971 resultados para Air pollution management
Resumo:
Best management practices in green lodging are sustainable or “green” business strategies designed to enhance the lodging product from the perspective of owners, operators and guests. For guests, these practices should enhance their experience while for owners and operators, generate positive returns on investments. Best management practices in green lodging typically starts with a clear understanding of each lodging firm’s role in society, its impact on the environment and strategies developed to mitigate negative environmental externalities generated from the production of lodging goods and services. Negative externalities of hotel operations manifest themselves in energy and water usage, waste generation and air pollution. Hence, best management practices in green lodging are dynamic, cost effective, innovative, stakeholder driven and environmentally sound technical and behavioral solutions that attempt to ameliorate or eliminate the negative environmental externalities associated with lodging operations, while simultaneously generate positive returns on green investments. Thus, best management practices in green lodging should reduce lodging firms’ operating costs, increase guest satisfaction, reduce or eliminate the negative environmental impacts associated with hotel operations while simultaneously enhance business operations.
Resumo:
Best management practices in green lodging are sustainable or “green” business strategies designed to enhance the lodging product from the perspective of owners, operators and guests. For guests, these practices should enhance their experience while for owners and operators, generate positive returns on investments. Best management practices in green lodging typically starts with a clear understanding of each lodging firm’s role in society, its impact on the environment and strategies developed to mitigate negative environmental externalities generated from the production of lodging goods and services. Negative externalities of hotel operations manifest themselves in energy and water usage, waste generation and air pollution. Hence, best management practices in green lodging are dynamic, cost effective, innovative, stakeholder driven and environmentally sound technical and behavioral solutions that attempt to ameliorate or eliminate the negative environmental externalities associated with lodging operations, while simultaneously generate positive returns on green investments. Thus, best management practices in green lodging should reduce lodging firms’ operating costs, increase guest satisfaction, reduce or eliminate the negative environmental impacts associated with hotel operations while simultaneously enhance business operations.
Resumo:
Twenty one sampling locations were assessed for carbon monoxide (CO), carbondioxide (CO2), oxygen (O2), sulphur dioxide (SO2), nitrogen dioxide (NO2), nitrogen oxide (NO), suspended particulate matter (SPM) and noise level using air pollutants measurement methods approved by ASTM for each specific parameter. All equipments and meters were all properly pre-calibrated before each usage for quality assurance. Findings of the study showed that measured levels of noise (61.4 - 101.4 dBA), NO (0.0 - 3.0 ppm), NO2 (0.0 - 3.0 ppm), CO (1.0 – 42.0 ppm) and SPM (0.14 – 4.82 ppm) in all sampling areas were quite high and above regulatory limits however there was no significant difference except in SPM (at all the sampling points), and noise, NO2 and NO (only in major traffic intersection). Air quality index (AQI) indicates that the ambient air can be described as poor for SPM, varied from good to very poor for CO, while NO and NO2 are very good except at major traffic intersection where they were both poor and very poor (D-E). The results suggest that strict and appropriate vehicle emission management, industrial air pollution control coupled with close burning management of wastes should be considered in the study area to reduce the risks associated with these pollutants.
Resumo:
Nowadays, the spreading of the air pollution crisis enhanced by greenhouse gases emission is leading to the worsening of the global warming. In this context, the transportation sector plays a vital role, since it is responsible for a large part of carbon dioxide production. In order to address these issues, the present thesis deals with the development of advanced control strategies for the energy efficiency optimization of plug-in hybrid electric vehicles (PHEVs), supported by the prediction of future working conditions of the powertrain. In particular, a Dynamic Programming algorithm has been developed for the combined optimization of vehicle energy and battery thermal management. At this aim, the battery temperature and the battery cooling circuit control signal have been considered as an additional state and control variables, respectively. Moreover, an adaptive equivalent consumption minimization strategy (A-ECMS) has been modified to handle zero-emission zones, where engine propulsion is not allowed. Navigation data represent an essential element in the achievement of these tasks. With this aim, a novel simulation and testing environment has been developed during the PhD research activity, as an effective tool to retrieve routing information from map service providers via vehicle-to-everything connectivity. Comparisons between the developed and the reference strategies are made, as well, in order to assess their impact on the vehicle energy consumption. All the activities presented in this doctoral dissertation have been carried out at the Green Mobility Research Lab} (GMRL), a research center resulting from the partnership between the University of Bologna and FEV Italia s.r.l., which represents the industrial partner of the research project.
Resumo:
In the last decades, the air traffic system has been changing to adapt itself to new social demands, mainly the safe growth of worldwide traffic capacity. Those changes are ruled by the Communication, Navigation, Surveillance/Air Traffic Management (CNS/ATM) paradigm, based on digital communication technologies (mainly satellites) as a way of improving communication, surveillance, navigation and air traffic management services. However, CNS/ATM poses new challenges and needs, mainly related to the safety assessment process. In face of these new challenges, and considering the main characteristics of the CNS/ATM, a methodology is proposed at this work by combining ""absolute"" and ""relative"" safety assessment methods adopted by the International Civil Aviation Organization (ICAO) in ICAO Doc.9689 [14], using Fluid Stochastic Petri Nets (FSPN) as the modeling formalism, and compares the safety metrics estimated from the simulation of both the proposed (in analysis) and the legacy system models. To demonstrate its usefulness, the proposed methodology was applied to the ""Automatic Dependent Surveillance-Broadcasting"" (ADS-B) based air traffic control system. As conclusions, the proposed methodology assured to assess CNS/ATM system safety properties, in which FSPN formalism provides important modeling capabilities, and discrete event simulation allowing the estimation of the desired safety metric. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Low-density lipoprotein oxidation is implicated in the development of atherosclerosis. Plasma susceptibility to oxidation may be used as a marker of low-density lipoprotein oxidation and thus predict atherosclerotic risk. In this study the authors investigated the relationship between plasma susceptibility to oxidation and exposure to automotive pollution in a group of automobile mechanics (n = 16) exposed to high levels of automotive pollution, vs. matched controls (n = 13). The authors induced plasma oxidation by a free radical initiator and they determined susceptibility to oxidation by (1) change in absorbance at 234 nm, (2) lag time to conjugated diene formation, and (3) linear slope of the oxidation curve. Mechanics had significantly higher values (mean standard error) for change in absorbance (1.60 +/- 0.05 vs. 1.36 +/- 0.05; p < .002), and slope (1.6 x 10(-3) +/- 0.1 x 10(-3) vs. 1.3 x 10(-3) +/- 0.1 x 10(-3); p < .001), compared with controls. These results indicate that regular exposure to automotive pollutants increases plasma susceptibility to oxidation and may, in the long term, increase the risk of developing atherosclerosis.
Resumo:
A descriptive study was developed to monitor air fungal contamination in two elementary schools in Lisbon, Portugal. Eight air samples of 250 litres through impaction method were collected in canteen, library, classrooms and also, outside premises as reference place. Simultaneously, were also monitored environmental parameters, including temperature, and humidity through the equipment Babouc, LSI Sistems and according to the International Standard ISO 7726 - 1998. Considering both schools, sixteen different species of fungi in air were identified, being the 2 most commonly isolated Cladosporium sp. (51,1%) and Penicillium sp. (27,5%). Besides these genera Trichoderma, Aspergillus, Alternaria, Chrysonilia, Botritys, Ulocladium, Athrium, Aureobasidium, Phoma, Scedosporium e Geotrichum were also isolated. Regarding yeasts, Candida sp., Cryptococcus sp. and Rhodotorula sp. were isolated. The youngest school, as well canteens in each school, presented the worst results concerning the air fungal contamination, maybe due to the higher number of occupants. There was no significant relationship (p>0,05) between fungal contamination and temperature and humidity.
Resumo:
Formaldehyde was the first air pollutant, which already in the 1970s emerged as a specifically non-industrial indoor air quality problem. Yet formaldehyde remained an indoor air quality issue and the formaldehyde level in residential indoor air is among the highest of any indoor air contaminant. Formaldehyde concentrations in 4 different indoor settings (schools, office buildings, new dwellings and occupied dwellings) in Portugal were measured using Photo Ionization Detection (PID) equipment (11,7 eV lamps). All the settings presented results higher than the reference value proposed by Portuguese legislation. Furthermore, occupied dwellings showed 3 units with results above the reference. We could conclude that formaldehyde presence is a reality in monitored indoor settings. Concentration levels are higher than the Portuguese reference value for indoor settings and these can indicate health problems for occupants.
Resumo:
Clean air is a basic requirement of life. The Indoor Air Quality (IAQ) has been the object of several studies due to an increasing concern within the scientific community on the effects of indoor air quality upon health, especially as people tend to spend more time indoors than outdoors. The quality of air inside homes, offices, schools or other private and public buildings is an essential determinant of healthy life and people’s well-being. People can be exposed to contaminants by inhalation, ingestion and dermal contact. In the past, scientists have paid much attention to the study of exposure to outdoor air contaminants, because they have realised the seriousness of outdoor air pollution problems. However, each indoor microenvironment has unique characteristics, determined by the local outdoor air, specific building characteristics and indoor activities. Indeed, hazardous substances are emitted from buildings, construction materials and indoor equipment or due to human activities indoors.
Resumo:
A descriptive study was developed in order to assess air contamination caused by fungi and particles in seven poultry units. Twenty seven air samples of 25 litters were collected through impaction method. Air sampling and particle concentration measurement were performed in the pavilions’ interior and also outside premises, since this was the place regarded as reference. Simultaneously, temperature and relative humidity were also registered. Regarding fungal load in the air from the seven poultry farms, the highest value obtained was 24040 CFU/m3 and the lowest was 320 CFU/m3. Twenty eight species/genera of fungi were identified, being Scopulariopsis brevicaulis (39.0%) the most commonly isolated species and Rhizopus sp. (30.0%) the most commonly isolated genus. From the Aspergillus genus, Aspergillus flavus (74.5%) was the most frequently detected species. There was a significant correlation (r=0.487; p=0.014) between temperature and the level of fungal contamination (CFU/m3). Considering contamination caused by particles, in this study, particles with larger dimensions (PM5.0 and PM10) have higher concentrations. There was also a significant correlation between relative humidity and concentration of smaller particles namely, PM0.5 (r=0.438; p=0.025) and PM1.0 (r=0.537; p=0.005). Characterizing typical exposure levels to these contaminants in this specific occupational setting is required to allow a more detailed risk assessment analysis and to set exposure limits to protect workers’ health.
Resumo:
Throughout the world, epidemiological studies were established to examine the relationship between air pollution and mortality rates and adverse respiratory health effects. However, despite the years of discussion the correlation between adverse health effects and atmospheric pollution remains controversial, partly because these studies are frequently restricted to small and well-monitored areas. Monitoring air pollution is complex due to the large spatial and temporal variations of pollution phenomena, the high costs of recording instruments, and the low sampling density of a purely instrumental approach. Therefore, together with the traditional instrumental monitoring, bioindication techniques allow for the mapping of pollution effects over wide areas with a high sampling density. In this study, instrumental and biomonitoring techniques were integrated to support an epidemiological study that will be developed in an industrial area located in Gijon in the coastal of central Asturias, Spain. Three main objectives were proposed to (i) analyze temporal patterns of PM10 concentrations in order to apportion emissions sources, (ii) investigate spatial patterns of lichen conductivity to identify the impact of the studied industrial area in air quality, and (iii) establish relationships amongst lichen conductivity with some site-specific characteristics. Samples of the epiphytic lichen Parmelia sulcata were transplanted in a grid of 18 by 20 km with an industrial area in the center. Lichens were exposed for a 5-mo period starting in April 2010. After exposure, lichen samples were soaked in 18-MΩ water aimed at determination of water electrical conductivity and, consequently, lichen vitality and cell damage. A marked decreasing gradient of lichens conductivity relative to distance from the emitting sources was observed. Transplants from a sampling site proximal to the industrial area reached values 10-fold higher than levels far from it. This finding showed that lichens reacted physiologically in the polluted industrial area as evidenced by increased conductivity correlated to contamination level. The integration of temporal PM10 measurements and analysis of wind direction corroborated the importance of this industrialized region for air quality measurements and identified the relevance of traffic for the urban area.
Resumo:
The aim of this study was the assessment of exposure to ultrafine in the urban environment of Lisbon, Portugal, due to automobile traffic, and consisted of the determination of deposited alveolar surface area in an avenue leading to the town center during late spring. This study revealed differentiated patterns for weekdays and weekends, which could be related with the fluxes of automobile traffic. During a typical week, ultrafine particles alveolar deposited surface area varied between 35.0 and 89.2 mu m(2)/cm(3), which is comparable with levels reported for other towns such in Germany and the United States. These measurements were also complemented by measuring the electrical mobility diameter (varying from 18.3 to 128.3 nm) and number of particles that showed higher values than those previously reported for Madrid and Brisbane. Also, electron microscopy showed that the collected particles were composed of carbonaceous agglomerates, typical of particles emitted by the exhaustion of diesel vehicles. Implications: The approach of this study considers the measurement of surface deposited alveolar area of particles in the outdoor urban environment of Lisbon, Portugal. This type of measurements has not been done so far. Only particulate matter with aerodynamic diameters <2.5 (PM2.5) and >10 (PM10) mu m have been measured in outdoor environments and the levels found cannot be found responsible for all the observed health effects. Therefore, the exposure to nano- and ultrafine particles has not been assessed systematically, and several authors consider this as a real knowledge gap and claim for data such as these that will allow for deriving better and more comprehensive epidemiologic studies. Nanoparticle surface area monitor (NSAM) equipments are recent ones and their use has been limited to indoor atmospheres. However, as this study shows, NSAM is a very powerful tool for outdoor environments also. As most lung diseases are, in fact, related to deposition of the alveolar region of the lung, the metric used in this study is the ideal one.
Resumo:
Cooking was found to be a main source of submicrometer and ultrafine aerosols from gas combustion in stoves. Therefore, this study consisted of the determination of the alveolar deposited surface area due to aerosols resulting from common domestic cooking activities (boiling fish, vegetables, or pasta, and frying hamburgers and eggs). The concentration of ultrafine particles during the cooking events significantly increased from a baseline of 42.7 mu m(2)/cm(3) (increased to 72.9 mu m(2)/cm(3) due to gas burning) to a maximum of 890.3 mu m(2)/cm(3) measured during fish boiling in water, and a maximum of 4500 mu m(2)/cm(3) during meat frying. This clearly shows that a domestic activity such as cooking can lead to exposures as high as those of occupational exposure activities.
Resumo:
Due to their detrimental effects on human health, the scientific interest in ultrafine particles (UFP) has been increasing, but available information is far from comprehensive. Compared to the remaining population, the elderly are potentially highly susceptible to the effects of outdoor air pollution. Thus, this study aimed to (1) determine the levels of outdoor pollutants in an urban area with emphasis on UFP concentrations and (2) estimate the respective dose rates of exposure for elderly populations. UFP were continuously measured over 3 weeks at 3 sites in north Portugal: 2 urban (U1 and U2) and 1 rural used as reference (R1). Meteorological parameters and outdoor pollutants including particulate matter (PM10), ozone (O3), nitric oxide (NO), and nitrogen dioxide (NO2) were also measured. The dose rates of inhalation exposure to UFP were estimated for three different elderly age categories: 64–70, 71–80, and >81 years. Over the sampling period levels of PM10, O3 and NO2 were in compliance with European legislation. Mean UFP were 1.7 × 104 and 1.2 × 104 particles/cm3 at U1 and U2, respectively, whereas at rural site levels were 20–70% lower (mean of 1 ×104 particles/cm3). Vehicular traffic and local emissions were the predominant identified sources of UFP at urban sites. In addition, results of correlation analysis showed that UFP were meteorologically dependent. Exposure dose rates were 1.2- to 1.4-fold higher at urban than reference sites with the highest levels noted for adults at 71–80 yr, attributed mainly to higher inhalation rates.