscopic abdominoperineal resection versus 284 minutes for the conventional approach (p=0.04). Mean anesthesia duration was shorter (p=0.03) for laparoscopic abdominoperineal resection when compared to conventional approach : 304 and 362 minutes, respectively. There was no need for conversion to open approach in this series. After a mean follow-up of 47.2 months and with the exclusion of two patients in the conventional abdominoperineal resection who presented with unsuspected synchronic metastasis during surgery, local recurrence was observed in two patients in the conventional group and in none in the laparoscopic group. CONCLUSIONS: We conclude that laparoscopic abdominoperineal resection is feasible, similar to conventional approach concerning surgery duration, intra operative morbidity, blood requirements and post operative morbidity. Larger number of cases and an extended follow-up are required to adequate evaluation of oncological results for patients undergoing laparoscopic abdominoperineal resection after chemoradiation for radical treatment of distal rectal cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis aims to develop an alternative active managed portfolio strategy based on companies‟ Fundamental and Technical Analysis and analyze its finals results. There is a big distinction between the two approaches and the main objective is to understand if it is possible to take advantage of both. With this in mind a Hybrid investment strategy for the US stock market, due to its dimension and liquidity, which was able to outperform the S&P 500 index, the benchmark, during both Bear and Bull Markets between 2000 and 2015.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although, the word “Love” in organizations is seen as a rare concept, but it has gained importance in management theoretical foundation. This study seeks to explore the companionate love in distinct of organizational forms (Private companies; Social organizations; NGO and IPSS) through interviews. The results propose that it is a tensional concept with a complex dynamic: tension of personal behavior, tension of professional behavior; tension of individual impact and tension of community impact. The love dynamic has common points to all organizations, but its expression depends on the specific form of the organization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Within the civil engineering field, the use of the Finite Element Method has acquired a significant importance, since numerical simulations have been employed in a broad field, which encloses the design, analysis and prediction of the structural behaviour of constructions and infrastructures. Nevertheless, these mathematical simulations can only be useful if all the mechanical properties of the materials, boundary conditions and damages are properly modelled. Therefore, it is required not only experimental data (static and/or dynamic tests) to provide references parameters, but also robust calibration methods able to model damage or other special structural conditions. The present paper addresses the model calibration of a footbridge bridge tested with static loads and ambient vibrations. Damage assessment was also carried out based on a hybrid numerical procedure, which combines discrete damage functions with sets of piecewise linear damage functions. Results from the model calibration shows that the model reproduces with good accuracy the experimental behaviour of the bridge.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effectiveness of prefabricated hybrid composite plates (HCPs) as a seismic retrofitting solution for damaged interior RC beam-column joints is experimentally studied. HCP is composed of a thin plate made of strain hardening cementitious composite (SHCC) reinforced with CFRP sheets/laminates. Two full-scale severely damaged interior beam-column joints are retrofitted using two different configurations of HCPs. The effectiveness of these retrofitting solutions mainly in terms of hysteretic response, dissipated energy, degradation of secant stiffness, displacement ductility and failure modes are compared to their virgin states. According to these criteria, both solutions resulted in superior responses regarding the ones registered in their virgin states.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two cytotypes (2n=4x=36 and 2n=6x=54) found in Salvinia minima Bak. are discussed, the first from Brazil and the second from Argentina. The hexaploid cytotype, presumably a hybrid between Salvinia minima and S. sprucei Kuhn, was collected from the Solimões River near Manaus, Brazil and from Trinidad. Discussing its intermediate morphology, the authors attemp to explain the hybridization as a result of the seasonal and sporadic occurrence of Salvinia sprucei in the Amazonian basin, assuming that the still unknown chromosome number of the latter species would correspond to the diploid level (2n=2x=18).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hybrid Composite Plate (HCP) is a reliable recently proposed retrofitting solution for concrete structures, which is composed of a strain hardening cementitious composite (SHCC) plate reinforced with Carbon Fibre Reinforced Polymer (CFRP). This system benefits from the synergetic advantages of these two composites, namely the high ductility of SHCC and the high tensile strength of CFRPs. In the materialstructural of HCP, the ultra-ductile SHCC plate acts as a suitable medium for stress transfer between CFRP laminates (bonded into the pre-sawn grooves executed on the SHCC plate) and the concrete substrate by means of a connection system made by either chemical anchors, adhesive, or a combination thereof. In comparison with traditional applications of FRP systems, HCP is a retrofitting solution that (i) is less susceptible to the detrimental effect of the lack of strength and soundness of the concrete cover in the strengthening effectiveness; (ii) assures higher durability for the strengthened elements and higher protection to the FRP component in terms of high temperatures and vandalism; and (iii) delays, or even, prevents detachment of concrete substrate. This paper describes the experimental program carried out, and presents and discusses the relevant results obtained on the assessment of the performance of HCP strengthened reinforced concrete (RC) beams subjected to flexural loading. Moreover, an analytical approach to estimate the ultimate flexural capacity of these beams is presented, which was complemented with a numerical strategy for predicting their load-deflection behaviour. By attaching HCP to the beams’ soffit, a significant increase in the flexural capacity at service, at yield initiation of the tension steel bars and at failure of the beams can be achieved, while satisfactory deflection ductility is assured and a high tensile capacity of the CFRP laminates is mobilized. Both analytical and numerical approaches have predicted with satisfactory agreement, the load-deflection response of the reference beam and the strengthened ones tested experimentally.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper aims to evaluate experimentally the potentialities of Hybrid Composite Plates (HCPs) technique for the shear strengthening of reinforced concrete (RC) beams that were previously subjected to intense damage in shear. HCP is a thin plate of Strain Hardening Cementitious Composite (SHCC) reinforced with Carbon Fiber Reinforced Polymer (CFRP) laminates. For this purpose, an experimental program composed of two series of beams (rectangular and T cross section) was executed to assess the strengthening efficiency of this technique. In the first step of this experimental program, the control beams, without steel stirrups, were loaded up to their shear failure, and fully unloaded. Then, these pre-damaged beams were shear strengthened by applying HCPs to their lateral faces by using a combination of epoxy adhesive and mechanical anchors. The bolts were applied with a certain torque in order to increase the concrete confinement. The obtained results showed that the increase of load carrying capacity of the damaged strengthened beams when HCPs were applied with epoxy adhesive and mechanical anchors was 2 and 2.5 times of the load carrying capacity of the corresponding reference beams (without HCPs) for the rectangular and T cross section beam series, respectively. To further explore the potentialities of the HCPs technique for the shear strengthening, the experimental tests were simulated using an advanced numerical model by a FEM-based computer program. After demonstration the good predictive performance of the numerical model, a parametric study was executed to highlight the influence of SHCC as an alternative for mortar, as well as the influence of torque level applied to the mechanical anchors, on the load carrying capacity of beams strengthened with the proposed technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An exterior body panel solution containing a polydicyclopentadiene skin attached to an interior metallic reinforcement through adhesive bonding is being studied to be applied in the MobiCar bonnet. With this solution is expected to achieve lightness, adequate structural integrity and cost-efficiency. However, there is uncertainty regarding to the bonnet adhesiveness since different metallic materials and adhesive types are being considered for its development. Thus, in this paper, several samples are tested through shear loading with the aim of understanding the loading magnitude expected by using polydicyclopentadiene, steel DC04+ZE and aluminum alloy AW5754-H111 as substrates adhesively bonded by an epoxy or a methacrylate. Methacrylate adhesive have shown greater shear strength in all types of adhesive joints. PDCPD joints presented the highest displacements. Surface degradation was considered adequate over abrading once none strength difference was seen between the different surface treatments. Steel treated by cataphoresis has shown the highest joint interface strength.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de Doutoramento Engenharia Têxtil

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Novel multifunctional porous films have been developed by the integration of magnetic CoFe2O4 (CFO) nanoparticles into poly(vinylidene fluoride)-Trifuoroethylene (P(VDF-TrFE)), taking advantage of the synergies of the magnetostrictive filler and the piezoelectric polymer. The porous films show a piezoelectric response with an effective d33 coefficient of -22 pC/N-1, a maximum magnetization of 12 emu.g-1 and a maximum magnetoelectric coefficient of 9 mV.cm-1.Oe-1. In this way, a multifunctional membrane has been developed suitable for advanced applications ranging from biomedical to water treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poly(vinylidene fluoride-trifluoroethylene)/NaY zeolite composite membranes were prepared by solvent casting and evaluated as a suitable drug release platform through the evaluation of loading and release of ibuprofen. The membranes were characterized at the morphological, structural and mechanical levels. The 1H-NMR spectra indicate that only the membranes with 16 and 32 % of NaY were useful for IBU encapsulation and the drug release was followed by UV-Vis spectroscopy. The release profile is independent of the zeolite content and can be described by the Korsmeyer-Peppas model. The membrane with 32 % zeolite content releases more than double IBU amount when compared with the membrane with 16 % showing that zeolite content allows tailoring membrane drug release content for specific applications. The drug release platform developed in this work is suitable for other drugs and applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Parchment stands for a multifaceted material made from animal skin, which has been used for centuries as a writing support or as bookbinding. Due to the historic value of objects made of parchment, understanding their degradation and their condition is of utmost importance to archives, libraries and museums, i.e., the assessment of parchment degradation is mandatory, although it is hard to do with traditional methodologies and tools for problem solving. Hence, in this work we will focus on the development of a hybrid decision support system, in terms of its knowledge representation and reasoning procedures, under a formal framework based on Logic Programming, complemented with an approach to computing centered on Artificial Neural Networks, to evaluate Parchment Degradation and the respective Degree-of-Confidence that one has on such a happening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent advances in computation allow for the integration of design and simulation of highly interrelated systems, such as hybrids of structural membranes and bending active elements. The engaged complexities of forces and logistics can be mediated through the development of materials with project specific properties and detailing. CNC knitting with high tenacity yarn enables this practice and offers an alternative to current woven membranes. The design and fabrication of an 8m high fabric tower through an interdisciplinary team of architects, structural and textile engineers, allowed to investigate means to design, specify, make and test CNC knit as material for hybrid structures in architectural scale. This paper shares the developed process, identifies challenges, potentials and future work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wireless body sensor networks (WBSNs) constitute a key technology for closing the loop between patients and healthcare providers, as WBSNs provide sensing ability, as well as mobility and portability, essential characteristics for wide acceptance of wireless healthcare technology. However, one important and difficult aspect of WBSNs is to provide data transmissions with quality of service, among other factors due to the antennas being small size and placed close to the body. Such transmissions cannot be fully provided without the assumption of a MAC protocol that solves the problems of the medium sharing. A vast number of MAC protocols conceived for wireless networks are based on random or scheduled schemes. This paper studies firstly the suitability of two MAC protocols, one using CSMA and the other TDMA, to transmit directly to the base station the signals collected continuously from multiple sensor nodes placed on the human body. Tests in a real scenario show that the beaconed TDMA MAC protocol presents an average packet loss ratio lower than CSMA. However, the average packet loss ratio is above 1.0 %. To improve this performance, which is of vital importance in areas such as e-health and ambient assisted living, a hybrid TDMA/CSMA scheme is proposed and tested in a real scenario with two WBSNs and four sensor nodes per WBSN. An average packet loss ratio lower than 0.2 % was obtained with the hybrid scheme. To achieve this significant improvement, the hybrid scheme uses a lightweight algorithm to control dynamically the start of the superframes. Scalability and traffic rate variation tests show that this strategy allows approximately ten WBSNs operating simultaneously without significant performance degradation.