452 resultados para Acoustics.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The present study aimed to compare elderly and young female voices in habitual and high intensity. The effect of increased intensity on the acoustic and perceptual parameters was assessed. Sound pressure level, fundamental frequency, jitter, shimmer, and harmonic to noise ratio were obtained at habitual and high intensity voice in a group of 30 elderly women and 30 young women. Perceptual assessment was also performed. Both groups demonstrated an increase in sound pressure level and fundamental frequency from habitual voice to high intensity voice. No differences were found between groups in any acoustic variables on samples recorded with habitual intensity level. No significant differences between groups were found in habitual intensity level for pitch, hoarseness, roughness, and breathiness. Asthenia and instability obtained significant higher values in elderly than young participants, whereas, the elderly demonstrated lower values for perceived tension and loudness than young subjects. Acoustic and perceptual measures do not demonstrate evident differences between elderly and young speakers in habitual intensity level. The parameters analyzed may lack the sensitivity necessary to detect differences in subjects with normal voices. Phonation with high intensity highlights differences between groups, especially in perceptual parameters. Therefore, high intensity should be included to compare elderly and young voice.
Resumo:
This paper presents an analysis of the content in acoustics present in physics textbooks recommended by PNLEM, which used the same criteria of evaluation from used by experts in the analysis of such books. In this way, we observed that such texts have evolved little in comparison with the textual presentations reviewed in 1998 and published in the journal Science and Education [1], which were analyzed ten physics textbooks for high school, among which the most commom, at the time, in Brazilian schools. Although we identified the inclusion of some aspects of the culture of sound and music, there are still several conceptual and historical distortions, besides the little importance has been given to links CTSA, among them, studies of soundscapes that, even, are mentioned.
Resumo:
The teaching of acoustics has been characterized by a banking model that little contributes to the ideal training of citizens capable of understanding and acting to improve their environment soundscapes. Equally distant from the world of sound and musical culture, audio technology and acoustic environment, it is disconnected from the ever-increasing effort to raise awareness on hearing and sound education, as defended by the Canadian educator Prof. Raymond Murray Schafer. In order to provide elements for reflection on how Mathematics can be itself a language to compete in a sound education, we developed, in a dialogical and problematizing method applied to the technological and cultural world, one further research and teaching with Math students of UNEMAT in Barra do Bugres. This study pointed to the feasibility of educating consciences capable of of improving their acoustic environment, modifying the landscapes where we live, under our responsibility.
Resumo:
1. Blue whale locations in the Southern Hemisphere and northern Indian Ocean were obtained from catches (303 239), sightings (4383 records of ≥ 8058 whales), strandings (103), Discovery marks (2191) and recoveries (95), and acoustic recordings. 2. Sighting surveys included 7 480 450 km of effort plus 14 676 days with unmeasured effort. Groups usually consisted of solitary whales (65.2%) or pairs (24.6%); larger feeding aggregations of unassociated individuals were only rarely observed. Sighting rates (groups per 1000 km from many platform types) varied by four orders of magnitude and were lowest in the waters of Brazil, South Africa, the eastern tropical Pacific, Antarctica and South Georgia; higher in the Subantarctic and Peru; and highest around Indonesia, Sri Lanka, Chile, southern Australia and south of Madagascar. 3. Blue whales avoid the oligotrophic central gyres of the Indian, Pacific and Atlantic Oceans, but are more common where phytoplankton densities are high, and where there are dynamic oceanographic processes like upwelling and frontal meandering. 4. Compared with historical catches, the Antarctic (‘true’) subspecies is exceedingly rare and usually concentrated closer to the summer pack ice. In summer they are found throughout the Antarctic; in winter they migrate to southern Africa (although recent sightings there are rare) and to other northerly locations (based on acoustics), although some overwinter in the Antarctic. 5. Pygmy blue whales are found around the Indian Ocean and from southern Australia to New Zealand. At least four groupings are evident: northern Indian Ocean, from Madagascar to the Subantarctic, Indonesia to western and southern Australia, and from New Zealand northwards to the equator. Sighting rates are typically much higher than for Antarctic blue whales.
Resumo:
The objective of this study is to investigate cardiac bioeffects resulting from ultrasonic stimulation using a specific set of acoustical parameters. Ten Sprague-Dawley rats were anesthetized and exposed to 1-MHz ultrasound pulses of 3-MPa peak rarefactional pressure and approximately 1% duty factor. The pulse repetition frequency started slightly above the heart rate and was decreased by 1 Hz every 10 s, for a total exposure duration of 30 s. The control group was composed of five rats. Two-way analysis of variance for repeated measures and Bonferroni post hoc tests were used to compare heart rate and ejection fraction, which was used as an index of myocardial contractility. It was demonstrated for the first time that transthoracic ultrasound has the potential to decrease the heart rate by similar to 20%. The negative chronotropic effect lasted for at least 15 min after ultrasound exposure and there was no apparent gross damage to the cardiac tissue.
Resumo:
Linear parameter varying (LPV) control is a model-based control technique that takes into account time-varying parameters of the plant. In the case of rotating systems supported by lubricated bearings, the dynamic characteristics of the bearings change in time as a function of the rotating speed. Hence, LPV control can tackle the problem of run-up and run-down operational conditions when dynamic characteristics of the rotating system change significantly in time due to the bearings and high vibration levels occur. In this work, the LPV control design for a flexible shaft supported by plain journal bearings is presented. The model used in the LPV control design is updated from unbalance response experimental results and dynamic coefficients for the entire range of rotating speeds are obtained by numerical optimization. Experimental implementation of the designed LPV control resulted in strong reduction of vibration amplitudes when crossing the critical speed, without affecting system behavior in sub- or supercritical speeds. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
In this work, we present a numerical study of the use of reconfigurable arrays (RCA) for vibro-acoustography (VA) beam formation. A parametric study of the aperture selection, number of channels, number of elements, focal distance, and steering parameters is presented to show the feasibility and evaluate the performance of VA imaging based on RCA. The transducer aperture was based on two concentric arrays driven by two continuous-wave or toneburst signals at slightly different frequencies. The mathematical model considers a homogeneous, isotropic, inviscid medium. The point-spread function of the system is calculated based on angular spectrum methods using the Fresnel approximation for rectangular sources. Simulations considering arrays with 50 x 50 to 200 x 200 elements with number of channels varying in the range of 32 to 128 are evaluated to identify the best configuration for VA. Advantages of two-dimensional and RCA arrays and aspects related to clinical importance of the RCA implementation in VA, such as spatial resolution, image frame rate, and commercial machine implementation, are discussed. It is concluded that RCA transducers can produce spatial resolution similar to confocal transducers and steering is possible in the elevational and azimuthal planes. Optimal settings for number of elements, number of channels, maximum steering, and focal distance are suggested for VA clinical applications. Furthermore, an optimization for beam steering based on the channel assignment is proposed for balancing the contribution of the two waves in the steered focus.
Resumo:
Intravascular ultrasound (IVUS) phantoms are important to calibrate and evaluate many IVUS imaging processing tasks. However, phantom generation is never the primary focus of related works; hence, it cannot be well covered, and is usually based on more than one platform, which may not be accessible to investigators. Therefore, we present a framework for creating representative IVUS phantoms, for different intraluminal pressures, based on the finite element method and Field II. First, a coronary cross-section model is selected. Second, the coronary regions are identified to apply the properties. Third, the corresponding mesh is generated. Fourth, the intraluminal force is applied and the deformation computed. Finally, the speckle noise is incorporated. The framework was tested taking into account IVUS contrast, noise and strains. The outcomes are in line with related studies and expected values. Moreover, the framework toolbox is freely accessible and fully implemented in a single platform. (E-mail: fernando.okara@gmail.com) (c) 2012 World Federation for Ultrasound in Medicine & Biology.
Resumo:
Objective: An experimental in vitro study was carried out to evaluate the influence of cortical bone thickness on ultrasound propagation velocity. Methods: Sixty bone plates were used, made from bovine femurs, with thickness ranging from 1 to 6 mm (10 of each). The ultrasound velocity measurements were performed using a device specially designed for this purpose, in an underwater acoustic tank and with direct contact using contact gel. The transducers were positioned in two ways: on opposite sides, with the bone between them, for the transverse measurement; and parallel to each other, on the same side of the bone plates, for the axial measurements. Results: In the axial transmission mode, the ultrasound velocity speed increased with cortical bone thickness, regardless of the distance between the transducers, up to a thickness of 5 mm, then remained constant thereafter. There were no changes in velocity when the transverse measures were made. Conclusion: Ultrasound velocity increased with cortical bone thickness in the axial transmission mode, until the thickness surpasses the wavelength, after which point it remained constant. Level of Evidence: Experimental Study.
Resumo:
Mach number and thermal effects on the mechanisms of sound generation and propagation are investigated in spatially evolving two-dimensional isothermal and non-isothermal mixing layers at Mach number ranging from 0.2 to 0.4 and Reynolds number of 400. A characteristic-based formulation is used to solve by direct numerical simulation the compressible Navier-Stokes equations using high-order schemes. The radiated sound is directly computed in a domain that includes both the near-field aerodynamic source region and the far-field sound propagation. In the isothermal mixing layer, Mach number effects may be identified in the acoustic field through an increase of the directivity associated with the non-compactness of the acoustic sources. Baroclinic instability effects may be recognized in the non-isothermal mixing layer, as the presence of counter-rotating vorticity layers, the resulting acoustic sources being found less efficient. An analysis based on the acoustic analogy shows that the directivity increase with the Mach number can be associated with the emergence of density fluctuations of weak amplitude but very efficient in terms of noise generation at shallow angle. This influence, combined with convection and refraction effects, is found to shape the acoustic wavefront pattern depending on the Mach number.
Resumo:
Objectives-The purpose of this study was to predict perinatal outcomes using fetal total lung volumes assessed by 3-dimensional ultrasonography (3DUS) in primary pleural effusion. Methods-Between July 2005 and July 2010, total lung volumes were prospectively estimated in fetuses with primary pleural effusion by 3DUS using virtual organ computer-aided analysis software. The first and last US examinations were considered in the analysis. The observed/expected total lung volumes were calculated. Main outcomes were perinatal death (up to 28 days of life) and respiratory morbidity (orotracheal intubation with mechanical respiratory support >48 hours). Results-Twelve of 19 fetuses (63.2%) survived. Among the survivors, 7 (58.3%) had severe respiratory morbidity. The observed/expected total lung volume at the last US examination before birth was significantly associated with perinatal death (P < .01) and respiratory morbidity (P < .01) as well as fetal hydrops (P < .01) and bilateral effusion (P = .01). Conclusions-Fetal total lung volumes may be useful for the prediction of perinatal outcomes in primary pleural effusion.
Resumo:
The aim of this study was to evaluate the prognostic implications of the sonographic appearance of prostate cancers. All patients with biopsy-proven prostate cancer between January 2003 and July 2004 (and at least 5 years of follow-up) were selected retrospectively. After exclusions, 101 patients constituted our study population and were divided into isoechoic (or nonvisible) and hypoechoic (or visible) lesion. The clinical outcomes of these two groups were compared. The outcomes for the two groups were significantly different (p < 0.01). For nonvisible lesions, 37 of the 41 patients (90.2%) had no disease relapse and 2 (4.9%) had biochemical failure. For the visible lesions, 37 of the 60 (61.6%) patients were free of recurrence, 7 (11.7%) had systemic metastases and 10 (16.7%) died of complications related to prostate cancer. Our data show that patients with nonvisible prostate cancer had significantly better outcomes than patients with visible lesions during a five-year period of evaluation. (E-mail: fmuglia@fmrp.usp.br) (c) 2012 World Federation for Ultrasound in Medicine & Biology.
Resumo:
Ultrasonography has an inherent noise pattern, called speckle, which is known to hamper object recognition for both humans and computers. Speckle noise is produced by the mutual interference of a set of scattered wavefronts. Depending on the phase of the wavefronts, the interference may be constructive or destructive, which results in brighter or darker pixels, respectively. We propose a filter that minimizes noise fluctuation while simultaneously preserving local gray level information. It is based on steps to attenuate the destructive and constructive interference present in ultrasound images. This filter, called interference-based speckle filter followed by anisotropic diffusion (ISFAD), was developed to remove speckle texture from B-mode ultrasound images, while preserving the edges and the gray level of the region. The ISFAD performance was compared with 10 other filters. The evaluation was based on their application to images simulated by Field II (developed by Jensen et al.) and the proposed filter presented the greatest structural similarity, 0.95. Functional improvement of the segmentation task was also measured, comparing rates of true positive, false positive and accuracy. Using three different segmentation techniques, ISFAD also presented the best accuracy rate (greater than 90% for structures with well-defined borders). (E-mail: fernando.okara@gmail.com) (C) 2012 World Federation for Ultrasound in Medicine & Biology.
Resumo:
The purpose of the present study was to determine ultrasound (US) arthrography diagnostic accuracy in patients with recurrent shoulder dislocation by comparing US arthrography and magnetic resonance arthrography (MRA) with intraoperative findings. Fifty-six consecutive patients with diagnosis of chronic anterior instability of the shoulder were evaluated for assessment of bone and soft tissue lesions by three radiologists. Twenty-five cases were confirmed by surgery. Sensitivity, specificity, inter-and intraobserver agreement were calculated. Ultrasound sensitivity ranged from 20% to 100% and specificity from 25% to 90%. MRA sensitivity ranged from 80% to 100% and specificity from 50% to 100%. Interobserver agreement was good for MRA (0.54-0.70) and fair for US arthrography (0.19-0.40). Despite a higher interobserver variability for US arthrography than for MRA, our results indicate that US is capable of demonstrating bone and soft tissue lesions related to chronic instability of the shoulder in the presence of intra-articular fluid. (E-mail: marcelo_simao@hotmail.com) (C) 2012 World Federation for Ultrasound in Medicine & Biology.