963 resultados para CONCENTRATED LOADS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The planar and axisymmetric variable-density flows induced in a quiescent gas by a concentrated source of momentum that is simultaneously either a source or a sink of energy are investigated for application to the description of the velocity and temperature far fields in laminar gaseous jets with either large or small values of the initial jet-to-ambient temperature ratio. The source fluxes of momentum and heat are used to construct the characteristic scales of velocity and length in the region where the density differences are of the order of the ambient density, which is slender for the large values of the Reynolds number considered herein. The problem reduces to the integration of the dimensionless boundary-layer conservation equations, giving a solution that depends on the gas transport properties but is otherwise free of parameters. The boundary conditions at the jet exit for integration are obtained by analysing the self-similar flow that appears near the heat source in planar and axisymmetric configurations and also near the heat sink in the planar case. Numerical integrations of the boundary-layer equations with these conditions give solutions that describe accurately the velocity and temperature fields of very hot planar and round jets and also of very cold plane jets in the far field region where the density and temperature differences are comparable to the ambient values. Simple scaling arguments indicate that the point source description does not apply, however, to cold round jets, whose far field region is not large compared with the jet development region, as verified by numerical integrations

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esta tesis doctoral se ha centrado en el estudio de las cargas aerodinámicas no estacionario en romos cuerpos o no aerodinámicos (bluff bodies). Con este objetivo se han identificado y analizado los siguientes puntos: -Caracterización del flujo medido con diferentes tipos de tubos de Pitot y anemómetro de hilo caliente en condiciones de flujo no estacionario inestable generado por un túnel aerodinamico de ráfagas. -Diseño e integración de los montajes experimentales requeridos para medir las cargas de viento internas y externas que actúan sobre los cuerpos romos en condiciones de flujo de viento con ráfagas. -Implementación de modelos matemáticos semi-empíricos basados en flujo potencial y las teorías fenomenológicas pertinentes para simular los resultados experimentales. -En diversan condiciones de flujo con ráfagas, la identificación y el análisis de la influencia de los parámetros obtenida a partir de los modelos teóricos desarrollados. -Se proponen estimaciones empíricas para averiguar los valores adecuados de los parámetros que influyente, mediante el ajuste de los resultados experimentales y los predichos teóricamente. Los montajes experimentales se has reakizado en un tunel aerodinamico de circuito abierto, provisto de baja velocidad, cámara de ensayes cerrada, un nuevo concepto de mecanismo generador de ráfaga sinusoidal, diseñado y construido en el Instituto de Microgravedad "Ignacio Da Riva" de la Universidad Politécnica de Madrid, (IDR / UPM). La principal característica de este túnel aerodynamico es la capacidad de generar un flujo con un perfil de velocidad uniforme y una fluctuación sinusoidal en el tiempo. Se han realizado pruebas experimentales para estudiar el efecto de los flujos no estacionarios en cuerpos romos situados en el suelo. Se han propuesto dos modelos teóricos para diterminar las cargas de presión externas e internas respectivamente. Con el fin de satisfacer la necesidad de la crea ráfagas de viento sinusoidales para comprobar las predicciones de los modelos teóricos, se han obtenido velocidades de hasta 30 m/s y frecuencias ráfaga de hasta 10 Hz. La sección de la cámara de ensayos es de 0,39 m x 0,54 m, dimensiónes adecuadas para llevar a cabo experimentos con modelos de ensayos. Se muestra que en la gama de parámetros explorados los resultados experimentales están en buen acuerdo con las predicciones de los modelos teóricos. Se han realizado pruebas experimentales para estudiar los efectos del flujo no estacionario, las cuales pueden ayudar a aclarar el fenómeno de las cargas de presión externa sobre los cuerpos romos sometidos a ráfagas de viento: y tambien para determinan las cargas de presión interna, que dependen del tamaño de los orificios de ventilación de la construcción. Por último, se ha analizado la contribución de los términos provenientes del flujo no estacionario, y se han caracterizado o los saltos de presión debido a la pérdida no estacionario de presión a través de los orificios de ventilación. ABSTRACT This Doctoral dissertation has been focused to study the unsteady aerodynamic loads on bluff bodies. To this aim the following points have been identified and analyzed: -Characterization of the flow measured with different types of Pitot tubes and hot wire anemometer at unsteady flow conditions generated by a gust wind tunnel. -Design and integrating of the experimental setups required to measure the internal and external wind loads acting on bluff bodies at gusty wind flow conditions. -Implementation of semi-empirical mathematical models based on potential flow and relevant phenomenological theories to simulate the experimental results.-At various gusty flow conditions, extracting and analyzing the influence of parameters obtained from the developed theoretical models. -Empirical estimations are proposed to find out suitable values of the influencing parameters, by fitting the experimental and theoretically predicted results. The experimental setups are performed in an open circuit, closed test section, low speed wind tunnel, with a new sinusoidal gust generator mechanism concept, designed and built at the Instituto de Microgravedad “Ignacio Da Riva” of the Universidad Politécnica de Madrid, (IDR/UPM). The main characteristic of this wind tunnel is the ability to generate a flow with a uniform velocity profile and a sinusoidal time fluctuation of the speed. Experimental tests have been devoted to study the effect of unsteady flows on bluff bodies lying on the ground. Two theoretical models have been proposed to measure the external and internal pressure loads respectively. In order to meet the need of creating sinusoidal wind gusts to check the theoretical model predictions, the gust wind tunnel maximum flow speed and, gust frequency in the test section have been limited to 30 m/s and 10 Hz, respectively have been obtained. The test section is 0.39 m × 0.54 m, which is suitable to perform experiments with testing models. It is shown that, in the range of parameters explored, the experimental results are in good agreement with the theoretical model predictions. Experimental tests have been performed to study the unsteady flow effects, which can help in clarifying the phenomenon of the external pressure loads on bluff bodies under gusty winds: and also to study internal pressure loads, which depend on the size of the venting holes of the building. Finally, the contribution of the unsteady flow terms in the theoretical model has been analyzed, and the pressure jumps due to the unsteady pressure losses through the venting holes have been characterized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Underspanned suspension bridges are structures with important economical and aesthetic advantages, due to their high structural efficiency. However, road bridges of this typology are still uncommon because of limited knowledge about this structural system. In particular, there remains some uncertainty over the dynamic behaviour of these bridges, due to their extreme lightness. The vibrations produced by vehicles crossing the viaduct are one of the main concerns. In this work, traffic-induced dynamic effects on this kind of viaduct are addressed by means of vehicle-bridge dynamic interaction models. A finite element method is used for the structure, and multibody dynamic models for the vehicles, while interaction is represented by means of the penalty method. Road roughness is included in this model in such a way that the fact that profiles under left and right tyres are different, but not independent, is taken into account. In addition, free software {PRPgenerator) to generate these profiles is presented in this paper. The structural dynamic sensitivity of underspanned suspension bridges was found to be considerable, as well as the dynamic amplification factors and deck accelerations. It was also found that vehicle speed has a relevant influence on the results. In addition, the impact of bridge deformation on vehicle vibration was addressed, and the effect on the comfort of vehicle users was shown to be negligible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The design of shell and spatial structures represents an important challenge even with the use of the modern computer technology.If we concentrate in the concrete shell structures many problems must be faced,such as the conceptual and structural disposition, optimal shape design, analysis, construction methods, details etc. and all these problems are interconnected among them. As an example the shape optimization requires the use of several disciplines like structural analysis, sensitivity analysis, optimization strategies and geometrical design concepts. Similar comments can be applied to other space structures such as steel trusses with single or double shape and tension structures. In relation to the analysis the Finite Element Method appears to be the most extended and versatile technique used in the practice. In the application of this method several issues arise. First the derivation of the pertinent shell theory or alternatively the degenerated 3-D solid approach should be chosen. According to the previous election the suitable FE model has to be adopted i.e. the displacement,stress or mixed formulated element. The good behavior of the shell structures under dead loads that are carried out towards the supports by mainly compressive stresses is impaired by the high imperfection sensitivity usually exhibited by these structures. This last effect is important particularly if large deformation and material nonlinearities of the shell may interact unfavorably, as can be the case for thin reinforced shells. In this respect the study of the stability of the shell represents a compulsory step in the analysis. Therefore there are currently very active fields of research such as the different descriptions of consistent nonlinear shell models given by Simo, Fox and Rifai, Mantzenmiller and Buchter and Ramm among others, the consistent formulation of efficient tangent stiffness as the one presented by Ortiz and Schweizerhof and Wringgers, with application to concrete shells exhibiting creep behavior given by Scordelis and coworkers; and finally the development of numerical techniques needed to trace the nonlinear response of the structure. The objective of this paper is concentrated in the last research aspect i.e. in the presentation of a state-of-the-art on the existing solution techniques for nonlinear analysis of structures. In this presentation the following excellent reviews on this subject will be mainly used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Civil buildings are not specifically designed to support blast loads, but it is important to take into account these potential scenarios because of their catastrophic effects, on persons and structures. A practical way to consider explosions on reinforced concrete structures is necessary. With this objective we propose a methodology to evaluate blast loads on large concrete buildings, using LS-DYNA code for calculation, with Lagrangian finite elements and explicit time integration. The methodology has three steps. First, individual structural elements of the building like columns and slabs are studied, using continuum 3D elements models subjected to blast loads. In these models reinforced concrete is represented with high precision, using advanced material models such as CSCM_CONCRETE model, and segregated rebars constrained within the continuum mesh. Regrettably this approach cannot be used for large structures because of its excessive computational cost. Second, models based on structural elements are developed, using shells and beam elements. In these models concrete is represented using CONCRETE_EC2 model and segregated rebars with offset formulation, being calibrated with continuum elements models from step one to obtain the same structural response: displacement, velocity, acceleration, damage and erosion. Third, models basedon structural elements are used to develop large models of complete buildings. They are used to study the global response of buildings subjected to blast loads and progressive collapse. This article carries out different techniques needed to calibrate properly the models based on structural elements, using shells and beam elements, in order to provide results of sufficient accuracy that can be used with moderate computational cost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Artículo en base a extractos de la memoria del proyecto de rehabilitación de las naves 18 y 19 de Matadero Madrid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Brick facades are a construction type, strongly linked to local construction characteristics and methods. In Spain, particularly in Castilla, the facades have been built since the '80s with Castilian half foot (11.5 cm), resting on the edge of slabs. The design of these facades, to horizontal loads from wind, depending on the codes used, can lead to completely different valid solutions. Applying same loads, the facades studied with current European standard (Eurocode 6), have a maximum length of 7.1 m between supports, while the Spanish code, Technical Building Code - Structural Safety Masonry, (CTE SE-F), 8.4 m can be achieved. This represents an increase of flexural strength, depending on the calculation model used, which can reach until 8 times. This is due to the difference of the calculation method and the structural model in one and another standard, depending on if this facade is analyzed as a vertical or horizontal beam or by formation of a vertical or horizontal archh. This paper analyzes the constructive solution of the brick facades that results from applying Spanish or European standards and how it affects the model applied in the safety of the resulting facade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper provides a method applicable for the determination of flight loads for maneuvering aircraft, in which aerodynamic loads are calculated based on doublet lattice method, which contains three primary steps. Firstly, non-dimensional stability and control derivative coefficients are obtained through solving unsteady aerodynamics in subsonic flow based on a doublet lattice technical. These stability and control derivative coefficients are used in second step. Secondly, the simulation of aircraft dynamic maneuvers is completed utilizing fourth order Runge-Kutta method to solve motion equations in different maneuvers to gain response parameters of aircraft due to the motion of control surfaces. Finally, the response results calculated in the second step are introduced to the calculation of aerodynamic loads. Thus, total loads and loads distribution on different components of aircraft are obtained. According to the above method, abrupt pitching maneuvers, rolling maneuvers and yawing maneuvers are investigated respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Parabolic reflectors, also known as parabolic troughs, are widely used in solar thermal power plants. This kind of power plants is usually located on desert climates, where the combined action of wind and dust can be of paramount importance. In some cases it becomes necessary to protect these devices from the joined wind and sand action, which is normally accomplished through solid windbreaks. In this paper the results of a wind tunnel test campaign, of a scale parabolic trough row having different windward windbreaks, are reported. The windbreaks herein considered consist of a solid wall with an upper porous fence. Different geometrical configurations, varying the solid wall height and the separation between the parabolic trough row and the windbreak have been considered. From the measured time series, both the mean and peak values of the aerodynamic loads were determined. As it would be expected, mean aerodynamic drag, as well as peak values, decrease as the distance between the windbreak and the parabolic increases, and after a threshold value, such drag loads increase with the distance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose Concentrating Solar Power (CSP) plants based on parabolic troughs utilize auxiliary fuels (usually natural gas) to facilitate start-up operations, avoid freezing of HTF and increase power output. This practice has a significant effect on the environmental performance of the technology. The aim of this paper is to quantify the sustainability of CSP and to analyse how this is affected by hybridisation with different natural gas (NG) inputs. Methods A complete Life Cycle (LC) inventory was gathered for a commercial wet-cooled 50 MWe CSP plant based on parabolic troughs. A sensitivity analysis was conducted to evaluate the environmental performance of the plant operating with different NG inputs (between 0 and 35% of gross electricity generation). ReCiPe Europe (H) was used as LCA methodology. CML 2 baseline 2000 World and ReCiPe Europe E were used for comparative purposes. Cumulative Energy Demands (CED) and Energy Payback Times (EPT) were also determined for each scenario. Results and discussion Operation of CSP using solar energy only produced the following environmental profile: climate change 26.6 kg CO2 eq/KWh, human toxicity 13.1 kg 1,4-DB eq/KWh, marine ecotoxicity 276 g 1,4-DB eq/KWh, natural land transformation 0.005 m2/KWh, eutrophication 10.1 g P eq/KWh, acidification 166 g SO2 eq/KWh. Most of these impacts are associated with extraction of raw materials and manufacturing of plant components. The utilization NG transformed the environmental profile of the technology, placing increasing weight on impacts related to its operation and maintenance. Significantly higher impacts were observed on categories like climate change (311 kg CO2 eq/MWh when using 35 % NG), natural land transformation, terrestrial acidification and fossil depletion. Despite its fossil nature, the use of NG had a beneficial effect on other impact categories (human and marine toxicity, freshwater eutrophication and natural land transformation) due to the higher electricity output achieved. The overall environmental performance of CSP significantly deteriorated with the use of NG (single score 3.52 pt in solar only operation compared to 36.1 pt when using 35 % NG). Other sustainability parameters like EPT and CED also increased substantially as a result of higher NG inputs. Quasilinear second-degree polynomial relationships were calculated between various environmental performance parameters and NG contributions. Conclusions Energy input from auxiliary NG determines the environmental profile of the CSP plant. Aggregated analysis shows a deleterious effect on the overall environmental performance of the technology as a result of NG utilization. This is due primarily to higher impacts on environmental categories like climate change, natural land transformation, fossil fuel depletion and terrestrial acidification. NG may be used in a more sustainable and cost-effective manner in combined cycle power plants, which achieve higher energy conversion efficiencies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The environmental performance of a 50 MW parabolic trough Concentrated Solar Power (CSP) plant hybridised with different fuels was determined using a Life Cycle Assessment methodology. Six different scenarios were investigated, half of which involved hybridisation with fossil fuels (natural gas, coal and fuel oil), and the other three involved hybridisation with renewable fuels (wheat straw, wood pellets and biogas). Each scenario was compared to a solar-only operation. Nine different environmental categories as well as the Cumulative Energy Demand and the Energy Payback Time (EPT) were evaluated using Simapro software for 1 MWh of electricity produced. The results indicate a worse environmental performance for a CSP plant producing 12% of the electricity from fuel than in a solar-only operation for every indicator, except for the eutrophication and toxicity categories, whose results for the natural gas scenario are slightly better. In the climate change category, the results ranged between 26.9 and 187 kg CO2 eq/MWh, where a solar-only operation had the best results and coal hybridisation had the worst. Considering a weighted single score indicator, the environmental impact of the renewable fuels scenarios is approximately half of those considered in fossil fuels, with the straw scenario showing the best results, and the coal scenario the worstones. EPT for solar-only mode is 1.44 years, while hybridisation scenarios EPT vary in a range of 1.72 -1.83 years for straw and pellets respectively. The fuels with more embodied energy are biomethane and wood pellets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Concentrating Solar Power (CSP) plants typically incorporate one or various auxiliary boilers operating in parallel to the solar field to facilitate start up operations, provide system stability, avoid freezing of heat transfer fluid (HTF) and increase generation capacity. The environmental performance of these plants is highly influenced by the energy input and the type of auxiliary fuel, which in most cases is natural gas (NG). Replacing the NG with biogas or biomethane (BM) in commercial CSP installations is being considered as a means to produce electricity that is fully renewable and free from fossil inputs. Despite their renewable nature, the use of these biofuels also generates environmental impacts that need to be adequately identified and quantified. This paper investigates the environmental performance of a commercial wet-cooled parabolic trough 50 MWe CSP plant in Spain operating according to two strategies: solar-only, with minimum technically viable energy non-solar contribution; and hybrid operation, where 12 % of the electricity derives from auxiliary fuels (as permitted by Spanish legislation). The analysis was based on standard Life Cycle Assessment (LCA) methodology (ISO 14040-14040). The technical viability and the environmental profile of operating the CSP plant with different auxiliary fuels was evaluated, including: NG; biogas from an adjacent plant; and BM withdrawn from the gas network. The effect of using different substrates (biowaste, sewage sludge, grass and a mix of biowaste with animal manure) for the production of the biofuels was also investigated. The results showed that NG is responsible for most of the environmental damage associated with the operation of the plant in hybrid mode. Replacing NG with biogas resulted in a significant improvement of the environmental performance of the installation, primarily due to reduced impact in the following categories: natural land transformation, depletion of fossil resources, and climate change. However, despite the renewable nature of the biofuels, other environmental categories like human toxicity, eutrophication, acidification and marine ecotoxicity scored higher when using biogas and BM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This brief communication concerns the unsteady aerodynamic external pressure loads acting on a semi-circular bluff body lying on a floor under wind gusts and describes the theoretical model, experimental setup, and experimental results obtained. The experimental setup is based on an open circuit, closed test section, low speed wind tunnel, which includes a sinusoidal gust generating mechanism, designed and built at the Instituto de Microgravedad “Ignacio Da Riva” of the Universidad Politécnica de Madrid (IDR/UPM). Based on the potential flow theory, a theoretical model has been proposed to analyse the problem, and experimental tests have been performed to study the unsteady aerodynamic loads on a semi-circular bluff body. By fitting the theoretical model predictions with the experimental results, influencing parameters of the unsteady aerodynamic loads are ascertained. The values of these parameters can help in clarifying the phenomenon of the external pressure loads on semi-circular bluff body under various gust frequencies. The theoretical model proposed allows the pressure variation to be split into two contributions, a quasi-steady term and an unsteady term with a simple physical meaning

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is a continuation of a previous one, Sanz-Andrés, Santiago-Prowald, Baker and Quinn (J. Wind Eng. Ind. Aerodyn. 91 (2003) 925) concerning the loads generated on a structural panel (traffic sign) by vehicle running along the road, although obviously, the results are also applicable to the effects of other moving vehicles such as trains. The structural panel was modelized as a large plate whose largest dimension is perpendicular to the vehicle motion direction. In this paper a similar approach is used to develop a mathematical model for the vehicle-induced load on pedestrian barriers, modelized as a large plate whose largest dimension is parallel to the vehicle motion direction. The purpose of the work is to develop a model simple enough to give analytical results, although with the physical phenomena correctly accounted for, such as to be able to explain, at least qualitatively, the main characteristics of the phenomenon, as observed in the experiments performed by Quinn et al. (J. Wind Eng. Ind. Aerodyn. 89 (2001) 831). Actually, in spite of the model simplicity, results of the theoretical model show a reasonable good quantitative agreement with the experimental results. The aim of this and previous publications is to provide to the transport infrastructure community with some simple tools that can help to explain, and in some cases also to compute, the unsteady loading produced by moving vehicles on persons and installations placed close to the roads or tracks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of the loads on traffic sign panels in the current standards does not, in general, take into account the vehicle-induced loads, as explained by Quinn, Baker and Wright (QBW in what follows) (J. Wind Eng. Ind. Aerodyn. 89 (2001) 831). On the other hand, a report from Cali and Covert (CC) (J. Wind Eng. Ind. Aerodyn. 84 (2000) 87) indicates that in highway sign support structures, vehicle-induced loads have led to premature failures in some cases. The aim of this paper is to present a mathematical model for the vehicle-induced load on a flat sign panel, simple enough to give analytical results, but able to explain the main characteristics of the phenomenon. The results of the theoretical model help to explain the behaviour observed in the experiments performed in previous studies.