811 resultados para CFRP (Carbon Fibre Reinforced Polymer)
Resumo:
In this work, a steel heated pultrusion die was designed, developed and manufactured to produce U200 glass fibre reinforced thermosetting matrix (GRP) profiles. The finite element analysis (FEA) was used to predict and optimise the developed die heating by using cylindrical electrical powered cartridges. To assess the new die performance it was mounted in the 120 kN pultrusion line of the Portuguese company Vidropol SA and used to produce continuously U200 profiles able to meet all requirements specified for the E23 grade accordingly to the European Standard EN 13706: 2002. After setting up the type, orientation and sequence of layers in laminate, orthophthalic, isophthalic and bisphenolic unsaturated polyester as well as vinylester resins were used to produce glass fibre reinforced U 200 composite profiles. An appropriated catalyst system was selected and the processing variables optimised for each case, namely, pultrusion pull-speed and die temperature. Finally, the produced U200 profiles were submitted to visual inspection, calcination and mechanical tests, namely, flexural, tensional and interlaminar shear strength (ILSS) tests, to assess their accomplishment with the EN 13706 requirements.
Resumo:
In this work, a new steel heated pultrusion die was designed, developed and manufactured to produce U200 glass fibre reinforced thermosetting matrix (GRP) profiles. The finite element analysis (FEA) was used to predict and optimise the developed die heating by using cylindrical electrical powered cartridges. To assess the new die performance it was mounted in the 120 kN pultrusion line of the Portuguese company Vidropol SA and used to produce continuously U200 profiles able to meet all requirements specified for the E23 grade accordingly to the European Standard EN 13706: 2002. After setting up the type, orientation and sequence of layers in the U 200 laminate, different types of thermosetting resins were used in its production. Orthophthalic, isophthalic and bisphenolic unsaturated polyester as well as vinylester resins were used to produce glass fibre reinforced U 200 composite profiles. All applied resins were submitted to SPI gel tests in order to select the more appropriated catalyst system and optimise the processing variables to be used in each case, namely, pultrusion pull-speed and die temperature. The best pultrusion operational conditions were selected by varying and monitoring the pull-speed and die temperature and, at the same time, measuring the temperature on the manufactured U 200 profile during processing. Finally, the produced U200 profiles were submitted to visual inspection, calcination and mechanical tests, namely, flexural, tensional and interlaminar shear strength (ILSS) tests, to assess their accomplishment with the EN 13706 requirements.
Resumo:
The behaviour of masonry elements under in-plane and out-of-plane loads can be improved through the application of strengthening systems based on reinforcing overlays. After strengthening, the transition region between the original substrate and the strengthening layer is especially stressed, and premature failure of the strengthened masonry is reached if insufficient interfacial capacity is assured. Therefore, the assessment of the mechanical behaviour of the interface is critical to the development of the masonry strengthening system based on the application of strengthening overlays. In this research a method for the characterization of the interface behaviour between two different materials, a polypropylene fibre reinforced mortar (PFRM) and a ceramic brick used for masonry construction is presented. Direct shear tests were carried out in couplet specimens. Due to the orthotropic nature of the bricks surface, the shear load was applied along three different directions in order to perform an overall estimation of the interface behaviour. The peak and residual shear stresses, as well as the failure modes, were obtained at different levels of the normal stress. Based on these experimental results constitutive laws were assessed for the simulation of the interface mechanical behaviour based on the Mohr and Mohr-Coulomb failure criteria.
Resumo:
Tese de Doutoramento em Engenharia Têxtil
Resumo:
L'objectiu d'aquest projecte és el disseny dels bancs d'assaig necessaris per poder realitzar tres assajos de fisuració i deformació diferida al laboratori de resistència de materials de la UdGsobre provetes i bigues de formigó armat amb FRP i estudiar- ne el comportament. El primer assaig és el de fluència del formigó, on es sotmet una proveta a una compressió mantinguda en el temps. El segon assaig és un de tracció directa, on s'aplica una càrrega a tracció mantinguda en el temps en una proveta de formigó armat amb una barra FRP de reforç intern. El tercer és un assaig a flexió, on es carregarà una biga a flexió durant un període llarg de temps
Resumo:
Aquest treball final de carrera és un estudi del reforç d’un element estructural de formigó per mitjà de fibres FRP. Podem assimilar-lo a una guia pràctica per tal que un enginyer ambconeixements de construcció, pugui reforçar un membre que ha sofert danys produïts peraguantar càrregues, oscil·lacions, etc.per les que no havia estat dissenyat. El projecte conté teoria del FRP per tal de conèixer el material que utilitzarem pel nostre reforç, les normatives i prenormatives que s’utilitzen per fer el disseny, i un exemple pràctic de càlcul del reforç d’una biga sotmesa a flexió i el confinament d’un pilar, que són les dues opcions més utilitzades per reforçar amb FRP. El reforç d’estructures de formigó és el camp de la construcció on més ràpidament i amb major èxit s’estan aplicant els reforços amb FRP, degut a les propietats tant avantatjoses que presenten, entre altres, resistència a la corrosió i lleugeresa, que es tradueix en estalvi de transport i posada en obra
Resumo:
Estudi experimental del comportament de bigues de formigó armades amb barres de materials compostos de matriu polimèrica (FRP)
Resumo:
El present treball s’emmarca dins el camp de les estructures de formigó, i mésconcretament, a les que es troben reforçades amb armadures de materials compostos amb matriu polimèrica, és a dir FRP “Fiber Reinforced Polymer”
Resumo:
The objective of this project consists of designing and constructing a RTM mould for a loose flange of glass fibre reinforced plastic (GRP). The design phase has the mission to realise a quality and simple design of the RTM mould, with the objective to obtain an easy and economic phase of construction and the more possible great characteristics of the loose flange. In fact this RTM mould will be a mould prototype, which will be developed in the future to obtain an RTM mould able to support a loose flange production. Therefore when more steps are developed in this project, then the future objective will be near
Resumo:
Structural concrete is one of the most commonly used construction materials in the United States. However, due to changes in design specifications, aging, vehicle impact, etc. – there is a need for new procedures for repairing concrete (reinforced or pretressed) superstructures and substructures. Thus, the overall objective of this investigation was to develop innovative cost effective repair methods for various concrete elements. In consultation with the project advisory committee, it was decided to evaluate the following three repair methods: • Carbon fiber reinforced polymers (CFRPs) for use in repairing damaged prestressed concrete bridges • Fiber reinforced polymers (FRPs) for preventing chloride penetration of bridge columns • Various patch materials The initial results of these evaluations are presented in this three volume final report. Each evaluation is briefly described in the following paragraphs. A more detailed abstract of each evaluation accompanies the volume on that particular investigation.
Resumo:
Structural concrete is one of the most commonly used construction materials in the United States. However, due to changes in design specifications, aging, vehicle impact, etc. – there is a need for new procedures for repairing concrete (reinforced or pretressed) superstructures and substructures. Thus, the overall objective of this investigation was to develop innovative cost effective repair methods for various concrete elements. In consultation with the project advisory committee, it was decided to evaluate the following three repair methods: • Carbon fiber reinforced polymers (CFRPs) for use in repairing damaged prestressed concrete bridges • Fiber reinforced polymers (FRPs) for preventing chloride penetration of bridge columns • Various patch materials The initial results of these evaluations are presented in this three volume final report. Each evaluation is briefly described in the following paragraphs. A more detailed abstract of each evaluation accompanies the volume on that particular investigation.
Resumo:
Transverse joints are placed in portland cement concrete pavements to control the development of random cracking due to stresses induced by moisture and thermal gradients and restrained slab movement. These joints are strengthened through the use of load transfer devices, typically dowel bars, designed to transfer load across the joint from one pavement slab to the next. Epoxy coated steel bars are the materials of choice at the present time, but have experienced some difficulties with resistance to corrosion from deicing salts. The research project investigated the use of alternative materials, dowel size and spacing to determine the benefits and limitations of each material. In this project two types of fiber composite materials, stainless steel solid dowels and epoxy coated dowels were tested for five years in side by side installation in a portion of U.S. 65 near Des Moines, Iowa, between 1997 and 2002. The work was directed at analyzing the load transfer characteristics of 8-in. vs. 12-in. spacing of the dowels and the alternative dowel materials, fiber composite (1.5- and 1.88-in. diameter) and stainless steel (1.5-in. diameter), compared to typical 1.5-in. diameter epoxy-coated steel dowels placed on 12-in. spacing. Data were collected biannually within each series of joints and variables in terms of load transfer in each lane (outer wheel path), visual distress, joint openings, and faulting in each wheel path. After five years of performance the following observations were made from the data collected. Each of the dowel materials is performing equally in terms of load transfer, joint movement and faulting. Stainless steel dowels are providing load transfer performance equal to or greater than epoxy-coated steel dowels at the end of five years. Fiber reinforced polymer (FRP) dowels of the sizes and materials tested should be spaced no greater than 8 in. apart to achieve comparable performance to epoxy coated dowels. No evidence of deterioration due to road salts was identified on any of the products tested. The relatively high cost of stainless steel solid and FRP dowels was a limitation at the time of this study conclusion. Work is continuing with the subject materials in laboratory studies to determine the proper shape, spacing, chemical composition and testing specification to make the FRP and stainless (clad or solid) dowels a viable alternative joint load transfer material for long lasting portland cement concrete pavements.
Resumo:
As truck traffic on Iowa secondary roads has increased, engineers have moved to concrete pavements of greater depths. Early designs included thickened edge pavements and depths of seven inches or greater. The designs typically did not have load transfer devices installed in the transverse joints and relied on aggregate interlock for this purpose. In some cases, aggregate interlock was not adequate to deal with the soils and traffic conditions and faulting of the joints has begun to appear. Engineers are now faced with the need to install or retrofit load transfer in the joints to preserve the pavements. Questions associated with this decision range from the type of dowel material to dowel diameter, spacing, number of bars, placement method, and construction techniques to be used to assure reduction or elimination of faulting. Buena Vista County constructed a dowel bar retrofit project on one mile of road. The plan called for addition of the dowels (2, 3, or 4) in the outer wheel path only and surface grinding in lieu of asphalt overlay. The project included the application of elliptical- and round-shaped dowels in a rehabilitation project. Dowel material types included conventional epoxy-coated steel and fiber-reinforced polymer (FRP). This work involved the determination of relative costs in materials to be used in this type of work and performance of FRP and elliptical-shaped steel dowels in the retrofit work. The results indicate good performance from each of the bar configurations and use the results of ride and deflection testing over the research period to project the benefits that can be gained from each configuration vs. the anticipated construction costs. The reader is cautioned that this project could not relate the number of dowels required to the level of anticipated truck traffic for other roads that might be considered.
Resumo:
Contractors, engineers, owners and manufacturers want to be certain that a new product or procedure will yield beneficial results when compared to the current method of construction. The following research was conducted in order to compare the performance of epoxy coated dowel bars to dowel bars of alternative shapes and materials such as stainless steel and glass fiber reinforced polymer (GFRP). Research was also done on the effect that dowel bar spacing has on the performance of concrete pavements. Four phases of this research are described in this report.
Resumo:
Diplomityö on tehty Exel Oyj:lle tuotekehityprojektina. Tarkoituksena on kehittää Exel Oyj:n valmistamaa komposiittipakkausrakennetta. Työssä on keskitytty valmistustekniseen selvitykseen komposiittirakenteen teollisen mittakaavan tuotannossa. Työssä selvitettiin erilaisten tuoterakenteiden valmistettavuutta sekä suoritettiin kyseisen tuotteen vaatimusprofiilin mukaisia testejä valituille rakennevaihtoehdoille. Pakkausrakenteelle asetettuja vaatimuksia ovat mm. kuljetusvaatimukset, jotka määräytyvät lähinnä NATO standardien pohjalta. Lisäksi tuotteelta vaaditaan tiettyä pitkäaikaiskestoa käsittelyn kannalta sekä soveltuvuutta vallitseviin ilmasto-olosuhteisiin. Vaatimusten mukaisia ominaisuuksia tutkittiin lisäksi mm. ballistisilla ja mekaanisilla testeillä sekä kaasuläpäisytesteillä. Testien pohjalta voidaan todeta, etteivät perinteisen alipaineinjektoidun komposiittituotteen ballistiset ominaisuudet ole riittävällä tasolla suojatuotetta ajatellen. Ballististen ja mekaanisten testien kesken havaittiin joitain yhtäläisyyksiä ja tämä vaikuttaa olevan nimenomaan mekaanisesti optimoidun komposiitin ominaisuus. DI-työn lopputuloksena on saatu selkeä kuva pakkausrakenteen materiaalivaihtoehtojen soveltuvuudesta kyseiselle tuotteelle. Lisäksi pakkausrakenteelle on ehdotettu neljä erilaista tuotesuunnitelmaan, niiden valmistustekniikat sekä lopputuotteen kustannusarviointi.