1000 resultados para 271
Resumo:
Eur. J. Biochem. 271, 2361–2369 (2004)
Resumo:
Eur. J. Biochem. 271, 1329–1338 (2004)
Resumo:
Due to the growing complexity and adaptability requirements of real-time embedded systems, which often exhibit unrestricted inter-dependencies among supported services and user-imposed quality constraints, it is increasingly difficult to optimise the level of service of a dynamic task set within an useful and bounded time. This is even more difficult when intending to benefit from the full potential of an open distributed cooperating environment, where service characteristics are not known beforehand. This paper proposes an iterative refinement approach for a service’s QoS configuration taking into account services’ inter-dependencies and quality constraints, and trading off the achieved solution’s quality for the cost of computation. Extensive simulations demonstrate that the proposed anytime algorithm is able to quickly find a good initial solution and effectively optimises the rate at which the quality of the current solution improves as the algorithm is given more time to run. The added benefits of the proposed approach clearly surpass its reducedoverhead.
Resumo:
Micro-abrasion wear tests with ball-cratering configuration are widely used. Sources of variability are already studied by different authors and conditions for testing are parameterized by BS EN 1071-6: 2007 standard which refers silicon carbide as abrasive. However, the use of other abrasives is possible and allowed. In this work, ball-cratering wear tests were performed using four different abrasive particles of three dissimilar materials: diamond, alumina and silicon carbide. Tests were carried out under the same conditions on a steel plate provided with TiB2 hard coating. For each abrasive, five different test durations were used allowing understanding the initial wear phenomena. Composition and shape of abrasive particles were investigated by SEM and EDS. Scar areas were observed by optical and electronic microscopy in order to understand the wear effects caused by each of them. Scar geometry and grooves were analyzed and compared. Wear coefficient was calculated for each situation. It was observed that diamond particles produce well-defined and circular wear scars. Different silicon carbide particles presented dissimilar results as consequence of distinct particle shape and size distribution.
Resumo:
Abrasion by glass fibers during injection molding of fiber reinforced plastics raises new challenges to the wear performance of the molds. In the last few decades, a large number of PVD and CVD coatings have been developed with the aim of minimizing abrasion problems. In this work, two different coatings were tested in order to increase the wear resistance of the surface of a mold used for glass fiber reinforced plastics: TiAlSiN and CrN/CrCN/DLC. TiAlSiN was deposited as a graded monolayer coating while CrN/CrCN/DLC was a nanostructured coating consisting of three distinct layers. Both coatings were produced by PVD unbalanced magnetron sputtering and were characterized using scanning electron microscopy (SEM) provided with energy dispersive spectroscopy (EDS), atomic force microscopy (AFM), micro hardness (MH) and scratch test analysis. Coating morphology, thickness, roughness, chemical composition and structure, hardness and adhesion to the substrate were investigated. Wear resistance was characterized through industrial tests with coated samples and an uncoated reference sample inserted in a feed channel of a plastic injection mold working with 30 wt.% glass fiber reinforced polypropylene. Results after 45,000 injection cycles indicate that the wear resistance of the mold was increased by a factor of 25 and 58, by the TiAlSiN and CrN/CrCN/DLC coatings, respectively, over the uncoated mold steel.
Resumo:
Dissertação apresentada à Escola Superior de Comunicação Social como parte dos requisitos para obtenção de grau de mestre em Publicidade e Marketing.
Resumo:
Journal of Biological Inorganic Chemistry (2010)15: 271-281
Resumo:
O autor tece alguns comentários acerca das inovações introduzidas no vocabulário médico (tanto em português como em inglês) e levanta algumas questões sobre o seu verdadeiro significado.
Resumo:
Aim. Percutaneous endovascular procedures have become the standard treatment of arteriovenous fistulae and graft stenosis. This study evaluates the immediate results of angiographic procedures performed by nephrologists in patients with dysfunctional arteriovenous fistulae and arteriovenous graft stenosis. Patients and Methods. A retrospective analysis was performed on patients referred to the three Interventional Nephrology units between April and June, 2010. Clinical data were recorded. Results. A total of 113 procedures were performed: 59 in arteriovenous fistulae and 54 in arteriovenous graft stenosis. The main reasons for referral were increased venous pressure (21%), limb oedema (21%) and decreased intra-access flow (20%). Stenoses were detected in 85% of the procedures, mostly in patients with arteriovenous graft stenosis (56%). The main locations of stenosis were the outflow vein (cephalic/basilic) in arteriovenous fistulae (34%) and venous anastomosis in arteriovenous graft stenosis(48%). Angioplasty was performed in 73% of procedures where stenoses were detected. The immediate success rate was 91% for arteriovenous fistulae and 83% for arteriovenous graft stenosis. Partial success was obtained in 11% of angiographies. The complication rate was 7%. Conclusions. Physical examination findings led, in at least half the cases, to angiography referral and enabled the diagnosis and treatment of stenoses. For this reason, we advocate that this tool should be included in any vascular access monitoring programme. Our results support the safety of these procedures performed by nephrologists and their efficacy in the recovery of dysfunctional arteriovenous fistulae and arteriovenous graft stenosis.
Resumo:
O Rastreio Universal da Audição Neonatal tem sido um objectivo que várias gerações de audiologistas, otorrinolaringologistas e pediatras tem tentado ao longo dos anos. Os autores fazem uma revisão dos principais métodos utilizados para a avaliação da audição dos recém-nascidos, bem como das dificuldades encontradas e limitações da sua utilização. Desde o inicio da década de noventa vêm a ser implementados verdadeiros métodos de detecção precoce e universal da surdez infantil, utilizando métodos fisiológicos tais como os potenciais evocados auditivos e as otoemissões acústicas (c1ássicos e automáticos). São descritos os artigos mais importantes que fundamentam a necessidade de diagnóstico e intervenção precoces na surdez sensorioneural, com vista a melhorar a aquisição e desenvolvimento da fala e da competência linguística, o que permite uma melhor integração da criança, independentemente do seu grau de surdez. São também enunciadas as directivas do "European Consensus Development on Neonatal Hearing Screening" e do "Joint Comitee on Infant Hearing".
Resumo:
Os autores apresentam um caso de pielonefrite enfisematosa a E. coli, numa doente diabética de 63 anos. Os exames imagiológicos(Rx simples do abdómen, ultrassonografia e tomografia computorizada) permitiram estabelecer o diagnóstico. A nefrostomia percutânea, combinada com o tratamento médico, contribuiu para a favorável evolução clínica.
Resumo:
De janeiro de 1986 a fevereiro de 1994foram aplicados 563 xenodiagnósticos (XD) em igual número de pacientes chagásicos crônicos de diferentes áreas do Brasil; 292 mulheres e 271 homens com idades entre 6 e 89 anos (média = 41,4 ± 14, 7 anos). Em cada XD foram empregadas 40 ninfas no 4S estádio: 20 de Panstrongylus megistus (Pm) e 20 de Triatoma infestans (Ti) em jejum de pelo menos 14 dias. O exame de cada ninfa foi realizado 45 dias depois de aplicada no paciente, através da observação por microscopia óptica das fezes e/ou do triturado do tubo digestivo. Foram observados os seguintes resultados: a) XD positivos em 205 (36,4%) pacientes, sendo 85 (15,1%) devido exclusivamente às ninfas de Pm, 44 (7,8%) devido às de Ti e 76 (13,5%) devido a ambas Pm e Ti; b) positividade em 4,9% das ninfas de Pm e em 3,0% das ninfas de Ti. A análise destes resultados mostrou que as ninfas de Pm foram mais sensíveis do que as de Ti à infecção pelo Trypanosoma cruzi, aumentando significativamente a xenopositividade, independentemente da área de origem, sexo e faixa etária dos pacientes. Estes resultados indicam que, para aumentar o rendimento do XD na doença de Chagas crônica, este exame deve conter mais de uma espécie de triatomíneo com diferentes sensibilidades à infecção pelo T. cruzi e, no caso de uso de apenas uma espécie, as ninfas IV de Pm devem substituir as ninfas IV de Ti.
Resumo:
in Varia, Revista do IHA, N.5 (2008), pp.259-271