905 resultados para Acceleration skewness
Resumo:
The present analysis takes into account the acceleration term in the differential equation of motion to obtain exact dynamic solutions concerning the groundwater flow towards a well in a confined aquifer. The results show that the error contained in the traditional quasi-static solution is very small in typical situations.
Resumo:
Piezoresistive materials, materials whose resistivity properties change when subjected to mechanical stresses, are widely utilized in many industries as sensors, including pressure sensors, accelerometers, inclinometers, and load cells. Basic piezoresistive sensors consist of piezoresistive devices bonded to a flexible structure, such as a cantilever or a membrane, where the flexible structure transmits pressure, force, or inertial force due to acceleration, thereby causing a stress that changes the resistivity of the piezoresistive devices. By applying a voltage to a piezoresistive device, its resistivity can be measured and correlated with the amplitude of an applied pressure or force. The performance of a piezoresistive sensor is closely related to the design of its flexible structure. In this research, we propose a generic topology optimization formulation for the design of piezoresistive sensors where the primary aim is high response. First, the concept of topology optimization is briefly discussed. Next, design requirements are clarified, and corresponding objective functions and the optimization problem are formulated. An optimization algorithm is constructed based on these formulations. Finally, several design examples of piezoresistive sensors are presented to confirm the usefulness of the proposed method.
Resumo:
The classical approach for acoustic imaging consists of beamforming, and produces the source distribution of interest convolved with the array point spread function. This convolution smears the image of interest, significantly reducing its effective resolution. Deconvolution methods have been proposed to enhance acoustic images and have produced significant improvements. Other proposals involve covariance fitting techniques, which avoid deconvolution altogether. However, in their traditional presentation, these enhanced reconstruction methods have very high computational costs, mostly because they have no means of efficiently transforming back and forth between a hypothetical image and the measured data. In this paper, we propose the Kronecker Array Transform ( KAT), a fast separable transform for array imaging applications. Under the assumption of a separable array, it enables the acceleration of imaging techniques by several orders of magnitude with respect to the fastest previously available methods, and enables the use of state-of-the-art regularized least-squares solvers. Using the KAT, one can reconstruct images with higher resolutions than was previously possible and use more accurate reconstruction techniques, opening new and exciting possibilities for acoustic imaging.
Resumo:
Renal diseases are common in older cats. Decreased renal blood flow may be the first sign of dysfunction and can be evaluated by Doppler ultrasound. But previous studies suggest that the resistive index (RI) has a low sensitivity for detecting renal disease. Doppler waveforms of renal and intrarenal arteries demonstrate decreased blood flow before there are any changes in the RI. The purpose of this study was to evaluate the normal Doppler flowmetrics parameters of renal arteries (RAs), interlobar arteries (IAs) and abdominal aorta (AO) in adult healthy, Persian cats. Twenty-five Persian cats (13 females and 12 males with mean age of 30 months and an age range 12-60 months) with normal clinical examinations and biochemical tests and normal systemic blood pressure were given B-mode ultrasonographies in order to exclude all nephropathies, including polycystic kidney disease. All measurements were performed on both kidneys. Both kidneys (n = 50) were examined by color mapping of the renal vasculature. Pulsed Doppler was used to examine both RAs, the IAs at cranial, middle and caudal sites, and the AO. The RI was calculated for all of the vessels. Early systolic acceleration (ESA) of RA and IA was obtained with Doppler spectral analysis. Furthermore, the ratio indices between RA/AO, and IA/RA velocities were calculated. The mean values of peak systolic velocity (PSV) and the diameter for AO were 53.17 +/- 13.46 cm/s and 0.38 +/- 0.08 cm, respectively. The mean RA diameter for all 50 kidneys was 0.15 +/- 0.02 cm. Considering the velocimetric values in both RAs, the mean PSV and RI that were obtained were 41.17 +/- 9.40 cm/s and 0.54 +/- 0.07. The RA had a mean ESA of 1.12 +/- 1.14 m/s(2) and the calculated upper limit of the reference value was 3.40 m/s(2). The mean renal-aortic ratio was 0.828 +/- 0.296. The IA showed PSV and RI values of 32.16 +/- 9.33 cm/s and 0.52 +/- 0.06, respectively. The mean ESA of all IAs was 0.73 +/- 0.61 m/s(2). The calculated upper limit of the reference value was 2.0 m/s(2). The mean renal-interlobar artery ratio was 1.45 +/- 0.57. The RI values obtained in this study were similar to values reported in the literature. Some conditions that lead to a decrease in compliance and to an increase in vascular resistance can affect the Doppler spectral waveforms without changes in RI. To our knowledge, there are no studies that were directed toward to the normal ESA values of the renal vasculature in Persian cats. This study introduced a new ratio between the PSV of the RA and the IA. This index was developed based on the well-known effects of Doppler on the detection of stenosis, regardless of the cause. Further studies are necessary to verify the hemodynamic behavior of this index under pathological conditions in cats as well as the effect of aging, nephropathies and systemic pressure on Doppler velocimetric parameters. (C) 2010 ISFM and AAFP. Published by Elsevier Ltd. All rights reserved.
Resumo:
Inulin was used as a prebiotic to improve quality of skim milk fermented by pure cultures of Lactobacillus acidophilus Lactobacillus rhamnosus Lactobacillus bulgaricus and Bifidobacterium lactis binary co-cultures with Streptococcus thermophilus or a cocktail containing all them Inulin supplementation to pure cultures lowered the generation time with particular concern to S thermophilus and L acidophilus The generation time of all micro-organisms decreased in the following order mono-cultures co-cultures cocktail It was demonstrated a synergism between S thermophilus and the other strains and a bifidogenic effect of inulin Enumerations of L rhamnosus in cocktail markedly decreased compared to co-cultures likely because of greater competition for the same substrates The results of this work highlight the industrial potential of the cocktail mainly in terms of fermentation acceleration (C) 2010 Elsevier Ltd All rights reserved
Resumo:
In this work, we give a description of the process of teleportation between Alice in an inertial frame, and Rob who is in uniform acceleration with respect to Alice. The fidelity of the teleportation is reduced due to Davies-Unruh radiation in Rob's frame. In so far as teleportation is a measure of entanglement, our results suggest that quantum entanglement is degraded in noninertial frames.
Resumo:
The tensions produced in the wall of a rigid, thin-walled, liquid-filled sphere as it moves with an axisymmetric straining flow are examined. This problem has not been previously addressed. A generalised correlation for the maximum wall tension, expressed in dimensionless form as a Weber number (We), is developed in terms of the acceleration number (Ac) and Reynolds number (Re) of the straining flow. At low Reynolds number We is dominated by viscous forces, while inertial forces due to internal pressure gradients caused by sphere acceleration dominate at higher Re. The generalised correlation has been used to examine the case of a typical yeast cell (a thin-walled, liquid-filled sphere) passing through a typical high-pressure homogeniser (a straining-flow device). At 56 MPa homogenising pressure, a 6 mu m yeast cell experiences tensions in the inertially dominated regime (Re = 100). The correlation gives We = 0.206, corresponding to a maximum wall tension of 8 Nm(-1). This is equivalent to an applied compressive force of 150 mu N and compares favourably with the force required to break yeast cells under compressive micromanipulation (40-90 mu N). Inertial forces may therefore be an important and previously unrecognised. mechanism of microbial cell disruption during high-pressure homogenisation. Further work is required to examine the likelihood of cell deformation in the high-strain-rate short-residence-time environment of the homogeniser, and the effect that such deformation may have on the contribution of inertial forces to disruption. (C) 1998 Published by Elsevier Science Ltd. All rights reserved.
Resumo:
This study examined the relationship between isokinetic hip extensor/hip flexor strength, 1-RM squat strength, and sprint running performance for both a sprint-trained and non-sprint-trained group. Eleven male sprinters and 8 male controls volunteered for the study. On the same day subjects ran 20-m sprints from both a stationary start and with a 50-m acceleration distance, completed isokinetic hip extension/flexion exercises at 1.05, 4.74, and 8.42 rad.s(-1), and had their squat strength estimated. Stepwise multiple regression analysis showed that equations for predicting both 20-m maximum velocity nm time and 20-m acceleration time may be calculated with an error of less than 0.05 sec using only isokinetic and squat strength data. However, a single regression equation for predicting both 20-m acceleration and maximum velocity run times from isokinetic or squat tests was not found. The regression analysis indicated that hip flexor strength at all test velocities was a better predictor of sprint running performance than hip extensor strength.
Resumo:
In order to effectively suppress the noise radiation from large electrical power transformers, both the structure-borne and air-borne sound fields need to be characterised. The characterisation can be made either from theoretical predictions or by in-situ measurements. This paper presents the study of the sound radiation from a large power transformer in a substation. The radiation pattern can be predicted from the measured acceleration distribution and the predicted value is not affected by other noise sources. Alternatively, the farfield sound pressure level can be predicted from the sound pressure level measured at NEMA locations. Both the near- and far-field power radiation can be in-situ measured using the sound intensity technique. It is shown that both the vibration of a transformer tank wall and the radiated noise consist of a series of tonal components mainly at the first few harmonic frequencies of 100 Hz. Also, the neglect of the noise radiation from the transformer (top and bottom) lids does not affects the accuracy of the transformer radiation characterisation. (C) 1998 Elsevier Science Ltd. All rights reserved.
Resumo:
Previous analyses of thermal acclimation of locomotor performance in amphibians have only examined the adult life history stage and indicate that the locomotor system is unable to undergo acclimatory changes to temperature. In this study, we examined the ability of tadpoles of the striped marsh frog (Limnodynastes peronii) to acclimate their locomotor system by exposing them to either 10 degrees C or 24 degrees C for 6 weeks and testing their burst swimming performance at 10, 24, and 34 degrees C. At the test temperature of 10 degrees C, maximum velocity (U-max) of the 10 degrees C-acclimated tadpoles was 47% greater and maximum acceleration (A(max)) 53% greater than the 24 degrees C-acclimated animals. At 24 degrees C, U-max was 16% greater in the 10 degrees C-acclimation group, while there was no significant difference in A(max) or the time taken to reach U-max (T-U-max). At 34 degrees C, there was no difference between the acclimation groups in either U-max or A(max), however T-U-max was 36% faster in the 24 degrees C-acclimation group. This is the first study to report an amphibian (larva or adult) possessing the capacity to compensate for cool temperatures by thermal acclimation of locomotor performance. To determine whether acclimation period affected the magnitude of the acclimatory response, we also acclimated tadpoles of L. peronii to 10 degrees C for 8 months and compared their swimming performance with tadpoles acclimated to 10 degrees C for 6 weeks. At the test temperatures of 24 degrees C and 34 degrees C, U-max and A(max) were significantly slower in the tadpoles acclimated to 10 degrees C for 8 months. At 10 degrees C, T-U-max was 40% faster in the 8-month group, while there were no differences in either U-max or A(max). Although locomotor performance was enhanced at 10 degrees C by a longer acclimation period, this was at the expense of performance at higher temperatures.
Resumo:
1. The co-ordination between respiratory and postural functions of the diaphragm was investigated during repetitive upper Limb movement. It was hypothesised that diaphragm activity would occur either tonically or phasically in association with the forces from each movement and that this activity would combine with phasic respiratory activity. 2. Movements of the upper limb and ribcage were measured while standing subjects performed repetitive upper limb movements 'as fast as possible'. Electromyographic (EMG) recordings of the costal diaphragm were made using intramuscular electrodes in four subjects. Surface electrodes were placed over the deltoid and erector spinae muscles. 3. In contrast to standing at rest, diaphragm activity was present throughout expiration at 78 +/- 17% (mean +/- S.D.) of its peak inspiratory magnitude during repeated upper limb movement. 4. Bursts of deltoid and erector spinae EMG activity occurred at the Limb movement frequency (similar to 2.9 Hz). Although the majority of diaphragm EMG power was at the respiratory frequency (similar to 0.4 Hz), a peak was also present at the movement frequency. This finding was corroborated by averaged EMG activity triggered from upper limb movement. In addition, diaphragm EMG activity was coherent with ribcage motion at the respiratory frequency and with upper limb movement at the movement frequency. 5. The diaphragm response was similar when movement was performed while sitting. In addition, when subjects moved with increasing frequency the peak upper limb acceleration correlated with diaphragm EMG amplitude. These findings support the argument that diaphragm contraction is related to trunk control. 6. The results indicate that activity of human phrenic motoneurones is organised such that it contributes to both posture and respiration during a task which repetitively challenges trunk posture.
Resumo:
Ultra-rapid opioid detoxification (UROD) involves the acceleration of opioid withdrawal hv administering thp opioid receptor antagonist naltrexone under general anaesthesia. There is evidence from uncontrolled and a few controlled studies that UROD accelerates opioid withdrawal and that it achieves high rates of completion of acute opioid withdrawal. However, there is clear evidence that the use of a general anaesthetic is not required to accelerate withdrawal or to achieve high rates of completion of acute opioid withdrawal. These goals can be achieved by using naltrexone or naloxone to accelerate withdrawal under light sedation, a procedure known as rapid opioid detoxification under sedation (ROD). There is also evidence that use of an opioid antagonist is not required to achieve a high rate of completion of acute opioid withdrawal. The mixed agonist-antagonist buprenorphine has achieved comparable rates of completion in similarly selected patients with fewer withdrawal symptoms. There is no evidence from controlled trials that either UROD or ROD increases the rate of abstinence from opioids 6 or 12 months after withdrawal. UROD and ROD may increase the number of patients who are inducted onto naltrexone maintenance (NM) therapy but extensive experience with NM therapy suggests that it only has a limited role in selected patients. Given the lack of evidence of substantially increased rates of abstinence, and the need for anaesthetists and high dependency beds, UROD has at best a very minor role in the treatment of a handful of opioid dependent patients who are unable to complete withdraw in any other way. ROD may have more of a role as one option for opioid withdrawal in well motivated patients who want to be rapidly inducted onto NM therapy or who want to enter other types of abstinence-oriented treatment.
Resumo:
In this work, we describe the process of teleportation between Alice in an inertial frame, and Rob who is in uniform acceleration with respect to Alice. The fidelity of the teleportation is reduced due to Davies-Unruh radiation in Rob's frame. In so far as teleportation is a measure of entanglement, our results suggest that quantum entanglement is degraded in non-inertial frames. We discuss this reduction in fidelity for both bosonic and fermionic resources.
Resumo:
Glucocorticoids are an important cause of secondary osteoporosis in humans, which decreases bone quality and leads to fractures. Mechanical stimulation in the form of low-intensity and high-frequency vibration seems to be able to prevent bone loss and to stimulate bone formation. The objective of this study was to evaluate the effects of mechanical vibration on bone structure in rats treated with glucocorticoids. Thirty 3-month-old adult male Wistar rats were randomized to three groups: control (C), glucocorticoid (G), and glucocorticoid with vibration (CV). The G and GV groups received 3.5 mg/kg/day of methylprednisolone 5 days/week for a duration of 9 weeks, and the C group received vehicle (saline solution) during the same period. The CV group was vibrated on a special platform for 30 min per day, 5 days per week during the experiment. The platform was set to provide a vertical acceleration of 1 G and a frequency of 60 Hz. Skeletal bone mass was evaluated by total body densitometry (DXA). Fracture load threshold, undecalcified bone histomorphometry, and bone volume were measured in tibias. Glucocorticoids induced a significantly lower weight gain (-9.7%) and reduced the bone mineral content (-9.2%) and trabecular number (-41.8%) and increased the trabecular spacing (+98.0%) in the G group, when compared to the control (C). Vibration (CV) was able to significantly preserve (29.2%) of the trabecular number and decrease the trabecular spacing (+ 26.6%) compared to the G group, although these parameters did not reach C group values. The fracture load threshold was not different between groups, but vibration significantly augmented the bone volume of the tibia by 21.4% in the CV group compared to the C group. Our study demonstrated that low-intensity and high-frequency mechanical vibration was able to partially inhibit the deleterious consequences of glucocorticoids on bone structure in rats. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
The aim of this study was to evaluate (1) the prevalence of periodic leg movements during sleep (PLMs) in a consecutive sample of congestive heart failure (CHF) outpatients; (2) the presence of correlation between PLMs, subjective daytime sleepiness, and sleep architecture; and (3) the heart rate response to PLMs in CHF. Seventy-nine [50 men, age 59 +/- 11 years, body mass index (BMI) 26 +/- 5 kg/m(2)] consecutive adult stable outpatients with CHF [left ventricular ejection fraction (LVEF) 36 +/- 6%] were prospectively evaluated. The patients underwent assessment of echocardiography, sleepiness (Epworth Scale), and overnight in-lab polysomnography. Fifteen patients (19%) had PLM index > 5. These subjects were similar in sex distribution, BMI, subjective somnolence, LVEF, and apnea-hypopnea index (AHI), but were significantly older than subjects without PLMs. Sleep architecture was similar in subjects with and without PLMs. There was a small but significant elevation of heart rate after PLMs (80.1 +/- 9.4 vs. 81.5 +/- 9.2; p < 0.001). The cardiac acceleration was also present in absence of electroencephalogram activation. The prevalence of PLMs in consecutive sample of adult CHF outpatients was 19%. There were no differences in subjective daytime sleepiness, sleep architecture, AHI, and severity of CHF in subjects with and without PLMs. PLMs caused a small but statistically significant cardiac acceleration.