811 resultados para Autogenous grinding


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two isomorphous submicron sized metal-organic network compounds, Y-2(PDA)(3)(H2O)1]center dot 2H(2)O (PDA = 1,4-phenylenediacetate), 1 and Y1.8Tb0.2(PDA)(3)(H2O)1]center dot 2H(2)O, Tb@1 have been synthesized by employing solvent assisted liquid grinding followed by heating at 180 degrees C for 1' min and washing with water. Single crystal X-ray data of bulk 1 confirmed a three dimensional porous structure. The structure and morphology of 1 and Tb@1 were systematically characterized by PXRD, TGA, DSC, IR, SEM and EDX analysis. Dehydrated Tb@1 Tb@1'] shows a high intense visible green emission upon exposure to UV light. The green emission of Tb@1' was used for the detection of nitro explosives, such as 2,4,6-trinitrophenol (TNP), 1,3-dinitro benzene (DNB), 2,4-dinitro toluene (DNT), nitro benzene (NB), and 4-nitro toluene (NT) in acetonitrile. The results show that the emission intensity of dehydrated Tb@1' can be quenched by all the nitro analytes used in the present work. Remarkably, Tb@1' exhibited a high efficiency for TNP, DNB and DNT detection with K-SV K-SV = quenching constant based on linear Stern-Volmer plot] values of 70 920, 44 000 and 35 430 M-1, respectively, which are the highest values amongst known metal-organic materials. Using this material submicromolar level (equivalent to 0.18 ppm), a detection of nitro explosives has been achieved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Surface texture influences friction during sliding contact conditions. In the present investigation, the effect of surface texture and roughness of softer and harder counter materials on friction during sliding was analyzed using an inclined scratch testing system. In the experiments, two test configurations, namely (a) steel balls against aluminum alloy flats of different surface textures and (b) aluminum alloy pins against steel flats of different surface textures, are utilized. The surface textures were classified into unidirectionally ground, 8-ground, and randomly polished. For a given texture, the roughness of the flat surfaces was varied using grinding or polishing methods. Optical profilometer and scanning electron microscope were used to characterize the contact surfaces before and after the experiments. Experimental results showed that the surface textures of both harder and softer materials are important in controlling the frictional behavior. The softer material surface textures showed larger variations in friction between ground and polished surfaces. However, the harder material surface textures demonstrated a better control over friction among the ground surfaces. Although the effect of roughness on friction was less significant when compared to textures, the harder material roughness showed better correlations when compared to the softer material roughness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Milling is an energy intensive process and it is considered as one of the most energy inefficient processes. Electrical and mechanical shock loading can be used to develop a pre-treatment methodology to enhance energy efficiency of comminution and liberation of minerals. Coal and Banded Hematite Jasper (BHJ) Iron ores samples were taken for the study to know the effect of shock loading. These samples were exposed to 5 electric shocks of 300 kV using an electric shock loading device. A diaphragmless shock tube was used to produce 3 and 6 compressed air shocks of Mach number 2.12 to treat the coal and Iron ore samples. Microscopic, comminution and liberation studies were carried out to compare the effectiveness of these approaches. It was found that electric shock loading can comminute the coal samples more effectively and increases the yield of carbon by 40% at 1.6 gm/cc density over the untreated coal samples. Mechanical shock loading showed improved milling performance for both the materials and 12.90% and 8.1% reduction in the D-80 of the particles was observed during grinding for treated samples of coal and iron, respectively. Liberation of minerals in BHJ Iron ore was found unaffected due to low intensity of the mechanical shock waves and non conductivity of minerals. Compressed air based shock loading is easier to operate than electrical shock loading and it needs to be explored further to improve the energy efficacy of comminution. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Crystals of voriconazole, an antifungal drug, are soft in nature, and this is disadvantageous during compaction studies where pressure is applied on the solid. Crystal engineering is used to make cocrystals and salts with modified mechanical properties (e.g., hardness). Cocrystals with biologically safe coformers such as fumaric acid, 4-hydroxybenzoic acid, and 4-aminobenzoic acid and salts with hydrochloric acid and oxalic acid are prepared through solvent assisted grinding. The presence (salt) or absence (cocrystal) of proton transfer in these multicomponent crystals is unambiguously confirmed with single crystal X-ray diffraction. All the cocrystals have 1:1 stoichiometry, whereas salts exhibit variable stoichiometries such as HCl salt (1:2) and oxalate salts (1:1.5 and 1:1). The nanoindentation technique was applied on single crystals of the salts and cocrystals. The salts exhibit better hardness than the drug and cocrystals in the order salts drug cocrystals. The molecular origin of this mechanical modulation is explained on the basis of slip planes in the crystal structure and relative orientations of the molecules with respect to the nanoindentation direction. The hydrochloride salt is the hardest solid in this family. This may be useful for tableting of the drug during formulation and in drug development.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Co3O4 and Co3O4/MWCNTs were prepared by hydrothermal process under autogenous pressure in Teflon lined autoclave and calcined at 250 degrees C. Both samples were characterized by PXRD, FT-IR, SEM-EDS, TEM & FT-Raman to evaluate their surface and bulk properties. The PXRD pattern of the materials indicated the formation of cubic phase of Co3O4. FT-IR results showed the presence of metal oxygen bond in the samples. The SEM and TEM images of the Co3O4 / MWCNTs indicated spherical and cubic aggregates of metal oxide particles (10-30 nm) decorated both on the surface and inside the tubes of carbon nanotubes. The characteristic Ig and Id (graphitic and defects) Raman bands indicated the retention of tubular structure of MWCNTs even after the deposition of Co3O4. The calcined Co3O4-MWCNTs composites and Co3O4 exhibited specific capacitance of 284 & 205 F/g at a sweep rate of 2mVs(-1) in 6M KOH by cyclic voltammetry. The psuedocapacitance performances of calcined Co3O4-MWCNTs were found to be better than Co3O4. Chronopotentiometric studies made for the materials at a current density of 500mA/g indicated 100% columbic efficiency at 2000th cycle for Co3O4/ MWCNTs which is a better electrode material than Co3O4.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hydrochlorothiazide (HCT) is a diuretic and a BCS class IV drug with low solubility and low permeability, exhibiting poor oral absorption. The present study attempts to improve the physicochemical properties of the drug using a crystal engineering approach with cocrystals. Such multicomponent crystals of HCT with nicotinic acid (NIC), nicotinamide (NCT), 4-aminobenzoic acid (PABA), succinamide (SAM), and resorcinol (RES) were prepared using liquid-assisted grinding, and their solubilities in pH 7.4 buffer were evaluated. Diffusion and membrane permeability were studied using a Franz diffusion cell. Except for the SAM and NIC cocrystals, all other binary systems exhibited improved solubility. All of the cocrystals showed improved diffusion/membrane permeability compared to that of HCT with the exception of the SAM cocrystal. When the solubility was high, as in the case of PABA, NCT, and RES cocrystals, the flux/permeability dropped slightly. This is in agreement with the expected interplay between solubility and permeability. Improved solubility/permeability is attributed to new drug-coformer interactions. Cocrystals of SAM, however, showed poor solubility and flux This cocrystal contains a primary sulfonamide dimer synthon similar to that of HCT polymorphs, which may be a reason for its unusual behavior. Hirshfeld surface analysis was carried out in all cases to determine whether a correlation exists between cocrystal permeability and drug-coformer interactions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work attempts to bring critical insights into the electromagnetic shielding efficiency in polymeric nanocomposites with respect to the particle size of magnetic nanoparticles added along with or without a conductive inclusion. To gain insight, various Ni-Fe (NixFe1-x; x = 10, 20, 40; Ni: nickel, Fe: iron) alloys were prepared by a vacuum arc melting process and different particle sizes were then achieved by a controlled grinding process for different time scales. Poly(vinylidene fluoride), PVDF based composites involving different particle sizes of the Ni-Fe alloy were prepared with or without multiwall carbon nanotubes (MWNTs) by a wet grinding approach. The Ni-Fe particles were thoroughly characterized with respect to their microstructure and magnetization; and the electromagnetic (EM) shielding efficiency (SE) of the resulting composites was obtained from the scattering parameters using a vector network analyzer in a broad range of frequencies. The saturation magnetization of Ni-Fe nanoparticles and the bulk electrical conductivity of PVDF/Ni-Fe composites scaled with increasing particle size of NiFe. Interestingly, the PVDF/Ni-Fe/MWNT composites showed a different trend where the bulk electrical conductivity and SE scaled with decreasing particle size of the Ni-Fe alloy. A total SE of similar to 35 dB was achieved with 50 wt% of Ni60Fe40 and 3 wt% MWNTs. More interestingly, the PVDF/Ni-Fe composites shielded the EM waves mostly by reflection whereas, the PVDF/Ni-Fe/MWNT shielded mostly by absorption. A minimum reflection loss of similar to 58 dB was achieved in the PVDF/Ni-Fe/MWNT composites in the X-band (8-12 GHz) for a particular size of Ni-Fe alloy nanoparticles. This study brings new insights into the EM shielding efficiency in PVDF/magnetic nanoparticle based composites in the presence and absence of conducting inclusion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Experimental trials of autogenous deep penetration welding between dissimilar cast Ni-based superalloy K418 and alloy steel 42CrMo flat plates with 5.0 mm thickness were conducted using a 3 kW continuous wave (CW) Nd:YAG laser. The influences of laser output power, welding velocity and defocusing distance on the morphology, welding depth and width as well as quality of the welded seam were investigated. Results show that full keyhole welding is not formed on both K4.18 and 42CrMo side, simultaneously, due to the relatively low output power. Partial fusion is observed on the welded seam near 42CrMo side because of the large disparity of thermal-physical and high-temperature mechanical properties of these two materials. Tile rnicrohardness of the laser-welded joint was also examined and analyzed. It is suggested that applying negative defocusing in the range of Raylei length can increase the welding depth and improve tile coupling efficiency of the laser materials interaction. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For fully three decades there has been an almost steady decline in Maryland's oyster production... are alarmed for its future. Reasons for decline, data supplied,importance of brood oysters and clutch replenishment. Problems of warm weather and bacterial activity as well as tongs grinding the bottom. Conflicts in canning of early season oysters and late season crops like tomatoes. (PDF contains 16 pages)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Techniques are described for preparing acetate peels of sectioned valves of ocean quahogs, Arctica islandica, for age determinations. The respective sequence of preparation begins by sectioning left valves oriented to include a single hinge tooth, bleaching to remove the heavy periostracum, embedding the valves in an epoxy resin, grinding and polishing the embedments to a high luster, etching the exposed cut valve surfaces, and applying sheet acetate with acetone. Annuli are clearly defined relative to growth increments in the peel preparations for all sizes and ages of ocean quahogs. (PDF file contains12 pages.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objeto de estudo foi o preparo e a administração de medicamentos por cateter pela enfermagem em pacientes que recebem nutrição enteral. O objetivo geral foi investigar o padrão de preparo e administração dos medicamentos por cateter em pacientes que recebem nutrição enteral concomitante. Os objetivos específicos foram apresentar o perfil dos medicamentos preparados e administrados de acordo com a possibilidade de serem administrados por cateter enteral e avaliar o tipo e a freqüência de erros que ocorrem no preparo e administração de medicamentos por cateter. Tratou-se de uma pesquisa com desenho transversal de natureza observacional, sem modelo de intervenção. Foi desenvolvida em um hospital do Rio de Janeiro onde foram observados técnicos de enfermagem preparando e administrando medicamentos por cateter na Unidade de Terapia Intensiva. Foram observadas 350 doses de medicamentos sendo preparados e administrados. Os grupos de medicamentos prevalentes foram os que agem no Sistema Cardiovascular Renal com 164 doses (46,80%), seguido pelos que agem no Sistema Respiratório e Sangue com 12,85% e 12,56% respectivamente. Foram encontrados 19 medicamentos diferentes do primeiro grupo, dois no segundo e cinco no terceiro. As categorias de erro no preparo foram trituração, diluição e misturas. Encontrou-se uma taxa média de 67,71% no preparo de medicamentos. Comprimidos simples foram preparados errados em 72,54% das doses, e todos os comprimidos revestidos e de liberação prolongada foram triturados indevidamente entre sólidos a categoria de erro prevalente foi trituração com 45,47%, preparar misturando medicamentos foi um erro encontrado em quase 40% das doses de medicamentos sólidos. A trituração insuficiente ocorreu em 73,33% das doses de ácido fólico, do cloridrato de amiodarona (58,97%) e bromoprida (50,00%). A mistura com outros medicamentos ocorreu em 66,66% das doses de bromoprida, de besilato de anlodipina (53,33%), bamifilina (43,47%), ácido fólico (40,00%) e ácido acetilsalicílico (33,33%). Os erros na administração foram ausência de pausa e manejo indevido do cateter. A taxa média de erros na administração foi de 32,64%, distribuídas entre 17,14% para pausa e 48,14% para manejo do cateter. A ausência de lavagem do cateter antes foi o erro mais comum e o mais incomum foi não lavar o cateter após a administração. Os medicamentos mais envolvidos em erros na administração foram: cloridrato de amiodarona (n=39), captopril (n=33), cloridrato de hidralazina (n=7), levotiroxina sódica (n=7). Com relação à lavagem dos cateteres antes, ela não ocorreu em 330 doses de medicamentos. O preparo e administração inadequados de medicamentos podem levar à perdas na biodisponibilidade, diminuição do nível sérico e riscos de intoxicações para o paciente. Preparar e administrar medicamentos são procedimentos comuns, porém apresentou altas taxas de erros, o que talvez reflita pouco conhecimento desses profissionais sobre as boas práticas da terapia medicamentosa. Constata-se a necessidade de maior investimento de todos os profissionais envolvidos, médicos, enfermeiros e farmacêuticos nas questões que envolvam a segurança com medicamentos assim como repensar o processo de trabalho da enfermagem.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os aços inoxidáveis do tipo duplex possuem grande importância na indústria, principalmente na do petróleo e gás natural, por apresentarem elevada resistência mecânica e excelente resistência à corrosão. Caracterizam-se por apresentar estrutura bifásica, constituída de proporções praticamente iguais de ferrita e austenita. O presente trabalho caracterizou juntas soldadas por TIG autógeno de aço inoxidável duplex UNS S32760. Foram confeccionados quatro grupos de amostras, provenientes da variação da corrente de soldagem e consequentemente do aporte térmico (corrente de pico: 25A e 40A - aporte térmico: 0,12KJ/mm e 0,19KJ/mm) e da composição do gás de proteção (argônio puro ou argônio contendo 2,5% nitrogênio). Foram utilizadas técnicas de caracterização por metalografia colorida, análise e processamento digital de imagens, ensaios de microdureza Vickers. Para avaliar a resistência à corrosão foram realizados ensaios de potencial em circuito aberto com solução de cloreto férrico (FeCl3) e eletrodo de referência de calomelano saturado. A análise quantitativa das fases ferrita e austenita presentes nas juntas soldadas mostrou que a adição de nitrogênio no gás de proteção favoreceu a formação da fase austenita, variando de 11% (sem nitrogênio) para 26% (com nitrogênio) a quantidade desta fase. Em uma análise qualitativa a variação do aporte térmico: 0,12KJ/mm para 0,19KJ/mm resultou no aumento do tamanho de grãos da fase ferrita.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[ES]Este trabajo pretende analizar la influencia que tiene la longitud de corte elegida y el filtro empleado en la medida de la rugosidad. Se realizan medidas de rugosidad en tres probetas que han sido sometidas a diferentes procesos de fabricación (fresado, rectificado y electroerosión). Además, se utilizan tres instrumentos diferentes para la medición. Tras realizar las medidas, se comparan los resultados y se extraen las conclusiones

Relevância:

10.00% 10.00%

Publicador:

Resumo:

散粒磨料研磨与固着磨料研磨是光学研磨加工过程中的两种主要手段,但两者材料去除的机制不同。目前针对高功率固体激光装置中的主要工作物质——磷酸盐激光钕玻璃的亚表面缺陷(SSD)研究相对较少,因此在实验的基础上,通过系统地研究固着磨料对磷酸盐激光钕玻璃的研磨工艺过程,分析了多种因素,如磨料粒径、载荷大小、机床转速,以及结合剂材料与冷却液等对钕玻璃亚表面缺陷形成的影响,并与散粒磨料研磨工艺所产生的亚表面缺陷进行了比较,对关键工艺参数进行定量,为高质量钕玻璃制造工艺的选型以及进一步优化亚表面缺陷提供了重要的参考数据。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a destructive method for detecting and measuring subsurface damage of Nd-doped phosphate glasses. An instrument based on the dimple method - a destructive method - was developed. Subsurface damage depth produced in each fabrication procedure was obtained. We extend the surface roughness-subsurface damage relation to Nd-doped phosphate glasses. The constant ratio of subsurface damage and surface roughness was obtained as well. We also analyse the relation of abrasive size and subsurface damage experimentally. From a measurement of the surface roughness or abrasive size, one can obtain an accurate estimate of the damage layer thickness that must be eliminated by polishing or subsequent grinding operations. (C) 2007 Elsevier GmbH. All rights reserved.