618 resultados para BALLOON


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In vitro studies have shown that stimulation of alpha1-adrenoceptors (ARs) directly induces proliferation, hypertrophy, and migration of arterial smooth muscle cells and adventitial fibroblasts. In vivo studies confirmed these findings and showed that catecholamine trophic activity becomes excessive after experimental balloon injury and contributes to neointimal growth, adventitial thickening, and lumen loss. However, past studies have been limited by selectivity of pharmacological agents. The aim of this study, in which mice devoid of norepinephrine and epinephrine synthesis [dopamine beta-hydroxylase (DBH-/-)] or deficient in alpha1-AR subtypes expressed in murine carotid (alpha1B-AR-/- and alpha1D-AR-/-) were used, was to test the hypothesis that catecholamines contribute to wall hypertrophy after injury. At 3 wk after injury of wild-type mice, lumen area and carotid circumference increased significantly, and hypertrophy of media and adventitia was in excess of that needed to restore circumferential wall stress to normal. In DBH-/- and alpha1B-AR-/- mice, increases in lumen area, circumference, and hypertrophy of the media and adventitia were reduced by 50-91%, resulting in restoration of wall tension to nearly normal (DBH-/-) or normal (alpha1B-AR-/-). In contrast, in alpha1D-AR-/- mice, increases in lumen area, circumference, and wall hypertrophy were unaffected and wall thickening remained in excess of that required to return tension to normal. When examined 5 days after injury, proliferation and leukocyte infiltration were inhibited in DBH-/- mice. These studies suggest that the trophic effects of catecholamines are mediated primarily by alpha1B-ARs in mouse carotid and contribute to hypertrophic growth after vascular injury.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

IMPORTANCE: Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE: To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING, AND PARTICIPANTS: Correlates for survival were evaluated using a multinational valve-in-valve registry that included 459 patients with degenerated bioprosthetic valves undergoing valve-in-valve implantation between 2007 and May 2013 in 55 centers (mean age, 77.6 [SD, 9.8] years; 56% men; median Society of Thoracic Surgeons mortality prediction score, 9.8% [interquartile range, 7.7%-16%]). Surgical valves were classified as small (≤21 mm; 29.7%), intermediate (>21 and <25 mm; 39.3%), and large (≥25 mm; 31%). Implanted devices included both balloon- and self-expandable valves. MAIN OUTCOMES AND MEASURES: Survival, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83.2% (95% CI, 80.8%-84.7%; 62 death events; 228 survivors). Patients in the stenosis group had worse 1-year survival (76.6%; 95% CI, 68.9%-83.1%; 34 deaths; 86 survivors) in comparison with the regurgitation group (91.2%; 95% CI, 85.7%-96.7%; 10 deaths; 76 survivors) and the combined group (83.9%; 95% CI, 76.8%-91%; 18 deaths; 66 survivors) (P = .01). Similarly, patients with small valves had worse 1-year survival (74.8% [95% CI, 66.2%-83.4%]; 27 deaths; 57 survivors) vs with intermediate-sized valves (81.8%; 95% CI, 75.3%-88.3%; 26 deaths; 92 survivors) and with large valves (93.3%; 95% CI, 85.7%-96.7%; 7 deaths; 73 survivors) (P = .001). Factors associated with mortality within 1 year included having small surgical bioprosthesis (≤21 mm; hazard ratio, 2.04; 95% CI, 1.14-3.67; P = .02) and baseline stenosis (vs regurgitation; hazard ratio, 3.07; 95% CI, 1.33-7.08; P = .008). CONCLUSIONS AND RELEVANCE: In this registry of patients who underwent transcatheter valve-in-valve implantation for degenerated bioprosthetic aortic valves, overall 1-year survival was 83.2%. Survival was lower among patients with small bioprostheses and those with predominant surgical valve stenosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Subclavian steal phenomenon due to proximal subclavian artery stenosis or occlusion is not un-common but often remains asymptomatic. We describe the case of a 66-year-old man with end-stage renal disease hemodialysed through a brachio-brachial loop graft of the left forearm. Echo-Doppler precerebral examination showed a high reversed flow of 570 ml/min in the ipsilateral vertebral artery. After successful endovascular recanalization of the subclavian artery, access blood flow increased and vertebral flow decreased to 30 ml/min. Complete neurological examination was normal both before and after endovascular treatment. This case demonstrates how high a subclavian steal can be without causing symptoms and how well precerbral and cerebral circulation can adapt to hemodynamic changes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

No-reflow phenomenon is a consequence of percutaneous coronary intervention (PCI) which arises most of the time in the setting of myocardial infarction, but can be also the consequence of PCI in stable angina patients (rotatablator ablation technique or angioplasty in saphenous vein grafts). In this review, we summarize two ways of treating the no-reflow according to the current literature. First through the pharmacological approach where several compounds have been assessed like adenosine, nitroprusside, verapamil, nicorandil, dipyridamole, epinephrine or cyclosporine. Second through the mechanical approach where few strategies have been examined like intra-aortic balloon pumping or postconditioning. Finally, we provide an algorithm for treating a no-reflow even though no studies showed a beneficial effect in terms of clinical endpoints.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Vertebral fracture (VF) is the most common osteoporotic fracture and is associated with high morbidity and mortality. Conservative treatment combining antalgic agents and rest is usually recommended for symptomatic VFs. The aim of this paper is to review the randomized controlled trials comparing the efficacy and safety of percutaneous vertebroplasty (VP) and percutaneous balloon kyphoplasty (KP) versus conservative treatment. VP and KP procedures are associated with an acceptable general safety. Although the case series investigating VP/KP have all shown an outstanding analgesic benefit, randomized controlled studies are rare and have yielded contradictory results. In several of these studies, a short-term analgesic benefit was observed, except in the prospective randomized sham-controlled studies. A long-term analgesic and functional benefit has rarely been noted. Several recent studies have shown that both VP and KP are associated with an increased risk of new VFs. These fractures are mostly VFs adjacent to the procedure, and they occur within a shorter time period than VFs in other locations. The main risk factors include the number of preexisting VFs, the number of VPs/KPs performed, age, decreased bone mineral density, and intradiscal cement leakage. It is therefore important to involve the patients to whom VP/KP is being proposed in the decision-making process. It is also essential to rapidly initiate a specific osteoporosis therapy when a VF occurs (ideally a bone anabolic treatment) so as to reduce the risk of fracture. Randomized controlled studies are necessary in order to better define the profile of patients who likely benefit the most from VP/KP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Gastroesophageal reflux and progressive esophageal dilatation can develop after gastric banding (GB). HYPOTHESIS: Gastric banding may interfere with esophageal motility, enhance reflux, or promote esophageal dilatation. DESIGN: Before-after trial in patients undergoing GB. SETTING: University teaching hospital. PATIENTS AND METHODS: Between January 1999 and August 2002, 43 patients undergoing laparoscopic GB for morbid obesity underwent upper gastrointestinal endoscopy, 24-hour pH monitoring, and stationary esophageal manometry before GB and between 6 and 18 months postoperatively. MAIN OUTCOME MEASURES: Reflux symptoms, endoscopic esophagitis, pressures measured at manometry, esophageal acid exposure. RESULTS: There was no difference in the prevalence of reflux symptoms or esophagitis before and after GB. The lower esophageal sphincter was unaffected by surgery, but contractions in the lower esophagus weakened after GB, in correlation with preoperative values. There was a trend toward more postoperative nonspecific motility disorders. Esophageal acid exposure tended to decrease after GB, with fewer reflux episodes. A few patients developed massive postoperative reflux. There was no clear correlation between preoperative testing and postoperative esophageal acid exposure, although patients with abnormal preoperative acid exposure tended to maintain high values after GB. CONCLUSIONS: Postoperative esophageal dysmotility and gastroesophageal reflux are not uncommon after GB. Preoperative testing should be done routinely. Low amplitude of contraction in the lower esophagus and increased esophageal acid exposure should be regarded as contraindications to GB. Patients with such findings should be offered an alternative procedure, such as Roux-en-Y gastric bypass.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Spondylo-megaepiphyseal-metaphyseal dysplasia (SMMD; OMIM 613330) is a dysostosis/dysplasia caused by recessive mutations in the homeobox-containing gene, NKX3-2 (formerly known as BAPX1). Because of the rarity of the condition, its diagnostic features and natural course are not well known. We describe clinical and radiographic findings in six patients (five of which with homozygous mutations in the NKX3-2 gene) and highlight the unusual and severe changes in the cervical spine and the neurologic complications. In individuals with SMMD, the trunk and the neck are short, while the limbs, fingers and toes are disproportionately long. Radiographs show a severe ossification delay of the vertebral bodies with sagittal and coronal clefts, missing ossification of the pubic bones, large round "balloon-like" epiphyses of the long bones, and presence of multiple pseudoepiphyses at all metacarpals and phalanges. Reduced or absent ossification of the cervical vertebrae leads to cervical instability with anterior or posterior kinking of the cervical spine (swan neck-like deformity, kyknodysostosis). As a result of the cervical spine instability or deformation, five of six patients in our series suffered cervical cord injury that manifested clinically as limb spasticity. Although the number of individuals observed is small, the high incidence of cervical spine deformation in SMMD is unique among skeletal dysplasias. Early diagnosis of SMMD by recognition of the radiographic pattern might prevent of the neurologic complications via prophylactic cervical spine stabilization. © 2012 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Several parameters of cardiovascular physiology and pathophysiology exhibit circadian rhythms. Recently, a relation between infarct size and the time of day at which it occurs has been suggested in experimental models of myocardial infarction. The aim of this study is to investigate whether circadian rhythms could cause differences in ischemic burden in patients with ST-elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention (PPCI).¦METHODS: In 353 consecutive patients with STEMI treated by PPCI, time of symptom onset, peak creatine kinase (CK), and follow-up at 30 days were obtained. We divided 24 hours into 4 time groups based on time of symptom onset (00:00-05:59, 06:00-11:59, 12:00-17:59, and 18:00-23:59).¦RESULTS: There was no difference between the groups regarding baseline patients and management's characteristics. At multivariable analysis, there was a statistically significant difference between peak CK levels among patients with symptom onset between 00:00 and 05:59 when compared with peak CK levels of patients with symptom onset in any other time group (mean increase 38.4%, P < .05). Thirty-day mortality for STEMI patients with symptom onset occurring between 00:00 and 05:59 was significantly higher than any other time group (P < .05).¦CONCLUSION: This study demonstrates an independent correlation between the infarct size of STEMI patients treated by PPCI and the time of the day at which symptoms occurred. These results suggest that time of the day should be a critical issue to look at when assessing prognosis of patients with myocardial infarction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: The study aimed to evaluate the feasibility of off-pump transapical mitral valve-in-ring implantation and to test the performance of a custom-made self-expandable stent valve, in comparison with the standard SAPIEN valve. METHODS: Acute experiments were performed in five pigs. Animals (mean weight 58.4 ± 7.3 kg) underwent mitral valve annuloplasties under cardiopulmonary bypass using 26-mm rings (SJM?). Then, a 30-mm custom-made self-expandable stent valve or a 23-mm balloon-expandable transcatheter heart valve (Edwards SAPIEN XT?) was deployed within the annuloplasty rings through a transatrial access and under direct vision. Subsequently, the stent valves were inserted transapically under fluoroscopic guidance and off pump. RESULTS: The procedural success of transatrial and transapical mitral valve-in-ring procedures was 100% (10 of 10). Mean transatrial and transapical procedure time was 2.0 ± 1.1 and 22.0 ± 5.7 min, respectively. Haemodynamic status during transapical implantation remained stable, and differences in data collected before and after the stent-valve deployment were not statistically significant. Mean mitral annulus diameter and mean mitral orifice area in the group of self-expandable stent valves were 2.60 ± 0.02 cm and 4.16 ± 0.48 cm(2), respectively, whereas in the SAPIEN group they were 1.95 ± 0.18 cm and 2.26 ± 0.20 cm(2), respectively. Trace or mild regurgitation was detected only in the self-expandable stent-valve group. Mean gradients were 4.1 ± 4.5 mmHg across the self-expandable stent valves and 1.0 ± 0 mmHg across the SAPIEN valves. Postmortem examination confirmed adequate positioning of the self-expandable valves and the SAPIEN valves within the annuloplasty ring. CONCLUSIONS: Off-pump transapical mitral valve-in-ring implantation is safe and feasible. Transapical access may represent the ideal option for valve-in-ring procedures in cases of recurrent mitral regurgitation after mitral valve repair, in high-risk patients. Owing to the supra-annular profile of the valve components, our custom-made nitinol stent valve provides nearer to normal functional area than the SAPIEN valve.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Treatment of congenital diaphragmatic hernia (CDH) challenges obstetricians, pediatric surgeons, and neonatologists. Persistent pulmonary hypertension (PPHT) associated with lung hypoplasia in CDH leads to a high mortality rate at birth. PPHT is principally due to an increased muscularization of the arterioles. Management of CDH has been greatly improved by the introduction of prenatal surgical intervention with tracheal obstruction (TO) and by more appropriate postnatal care. TO appears to accelerate fetal lung growth and to increase the number of capillary vessels and alveoli. Improvement of postnatal care over the last years is mainly due to the avoidance of lung injury by applying low peak inflation pressure during ventilation. The benefits of other drugs or technical improvements such as the use of inhaled nitric oxide or extracorporeal membrane oxygenation (ECMO) are still being debated and no single strategy is accepted worldwide. Despite intensive clinical and experimental research, the treatment of newborn with CDH remains difficult.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Symptomatic gastroduodenal manifestations of Crohn's disease (CD) are rare, with less than 4% of patients being clinically symptomatic. Gastroduodenal involvement may, however, be found endoscopically in 20% and in up to 40% of cases histologically, most frequently as Helicobacter pylori-negative focal gastritis, usually in patients with concomitant distal ileal disease. In practice, the activity of concomitant distal CD usually determines the indication for therapy, except in the presence of obstructive gastroduodenal symptoms. With the few data available, it seems correct to say that localized gastroduodenal disease should be treated with standard medical therapy used for more distal disease, with the exception of sulfasalazine and mesalanine with pH-dependent release. Presence of symptoms of obstruction needs aggressive therapy. If medical therapy with steroids and immunomodulatory drugs does not alleviate the symptoms, balloon dilation and surgery are the options to consider.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report on a patient with Marfan syndrome who presented a Stanford type B dissection of the descending thoracic aorta in late pregnancy. After a cesarean section, the patient presented a severe obstruction of the mesenteric superior artery. An endovascular fenestration was performed (balloon and guidewire based fenestration). Computed tomography (CT) angiography revealed an intussusception 'like' image of the abdominal aortic layers as a consequence of the fenestration procedure. Because of aneurismal progression in the abdominal aorta, surgical repair of the abdominal aorta and intussusception material removal was achieved six weeks later. The patient is currently in good condition. We conclude that the intussusception could be induced by a guidewire. This fenestration procedure is not recommended in patients with structural aortic disorders.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: The arteries of bifurcation aneurysms are sometimes so angulated or tortuous that an exchange maneuver is necessary to catheterize them with a balloon or stent delivery catheter. Because of the risk of distal wire perforation associated with exchange maneuvers, we sought to find an alternative technique. METHODS: Our experience shows that a microcatheter tends to preferentially follow a previously placed microcatheter, even if the initial catheterization might be challenging. Accessing an artery with two microcatheters simultaneously may thus be an alternative to an exchange maneuver. Because of this tendency for catheters to behave like sheep following one another, we named this method the sheeping technique (ST). The ST consists of (a) first placing a 1.7 French microcatheter into the division branch requiring balloon or stent protection to straighten the course of the arteries in order to facilitate and (b) positioning in the same artery of a larger and stiffer balloon or stent microcatheter. Once the second balloon or stent microcatheter is in place, the first microcatheter can be pulled back and used to coil the aneurysm. RESULTS: Between January 2009 and December 2012, The ST was successfully used in 208/246 procedures (85 %). Conversion to an exchange maneuver was necessary in 38/246 (15 %). There were no arterial perforations or ischemic events related to the handling of both microcatheters. CONCLUSION: The sheeping technique may improve safety by replacing the need for an exchange maneuver during difficult balloon- or stent-assisted coiling.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Patients with stenosed biologic pulmonary conduits require redo cardiac surgery to prevent severe right ventricular dysfunction. Following the latest trends, the trans-catheter pulmonary stent-valve implantation represents a new fascinating alternative carrying a lower operative risk, compared with the standard open-heart re-intervention. Traditionally, the pulmonary stent valve is positioned off pump, under fluoroscopic control, and requires angiographies. However, alternative tools not requiring contrast injections for the intra-operative cardiac imaging have to be also considered strongly. The usefulness of intravascular ultrasound for the positioning of aortic endoprosthesis has already been proven in previous reports and, following the same principle, we have started to routinely implant balloon-expandable stent valves (Edwards Sapien? THV) in stenosed pulmonary valve conduits using intravascular ultrasound for the stent-valve positioning without angiography. We describe the intra-operative intravascular imaging technique with technical details.